• Title/Summary/Keyword: 변위분석

Search Result 2,157, Processing Time 0.039 seconds

Clinecal Investigation and Acute Complications of Remodelling Plasty of Costochondral Rib Cage For Pectus Excavatum (전흉벽 늑연골의 리모델링 성형술을 이용한 누두흉수술의 임상적 고찰 초기합병증)

  • Her, Keun;Song, Cheol-Min;Jeon, Cheol-Woo;Jang, Won-Ho;Kim, Hyun-Jo;Jeong, Yoon-Seop;Youm, Wook
    • Journal of Chest Surgery
    • /
    • v.35 no.12
    • /
    • pp.882-889
    • /
    • 2002
  • Acute Complications of Remodelling Plasty of Costochondral Rib Cage For Pectus excavatum Recently, Remodelling Plasty of Costochondral Rib Cage has been introduced as an minimally invasive procedure and expanded its application for pectus excavatum. Outcomes and acute complications were reviewed Material and Method: A retrospective survey of 55 patients who underwent Remodelling Plasty of Costochondral Rib Cage from September, 1999 to February, 2002 was conducted to review complications, postoperative treatments, and outcomes. Result: Age ranged from 1 to 27 years(mean 11.4 $\pm$ 7.1). 35(64%) were less than 15-year old and 20(36%) were more than 15-year old. There were 44(80%) Male patients and 11(20%) female patients. Length of hospital stay was 7.8 $\pm$ 2.1 days for less than 15-Y-old group, 10.6 $\pm$ 6.2 days for more than 15-Y-old group(p = 0.042) One substernal bar was inserted in 52 patients and two substernal bars were inserted in 3 patients. As for stabilizer, one lateral side was fastened in 15 patients and both lateral sides were fastened in 6 patients. In the less than 15-Y-old group, 4 patients needed stabilizer, whereas in the more than 15-Y-old group, 18 patients needed stebilizer(s)(p = 0.000). Including all kinds of complications, 28(51 %)patients had postoperative complications. Of them, only 7 patients were treated for complications(C-tube insertion was done in 7 patients and reoperation for bar refixation or removal was done in 3 patients of them). Conclusion: Most complications after Remodelling Plasty of Costochondral Rib Cage For Pectus Excavatum were trivial without treatment although C-tube drainage was needed in some patients. However bar displacement such as rotation and lateral sliding should be corrected as soon as detected in order not to remove the bar(the worst situation).

Evaluation of the Usefulness of the Self-developed Kw-infrared Reflective Marker in Non-coplanar Treatment (비동일면 치료 시 자체 제작한 Kw-infrared Reflective Marker의 유용성 평가)

  • Kwon, Dong-Yeol;Ahn, Jong-Ho;Park, Young-Hwan;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: In radiotherapy that takes into account respiration using a RPM (Real time Position Management, Varian, USA) system, which can treat in consideration of the movement of tumor, infrared reflective markers supplied by manufacturers cannot obtain respiratory signal if the couch rotates at a certain angle or larger. In order to solve this problem, the author developed the 3D infrared reflective marker named 'Kw-marker' that can obtain respiratory signal at any angle, and evaluate its usefulness. Materials and Methods: In order to measure the stability of respiratory signal, we put the infrared reflective marker on the 3D moving phantom that can reproduce respiratory movement and acquired respiratory signal for 3 minutes under each of 3 conditions (A: $couch\;0^{\circ}$, a manufacturer's infrared reflective marker B: $couch\;0^{\circ}$, Kw-marker C: $couch\;90^{\circ}$, Kw-marker). By analyzing the respiratory signal using a breath analysis program (Labview Ver. 7.0), we obtained the peak value, valley value, standard deviation, variation value, and amplitude value. In order to examine the rotation error and moving range of the target, we placed a B.B phantom on the 3D moving phantom, and obtained images at a couch angle of $0^{\circ}$ and $90^{\circ}$ using OBI, and then acquired the X, Y and Z values (mm) of the ball bearing at the center of the B.B phantom. Results: According to the results of analyzing the respiratory signal, the standard deviation at the peak value was A: 0.002, B: 0.002 and C: 0.003, and the stability of respiration for amplitude was A: 0.15%, B: 0.14% and C:0.13%, showing that we could get respiratory signal stably by using the Kw-marker. When the couch rotated $couch\;90^{\circ}$, the mean rotation error of the ball bearing, namely, the target was X: -1.25 mm, Y: -0.45 mm and Z: +0.1 mm, which were within 1.3 mm on the average in all directions, and the difference in the moving range of the target was within 0.3 mm. Conclusion: When we obtained respiratory signal using the Kw-marker in non-coplanar treatment where the couch rotated, we could acquire respiratory signal stably and the Kw-marker was effective enough to substitute for the manufacturer's infrared reflective marker. When the rotation error and moving range of the target were measured, there was little difference, indicating that the displacement of the reflector movement in couch rotation is the cause of change in the scale and amplitude of respiratory signal. If the converted value of amplitude height according to couch angle is studied further and applied, it may be possible to perform non-coplanar phase-based gating treatment.

