• Title/Summary/Keyword: 변연골 흡수량

Search Result 20, Processing Time 0.021 seconds

Retrospective study on marginal bone resorption around immediately loaded implants (즉시 하중 임플란트에서 변연골 흡수량에 관한 후향적 연구)

  • Lee, Sung-Hoon;Jung, Ji-Hye;Lee, Jin-Han;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.114-119
    • /
    • 2018
  • Purpose: Patients who treated implant immediate loading within a week after implant placement at Wonkwang University Dental Hospital Implant Center were evaluated marginal bone resorption. These retrospective analyses are intended to reinforce the clinical evidence for the implant immediate loading. Materials and methods: Medical history and radiographic data were investigated, which were the patients' who treated implant immediate loading and restoration with provisional prostheses between January 2005 and June 2016, at Wonkwang University Dental Hospital Implant Center. Total number of implants was 70, marginal bone resorption was measured according to implant length, diameter and connection type. To measure marginal bone resorption, periapical radiographs were taken when the implants were placed and after 6 month. Statistical analysis was done in Mann-whitney U test and Kruskal-wallis test with SPSS 22.0 software (P<.05). Results: Mean marginal bone resorption around immediately loaded implants according to implant connection type was shown $1.24{\pm}0.72mm$ in internal hexagon connection type and $1.73{\pm}1.27mm$ in external hexagon connection type. There was no statically significant difference in marginal bone resorption with implant length and diameter. Conclusion: Implants with immediated loading in internal hexagon connection type showed less marginal bone resorption significantly than in external hexagon connection type.

Retrospective study of the $Implantium^{(R)}$ implant with a SLA surface and internal connection with microthreads (SLA 표면 처리와 미세나사선을 가진 내측 연결형의 국산 임플란트에 대한 후향적 연구)

  • Doh, Re-Mee;Moon, Hong-Suk;Shim, Jun-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.136-147
    • /
    • 2009
  • Statement of problem: Since the introduction of the concept of osseointegration in dental implants, high long-term success rates have been achieved. Though the use of dental implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. Purpose: The aim of this retrospective study was to provide long-term data on the $Implantium^{(R)}$ implant, which features a sandblasted and acid-etched surface and internal connection with microthreads. Material and methods: 106 $Implantium^{(R)}$ implants placed in 38 patients at Yonsei University Hospital were examined to determine the effect of various factors on implant success and marginal bone loss, through clinical and radiographic results during a 6 to 30 month period. Results: 1. Out of a total of 106 implants placed in 38 patients, one fixture was lost, resulting in a 99.1% cumulative survival rate. 2. Among the 96 implants which were observed throughout the study period, the survival rates were 97.0% in the maxilla and 100% in the mandible. The survival rate in the posterior regions was 98.9% and 100% in the anterior regions. 3. The mean bone loss during the first year after prosthesis placement was 0.17 mm, while the mean annual bone loss after the first year was 0.04 mm, which was statistically less than during the first year(P<.05). 4. There was no significant difference in marginal bone loss according to age during the first year(P>.05), but after the first year, the mean annual bone loss in patients above 50 years was significantly greater(P<.05) compared with patients under 50 years. 5. No significant difference in marginal bone loss was found according to the following factors: gender, jaw, location in the arch, type of implant(submerged or non-submerged), presence of bone grafts, type of prostheses, and type of opposing dentition(P<.05). Conclusion: Based on these results, the sole factor influencing marginal bone loss was age, while factors such as gender, jaw, location in the arch, type of implant, presence of bone grafts, type of prostheses and type of opposing dentition had no significant effect on bone loss. In the present study, the success rate of the $Implantium^{(R)}$ implant with a SLA surface and internal connection with microthreads was satisfactory up to a maximum 30 month period, and the marginal bone loss was in accord with the success criteria of dental implants.

