• Title/Summary/Keyword: 병렬제어

검색결과 937건 처리시간 0.026초

COMS Electrical Power Subsystem Preliminary Design (통신해양기상위성 전력계 예비설계)

  • Gu, Ja-Chun;Kim, Ui-Chan
    • Journal of Satellite, Information and Communications
    • /
    • 제1권2호
    • /
    • pp.95-100
    • /
    • 2006
  • The COMS(Communication, Ocean and Meteorological Satellite) EPS(Electrical Power Subsystem) is derived from an enhanced Eurostar 3000 version. Eurostar 3000 EpS is fully autonomous operation in nominal conditions or in the event of a failure and provides a high level of reconfigure capability. This paper introduces the COMS EPS preliminary design result. COMS EPS consists of a battery, a solar arrat wing, a PSR(Power Supply Regulator), a PRU(Pyrotechnic Unit), a SDAM(Solar Array Drive Mechanism) and relay and fuse brackets. COMS EPS can offer a bus power capability of 3 kW. The solar array is made of a deployable wing with two panels. One type fo solar cells is selected ad GaAs/Ge triple junction cells. Li-ion battery is base lined with ten series cell module of five cells in parallel. PSR associated to battery and solar array wing generates a power bus fully regulated at 50 V. Power bus os centralized protection and distribution by relay and fuse brackets. PRU provides power for firing actuarors devices. The solar array wing is rotated by the SADM under control of the attitude orbit control subsystem. The control and monitoring of the EPS, especially of the battery, is performed by the PSR in combination with the on-board software.

  • PDF

조광기능을 갖춘 전자식 형광등용 IC

  • 최낙춘;신동명;김덕중
    • 전기의세계
    • /
    • 제43권1호
    • /
    • pp.13-19
    • /
    • 1994
  • 전자식 안정기는 최근 에너지 절약 정책과 관련하여 조명기기분야의 관심의 대상이 되었고, 절전 효율이 높은 고품질의 전자식 안정기에 대한 연구 개발 및 보급이 점점 더 확대되고 있는 추세이다. 일반적으로 전자식 안정기는 수십 KHz의 고주파에서 형광등을 구동시킴으로써 빛의 깜박거림과 가청잡음이 없으며, 저주파(60Hz)에서 사용하는 재래식 안정기(choke coil 방식)에 비해 높은 절전 효과를 얻을 수 있다[1-4]. 특히, 빌딩 사무실의 경우 낮에도 창가의 형광등이 켜져 있어서 막대한 전력을 낭비하고 있는 실정이므로, 일조량에 따른 자동 전력 조절이 가능한 전자식 형광등의 출현이 기대되고 있다. 전자식 안정기의 보급 확대를 위해서는 절전 효과 뿐만 아니라, 품질 문제, 수명 문제등을 고려하여야 하는 바, 예를 들면 순간 점등으로 방전초기의 sputtering 현상에 의한 lamp의 수명 단축, 미소 입력전압 변동에 따른 급격한 광출력의 변화로 절전 효과의 상실과 이상동작에 의한 스위칭 소자의 파괴 현상, 고주파 스위칭시 발생되는 전력손실과 noise등에 대한 대책이 요구되고 있다. 이러한 점을 개선하기 위해 추가되는 회로는 전자식 안정기 시스템을 더욱 복잡하게 만들고, 경제적으로 원가 부담을 주기 때문ㅇ 고품질의 전자식 안정기를 보급하는데 어려운 점으로 부각되고 있다. 본 고에서는 이러한 문제를 해결하기 위하여 조광기능을 포함한 다양한 제어회로와 보호회로를 조광기능을 포함한 다양한 제어회로와 보호회로를 1 chip에 수용하는 고품질의 전자식 안정기 제어용 집적회로에 대해서 기술하고자 한다.되어 나아갈 기술의 조류에도 부합하는 형태라 하겠다. 그러나 이 방식은 기 언급한 바와 같이 분산처리를 관장하는 운영체계의 개발에 상당한 고전이 따르리라 보여지며, 또한 보다 상세한 연구가 선행되어야 하겠지만 개발된 상용의 통신 프로토콜로서는 병렬처리의 성능을 극대화 하기에는 여러가지 제약이 있을 것으로 예측된다.기기들이 어떻게 응용되고 있는지 살펴보기로 하자. real informations would be available. Results are compared with those of optimal power flows.기능시험을 완료했으며 실제 line-of-sight(LOS) 시스템 구현에 적용중이다. 시대를 살아 갈 회원들이다. '컨텐츠의 시대'가 개막되는 것이며, 신세기통신과 SK텔레콤은 선의의 경쟁 과 협력을 통해 이동인터넷 서비스의 컨텐츠를 개발해 나가게 될 것이다. 3배가 높았다. 효소 활성에 필수적인 물의 양에 따른 DIAION WA30의 라세미화 효율에 관하여 실험한 결과, 물의 양이 증가할수록 그 효율은 감소하였다. DIAION WA30을 라세미화 촉매로 사용하여 아이소옥탄 내에서 라세믹 나프록센 2,2,2-트리플로로에틸 씨오에스터의 효소적 DKR 반응을 수행해 보았다. 그 결과 DIAION WA30을 사용하지 않은 경우에 비해 반응 전환율과 생성물의 광학 순도는 급격히 향상되었다. 전통적 광학분할 반응의 최대 50%라는 전환율의 제한이 본 연구에서 찾은 DIAION WA30을 첨가함으로써 성공적으로 극복되었다. 또한 고체 염기촉매인 DIAION WA30의 사용은 라세미화 촉매의

