• Title/Summary/Keyword: 변형된 중간값 위너 필터

Search Result 2, Processing Time 0.018 seconds

Efficiency of Median Modified Wiener Filter Algorithm for Noise Reduction in PET/MR Images: A Phantom Study (PET/MR 영상에서의 팬텀을 활용한 노이즈 감소를 위한 변형된 중간값 위너필터의 적용 효율성 연구)

  • Cho, Young Hyun;Lee, Se Jeong;Lee, Youngjin;Park, Chan Rok
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.225-229
    • /
    • 2021
  • The digital image such as medical X-ray and nuclear medicine field mainly contains noise distribution. The noise degree in image degrades image quality. That is why, the noise reduction algorithm is efficient for medical image field. In this study, we confirmed effectiveness of application for median modified Wiener filter (MMWF) algorithm for noise reduction in PET/MR image compared with median filter image, which is used as conventional noise redcution algorithm. The Jaszczak PET phantom was used by using 18F solution and filled with NaCl+NiSO4 fluids. In addition, the radioactivity ratio between background and six spheres in the phantom is maintained to 1:8. In order to mimic noise distribution in the image, we applied Gaussian noise using MATLAB software. To evlauate image quality, the contrast to noise ratio (CNR) and coefficient of variation (COV) were used. According to the results, compared with noise image and images with MMWF algorithm, the image with MMWF algorithm is increased approximately 33.2% for CNR result, decreased approximately 79.3% for COV result. In conclusion, we proved usefulness of MMWF algorithm in the PET/MR images.

Usefulness of Median Modified Wiener Filter Algorithm for Noise Reduction in Liver Cirrhosis Ultrasound Image (간경변 초음파 영상에서의 노이즈 제거를 위한 Median Modified Wiener Filter 알고리즘의 유용성)

  • Seung-Yeon Kim;Soo-Min Kang;Youngjin Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.911-917
    • /
    • 2023
  • The method of observing nodular changes on the liver surface using clinical ultrasonography is useful for diagnosing cirrhosis. However, the speckle noise that inevitably occurs in ultrasound images makes it difficult to identify changes in the liver surface and echo patterns, which has a negative impact on the diagnosis of cirrhosis. The purpose of this study is to model the median modified Wiener filter (MMWF), which can efficiently reduce noise in cirrhotic ultrasound images, and confirm its applicability. Ultrasound images were acquired using an ACR phantom and an actual cirrhotic patient, and the proposed MMWF algorithm and conventional noise reduction algorithm were applied to each image. Coefficient of variation (COV) and edge rise distance (ERD) were used as quantitative image quality evaluation factors for the acquired ultrasound images. We confirmed that the MMWF algorithm improved both COV and ERD values compared to the conventional noise reduction algorithm in both ACR phantom and real ultrasound images of cirrhotic patients. In conclusion, the proposed MMWF algorithm is expected to contribute to improving the diagnosis rate of cirrhosis patients by reducing the noise level and improving spatial resolution at the same time.