• Title/Summary/Keyword: 번호이동성

Search Result 118, Processing Time 0.028 seconds

A Study on Test Report Information Service Architecture for Preventing Forgery and Alteration in Defense Industry (군수품 시험성적서 위·변조 방지 시스템 아키텍처에 대한 연구)

  • Lee, Donghun;Jeon, Sooyune;Bae, Manjae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.43-51
    • /
    • 2016
  • Preventing the forgery and alteration of test reports is important, in order to maintain the reliability of military supplies. Based on a survey of reports on testing institutions and a case study of established electronic document systems in the public sector, we propose a system architecture, which helps prevent the forgery and alteration of test reports with legal force. The proposed architecture takes advantage of both the time stamp that records the time a document is received and a server synchronized with the testing institution. Using the proposed system architecture, the user is able to request a test and receive reports from the testing institution without delay. Also, a defense agency is able to conveniently prove the authenticity of the test reports and utilize the statistical data collected by the architecture. Therefore, we expect that the proposed system architecture will help defense agencies to prevent the forgery and alteration of test reports and ensure their reliability and quality.

핵융합로 부품에 대한 고열유속 시험조건 결정

  • Bae, Yeong-Deok;Lee, Dong-Won;Kim, Seok-Gwon;Yun, Jae-Seong;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.273-273
    • /
    • 2010
  • 고열부하 환경에 노출되는 핵융합로의 플라즈마 대향부품은 주로 낮은 원자번호 물질-열전도가 좋은 물질-구조체의 순으로 다층 구조를 이루고 있으며, 이들 간의 우수한 접합성은 부품의 성능을 좌우하는 핵심 요소이다. 이러한 플라즈마 대향부품의 건전성을 평가하기 위해서는 고열속의 열부하를 반복적으로 인가하는 시험이 요구되며, 이를 위해 본 연구원에서는 KoHLT-1, 2의 시험시설을 운용하고 있다. 본 시설에서는 열부하원으로서 그라파이터 히터를 사용하며, 히터는 두 개의 시험 대상부품 사이에 설치되고, 히터에 고전류를 인가하여 복사열에 의해 시험 부품에 열부하를 가하게 된다. 고열부하 환경에서 열피로 시험을 위해 히터에 인가되는 전류를 시간에 따라 일정한 패턴으로 반복적으로 ON-OFF 하게 된다. 본 논문에서는 이러한 고열부하시험을 수행함에 있어 고려해야 할 여러 가지 요소에 대해 논의하였다. 우선 인가하는 열유속(heat flux) 값은 일차적으로 시험시설의 최대 출력에 의해 좌우되며, 시험대상물의 운전조건 및 열부하 반복횟수에 의해 결정된다. 열부하 반복횟수는 주어진 열유속 값에 대해 total strain이 파단에 이르는 수준에 의해 결정된다. 열부하를 인가하는 시간은 히터에 전류를 인가했을 때 요구되는 온도로 상승하는 데 걸리는 시간과 시험대상물의 온도가 더 이상 증가하지 않는데 걸리는 시간에 의해 좌우된다. 냉각시간은 길수록 시험대상물의 온도가 냉각수의 온도에 접근하게 되나 너무 길어지면 시험시간이 급격히 증가하게 되므로, 온도 감소 곡선을 검토하여 적절한 시간을 정하게 된다. 열유속 측정은 냉각수의 온도 상승값과 유량으로부터 계산하게 되며, 정확한 측정을 위해서는 열부하를 인가하는 시간이 충분히 길어야 한다. 또한 시험대상 부품에서 열부하가 인가되는 면적을 정확히 정의해야 하며, 냉각관로에 열부하가 인가되어서는 않된다. 또한 시험대상부품을 지지하는 지지구조체를 통한 열손실을 최소화해야 정확한 열유속을 측정할 수 있다. 시험대상부품을 설치할 때 히터와의 간격 또한 결정해야 할 중요한 요소이며, 간격이 좁을수록 최대 열유속 값을 증가시킬 수 있으나, 너무 가까운 경우 히터의 열변형에 의한 접촉 및 아크 방전의 가능성이 있으며, 이 경우 히터와 시험대상부품의 손상을 가져오게 된다. 시험대상물이 국제열핵융합로(ITER)의 일차벽과 같이 베릴륨이 포함되어 있는 경우 방전에 의한 손상은 인체에 유해한 오염의 원인이 될 수 있다. 또한 순간적인 방전은 고가의 고전류전원의 고장을 유발할 수도 있다. 열부하 시험 중 시험대상물의 온도를 정확히 측정하는 것은 필수적이며, 온도 변화 곡선으로부터 시험대상물의 건전성 여부를 판단할 수 있다. 이를 위해 변화를 가장 잘 탐지 할 수 있는 위치에 온도 센서를 설치하는 것이 관건이며, 이는 사전 분석을 통해 알 수 있다.

