• Title/Summary/Keyword: 버퍼제어

Search Result 476, Processing Time 0.024 seconds

A buffer readout scheduling for ABR traffic control (ABR 트랙픽 제어를 위한 버퍼 readout 스케쥴링)

  • 구창회;이재호
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.11
    • /
    • pp.25-33
    • /
    • 1997
  • The end-to-end rate-based control mechanism is used for the flow control of the ABR service to allow much more flexibility in ATM switching system. To accommodate the ABR service effciently many algorithms such as EFCI, EPRCA, ERICA, and CAPC2 have been proposed for the switch algorithm. ABR cells and related RM cells are received at the ATM switch fabric transparently without any processing. And then cells received from the traffic source are queued in the ABR buffer of switching system. The ABR buffer usually has some thresholds for easy congestion control signal transmission. Whatever we use, therefore, these can be many ABR traffic control algorithms to implement the ABR transfer capability. The genertion of congestion indicate signal for ABR control algorithms is determined by ABR buffer satus. And ABR buffer status is determined by ABR cells transfer ratio in ATM switch fabrics. In this paper, we presented the functional structures for control of the ABR traffic capability, proposed the readout scheduling, cell slot allocation of output link and the buffer allocation model for effective ABR traffic guranteeing with considering CBR/VBR traffics in ATM switch. Since the proposed readout scheduling scheme can provide more avaliable space to ABR buffer than existing readout scheduling scheme, generation rate of a SEND signal, that is, BCN signal in destination node can be increased for ABR call connection. Therefore, the proposed scheme, in this paper, can be appropriate as algorithm for effective ABR traffic service on output link of ATM switching node.

  • PDF

Design and Implementation of Channel Allocation Module of Synchronous Area in MOST Network (MOST 네트워크의 동기영역 채널 할당 모듈 설계 및 구현)

  • Jang, Si-Woong;Kwak, Gil-Bong;Yu, Yoon-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1397-1402
    • /
    • 2010
  • While MOST is an in-vehicle network which transfers concurrently synchronous data, asynchronous data and control data, it provides high bandwidth synchronous section which can transfer video and audio without buffering. To transfer real time data using synchronous section, connections between source node and sink node, and channel allocation for connections are required. In this paper, we proposed synchronous data transfer method and channel allocation method by constructing MOST network after designing and implementing channel allocation module for using synchronous data section.

Design of Triple-Error-Correcting Reed-Solomon Decoder using Direct Decoding Method (Reed-Solomon 부호의 직접복호법을 이용한 3중 오류정정 복호기 설계)

  • 조용석;박상규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8A
    • /
    • pp.1238-1244
    • /
    • 1999
  • In this paper, a new design of a triple-erroe-correcting (TEC) Reed-Solomon decoder is presented based on direct decoding method which is more efficient for the case of relatively small error correction capability. The proposed decoder requires only 9 GF(2m) multipliers in obtaining the error-locator polynomial and the error-evaluator polynomial, whereas other decoders needs 24 multipliers. Thus, the attractive feature of this decoder is its remarkable simplicity from the point of view of implementation. Futhermore, the proposed TEC Reed-Solomon decoder has very simple control circuit and short decoding delay. Therefore this decoder can be implemented by simple hardware and also save buffer memory which stores received sequence.

  • PDF

A Condition (지열원식 냉난방 히트펌프 시스템의 상태 감시 및 열 성능 평가 기술 개발)

  • Koo, Kyung-Wan;Park, Jun-Un;Kang, Byung-Chan;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.322-326
    • /
    • 2009
  • 본 연구는 지열원식 냉난방 히트펌프 시스템의 상태를 실시간으로 감시하고 열 성능을 실시간으로 평가할 수 있도록 한 지열원식 냉난방 히트펌프 시스템의 상태 감시 및 열 성능 평가 방법에 관한 것으로서, 이러한 본 연구는, 프로그램 실행을 통하여 측정 간격이 설정되고, 다이얼로그 박스 상에서 시스템 개요, 공사개요, 히트펌프설비개요, 지열루핑 설비개요, 버퍼탱크, 건물개요 등을 입력받은 후 시스템의 개통도 이미지 파일프로그램 로딩과 각종 계측기를 통해 전기적인 데이터의 취득 기능 등의 데이터측정 준비를 위한 기본 제1단계와; 취득된 전기적인 데이터를 물리 신호로 변환한 후 기본 데이터 산정하고 결과를 도시하는 "시스템 실시간 작동 상태 감시" 기능의 제2단계와; 기본 순간치 데이터를 근거로 "시스템의 열성능 평가 변수 값 산정과 결과"를 도시하는 제3단계와; 2단계에서의 기본 데이터와 3단계에서의 열성능 평가 변수 값을 후처리용 데이터 파일로 저장하는 제4단계와; 현장에 설치된 지열원식 히트펌프 시스템의 상태를 TCP/IP 프로토콜을 활용하여 원격지(본사)에서 IP 접속을 통하여 원거리 원격 작동상태 감시 기능 및 제어를 수행하는 제5단계를 수행하게 된다.

