• Title/Summary/Keyword: 병렬 저수지

Search Result 26, Processing Time 0.03 seconds

Parallel Reservoir Analysis of Drought Period by Water Supply Allocation Method (공급량 배분기법을 이용한 갈수기 병렬저수지 해석)

  • Park Ki-Bum;Lee Soon-Tak
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.261-269
    • /
    • 2006
  • In this study, an optimization technique was developed from the application of allocation rule. The results obtained from the water supply analysis and reliability indices analysis of Andong dam and Imha dam which are consist of parallel reservoir system are summarized as the followings; Allocation rule(C) is effective technique at the parallel reservoir system because results of the water supply analysis, storage analysis and reliability indices analysis is calculated reasonable results. Also, reliability indices analysis results are not sufficient occurrence based reliability or quantity based reliability. Thus reliability indices analysis are need as occurrence based reliability, quantity based reliability vulnerability, resilience, average water supply deficits and average storage. And water supply condition is better varying water supply condition than constant water supply condition.

Validations of Water Resources Planning by K-MODSIM Model (K-ModSim 모형에 대한 수자원계획 적용성 검토)

  • Kang, Shin-Uk;Cheong, Tae-Sung;Hwang, Man-Ha;Ko, Ick-Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.2044-2048
    • /
    • 2007
  • K-ModSim 모형을 이용하여 금강권역의 2006년의 기준수요량에 대한 수자원부존량을 평가하였다. 이에 대한 2006년 기준 생활, 공업, 농업, 하천유지용수 자료와 38년의 자연유출량 자료를 이용하고, 금강권역의 기존 및 계획 광역상수도를 고려한 물수지 네트워크를 작성하여 수행하였다. 수행결과 금강권역은 2006년 기준수요에 대해 74백만$m^3$/년의 물부족이 발생하였다. 금강권역에 대한 물수지분석 과정을 통해 K-ModSim 모형의 활용성을 확인할 수 있었다. 그동안 국내 사용자들에게 결과의 의문을 갖게 만들었던 병렬저수지 문제는 Reservoir Balancing을 이용해 동일 비율로 방류하도록 보완되었고, 입출력에 대해서 Excel 프로그램과 연동되게하여 복사 및 붙이기가 가능하도록 편리하게 개선되었다. K-ModSim 모형은 복잡한 유역의 효율적인 수자원 관리 및 운영을 위해 이해관계자에게 효율적인 정보를 제공할 수 있는 유용한 도구라고 판단된다.

  • PDF

Parallel reservoirs system operation using NYC-Space Allocation-Rule (NYC-Space Allocation Rule을 이용한 병렬저수지 연계운영)

  • Park Ki-Bum;Lee Soon-Tak
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.533-542
    • /
    • 2005
  • In this study, an optimization technique was developed from the application of Allocation Rule. Average Allocation coefficients of the Andong and Imha dam compare constant water supply condition with vary water supply condition that are above the contribute ratio $67\%\~50\%$ the Andong dam in Rule(A)-Rule(C). In the Refill Season, Andong dam water supply contribution is higher than Imha dam at the Control point water supply. In the Allocation analysis results, Rule(A) is calculated storage ratio because Andong dam contribute to Control point larger than Imha dam which Andong dam storage is larger than Imha dam storage. Rule(B) calculated sum of the storage and inflow ratio for Andong dam and Imha dam, as Andong dam contribution is higher than Imha dam. Rule(C) calculated that sum of storage, inflow and water supply is divided average storage ratio, as the best results of the Allocation coefficients and water supply capacity. The results of storage analysis is larger vary water supply condition than constant water supply condition and the results of water supply analysis is larger vary water supply condition than constant water supply condition. Water supply deficit is decrease $30\%$ for vary water supply condition.

Study on Potential Water Resources of Andong-Imha Dam by Diversion Tunnel (안동-임하 연결도수로 설치에 따른 가용 수자원량에 관한 연구)

  • Choo, Yeon Moon;Jee, Hong Kee;Kwon, Ki Dae;Kim, Chul Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1126-1139
    • /
    • 2014
  • World is experiencing abnormal weather caused by urbanization and industrialization increasing greenhouse gas and one of these phenomenon domestically happening is flood and drought. The increase of green-house gases is due to urbanization and industrialization acceleration which are causing abnormal climate changes such as the El Nino and a La Nina phenomenon. It is expected that there will be many difficulties in water management, especially considering the topography and seasonal circumstances in Korea. Unlike in the past, a variety of water conservation initiatives have been undertaken like the river-management flow and water capacity expansion projects. To meet the increasing demand for water resources, new environmentally-friendly small and medium-sized dams have been built. Therefore, the development of a new paradigm for water resources management is essential. This study shows that additional security is needed for potential water resources through diversion tunnels and is very important to consider for future water supplies and situations. Using RCP 6.0 and RCP 8.5 in representative concentration pathway climate change scenario, specific hydrologic data of study basin was produced to analyze past observed basin rainfall tendency which showed both scenario 5%~9% range increase in rainfall. Through sensitivity analysis using objective function, population in highest goodness was 1000 and cross rate was 80%. In conclusion, it is expected that the results from this study will help to make long-term and stable water supply plans by using the potential water resource evaluation model which was applied in this study.

