• Title/Summary/Keyword: 밸브성능

Search Result 558, Processing Time 0.028 seconds

Inducement of Design Parameters for Reliability Improvement of Servo Actuator for Hydraulic Valve Operation (유압밸브 구동용 서보 액추에이터의 신뢰성 향상을 위한 설계 파라미터 도출)

  • Sung, Baek Ju;Kim, Do Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.475-482
    • /
    • 2014
  • The precision hydraulic valve is widely used in various industrial field like aircraft, automobile, and general machinery. Servo actuator is the most important device for driving the precise hydraulic valve. The reliable operation of servo actuator effects on the overall hydraulic system. The performance of servo actuator relies on frequency response and step response according to arbitrary input signal. In this paper, we performed the analysis for the components of servo actuator to satisfy the reliable operation and response characteristics through the reliability analysis, and also induced the design parameters to realize the reliable operation and fast response characteristics of servo actuator for hydraulic valve operation through the empirical knowledge of experts and electromagnetic theories. We suggested the design equations to determine the values of design parameters of servo actuator as like bobbin size, length of yoke and plunger and turn number of coil, and verified the achieved design values through FEM analysis and performance tests using some prototypes of servo actuators adapted in hydraulic valve.

Evaluation of Seismic Performance of Valve Chamber System by Shaking Table Tests (진동대 실험을 통한 밸브실 시스템의 내진성능 평가)

  • Young-Soo Jeong;Kyeong-Seok Lee;Jin-Seok Yu;Hyung-Chae Jeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.46-52
    • /
    • 2024
  • The structural safety of expansion joints for piping systems has been drawing attention owing to ruptures and leaks of water pipes caused by earthquakes and road subsidence at soft ground. In general, metal bellows are installed as expansion joints to prevent various damages in the piping system. In this study, the seismic performance of a valve chamber system was evaluated by performing earthquake shaking table tests. To validate the benefits to structural safety of metal bellows in connecting steel pipes to valve chambers, the seismic tests were conducted on expansion joints (bellows) and general pipping, and the results were compared for durability. Strain gauges were attached to measure the effects of the input motion. As a result of the shaking table test, it was confirmed that the strain of the valve chamber structure and inflow or outflow steel pipes were decreased in 1/100, 1/20 by applied to the expansion joints.

A Study on the Decompression Performance by the Orifice Diameter (오리피스의 직경에 따른 감압성능에 관한 연구)

  • Park, Bong-Rae;Yun, Ki-Jo;Jang, Kyeong-Nam;Choi, Jung-Ung;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.57-63
    • /
    • 2012
  • The modern trend for high-rise buildings makes the application of fire protection systems difficult and the current systems have a limitation to provide appropriate functions. Indoor hydrant systems are fire suppression systems installed in most buildings that require valves, hoses, and nozzles to be manually operated in the event of a fire. Therefore, high discharge pressure can cause difficulty in the operation of indoor fire hydrant systems and damage to hoses due to a high reaction force. To prevent these problems, the pressure is reduced and decompression valves are commonly installed at angle valves which are the discharge points of indoor hydrants. In the case of high-rise buildings, however, there are cases where stable operation is difficult even with the installation of decompression valves. To verify this, we have measured the decompression performance by the orifice diameter and calculated the reaction force. Results of the study showed that decompression valves need to be produced in different sizes to provide stable decompression where high pressure is required as in high-rise buildings.

The Performance Characteristics of Anti-Surge Devices for High Head Cooling Water Systems in 1,000 MW Thermal Power plants (고수두 1,000 MW 석탄화력발전소 냉각수계통 수격방지장치의 성능특성)

  • Kim, Keun-Pil;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.4
    • /
    • pp.36-42
    • /
    • 2019
  • In recent, according to the tightening of environment regulation policy, the height of the site of the power plant is increased and the length of the cooling water pipe is increased. This has a serious impact on the stability of the plant. This study analyzes the transient phenomenon using LIQT 7.2, an unsteady state one-dimensional analysis software, to secure the stability of 1,000 MW high-capacity coal-fired power plant cooling water system with high head. To prevent water hammer, The effects on performance characteristics were predicted by individual and combination application. The surge pressure of the cooling water which occurs when the pump was stopped without installing the anti-surge devices was the largest at the pump outlet side. The most effective and simple way to reduce surge pressure in these cooling water systems is to combine a vacuum breaker with a hydraulic non-return valve, which is an essential device for pump protection.

Shape Design of the 3-Way Valve used in Marine Diesel Engines (LDCL JWCS) by CFD Analysis (유동해석을 통한 선박용 디젤엔진(LDCL JWCS)의 3-Way Valve 형상 설계)

  • Hwang, Gi Ung;Kwak, Hyo Seo;Kim, Jae Yeol;Eom, Tae Jin;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1077-1084
    • /
    • 2017
  • Camshaft engines designed for constant engine loads have been applied to existing marine diesel engines. However, due to environmental regulations, electro-hydraulic servo mechanisms, which have a loaddependent cylinder liner jacket water cooling system (LDCL-JWCS), have been recently developed to individually control the temperature of the cylinders depending on the engine load. In this system, the 3-way valve, which prevents low temperature corrosion by reducing the temperature difference between the upper and lower parts of the cylinder, has been employed, but the outlet mass flow of the existing valve is low. In this study, the design of the internal shape of the 3-way valve was performed by analyzing the effects of the design parameters of the valve shape on the performance (i.e., the outlet mass flow rate and temperature). The proposed model was verified by comparing its performance to that of existing marine diesel engine valves.

