• Title/Summary/Keyword: 벨크로

Search Result 17, Processing Time 0.063 seconds

Research on the Actual Condition of Shape and Material of Peanut-Shaped Cloth Diaper for Baby (유아용 땅콩형 천기저귀의 형태 및 소재에 관한 실태 조사)

  • Lee, Jung-Soon;Koo, Mi-Ran
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.12 no.3
    • /
    • pp.57-71
    • /
    • 2010
  • This study is to understand the actual condition of design and material of peanut-shaped diaper with looking at the types and characteristics of baby cloth diapers and domestic peanut-shaped diapers registered in the Patent Office. Furthermore, it is to suggest the basic data for designing more functional and comfortable cloth diapers. Here are the research result on the actual condition of design and material of baby cloth diapers. Firstly, 11 cloth diapers registered in the Patent Office can be divided into panty-shaped and straight line-shaped diapers. There are 7 kinds of panty-shaped cloth diapers which satisfy both the convenience of a disposable diaper and sanitation of a cloth diaper, and 4 kinds of straight line-shaped cloth diapers that minimize the weaknesses of existing cloth diapers. Secondly, domestic peanut-shaped cloth diapers can be divided into peanut-shaped, inserted, winged, velcro-attached diapers. Among 23 kinds of peanut-shaped cloth diapers from 16 companies, there are 12 kinds of peanut-shaped diapers which consist of layers of cloth to make peanut shape. There are 6 kinds of inserted diapers that insert extra diapers or handkerchiefs in between two sheets of cloth diapers and 3 kinds of winged diapers designed to shorten drying time with sawing only one side of several layered sheets. Also, there are 2 kinds of velcro-attached diapers that are removable according to the amount of excreta. Commonly used materials are cotton woven of diamond jacquard and knit of diamond Hole Stitch or Plain Stitch. And for handing the edge of diaper, the method of wrapping up the edge with cotton woven or knit bias is used.

  • PDF

Optical Network Monitoring System Using Smart Phone (스마트 폰을 이용한 광 통신망 감시 시스템)

  • Jung, So-Ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.1
    • /
    • pp.218-226
    • /
    • 2017
  • In this paper, optical transport network in real time monitoring system using smart phone. The existing housing using monitoring was a smart phone of optical transport network access switch about an event with new installation of cognitive system in real time. This paper can this problem to be solved of the invention in real time maintenance using smart phone application and optical cable closure switch. If you want to find optical cable closure fault location, this smart phone web is very useful. Cable tie is isolation of fiber spare board from fiber switch tie occur push message. Housing and access, and an external failures otdr the measurement of the global positioning to be able to easily using the This paper can find event of optical cable closure unauthorized work and fault using smart phone OTDR function. the optical cable fault time reduction and network transport quality by managing real time optical cable section by using the smart phone can be maintained efficiently.

Adaptive Clothing Designs for the Individuals with Special Needs (지체 장애인을 위한 개호복 디자인)

  • Na, Hyun-Shin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.6 s.165
    • /
    • pp.933-941
    • /
    • 2007
  • Nowadays the numbers of the disabled and elderly have been increasing, and the development of adaptive clothing for these people is in demand. The purpose of this study was to give ideas and solutions for the special needs clothing design. The knowledge of medical situation of the individuals with special needs has been examined and factors affecting adaptive clothing were suggested. Twenty-one web sites were investigated and the most practical, functional, fashionable adaptive clothes were suggested by items. Construction and location of openings, number and type of fastenings, and design of garments for comfort and ease of movement were carefully considered in these clothes. Better appearance through improvement of clothing will help these people to believe that they have worth in the sight of others and in their own view of themselves. Disabled and elderly can obtain the quality of life, maintain the dignity, and make the access to the world a little bit easier by solving the particular clothing problems with all these convenient as well fashionable adaptive clothing.

A Study on how to Utilize the DR System using Assistive Devices (보조기구를 이용한 DR System 활용 방법에 대한 연구)

  • Seon-Yeol, Seo;Jeong-Ho, Kim;Jin-Ok, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.115-122
    • /
    • 2023
  • The hip joint device is an important immobilization device for internal rotation in the diagnosis of bone density test, microfracture, and arthritis. These fixing mechanisms have limitations in maintaining reproducibility due to the use of Velcro. In this study, we developed an improved hip joint device and evaluated its usefulness. For 30 students enrolled in the Department of Radiology, we evaluated the reproducibility through medical imaging and the time required for positioning by applying the conventionaling and improved device. Changes over time were also evaluated. As a result, compared to the conventional device, the improved device showed a 32% reduction in positioning time and improved reproducibility by about 6.2 times. As for the amount of change over time, the positioning time increased in the conventional device, but decreased in the improved device, and the reproducibility of the conventional device was lower than that of the improved device. Through this, it can be said that the use of the improved device improved the image quality and reduced the radiologist's workload.