Success rate and marginal bone loss of Osstem USII plus implants; Short term clinical study (Osstem USII plus 임플란트의 단기간 성공률 및 변연골 흡수량 평가)

  • Kim, Sun-Keun;Kim, Jee-Hwan;Lee, Keun-Woo;Cho, Kyoo-Sung;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.206-213
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the clinical value of Osstem$^{(R)}$ USII plus system implants. Clinical and radiographic data were analyzed for 88 implants placed and functionally loaded for a 12 month period at the Yonsei University Dental Hospital. Materials and Method: Based on the patient's medical records, clinical factors and their effects on implant marginal bone resorption, distribution and survival rate were analyzed. The marginal bone loss was evaluated at implant placement and during a 6 to 12 months functional loading period. The independent sample t-test was used to evaluate the interrelationship between the factors (${\alpha}$=0.05), and one way repeated measures ANOVA was used to compare the amount of marginal bone resorption. Results: The cumulative survival rate for 88 implants was 100%. The marginal bone resorption from implant placement to prosthetic delivery was 0.24 mm and the average marginal bone resorption from prosthetic delivery to 12 months of functional loading was 0.19 mm. The total average bone resorption from implant placement to 12 months of functional loading was 0.43 mm. There were no statistically differences in the amount of marginal bone resorption when implants were placed in the maxilla or the mandible (P>.05), however, implants placed in the posterior areas showed significantly more marginal bone loss than those placed in the anterior areas (P<.05). Conclusion: Based on these results, the short term clinical success rate of RBM surface treated external connection domestic implants showed satisfactory results and the marginal bone loss was in accord with the success criteria of dental implants.

Clinical Study on the Survival Rate and Marginal Bone Resorption of Short Implants (짧은 임플란트의 생존율과 변연골 흡수량에 관한 임상적 연구)

  • Myung, Tae-Soo;Jung, Seung-Hyun;Kim, Tae-Young;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • Short implants are used in parts which have anatomical structures like maxillary sinus, inferior alveolar nerve and limited alveolar height due to severe alveolar bone resorption. In these case, there are no need of additional bone augmentation so there are advantages like reduced entire treatment time, reduced patient's discomfort and protection of important anatomical structures. The aim of this study is, in implants whose length is less than 10mm, to analyze the impact of implant length, diameter, location of implant placement, presence of bone graft, presence of prosthesis splinting on survival rates and marginal bone resorption. The samples used in this study were 227 implants, less than 10mm, placed in 137 patients in Wonkwang university dental hospital implant center. From dental charts the information about implant length, diameter, location of implant placement, presence of bone graft, presence of prosthesis splinting were obtained. Emago advanced v5.6(Oral diagnostic systems, Amsterdam, The Netherlands)program was used to measure the amount of marginal bone resorption. Out of total 227 implants, resulting in 96.5 % of survival rate. There was a tendency toward higher failure rates for the maxilla and bone graft site. No significant difference in marginal bone resorption was found associated with length of implants(p>0.05) and neither with the diameter of implants. Among the risk factors examined, more failure rates of short implants can be attributed to poor bone quality in the maxilla and presence of bone graft. At implants under 10mm, length, diameter, location of implant placement, bone graft and splinting of prosthesis didn't affect marginal bone loss.

Early Marginal Bone Loss around Submerged Implants According to the Patterns of Cover Screw Exposures (Submerged 임플란트에서 덮개나사 노출 양상에 따른 조기 변연골 상실)

  • Choi, Mee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.175-182
    • /
    • 2013
  • The purpose of this study was to observe and analyze the initial marginal bone resorption changes according to the patterns of cover screw exposures during healing period followed by implants installation. Total 64 fixtures(TiUniteTM, NobelBiocare, Sweden) were installed in partially edentulous jaws of 28 patients, who were selected retrospectively and were shown at least one cover screw exposure. Cover screw exposures were defined at 1 month recall. According to the patterns of exposures, groups were categorized into group 1 (No exposure), group 2 (pin-point exposure), group 3 (less than 1/2 of cover screw), group 4 (more than 1/2 of cover screw), group 5 (total exposure). Periapical radiographs were taken in purpose of changes of marginal bone level between installation and 2 month recall. Healing abutments were secured on the exposure groups at 2 month recall. Results were as follows: 1. Marginal bone resorptions were identified whenever cover screws were exposed. 2. Group 2 and 3 were shown significantly increased bone loss more than other group (P <.05). 3. Group 4 and 5 were shown significantly increased bone loss more than group 1, however, less than other groups ( P <.05). Conclusionally, cover screw exposure may cause marginal bone resorptions, therefore, early connection of healing abutment is clinically helpful.

