Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

A Study on Assessment of MTF Performance and Theoretical Analysis of Convex Trial Lenses (볼록 검안렌즈의 MTF 성능 분석 및 이론적 해석에 대한 연구)

  • Bang, Hyun Jin;Lee, Jong Ung;Son, Byung Ho;Ahn, Kyo Hoon;Choi, Eun Jung
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.217-223
    • /
    • 2013
  • White light MTF(Modulation Transter Function)s of biconvex trial lenses from 10 to 20 diopter (D) were represented as a function of angular frequency and visual acuity, and then they were compared with AIM(Aerial Image Modulation) curves. All of the biconvex trial lenses evaluated in on-axis mode had MTF performance that could resolve Landolt's ring up to visual acuity 2.0. However, in a half field angle of five degrees, the trial lens of 10 diopters was able to resolve Landolt's ring up to visual acuity 0.9, and that of 20 diopter only up to visual acuity 0.8. This means that the trial lenses in the case of a half field angle of five degrees do not have sufficient resolution to measure visual acuity by 1.0.

MTF and wavefront error testing of large aperture optical system using unequal path interferometer (경로길이 불일치 간섭계를 이용한 대구경 광학계의 MTF 측정과 파면오차 검사)

  • Song, Jong-Sup;Jo, Jae-Heung;Lee, Yun-Woo;Song, Jae-Bong;Yang, Ho-Soon;Lee, In-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.50-55
    • /
    • 2005
  • A method for measuring the wavefront error and the modulation transfer function(MTF) of large aperture optics using an unequal path interferometer is presented. A bidirectional shearing interferometer is used for collimation testing of the measurement system. A large aperture Fizeau interferometer with long optical path difference measures the wavefront error of the optics under test by using a $\Phi$ 400 mm off-axis parabolic mirror. The MTF is also measured at the wavelength of the interferometer by changing the laser light into partially incoherent light. Test results of a $\Phi$ 300 mm Cassegrain type satellite telescope made in Korea are presented.

위성 영상 탑재체에 관련된 영상품질 인자의 특성

  • Cho, Young-Min
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.66-74
    • /
    • 2002
  • The characteristics of the satellite image quality parameters driven by satellite imaging instrument are investigated. Since the satellite image is directly produced by the satellite imaging instrument, the satellite image quality depends on the imager performance highly. This is why the imager performance parameters are considered as an important part of the satellite image quality parameters. The imager performance parameters consist of spectral band parameters, ground sample distance(GSD) parameters, swath width parameters, imager Modulation Transfer Function (MTF), imager Signal to Noise Ratio(SNR), radiometric response characteristics parameters, pixel registration, and imager calibration.

  • PDF

Evaluation of the Performance Characteristic for Mammography by Using Edge device (유방영상에서 엣지를 이용한 물리적 영상 평가)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Lee, Eul-Kyu;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.415-420
    • /
    • 2016
  • The purpose of this study was to evaluation of the performance characteristic for mammography by using edge device that mammography equipment improves essential in the correct diagnosis for the maintenance. We measured the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using the 61267 RQA-M2 based on commission standard international electro-technical commission (IEC). As a results, spatial resolution of elenia demensions tomo and lorad selenia mammography were maintained at $10mm^{-1}$ and NPS and DQE including the low nyquist frequency indicated to $6.0mm^{-1}$. Therefore, regulary QA of mammography system should be necessary. This study can be contribute to evaluate QA for performance characteristic of mammography of DDR system.

Evaluation of Dose Reduction and Maintaining Image Quality according to Exposure Factors of Cone Beam Computed Tomography (콘빔전산화단층촬영에서 노출 조건에 따른 화질 유지 및 선량 감소에 대한 평가)

  • Han, Jin-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.353-360
    • /
    • 2020
  • This research aims at suggesting exposure condition that shows maintaining the value of the physical image quality factor by decreasing tube voltage and tube current from the standard exposure condition(80 kV, 7 mA) of a CBCT apparatus. To measure the value of the physical image quality factor, modular transfer function(MTF) was analyzed and dose-area product(DAP) was used for the measurement of exposure dose. CBCT images of a Sedentex IQ phantom were obtained under 15 exposure conditions of different combination of tube voltage(80, 78, 76 kV) and tube current(7, 6, 5, 4, 3 mA) and MTF 10 was calculated under each exposure conditions. There were no significant differences in MTF 10 under 80 kV-6 mA, 80 kV-5 mA exposure conditions in comparison with standard exposure condition. Based on the results of this research, 80 kV-5 mA condition are expected to be able to reduce exposure dose with maintaining the value of the physical image quality factor of the standard exposure condition.