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

Development of Abdominal Compression Belt and Evaluation of the Efficiency for the Reduction of Respiratory Motion in SBRT (체부 정위방사선치료 시 호흡운동 감소를 위한 복부 압박기구 개발 및 유용성 평가)

  • Hwang, Seon-Bung;Kim, Il-Hwan;Kim, Woong;Im, Hyeong-Seo;Gang, Jin-Mook;Jeong, Seong-Min;Kim, Gi-Hwan;Lee, Ah-Ram;Cho, Yu-Ra
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.13-19
    • /
    • 2011
  • Purpose: It's essential to minimize the tumor motion and identify the exact location of the lesions to achieve the improvement in radiation therapy efficiency during SBRT. In this study, we made the established compression belt to reduce respiratory motion and evaluated the usefulness of clinical application in SBRT. Materials and Methods: We analyzed the merits and demerits of the established compression belt to reduce the respiratory motion and improved the reproducibility and precision in use. To evaluate the usefulness of improved compression belt for respiratory motion reduction in SBRT, firstly, we reviewed the spiral CT images acquired in inspiration and expiration states of 8 lung cancer cases, respectively, and analyzed the three dimensional tumor motion related to respiration. To evaluate isodose distribution, secondly, we also made the special phantom using EBT2 film (Gafchronic, ISP, USA) and we prepared the robot (Cartesian Robot-2 Axis, FARARCM4H, Samsung Mechatronics, Korea) to reproduce three dimensional tumor motion. And analysis was made for isodose curves and two dimensional isodose profiles with reproducibility of respiratory motion on the basis of CT images. Results: A respiratory motion reduction compression belt (Velcro type) that has convenient use and good reproducibility was developed. The moving differences of three dimensional tumor motion of lung cancer cases analyzed by CT images were mean 3.2 mm, 4.3 mm and 13 mm each in LR, AP and CC directions. The result of characteristic change in dose distribution using the phantom and rectangular coordinates robot showed that the distortion of isodose has great differences, mean length was 4.2 mm; the differences were 8.0% and 16.8% each for cranio-caudal and 8.1% and 10.9% each for left-right directions in underdose below the prescribed dose. Conclusion: In this study, we could develop the convenient and efficient compression belt that can make the organs' motion minimize. With this compression belt, we confirmed that underdose due to respiration can be coped with when CTV-PTV margins of mean 6 mm would be used. And we conclude that the respiratory motion reduction compression belt we developed can be used for clinical effective aids along with the gating system.

  • PDF

Development of a Finger Tactile Stimulator Based on E-Prime Software (E-Prime에 기반한 손가락 촉각 자극기의 개발)

  • Kim, Hyung-Sik;Min, Yoon-Ki;Kim, Bo-Seong;Min, Byung-Chan;Yang, Jae-Woong;Lee, Su-Jeong;Choi, Mi-Hyun;Yi, Jeong-Han;Tack, Gye-Rae;Lee, Bong-Soo;Jun, Jae-Hoon;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.703-710
    • /
    • 2010
  • In this study, a tactile stimulator was developed to resolve some problems from the previous version of the system such as system configuration, inappropriate stimulation control and additional problems. The developed tactile stimulator consists of control unit, drive unit and vibrator unit. The control unit was controlled by E-Prime software to generate appropriate vibration pulses. The drive unit supplies enough energy to the vibrator to generate effective stimulation pulses. The vibrator unit consists of small coin type vibrator and velcro, and was made to be attached at the hand easily. The developed tactile stimulator was designed by small-size, light-weight, low-power, simple-fabrication, max 35 channels and little delay time from instruction signal of E-Prime software to vibrator. The duration and magnitude of stimulation was controlled by 10 grades and the problems concerning stimulation control were compensated by wideband frequency ranges. Additionally, the electrical safety was ensured by low voltage operation. Vibrator was made to be attached on finger as well as on any part of the subject. Since this tactile stimulator is developed based on E-Prime software which is widely used in cognitive science, it is believed that this stimulator be suitable for the wide application of cognitive science study.

  • PDF