The success rate of Mg-incorporated oxidized implants in partially edentulous patients: a prospective clinical study (부분 무치악 환자에서 마그네슘 이온주입 임플란트의 성공률에 대한 전향적 임상연구)

  • Choi, Su-Jung;Yoo, Jung-Ho;Lee, Ku-Bok;Kim, Jin-Wook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.176-183
    • /
    • 2012
  • Purpose: This study examined the clinical success rate of Mg titanate implants (M Implant system, Shinhung, Korea), which employ a Mg coating method, by evaluating the marginal bone loss and implant stability using radiographs and Osstell$^{(R)}$, over a 1 year. Materials and methods: The locations of the implants placement were divided into 4 areas; the maxillary and mandibular premolars and molars. In the maxilla, 8 and 9 implants were inserted in the premolar and molar areas, respectively. In the mandible, 11 and 51 implants were inserted in the premolar and molar areas. Marginal bone loss and ISQ of all implants (79) were measured after insertion, mounting the prosthetic appliance, and 1, 3, 6, and 12 months after loading. The marginal bone loss was measured from the radiograph using XCP bite, which was customized, and the implant stability measured using Osstell$^{(R)}$. Fisher's exact test (${\alpha}$=.05) was used to compare the success rates of each region. Results: The mean marginal bone loss for the upper and lower jaws were 1.537 mm and 1.172 mm. The mobility showed a non-significant reduction or increase according with time. The success rates were accounted for 94.12% and 98.39% in the upper and lower jaws; the premolars and molars were accounted for 100% and 96.67%. The two cases of early failure resulted from failure of primary stability during implant insertion. The late failures were not observed for 1 year after adding a loading to the implants. Conclusion: The Mg titanate implant showed good primary stability and good clinical results in both healing and function.

Effects of implant collar design on marginal bone and soft tissue (임플란트의 collar design이 변연골과 연조직에 미치는 영향)

  • Yoo, Hyun-Sang;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.21-28
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the effects of implant collar design on marginal bone change and soft tissue response by an animal test. Materials and methods: Two types of Implant (Neobiotech Co. Seoul, Korea) that only differs in collar design were planted on two healthy Beagle dogs. The implants were divided into two groups, the first group with a beveled collar (Bevel Group) and the second group with "S" shaped collar (Bioseal group). Standardized intraoral radiographs were used to investigate the mesio-distal change of the marginal bone. Histological analysis was done to evaluate the bucco-lingual marginal bone resorption and the soft tissue response adjacent to the implant. Mann-Whitney test was done to compare the mesio-distal marginal bone change at equivalent time for taking the radiographs and the tissue measurements between the groups. Results: Radiographic and histological analysis showed that there was no difference in marginal bone change between the two groups (P>.05). Histological analysis showed Bioseal group had more rigid connective tissue attachment than the Bevel group. There was no difference in biological width (P>.05). Bevel group showed significantly longer junctional epithelium attachment and Bioseal group showed longer connective tissue attachment (P<.05). Conclusion: For three months there were no differences in marginal bone change between the Bevel group and the Bioseal group. As for the soft tissue adjacent to the implant, Bioseal group showed longer connective tissue attachment while showing shorter junctional epithelium attachment. There were no differences in biologic width.

Clinical and radiographic evaluation of $Neoplan^{(R)}$ implant with a sandblasted and acid-etched surface and external connection (SLA 표면 처리 및 외측 연결형의 국산 임플랜트에 대한 임상적, 방사선학적 평가)