  • PDF

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON PRODUCED DURING RETRACTION OF FOUR MAXILLARY INCISORS (상악 4절치의 후방견인시 나타나는 현상에 관한 유한요소법적 분석)

  • Cheon, Ok-Jin;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.525-541
    • /
    • 1995
  • This study was designed to investigate force systems and tooth movements produced by retraction archwire during retraction of four maxillary incisors after the maxillary canine retraction into the maxillary first premolar extraction space using the computer-aided three-dimensional finite element method. A three-dimensional finite element model, consisting of 2248 elements and 3194 nodes, was constructed. The model consisted of maxillary teeth and surrounding periodontal membranes, .022'$\times$.028'-slot brackets, and 5 types of retraction archwires(.019'$\times$.025' stainless steel archwire) modeled using the beam elements. The contact between the wire and the bracket slot was modeled using the gap elements because of the non-linear elastic behaviors of the contact between them. The forces and moments, End displacements produced by retraction archwire were measured at various conditions to investigate the difference according to types of loops, magnitudes of activation force, gable angle, and anterior lingual root torque. The results were expressed quantitative and visual ways in the three-dimensional method. The following conclusions can be drawn from this study.1. When the tear-drop loop archwire was activated, the mesio-distal and lingual translational movements of the teeth helped to close the extraction space, but unwanted movements of the teeth including intrusions and extrusions, and rotational movements in each direction occurred. 2. Activation of T-loop archwire compared with those of other types of retraction archwires produced the least translational movements of the teeth helped to space closure and also the least unwanted movements of the teeth. 3. Increasing amount of activation in the tear-drop archwire led not only to increase of translational movements of the teeth helped to space closure, but also to increase of unwanted movements of the teeth. 4. Addition of gable bend in the tear-drop archwire helped anterior teeth to translational movements in the mesio-distal direction, but increased unwanted movements of the teeth 5. Addition of anterior lingual root torque in the tear-drop archwire helped central and lateral incisor to improve their facio-lingual inclination, but increased unwanted movements of the teeth.

  • PDF

Evaluation of Tensions and Prediction of Deformations for the Fabric Reinforeced -Earth Walls (섬유 보강토벽체의 인장력 평가 및 변형 예측)

  • Kim, Hong-Taek;Lee, Eun-Su;Song, Byeong-Ung
    • Geotechnical Engineering
    • /
    • v.12 no.4
    • /
    • pp.157-178
    • /
    • 1996
  • Current design methods for reinforced earth structures take no account of the magnitude of the strains induced in the tensile members as these are invariably manufactured from high modulus materials, such as steel, where straits are unlikely to be significant. With fabrics, however, large strains may frequently be induced and it is important to determine these to enable the stability of the structure to be assessed. In the present paper internal design method of analysis relating to the use of fabric reinforcements in reinforced earth structures for both stress and strain considerations is presented. For the internal stability analysis against rupture and pullout of the fabric reinforcements, a strain compatibility analysis procedure that considers the effects of reinforcement stiffness, relative movement between the soil and reinforcements, and compaction-induced stresses as studied by Ehrlich 8l Mitchell is used. I Bowever, the soil-reinforcement interaction is modeled by relating nonlinear elastic soil behavior to nonlinear response of the reinforcement. The soil constitutive model used is a modified vertsion of the hyperbolic soil model and compaction stress model proposed by Duncan et at., and iterative step-loading approach is used to take nonlinear soil behavior into consideration. The effects of seepage pressures are also dealt with in the proposed method of analy For purposes of assessing the strain behavior oi the fabric reinforcements, nonlinear model of hyperbolic form describing the load-extension relation of fabrics is employed. A procedure for specifying the strength characteristics of paraweb polyester fibre multicord, needle punched non-woven geotHxtile and knitted polyester geogrid is also described which may provide a more convenient procedure for incorporating the fablic properties into the prediction of fabric deformations. An attempt to define improvement in bond-linkage at the interconnecting nodes of the fabric reinforced earth stracture due to the confining stress is further made. The proposed method of analysis has been applied to estimate the maximum tensions, deformations and strains of the fabric reinforcements. The results are then compared with those of finite element analysis and experimental tests, and show in general good agreements indicating the effectiveness of the proposed method of analysis. Analytical parametric studies are also carried out to investigate the effects of relative soil-fabric reinforcement stiffness, locked-in stresses, compaction load and seepage pressures on the magnitude and variation of the fabric deformations.