  • PDF

Effects of Lettuce Cultivation Using Optical Fiber in Closed Plant Factory (폐쇄형 식물공장내 태양광 파이버를 이용한 상추 재배효과)

  • Lee, Sanggyu;Lee, Jaesu;Won, Jinho
    • Journal of Bio-Environment Control
    • /
    • 제29권2호
    • /
    • pp.105-109
    • /
    • 2020
  • This study was conducted to the improvement of solar light-based artificial light supply system and effect of lettuce cultivation. The artificial light supply system was consisted of units such as light source, power, system measurement and controller. The light source supply was composed of a solar transmitter and an LED lamp. The power supply consisted of an leakage breaker, SMPS, LED controller and relay. The solar transmitter was made of a quartz optical fiber with optimal light transmission. Artificial light used white lamp among LEDs. System measurement and control consisted of touch screen, Zigbee communication module and light quantity sensor. The results of test confirmed that the LED light is automatically activated when the intensity measured by the light intensity sensor is 200 μmolm-2s-1 or less. Moreover, the leaf length, root length, chlorophyll content and root fresh weight of optical fiber treatment was hight than LED lamp treatment. Therefore, it can be inferred that the energy-saving solar light collector device can be effective in the indoor lettuce production. However, the use of LED lamp is also recommended to assure the availability of sufficient sunlight in cloudy and rainy days.

The bidirectional DC module type PCS design for the System Inter Connection PV-ESS of Secure to Expandability (계통 연계 PV-ESS 확장성 확보를 위한 병렬 DC-모듈형 PCS 설계)

  • Hwang, Lark-Hoon;Na, Seung-Kwon;Choi, Byung-Sang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • 제14권1호
    • /
    • pp.56-69
    • /
    • 2021
  • In this paper, the PV system with a link to the commercial system needs some advantages like small capacity, high power factor, high reliability, low harmonic output, maximum power operation of solar cell, and low cost, etc. as well as the properties of inverter. To transfer the PV energy of photovoltaic power generation system to the system and load, it requires PCS in both directions. The purpose of this paper is to confirm the stable power supply through the load leveling by presenting the PCS considering ESS of photovoltaic power generation. In order to achieve these purpose, 5 step process of operation mode algorithm were used according to the solar insolation amount and load capacity and the controller for charging/ discharging control was designed. For bidirectional and effective energy transfer, the bidirectional converter and battery at DC-link stage were connected and the DC-link voltage and inverter output voltage through the interactive inverter were controlled. In order to prove the validity of the suggested system, the simulation using PSIM was performed and were reviewed for its validity and stability. The 3[kW] PCS was manufactured and its test was conducted in order to check this situation. In addition, the system characteristics suggested through the test results was verified and the PCS system presented in this study was excellent and stronger than that of before system.

Proof-of-principle Experimental Study of the CMA-ES Phase-control Algorithm Implemented in a Multichannel Coherent-beam-combining System (다채널 결맞음 빔결합 시스템에서 CMA-ES 위상 제어 알고리즘 구현에 관한 원리증명 실험적 연구)

  • Minsu Yeo;Hansol Kim;Yoonchan Jeong
    • Korean Journal of Optics and Photonics
    • /
    • 제35권3호
    • /
    • pp.107-114
    • /
    • 2024
  • In this study, the feasibility of using the covariance-matrix-adaptation-evolution-strategy (CMA-ES) algorithm in a multichannel coherent-beam-combining (CBC) system was experimentally verified. We constructed a multichannel CBC system utilizing a spatial light modulator (SLM) as a multichannel phase-modulator array, along with a coherent light source at 635 nm, implemented the stochastic-parallel-gradient-descent (SPGD) and CMA-ES algorithms on it, and compared their performances. In particular, we evaluated the characteristics of the CMA-ES and SPGD algorithms in the CBC system in both 16-channel rectangular and 19-channel honeycomb formats. The results of the evaluation showed that the performances of the two algorithms were similar on average, under the given conditions; However, it was verified that under the given conditions the CMA-ES algorithm was able to operate with more stable performance than the SPGD algorithm, as the former had less operational variation with the initial phase setting than the latter. It is emphasized that this study is the first proof-of-principle demonstration of the CMA-ES phase-control algorithm in a multichannel CBC system, to the best of our knowledge, and is expected to be useful for future experimental studies of the effects of additional channel-number increments, or external-phase-noise effects, in multichannel CBC systems based on the CMA-ES phase-control algorithm.