  • PDF

Macrocyclic Complexes of Actinide and Lanthanide Metals (Ⅰ). Formation and Properties of Cation Complexes with Macrocyclic Ligands (악틴 및 란탄족금속의 거대고리 착물 (제 1 보). 거대고리 리간드의 금속착물의 형성과 성질)

  • Jeong, O Jin;Choe, Chil Nam;Yun, Seok Jin;Son, Yeon Su
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.143-158
    • /
    • 1990
  • Metal complexes were prepared by reacting uranium (Ⅵ), thorium (Ⅳ) and rare earth metal (Ⅲ) ions including Nd (Ⅲ), Sm (Ⅲ) and Ho (Ⅲ) with macrocyclic ligands including five crown ethers, nine crownands and one cryptand ligands, and subjected to NMR studies in order to examine coordination sites of the ligands and compositions of the complexes formed. Among the marcocyclic ligands, crown ethers and crownand ligands have shown down-field shifts of the methylene protons of the lcigands by forming stable complexes with all the metal ions and the differences of chemical shifts were decreased as increasing of the cavity-size of crown ethers for the same metal ions and decreasing of the atomic number of the rare earth metals for the same ligands. It has been found that crownand 22 gave a stable complex with uranium(Ⅵ) ion by the coordination through both oxygen and nitrogen atoms of the ligand whereas no complex was formed with the rare earth metal(Ⅲ) ions, which on the other hand were found to form stable complexes with cryptand 221. The rest of the crowand ligands have also been found to form stable complexes with uranium(Ⅵ) ion by coordinating through all the oxygen and nitrogen atoms of the ligands whereas no complexes were formed with the rare earth metal(Ⅲ) ions. It has also been shown by 1H-NMR study that uranium(Ⅵ), thorium(Ⅳ) and rare earth metal(Ⅲ) ions formed 1:1 complexes with the macrocyclic ligands except for thorium(Ⅳ) complex of 12C4 in which the mole ratio of metal to ligand is 1:2. More stable metal complexes show larger changes in chemical shifts of the coordinated ligand protons. Finally, the rare earth metal(Ⅲ) complexes of 18C6 have shown ligand exchange reaction with the solvent molecules in acetylacetone solution, which was not observed for the uranium (Ⅵ) complexes.

  • PDF

Analysis of the Photon Beam Characteristics by Medical Linear Accelerator According to Various Target Materials using MCNP-code (MCNP-code를 이용한 의료용 선형가속기의 타깃 재질에 따른 광자선 특성 분석)

  • Lee, Dong-Yeon;Park, Eun-Tae;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.197-203
    • /
    • 2017
  • This study purpose is propose the basic data for selecting the optimal target material by analyzing the photon characteristics of various materials which was located in the head of medical linear accelerator. In this study, energy spectrum of 6, 15 MV photon beams were compared and analyzed for 13 target materials using MCNPX of Monte Carlo method. The mean energy for the 6 MV energy spectrum was 1.69 ~ 1.84 MeV and that for the 15 MV was 3.38 ~ 3.56 MeV, according to the target material. The flux for the 6 MV energy spectrum was $1.64{\times}10^{-5}{\sim}1.80{\times}10^{-5}{\sharp}/cm^2/e$ and that for the 15 MV was $1.76{\times}10^{-4}{\sim}1.85{\times}10^{-4}{\sharp}/cm^2/e$. The analysis shows that the average energy and flux increase with higher atomic number of the target material. Based on this study, it is possible to present the basic data about the physical characteristics of the photon, and it will be possible to select the target later considering economic, efficiency and physical aspect.