  • PDF

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

Analysis of Shoreline Changes from Aerial Photographs at Oregon Inlet Terminal Groin (Oregon 하구에 위치한 방사제 주위에서의 항공사진을 이용한 해안선 변화해석)

  • Hwang, Kyu-Nam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.9 no.3
    • /
    • pp.155-164
    • /
    • 1997
  • A comprehensive and systematic field monitoring program was initiated since October 1989, in order to investigate the temporal and spatial variation of shoreline position at northern part of Pea Island, North Carolina. Aerial photographs were taken every two months on the shoreline extending from the US Coast Guard Station at the northern end of Pea Island to a point 6 miles to the south. Aerial photographs taken were digitized initially to obtain the shoreline position data. in which a wet-dry line visible on the beach was used to identify the position of shoreline. Since the wet-dry line does not represent the “true" shoreline .position but includes the errors due to the variations of wave run-up heights and tidal elevations at the time the photos taken, it is required to eliminate the tide and wave runup effects from the initially digitized shoreline .position data. Runup heights on the beach and tidal elevations at the time the aerial photographs taken were estimated using tide data collected at the end of the FRF pier and wave data measured from wave-rider gage installed at 4 km offshore, respectively A runup formula by Hunt (1957) was used to compute the run-up heights on the beach from the given deepwater wave conditions. With shoreline position data corrected for .wave runup and tide, both spatial and temporal variations of the shoreline positions for the monitoring shoreline were analyzed by examining local differences in shoreline movement and their time dependent variability. Six years data of one-mile-average shoreline indicated that there was an apparent seasonal variation of shoreline, that is, progradation of shoreline at summer (August) and recession at winter (February) at Pea Island. which was unclear with the uncorrected shoreline position data. Determination of shoreline position from aerial photograph, without regard to the effects of wave runup and tide, can lead to mis-interpretation for the temporal and spatial variation of shoreline changes.nges.

  • PDF

Study for the Conservation Treatment of the Stele for National Preceptor Hongbeop from the Jeongtosa Temple Site in Chungju (충주 정토사지 홍법국사탑비의 보존과학적 연구)

  • Chae, Woomin;Hwang, Hyunsung
    • Conservation Science in Museum
    • /
    • v.19
    • /
    • pp.1-18
    • /
    • 2018
  • The Stele for National Preceptor Hongbeop from the Jeongtosa Temple site in Chungju is one of the most important stone cultural heritage items for exemplifying the style of the Goryeo era. Despite its obvious value, this relic has been stored in a weathered condition at the National Museum of Korea. It had suffered various dismantling and displacements during the Japanese colonial period and had long been exposed in the open air. The stele was selected as a subject for the Stone Monuments Restoration Project launched by the National Museum of Korea in 2015. In preparation for its outdoor exhibition as part of the restoration project, this study investigated the characteristics of its materials, produced a map of its deterioration from weathering, and carried out ultrasonic analysis of the materials to provide findings useful for conservation treatment. The materials analysis revealed that the turtle-shaped pedestal of the stele was made from two-mica granite consisting of medium-grained quartz, plagioclase, alkali feldspar, biotite, and muscovite. Its body stone is crystalline marble, the rock-forming mineral in which is medium-grained calcite in a rose-pink color with dark grey spots. The dragon top of the stele is made of crystalline marble, the major component of which is medium-grained calcite of a light-grey color. The deterioration consists of 21.5% abrasion on the stone body, with its south face most damaged, and 18.6% granular disintegration, with the north face most damaged. The ultrasonic material characterization conducted for mapping the general condition of weathering shows low values on the parts-assembly area of the turtle-shaped pedestal and on the upper portion of the stone body. It is considered that there is dislocation due to partial blistering and fracturing as well as to the differences in surface treatment. Prior to the outdoor exhibition of the stele, the surface was cleaned of contaminants and was consolidated based on the scientific investigation in order to prevent weathering from the external environment.