Quantitative Analysis of Spatial Resolution for the Influence of the Focus Size and Digital Image Post-Processing on the Computed Radiography (CR(Computed Radiography)에서 초점 크기와 디지털영상후처리에 따른 공간분해능의 정량적 분석)

  • Seoung, Youl-Hun
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.407-414
    • /
    • 2014
  • The aim of the present study was to carry out quantitative analysis of spatial resolution for the influence of the focus size and digital image post-processing on the Computed Radiography (CR). The modulation transfer functions of an edge measuring method (MTF) was used for the evaluation of the spatial resolution. The focus size of X-ray tube was used the small focus (0.6 mm) and the large focus (1.2 mm). We evaluated the 50% and 10% of MTF for the enhancement of edge and contrast by using multi-scale image contrast amplification (MUSICA) in digital image post-processing. As a results, the edge enhancement than the contrast enhancement were significantly higher the spatial resolution of MTF 50% in all focus. Also the spatial resolution of the obtained images in a large focus were improved by digital image processing. In conclusion, the results of this study should serve as a basic data for obtain the high resolution clinical images, such as skeletal and chest images on the CR.

A Study on the Method of Evaluating Optical-system Performance and an Athermal Structure through Thermal Analysis of the Korsch Telescope (Korsch 망원경의 열분석을 통한 광학계 성능 평가 방법 및 비열화 구조 연구)

  • Kim, Kyu-Ho;Park, Seong-Woo;Park, Seung-Han;Lee, Kyoung-Mook;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.266-275
    • /
    • 2021
  • In this paper, a method for evaluating optical-system performance and an athermal structure through thermal analysis of the Korsch telescope was studied. In the case of an optical system having a complex asymmetrical structure, there is a limit to implementing the satellite structure by applying the coefficient of thermal expansion (CTE) in the optical-design software, so it is difficult to evaluate the performance of the optical system against temperature changes. To solve this problem, using mechanical design software all length changes were implemented in all structures that affect the optical system according to temperature, and the value of the change in distance between optical components due to temperature change was organized. Also, the values of changes in shape and thickness of the optical components against temperature changes are organized in the optical-design software. All changes derived from both software packages were applied in the optical software to evaluate the performance of the optical system. As a result, it was found that the MTF for a spatial resolution of 71.4 cycles/mm was maintained at more than 25% in the range from 9 ℃ to 33 ℃. In addition, the performance of the optical system applying the improved structure was evaluated, by finding the structure that had the most influence on the optical system's performance change, and deriving an athermal structure to reduce the effect. As a result, it was found that the MTF for a resolution of 71.4 cycles/mm was maintained at over 67% in the range from 9 ℃ to 33 ℃.

Evaluation of Resolution Characteristics by Using Chart Device Angle (차트 각도를 이용한 해상력 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.375-380
    • /
    • 2021
  • This study aim was quantitative assessment of MTFs of spectrum of the square wave chart images and Coltman chart images for 0°, 1.7°, 2.2°, 2.9°, 4.1° by using chart method. In general device was AccuRay-650 (DK Medical System, Korea) used, indirect flat panel detector(FPD) Aero (Konica, Japan) used and MATLAB R2019a (MathWorks, USA) used. The result of comparison for each angle of MTF the edge image was highest quantitatively value for MTF finding of showed the best value of 0.1 based on the frequency of 3.5 mm-1, value of 0.1 based on the square wave was frequency of 3.0 mm-1 and value of 0.1 based on the Coltman transform was frequency of 2.4 mm-1. In this study it was significant that the methodology of the international Electro-technical Commission was applied mutandis by using the Fujita method within 2~3°.

Image Quality Evaluation of Digital X-Ray Detector Using Amorphous Selenium Layer and Amorphous Silicon TFT Array (비정질 셀레늄층과 비정질 실리콘TFT배열을 사용하는 디지털 X-선 검출기의 영상특성 평가)

  • Kim, Chang-Won;Yoon, Jeong-Key;Kim, Jong-Hyo
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.219-226
    • /
    • 2008
  • In this study, we have conducted characterization of imaging performance for a flat panel digital X-ray detector using amorphous Selenium and a-Si TFT which was developed by the authors. The procedures for characterization were in concordance with internationally recommended standards such as IEC (international electrotechnical commission). The measures used for imaging performance characterization include response characteristic, modulation transfer function (MTF), detective quantum efficiency (DQE), noise power spectrum (NPS), and quantum limited performance. The measured DQEs at lowest and highest spatial frequencies were 40% and 25% respectively, which was superior to that of commercial products by overseas vendor. The MTF values were significantly superior to that of CR and indirect type DRs. The quantum limited performance showed the detector was limited by quantum noise at the entrance exposure level below 0.023 mR, which is sufficiently low for general X-ray examination.