A Mobile Payment System Based-on an Automatic Random-Number Generation in the Virtual Machine (VM의 자동 변수 생성 방식 기반 모바일 지급결제 시스템)

  • Kang, Kyoung-Suk;Min, Sang-Won;Shim, Sang-Beom
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.12 no.6
    • /
    • pp.367-378
    • /
    • 2006
  • A mobile phone has became as a payment tool in e-commerce and on-line banking areas. This trend of a payment system using various types of mobile devices is rapidly growing, especially in the Internet transaction and small-money payment. Hence, there will be a need to define its standard for secure and safe payment technology. In this thesis, we consider the service types of the current mobile payments and the authentication method, investigate the disadvantages, problems and their solutions for smart and secure payment. Also, we propose a novel authentication method which is easily adopted without modification and addition of the existed mobile hardware platform. Also, we present a simple implementation as a demonstration version. Based on virtual machine (VM) approach, the proposed model is to use a pseudo-random number which is confirmed by the VM in a user's mobile phone and then is sent to the authentication site. This is more secure and safe rather than use of a random number received by the previous SMS. For this payment operation, a user should register the serial number at the first step after downloading the VM software, by which can prevent the illegal payment use by a mobile copy-phone. Compared with the previous SMS approach, the proposed method can reduce the amount of packet size to 30% as well as the time. Therefore, the VM-based method is superior to the previous approaches in the viewpoint of security, packet size and transaction time.

The Complete Amino Acid Sequence of Newborn Dog Prochymosin (강아지 프로카이모신의 전 아미노산 서열)

  • Yoon, Joo-Ok;Kim, Hyun-Ku
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.7 no.3
    • /
    • pp.289-300
    • /
    • 1997
  • Newborn dog chymosin was extracted from the stomachs of dogs of 2 weeks of age, and was purified by ion exchange chromatography. Half of the sequence was determined by amino acid sequencing and the complete sequence was deduced from a cloned chymosin cDNA Results showed that the zymogen showed 79% sequence identity with calf prochymosin and 54% identity with porcine pepsinogen A The size of the propart and location of the residue which becomes the amino-terminus in the active enzyme was the same in the prochymosins. The maximum general proteolytic activity at pH 3.2 of newborn dog chymosin was 3-4% of that of porcine pepsin A at pH 2, whereas the milk clotting activity relative to the general proteolytic activity of newborn dog chymosin was much higher than that of calf chymosin. Agar gel electrophoresis at pH 5.2 of stomach extracts of individual dogs showed the existence of two predominant genetic variants of zymogen and enzyme. The two variants could not be distinguished by amino acid composition or amino-terminal sequencing, and no differences in the enzymatic properties of the genetic variants were observed. It was concluded that of the residues that participate in the substrate binding, calf and newborn dog chymosin differ in the following positions (porcine pepsin numbering, subsites in parentheses) : Ser 12 Thr(S$_4$), Leu 30 Val(S$_1$/S$_3$), His 74 Gln(S'$_2$), Val 111 Ile(S$_1$/S$_3$), Lys 220 Met(S$_4$). With regard to the low general proteolytic activity of newborn dog chymosin, the substitution Asp303 Val relative to calf chymosin may contribute to an explanation of this.

  • PDF

Genetic Expression of Color Approved by Color Qualities of Munsell System on the Cocoon of Silkworm, Bombyx mori (누에 고치색 유전자 발현의 다양성 검정 및 색채과학적 해석)