Analysis of Parallel Reservoir Water Supply Capacity According to Water Supply Changes (용수공급 변화에 따른 병렬저수지 용수공급 능력 해석)

  • Jea Min Park;Ki bum Park
    • Journal of Environmental Science International
    • /
    • v.32 no.10
    • /
    • pp.675-684
    • /
    • 2023
  • In this study, the water supply reliability of the andong and Imha dam was analyzed using inflow data for 360 months from 1993 to 2022 through allocation model. First, in the analysis results of additional water supply to Deagu city, the water supply reliability of Rule (B) was the highest at 86% for andong dam, 84% for imha dam, and 80% for the control point. However, when the planned supply was supplied, the analysis results showed 94%, 93%, and 90%. Next, in the quantitative reliability analysis results, when considering additional water supply to Deagu city, Rule (A), Rule (B), and Rule (C) were analyzed as 88%, 88%, and 88%, respectively, based on the control point. When supplying the planned water supply, the quantitative reliability analysis results were 95% equally based on Rule (A), Rule (B), and Rule (C). Because of evaluating the two reliability methods, the number of shortages increases significantly when additional water is supplied to Daegu City, but the shortage is generally 5-7%, resulting in a relatively small shortage compared with the increase in the number of shortages. In the case of resilience and vulnerability, additional water supply to Daegu City takes more than two months to restore than the existing planned water supply, and the average shortage was calculated to be smaller than that of supplying the planned water. According to the results of the analysis, Andong dam has an average water storage of 130x106 m2 and Imha dam has 50x106 m2. In this deficient water supply can be compensated by water from the Nakdong river.

Planning for Securing Instreamflow of Gapcheon Stream in Daejeon (대전 갑천의 유지유량 확보 방안)

  • Noh, Jae-Kyoung
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.87-98
    • /
    • 2009
  • The objective of this study is to evaluate the effect of increasing instream flow at Gapcheon stream of Daejeon city by considering two virtual reservoirs upstream, respectively; Geum-gok reservoir and Koe-gok reservoir upstream, respectively. The paralleled and cascaded reservoir operations were performed including the existing Jang-an and Bang-dong reservoirs. The results are summarized as follows. Firstly, from the Bang-dong and Geum-gok cascaded reservoir's water balance analysis, instream flow of $6.83Mm^3$ was able to be supplied to downstream, and water supply indexes of Geum-gok reservoir were analyzed to have the rate of water supply divided by watershed area of 403.4 mm, the rate of water supply divided by rainfall of 33.0 %, the rate of water supply divided by inflow of 96.4 %, the rate of water supply divided by storage capacity of 81.9 %, and the rate of inflow divided by storage capacity of 112.3 %. Secondly, from the Jang-an and Geum-gok paralleled reservoir's water balance analysis, flow durations at Gapcheon station were analyzed to have Q95 (the 95th high flow) of $4.806m^3/s$, Q185 (the 185th high flow) of $2.217m^3/s$, Q275 (the 275th high flow) of $1.140m^3/s$, and Q355 (the 355th high flow) of $0.887m^3/s$. Thirdly, inflow to Koe-gok reservoir was simulated including the Jang-an and Bang-dong paralleled reservoir's water balance analysis, instream flow of $49.60Mm^3$ was able to be supplied from Koe-gok reservoir to downstream, and water supply indexes of Koe-gok reservoir were analyzed to have the rate of water supply divided by watershed area of 246.5 mm, the rate of water supply divided by rainfall of 19.4 %, the rate of water supply divided by inflow of 40.8 %, the rate of water supply divided by storage capacity of 412.1 %, and the rate of inflow divided by storage capacity of 1,189.8 %. Fourthly, daily streamflows at Gapcheon stream were simulated including outflows from Koe-gok reservoir, flow durations at Gapcheon station were analyzed to have Q95 (the 95th high flow) of $4.501m^3/s$, Q185 (the 185th high flow) of $2.277m^3/s$, Q275 (the 275th high flow) of $1.743m^3/s$, and Q355 (the 355th high flow) of $1.564m^3/s$. The conclusion appeared that the effect of increasing instream flow at Gapcheon stream from Koe-gok reservoir was more higher than that from Geum-gok reservoir.

  • PDF