• Title/Summary/Keyword: 변성치매

Search Result 3, Processing Time 0.018 seconds

Utility of Brain SPECT in Diagnosis of Elderly Depressed Patient (노인 우울증 환자의 진단에서 뇌 SPECT의 효율성)

  • Kim, Young-Chul
    • Sleep Medicine and Psychophysiology
    • /
    • v.1 no.2
    • /
    • pp.193-196
    • /
    • 1994
  • Primary depression with cognitive impairment, referred to as depressive pseudodementia, may be mistaken for a progressive degenerative dementia. Recognition of primary depression is clinically important because of its treatability. To differentiate depression from degenerative dementia, author used brain SPECT. By the result the regional cerebral blood flow(rCBF) in elderly depressed patient was decreased in the right frontal cortex. The pattern of rCBF was different from that of dementia which shows decreased rCBF in bifrontal cortex. By using brain SPECT in depressed elderly patient with cognitive impairment, the discrimination from dementia will be more effective and accurate.

  • PDF

Relationship between White Matter Changes and Homocysteine Concentration in Healthy Adults (건강한 성인에서 대뇌 백질 변성과 호모시스테인 농도의 연관성)

  • Hur, Wook;Kang, Hyun Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.449-455
    • /
    • 2018
  • This study was conducted to analyze the correlation between changes in white matter and homocysteine concentration through brain computed tomography of healthy 50-75 year old subjects without stroke or dementia history. We studied 722 out of 900 patients who underwent health screening at one hospital from 2016 to 2017. Based on the medical records, retrospective studies were conducted and analyzed using SPSS. A chi-square test, T-test and univariate logistic regression analysis were used for analysis. After the subjects were divided into the group with and without white matter changes, the population characteristics were analyzed. The mean age, homocysteine concentration and prevalence of hypertension and diabetes were higher and the duration of education was shorter in the group with white matter changes. In the group with white matter changes, the population increased as homocysteine concentration increased. When the odds ratio was compared based on the lowest group (Q1), age [p<0.001], hypertension [p<0.001] and hyperhomocysteinemia [p=0.021] were risk factors for white matter changes. We also identified modifiable risk factors such as hypertension and hyperhomocysteinemia to prevent complications of white matter changes. However, there has been no report of risk for the each causes of hyperhomocysteinemia and relationship between white matter changes and homocysteine concentration in Koreans. Therefore, large scale prospective studies are needed to better understand this topic.

Facile [11C]PIB Synthesis Using an On-cartridge Methylation and Purification Showed Higher Specific Activity than Conventional Method Using Loop and High Performance Liquid Chromatography Purification (Loop와 HPLC Purification 방법보다 더 높은 비방사능을 보여주는 카트리지 Methylation과 Purification을 이용한 손쉬운 [ 11C]PIB 합성)

  • Lee, Yong-Seok;Cho, Yong-Hyun;Lee, Hong-Jae;Lee, Yun-Sang;Jeong, Jae Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.67-73
    • /
    • 2018
  • $[^{11}C]PIB$ synthesis has been performed by a loop-methylation and HPLC purification in our lab. However, this method is time-consuming and requires complicated systems. Thus, we developed an on-cartridge method which simplified the synthetic procedure and reduced time greatly by removing HPLC purification step. We compared 6 different cartridges and evaluated the $[^{11}C]PIB$ production yields and specific activities. $[^{11}C]MeOTf$ was synthesized by using TRACERlab FXC Pro and was transferred into the cartridge by blowing with helium gas for 3 min. To remove byproducts and impurities, cartridges were washed out by 20 mL of 30% EtOH in 0.5 M $NaH_2PO_4$ solution (pH 5.1) and 10 mL of distilled water. And then, $[^{11}C]PIB$ was eluted by 5 mL of 30% EtOH in 0.5 M $NaH_2PO_4$ into the collecting vial containing 10 mL saline. Among the 6 cartridges, only tC18 environmental cartridge could remove impurities and byproducts from $[^{11}C]PIB$ completely and showed higher specific activity than traditional HPLC purification method. This method took only 8 ~ 9 min from methylation to formulation. For the tC18 environmental cartridge and conventional HPLC loop methods, the radiochemical yields were $12.3{\pm}2.2%$ and $13.9{\pm}4.4%$, respectively, and the molar activities were $420.6{\pm}20.4GBq/{\mu}mol$ (n=3) and $78.7{\pm}39.7GBq/{\mu}mol$ (n=41), respectively. We successfully developed a facile on-cartridge methylation method for $[^{11}C]PIB$ synthesis which enabled the procedure more simple and rapid, and showed higher molar radio-activity than HPLC purification method.