Study on the cooling water supply method to the cooling water injection nozzle in the steam generator (증기발생기 내 냉각수 분사 노즐로의 냉각수 공급 방법에 관한 연구)

  • Oh, Jeong-hwa;Shin, Min-kyu;Cho, Young-seok;Ko, Young-sung
    • Journal of Aerospace System Engineering
    • /
    • 제14권5호
    • /
    • pp.66-72
    • /
    • 2020
  • In this study, a method for increasing the initial water supply was employed to protect the water injection nozzle by the flame when supplying the water to the steam generator. During the initial steam generator test, the flow rate was controlled by using the only venturi, but cooling water was not supplied to the combustion chamber at the beginning of combustion, thereby resulting in damage to the water nozzle. To solve this problem, a venturi and an orifice were configured in parallel to increase the initial supply flow rate to form a differential pressure between the water manifold and the combustion chamber. Venturi and orifice supply sequences were established through the water flow tests, and combustion tests were conducted for final verification. Consequently, a continuous supply of the cooling water at the beginning of combustion was achieved, and the experiment was successfully performed without damaging the cooling water nozzle.

A Study on characteristic of a double resonant type high frequency inverter using Phase-Shift (Phase-Shift를 이용한 복공진형 고주파 인버터의 특성에 관한 연구)

  • 조규판;김종해;남승식;김동희;노채균;배영호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제14권1호
    • /
    • pp.109-117
    • /
    • 2000
  • A full bridge type double resonant high frequency resonant inverter to give VVVF function in the inverter used as power source of induction heating at high frequency is presented in this paper. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one and this paper also realize the output control of independence irrespective of the switching frequency using Phase-shift. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, the principle of basic operating and the its characteristics are estimated by the parameters, such as switching frequency, the variation of phase angle ($\phi$) of Phase-shift.

  • PDF

Stereo-photogrammetry Analysis for Over-break Control (여굴 제어를 위한 입체사진측량기법 분석)

  • Kim, Byung-Ryeol;Jeong, Min-Su;Jin, Yeon-Ho;Choi, Sung-Oong
    • Explosives and Blasting
    • /
    • 제36권1호
    • /
    • pp.12-19
    • /
    • 2018
  • When an underground limestone mine selects room-and-pillar mining method, in which the stability of mine openings is maintained by leaving safety pillars, the stability of safety pillars is always incompatible with their productivity. Therefore, the engineering decision for stability and productivity is essential. In this study, a progress of excavation faces by conventional blasting pattern has been examined in field for investigating over-break and stereo-photogrammetry method has been applied to this field measurement for improvement of accuracy. Also this result has been reflected instantly to composite blasting pattern by feedback, for minimizing overbreak. Field tests showed the relevant results that $3.5m^2$ in over-break out of $70m^2$ in total excavation face has been decreased, that is 5% of reduction rate in maximum.

Design of a Current Transducer and Over-Current Fault Detection Circuit for Power Strip Applications (멀티 콘센트용 변류기 및 과전류 검출 회로 설계)

  • Kim, Yong-Jae;Kim, Min-Seok;Park, Gyu-Sang;Kim, Jae-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • 제10권8호
    • /
    • pp.921-926
    • /
    • 2015
  • For the over-heat protection purpose in power strip devices, over-current detection/protection circuits, such as bimetal, switching circuit, and microprocessor-based relay circuit, have been widely setup in high-end products. Most of these circuits are connected to the power line in parallel and, thus, they are sensitive to the line voltage and current distortion. Moreover, these protection circuits are often costly and, therefore, it is hard to meet the commercial requirements. A low-cost over-current detection circuit with the contactless current transducer is designed and tested in this paper. The detection circuit is galvanically isolated from the power line and, thus, less sensitive to the line voltage distortion. The experimental results show that the proposed circuit accurately operates despite of its simple structure and low-cost electronic parts.

A Study on the Test Method of RLC Parallel Circuits on the Device-Mounted Electronic Circuit Board (부품이 실장된 전자회로보드의 RLC 병렬회로 검사기법에 대한 연구)

  • Ko Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • 제54권8호
    • /
    • pp.475-481
    • /
    • 2005
  • In the existing ICT technique, the mounted electronic devices on the printed circuit board are tested whether the devices are good or not by comparing and measuring the value of the devices after separating the devices to be tested from around it based on the guarding method. But, in case that resistance, inductor and capacitor are configured as a parallel circuit on the circuit pattern, values for each device can not be measured because the total impedance value of the parallel circuit is measured. Accordingly, it is impossible to test whether the parallel circuit is good or not in case that the measured impedance value is within the tolerance error. Also, it is difficult to identify that which device among R, L and C of the parallel circuit is bad in case that the measured impedance value is out of the tolerance error. Accordingly, this paper proposes a test method which can enhance the quality and productivity by separating and measuring accurately R, L and C components from the RLC parallel circuits on the device-mounted printed circuit board. First, the RLC parallel circuit to be test is separated electrically from around it using three-terminal guarding technique. And then R, L and C values are computed based on the total impedance values and phase angles between voltage and current of the parallel circuit measured from two AC input signals with other frequency, Finally, the availability and accuracy of the proposed test method is verified by reviewing the simulation results.