  • Han, Myung-Sae;Park, Hyun-Ro;Han, Sang-Mi;Nam, Ki-Soo;Kwon, Soon-Ha;Lim, Jong-Sung;Nguyen, Mau Tuan
    • Journal of Sericultural and Entomological Science
    • /
    • v.41 no.1
    • /
    • pp.20-28
    • /
    • 1999
  • Color qualities investigated on the basis of Munsell code and Korean standard color code for the cocoons from various strain of mulberry silkworm, Bombyx mori. 16 of different color qualities were identified from 21 of original silworm strains, and determinated international name with the revision of Korean color name for cocoon. The various cocoon color confirmed on the sphere from 567 to 593 nm wavelength, 78% of those located at the region about 580 nm (575~584) of sensitive "color difference limen". Y gene engaged broad ranges of wavelength (575~593 nm) in the color expression, by contrast with other genes of Pk (593 nm), F (584~593), Grc and relative G group (567~570 nm), on the transmission of carotenoid or flavonoid color substance. YC gene expression by original silk worm strain was also distinguished by those variation of specific yellow than other colors from Grc, GaGb, Gc, and YPkF. Appearance of chrome yellow cocoon was dominant than other yellow in the cross among vivid yellow group. F1 of pin${\times}$green produced the cocoon of yellow such as "additive mixture" as color light, however, most of the hybrid between yellow cocoon showed the color similar to "subtractive mixture" as a mixture of dyestuff. Hybrid cocoons among yellow or green colors were decreased their hue, value, and chroma, than those of parent. Diallel cross among the strain of various green cocoon suggest the existence of Grc, Ga, Gb, Gc genes. Cream colored cocoon of B. mandarina was differed from other yellow cocoon of Bobyx mori B. mori. Y$^A$ with Ymc showed the similar role of Y with C, therefore, segregated yellow cocoon from the B. mori${\times}$B. mandarina (+$^YC/Y^AYmc$). YC expression of $Y^AY$mc genes might be suppressed by deficiency of outer layer sericin on the middle division of silk giand in the B. mandarina.

  • PDF

Quantitative Differences between X-Ray CT-Based and $^{137}Cs$-Based Attenuation Correction in Philips Gemini PET/CT (GEMINI PET/CT의 X-ray CT, $^{137}Cs$ 기반 511 keV 광자 감쇠계수의 정량적 차이)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Park, Eun-Kyung;Kim, Jong-Hyo;Kim, Jae-Il;Lee, Hong-Jae;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.182-190
    • /
    • 2005
  • Purpose: There are differences between Standard Uptake Value (SUV) of CT attenuation corrected PET and that of $^{137}Cs$. Since various causes lead to difference of SUV, it is important to know what is the cause of these difference. Since only the X-ray CT and $^{137}Cs$ transmission data are used for the attenuation correction, in Philips GEMINI PET/CT scanner, proper transformation of these data into usable attenuation coefficients for 511 keV photon has to be ascertained. The aim of this study was to evaluate the accuracy in the CT measurement and compare the CT and $^{137}Cs$-based attenuation correction in this scanner. Methods: For all the experiments, CT was set to 40 keV (120 kVp) and 50 mAs. To evaluate the accuracy of the CT measurement, CT performance phantom was scanned and Hounsfield units (HU) for those regions were compared to the true values. For the comparison of CT and $^{137}Cs$-based attenuation corrections, transmission scans of the elliptical lung-spine-body phantom and electron density CT phantom composed of various components, such as water, bone, brain and adipose, were performed using CT and $^{137}Cs$. Transformed attenuation coefficients from these data were compared to each other and true 511 keV attenuation coefficient acquired using $^{68}Ge$ and ECAT EXACT 47 scanner. In addition, CT and $^{137}Cs$-derived attenuation coefficients and SUV values for $^{18}F$-FDG measured from the regions with normal and pathological uptake in patients' data were also compared. Results: HU of all the regions in CT performance phantom measured using GEMINI PET/CT were equivalent to the known true values. CT based attenuation coefficients were lower than those of $^{68}Ge$ about 10% in bony region of NEMA ECT phantom. Attenuation coefficients derived from $^{137}Cs$ data was slightly higher than those from CT data also in the images of electron density CT phantom and patients' body with electron density. However, the SUV values in attenuation corrected images using $^{137}Cs$ were lower than images corrected using CT. Percent difference between SUV values was about 15%. Conclusion: Although the HU measured using this scanner was accurate, accuracy in the conversion from CT data into the 511 keV attenuation coefficients was limited in the bony region. Discrepancy in the transformed attenuation coefficients and SUV values between CT and $^{137}Cs$-based data shown in this study suggests that further optimization of various parameters in data acquisition and processing would be necessary for this scanner.