  • PDF

An efficient Hardware Architecture of Lempel-Ziv Compressor for Real Time Data Compression (실시간 데이터 압축을 위한 Lempel-Ziv 압축기의 효과적인 구조의 제안)

  • 진용선;정정화
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.3
    • /
    • pp.37-44
    • /
    • 2000
  • In this paper, an efficient hardware architecture of Lempel-Ziv compressor for real time data compression is proposed. The accumulated shift operations in the Lempel-Ziv algorithm are the major problem, because many shift operations are needed to prepare a dictionary buffer and matching symbols. A new efficient architecture for the fast processing of Lempel-Ziv algorithm is presented in this paper. In this architecture, the optimization technique for dictionary size, a new comparing method of multi symbol and a rotational FIFO structure are used to control shift operations easily. For the functional verification, this architecture was modeled by C programming language, and its operation was verified by running on commercial DSP processor. Also, the design of overall architecture in VHDL was synthesized on commercial FPGA chip. The result of critical path analysis shows that this architecture runs well at the input bit rate of 256kbps with 33MHz clock frequency.

  • PDF

CIGS 박막 태양전지용 하부전극 Mo 박막증착 및 특성

  • Son, Yeong-Ho;Choe, Seung-Hun;Choe, Se-Ho;Jeong, Jin-Bong;Gang, Ho-Jeong;Cheon, Tae-Hun;Kim, Su-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.142-142
    • /
    • 2010
  • 태양광 발전산업에서 현재 주류인 결정 실리콘 태양전지의 변환효율은 꾸준히 향상되고 있으나, 태양전지의 가격이 매년 서서히 하강되고 있는 실정에서 결정질 실리콘 가격의 상승 등으로 부가가치 창출에 어려움이 있으며, 생산 원가를 낮출 수 있는 태양전지 제조기술로는 2세대 태양전지로 불리는 박막형이 현재의 대안이며, 특히 에너지 변환 효율과 생산 원가에서 장점이 있는 것이 CIGS 박막 태양전지로 판단된다. 화합물반도체 베이스인 CIGS 박막 태양전지는 연구실에서는 세계적으로 20.3% 높은 효율을 보고하고 있으며, 모듈급에서도 13% 효율로 생산이 시작되고 있다. 국내에서도 연구실 규모 뿐만 아니라 대면적(모듈급) CIGS 박막 태양전지 증착용 장비, 제조공정 등의 기술개발이 진행되고 있다. CIGS를 광흡수층으로 하는 CIGS 박막 태양전지의 구조는 여러 층의 단위박막(하부전극, 광흡수층, 버퍼층, 앞면 투명전극, 반사방지막)을 순차적으로 형성시켜 만든다. 이 중에 하부전극은 Mo 재료을 스퍼터링 방법으로 증착하여 주로 사용한다. 하부전극은 0.24 Ohm/cm2 정도의 전기적 특성이 요구되며, 주상조직으로 성장하여야 하며, 기판과의 밀착성이 좋아야하고 또한 레이저 패턴시 기판에서 잘 떨어져야 하는 특성을 동시에 가져야 한다. 그리고 CIGS 박막 내에서 Na 도핑을 어떻게 제어할 것인지도 고려해야한다. 본 연구에서는 대면적(모듈급) CIGS 박막 태양전지에서 요구되는 하부전극 Mo 박막의 특성과 기술적 이슈들에 대해서 연구결과들을 논하고자 한다.