Study on distributing Pressure and Velocity on Exhaust Variable Valve Face of Back Pressure (배기압력이 배기가변밸브 면에 분포하는 압력과 속도에 관한 연구)

  • Kim, Kwon-Se;Choi, Doo-Seuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.1825-1830
    • /
    • 2014
  • Environmental emission of recent automobile is drastically enhanced that it is one of the obvious assignments of exhaust system. This study is a purpose to establish of influence distribution on maxima and minima through the location of pressure on exhaust variable valve. The experiment are checked with real angles using camera which exhaust variable valve is opened side of point. Data has extracted to opening angles with internal flow, pressure. Exhaust variable valve through the floating analysis was analyzed the characteristic of location point about pressure and velocity. The pressures indicated the reduced results internal pressure within muffler. The velocity indicated an opposite results and vibration state of valve was verified to be operated as high speed from lower section. The conclusion to obtain from this study was found out the result to make the optimum back pressure condition as more increasing pressure distribution on valve face if the velocity location attracted by bottom point in order to improve for engine performance.

A Study on the Chattering under Cryogenic Flow Test of a Oxidizer Shutoff Valve (산화제 개폐밸브의 극저온 유동시험에서 채터링의 고찰)

  • Lee, JoongYoup;Han, SangYeop;Lee, SooYong
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.108-117
    • /
    • 2013
  • The oxidizer shutoff valve of a gas generator controls the mass flow rate of the propellant of a rocket engine using pilot pressure and spring the force of the valve. The developing oxidizer shutoff valve can be shut off if the pilot pressure is removed from the actuator. Therefore, force balancing is necessary to analyze the characteristics of the forces with respect to the opening and closing of the valve in order to evaluate its performance. In light of this, the valve has been designed to adjust the control pressure required to open the poppet and to determine the working fluid pressure at which the valve starts to close. Under cryogenic flow test as a tests level of C.R.T(Control Random Test), the chattering phenomena occurred due to much leakage of a metal seat section. The pressure for chattering of the oxidizer valve is predicted at about 11 bar using force balancing analysis.

Lightweight Design of a Main Starting Air Valve through FSI Analysis (구조연성해석을 통한 메인스타팅 에어밸브의 경량화설계)

  • Lee, Kwon-Hee;Jang, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5371-5376
    • /
    • 2013
  • The role of a main starting air valve is to supply compressed air to the diesel engine for starting the stopped diesel engine of a ship and cut off the air during normal operation. In this study, the main starting air valve with 80mm size was designed based on the developed valve with 50mm size. The concept design of the 80A main starting air valve was completed by using CATIA. Then, fluid analysis was performed to investigate the flow characteristics such as pressure and velocity distribution. Sequentially, structural analysis using FSI was performed. In this study, ANSYS CFX and ANSYS Workbench are utilized. The heavy weight of the body can deteriorate the strength performance of neighbor elements, leading to undesirable effect on flow characteristics. Thus, in this research, a lightweight design of the body was suggested satisfying strength requirement. The weight of the suggested design was reduced by 7kg, and the strength satisfied its requirement.

Experimental Study of Operating Parameters for Pneumatic Control Valve in Abnormal Conditions (공기구동 제어밸브 비정상상태 운전변수에 관한 실험적 연구)

  • Kim, Yang-seok;Kim, Dae-woong;Lee, Byoung-oh;Jeoung, Rae-hyuk;Lee, Seung-ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.613-619
    • /
    • 2016
  • A pneumatic control valve performs a major role in controlling the flow of a system or the level of a key tank in many power plants, and its performance should be guaranteed during the plant's lifetime. Its operation starts by supplying air to the pneumatic actuator or by exhausting the air from the actuator. To control the valve position, the amount of air supply or exhaust is adjusted by a control loop where various accessaries are equipped. In this paper, air leakage in the air supply line, changes in the valve packing force, and false adjustments of zero and the span of the positioner are simulated and analyzed using a 2-in pneumatic valve with a position control loop including an I/P converter and positioner, where the valve position is controlled within ${\pm}2%$ of the control pressure at 67% opening position.

Analysis of operating characteristics and design review of oxidizer fill-drain valve (산화제 충전/배출 밸브의 설계 검토 및 작동 특성 분석)

  • Jang, Je-Sun;Kwon, Oh-Sung;Lee, Kyung-Won;Cho, In-Hyun
    • Aerospace Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.79-88
    • /
    • 2011
  • A fill-drain valve is operated by provided control gas at the ground for liquid propellant feeding system of space launch vehicle, which fills or drains on-board propellant tanks with a cryogenic oxidizer. We have analyzed and modified the data of fill-drain valve designed by Yuzhnoye. The simulation model of fill-drain valve is designed by using the AMESim code to predict and evaluate the dynamic characteristics and pneumatic behavior of valve. In this study, we performed a dynamic characteristic simulation on design parameter. And we could predict opening/closing time and pressures, operating performances on design parameters. This study will serve as one of reference guides to enhance the developmental efficiency of fill-drain valves with the various operating requirements, which shall be used in the Koreanized Space Launch Vehicle.