  • An, Hee-Suk;Moon, Hong-Suk;Shim, Jun-Sung;Cho, Kyu-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.125-136
    • /
    • 2008
  • Statement of problem: Since the concept of osseointegration in dental implants was introduced by $Br{{\aa}}nemark$ et al, high long-term success rates have been achieved. Though the use of dental implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. Purpose: The aim of this retrospective study was to provide long-term data on the $Neoplan^{(R)}$ implant, which features a sandblasted and acid-etched surface and external connection. Material and methods: 96 $Neoplan^{(R)}$ implants placed in 25 patients in Yonsei University Hospital were examined to determine the effect of the factors on marginal bone loss, through clinical and radiographic results during 18 to 57 month period. Results: 1. Out of a total of 96 implants placed in 25 patients, two fixtures were lost, resulting in 97.9% of cumulative survival rate. 2. Throughout the study period, the survival rates were 96.8% in the maxilla and 98.5% in the mandible. The survival rates were 97.6% in the posterior regions and 100% in the anterior regions. 3. The mean bone loss for the first year after prosthesis placement and the mean annual bone loss after the first year for men were significantly higher than that of women (P<0.05). 4. The group of partial edentulism with no posterior teeth distal to the implant prosthesis showed significantly more bone loss compared to the group of partial edentulism with presence of posterior teeth distal to the implant prosthesis in terms of mean bone loss for the first year and after the first year (P<0.05). 5. The mean annual bone loss after the first year was more pronounced in posterior regions compared to anterior regions (P<0.05). 6. No significant difference in marginal bone loss was found in the following factors: jaws, type of prostheses, type of opposing dentition, and submerged /non-submerged implants (P<0.05). Conclusion: On the basis of these results, the factors influencing marginal bone loss were gender, type of edentulism, and location in the arch, while the factors such as arch, type of prostheses, type of opposing dentition, submerged / non- submerged implants had no significant effect on bone loss. In the present study, the cumulative survival rate of the $Neoplan^{(R)}$ implant with a sandblasted and acid-etched surface was 97.9% up to a maximum 57-month period. Further long-term investigations for this type of implant system and evaluation of other various domestic implant systems are needed in future studies.

Retrospective Study of GS II Implant(Osstem) with an Internal Connection with Microthreads (Micro thread를 포함한 GSII RBM임플란트(Osstem)의 후향적 임상연구)

  • Chee, Young-Deok;Lee, Jae-Hwan;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.417-429
    • /
    • 2009
  • Since the introduction of the concept of osseointegration in dental implants, high long-term success rates have been achieved and accepted as viable option for the treatment of fully and partially edentulous patients. Although the use of domestic implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. 96 endosseous implants placed in 31 patients at Wonkwang University Sanbon Dental Hospital were examined to determine the effect of various factors on implant survival rate and marginal bone loss, through clinical and radiographic results. The design of endosseous implant used to this study is straight with the microthread.(GS II RBM Fixture) 1. 3 fixtures were lost, resulting in 96.9% cumulative survival rate. 2. Survival rate in fifties was significantly lower (93.6%) and no significant difference in marginal bone loss was found according to gender. 3. Survival rates were 95.6% in the maxillary molar area and 97.3% in the mandible molar area. 4. No significant difference in survival rate was found according to presence of bone grafts, type of prostheses, implant position, and length and diameter of implant. 5. A factor influencing marginal bone loss was presence of type of prostheses, while facters such a length, diameter of fixture and bone grafts had no statistically significant effect on crestal bone loss. This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

A Prospective Clinical Trial on the Mg Oxidized Clinical Implants (마그네슘 양극산화 임플란트의 성공률에 관한 전향적 임상연구)

  • Im, So-Min;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra;Um, Heung-Sik;Lee, Jae-Kwan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.25-39
    • /
    • 2011
  • In animal studies, Magnesium (Mg) - incorporated oxidized implants showed significant enhancement of the bone response. This prospective clinical trial was performed to investigate the success rate, implant stability and marginal bone loss of Mg oxidized clinical implant. The experimental protocol was approved by Institutional Review Board of the Gangneung-Wonju National University Dental Hospital. Fifty healthy patients had partial edentulism were included in this study. Mg oxidized clinical implants (Implant M, Shinhung, Korea) were installed and restored with conventional protocol. The patients were recalled at 1, 3, 6 months after functional loading. Implant stability quotient (ISQ) was measured and periapical radiographic images were obtained. Amount of marginal bone loss was calculated with calibrated images from periapical radiographs. Repeated measured analysis of variance and post hoc Tukey test were used to compare the mean ISQ and bone level. A total of 101 implants were analyzed. The mean ISQ values increased continuously with time lapse from 68.4 at fixture installation to 71.5 at 6 months after loading. Implant stability was correlated with gender, fixture diameter, bone quality and implant sites. The mean marginal bone loss during 6 months after loading was 0.26 mm. There was no failed implant and six-month success rate was 100%. Within the limitations of this study, the six-month success rate of Mg oxidized implant was satisfactory. The implant stability and marginal bone level were excellent. However, further longer clinical studies will be needed to confirm the success of Mg oxidized clinical implant.