  • PDF

Interactive Remote Lecture System Based on IPv6 Multicast Services (IPv6 멀티캐스트 기반의 쌍방향 원격 강의 시스템)

  • Kang, Sung-Ho;Choo, Young-Yeol
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.11
    • /
    • pp.295-301
    • /
    • 2006
  • The scope ID field of IPv6 multicast address indicates the zone of the destination for which a multicast traffic is intended. Without any further examination on the header field, the scope ID enables a router to determine whether the traffic will be forwarded to a subnet or not. For the graceful migration from IPv4 networks to IPv6 networks, various IPv6 applications working through IPv4 networks are indispensable during the migration period. This paper describes development of an interactive remote lecture system providing service integration on voice, image, and data of teaching materials. Access right to the network for dialog among multicast group members is controlled via additional TCP (Transmission Control Protocol) session. A jitter buffer algorithm was implemented to improve the voice communication jitters.

  • PDF

Improved Sensor MAC Protocol for Wireless Sensor Network (무선 센서 네트워크를 위한 향상된 센서 MAC 프로토콜)

  • Lee, Ju-a;Kim, Jae-Hyun;Min, Seung-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.11A
    • /
    • pp.1138-1146
    • /
    • 2006
  • It is very important for the sensor network to save battery capacity. Switching active mode to sleep mode is used for S-MAC protocol and expiring timer before end of the active part is used for T-MAC in order to extend battery life span. We proposed IS-MAC (Improved Sensor MAC) which gives more energy efficiency than S-MAC and T-MAC To improve energy efficiency in sensor network, we used the threshold value in buffer to transmit data packet and proposed the method to reduce the number of control packets which cause extra battery consumption. Based on the analytical results, we found that the proposed IS-MAC protocol shows better performance than conventional MAC protocols.

Design of A Reed-Solomon Decoder for UWB Systems (UWB 시스템 용 Reed-Solomon 복호기 설계)

  • Cho, Yong-Suk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.4C
    • /
    • pp.191-196
    • /
    • 2011
  • In this paper, we propose a design method of Reed-Solomon (23, 17) decoder for UWB using direct decoding method. The direct decoding algorithm is more efficient for the case of relatively small error correction capability. The proposed decoder requires only 9 $GF(2^m)$ multipliers in obtaining the error-locator polynomial and the error-evaluator polynomial, whereas other decoders need about 20 multipliers. Thus, the attractive feature of this decoder is its remarkable simplicity from the point of view of hardware implementation. Futhermore, the proposed decoder has very simple control circuit and short decoding delay. Therefore this decoder can be implemented by simple hardware and also save buffer memory which stores received sequence.

A Study on the QoS of Real-Time Traffic in Bursty Queueing Scheme (버스트 큐잉 구조에서 실시간 트래픽 QoS에 관한 연구.)

  • Kim, Gwang-Joon;Jang, Hyok;Na, Sang-Dong;Bae, Chul-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.401-405
    • /
    • 1999
  • 본 논문은 실시간성 서비스인 버스트 트래픽을 갖는 ATM(Asynchronous Transfer Mode)망에서 실시간 연결 수락 제어를 위한 종단간의 지연보장을 알고리즘을 이용하여 실시간 서비스 트래픽 서비스 품질의 성능에 대해 분석하였다. 셀 손실 확률은 QoS(Quality of Service)의 기준이 되므로 제안된 실시간 알고리즘은 일정한 버퍼 메모리 크기와 연결 요청에 대한 수락 여부 즉, 연결 수락 여부의 결정을 위한 하나의 큐잉 서비스를 필요로 한다. 이러한 트래픽 소스 각 타입에 대한 초과된 셀에 대한 셀 손실 확률은 트래픽 소스 타입 전체에 하나만 존재하더라도 요구를 충족시킬 수 없으므로, 본 논문에서 제안된 버스트 트래픽 특성에 따라 지연보장 알고리즘을 이용한 큐 서비스 방식은 기존의 종단간 지연 보장 알고리즘들에서 사용하던 씬 정렬을 이용하지 않고 몇 개의 FIFO 큐로 구성된 라운드로빈 큐를 이용하여 복잡성을 크게 감소시켰으며 실시간 서비스와 비실시간 서비스의 서비스방식을 효과적으로 결합하여 다양한 QoS를 보장해야 하는 ATM망에 효과적으로 적용할 수 있고 제안된 알고리즘에 산출되는 각각의 셀 손실 확률에 충분한 상한선을 제공하는 전형적인 매개변수를 사용하여 성능을 분석한다.

  • PDF