Evaluation of Manufactured Device for Radiation therapy in Head and Neck Cancer (두경부암 환자의 방사선 치료시 자체 제작한 고정용구 (Shoulder Retractor)에 대한 유용성 평가)

  • Kim, Tae Jun;Jin, Sun Sik;Kim, Dong Hyun;Kim, Dong Wook;Chung, Weon Kuu;Kim, Kyoung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.99-105
    • /
    • 2014
  • Purpose : We compared the set-up accuracy and right-left Shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Materials and Methods : Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. Results : The position variation correction of left (right) Shoulder after image guidance were $1.07{\pm}3.99mm$ ($-4.35{\pm}2.09mm$), $-0.37{\pm}5.91mm$ ($1.26{\pm}5.28mm$), $-0.63{\pm}2.44mm$ ($0.25{\pm}1.61mm$) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were $-2.06{\pm}2.68$, $-1.11{\pm}8.15$, $0.34{\pm}3.78mm$, and $0.51{\pm}0.77$ degree for group A, $-1.18{\pm}1.82$, $-0.94{\pm}2.13$, $-0.67{\pm}1.98mm$, and $0.91{\pm}1.04$ degree for group B and $0.12{\pm}2.18$, $-0.79{\pm}2.64$, $0.79{\pm}2.64$, and $0.00{\pm}0.49$ degree for group C. Conclusion : In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment.

A study of lower facial change according to facial type when virtually vertical dimension increases (가상적 수직 교합 고경 증가 시 안모의 유형에 따른 하안모 변화에 관한 연구)

  • Kim, Nam-Woo;Lee, Gung-Chol;Moon, Cheol-Hyun;Bae, Jung-Yoon;Kim, Ji-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the effect of increased vertical dimension of occlusion on lower facial changes by facial type. Materials and methods: Lateral cephalograms from 261 patients were obtained and classified by sagittal (Class I, II, and III) and vertical (hypodivergent, normodivergent, and hyperdivergent) facial patterns. Retrusive displacement of soft tissue Pogonion and downward displacement of soft tissue Menton were measured in each group after 2 mm of vertical dimension of occlusion was increased at the lower central incisor using a virtual simulation program. The ratio of both displacements was calculated in all groups. The statistical analysis was done by 2-way ANOVA and Post hoc was done by Tukey test (5% level of significance). Results: Retrusive displacement of soft tissue Pogonion in Class III group was statistically different compared to Class I and II, and in vertical facial groups all 3 groups were significantly different (P<.05). Downward displacement of soft tissue Menton showed statistically significant difference between all sagittal groups and vertical groups (P<.05). The ratio of both displacements showed statistically significant difference in all sagittal groups and vertical groups (P<.05), and Class II hyperdivergent group had the highest value. Conclusion: Lower facial change was statically significant according to the facial type when vertical dimension of occlusion increased. Class II hyperdivergent facial type showed the highest ratio after increase in vertical dimension of occlusion.

THE CHANGE OF CANAL CONFIGURATION AFTER INSTRUMENTATION BY SEVERAL NICKEL-TITANIUM FILES IN THE SIMULATED CANAL WITH ABRUPT CURVATURE (수종의 엔진구동형 니켈-타이타늄 파일에 의한 급한 만곡의 근관 성형시 근관형태 변화에 대한 비교연구)

  • Lim, Jung-Jang;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.303-311
    • /
    • 2005
  • The purpose of this study was to evaluate which type of Ni-Ti files are able to maintain canal configuration better in the simulated canal with abrupt curvature near it's apex. Ninety six simulated root canals were made in epoxy resin and $\sharp$15 finger spreader was used as root canal templates. The simulated root canals were made with radius of curvature of 1.5mm, 3.0mm, 4.0mm, 6.0mm respectively and the angle of curvature of all simulated canals were adjusted to 90 degree. The simulated canals were instrumented by ProFile, ProTaper, Hero 642, and $K^3$ at a 300 rpm using crown-down pressureless technique. Pre-instrumented and post-instrumented images were taken by digital camera and were superimposed with Adobe Photos hop 6.0 program. Images were compared by image analysis program. The changes of canal width at the inner and outer side of the canal curvature. canal transportation were measured at 9 measuring point with 1 mm interval. Statistical analysis among the types of Ni-Ti files was performed using Kruskal-Wallis test and Mann-Whitney U-test. The result was that ProFile maintain original canal configuration better than other engine driven Ni-Ti files in the canals above 3.0mm radius of curvature, and in the 1.5mm radius of curvature, most of Ni-Ti flies were deformed or separated during instrumentation.