• Title/Summary/Keyword: 밸브설계시스템

Search Result 261, Processing Time 0.033 seconds

Study for the Controller Design of a Direct Drive Servo Valve (직접구동형 서보밸브의 제어기 설계에 관한 연구)

  • 이성래;김종열;김치붕
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.136-136
    • /
    • 2000
  • The direct drive servo valve(DDV) is composed of a DC rotor, link, valve spool and displacement sensor(LVDT) where the spool is directly coupled to the DC motor through the link. Since the DDV is a kind of one-stage valve, the robust controller is required to overcome the flow force effect on the spool motion. The mathematical equations are derived and the stability, accuracy and response speed of a DDV are investigated analytically using a linearized system block diagram. Proportional control, PID control. Time-Delay control, Sliding Mode control, and Proportional control using the load pressure are applied to DDV to find which one shows the best control performance. The digital computer simulation results show that the proportional control using the load pressure satisfies the design requirement of response speed and steady state error regardless of the variation of load pressure,

  • PDF

Optimal Design of Hydraulic System Using the Complex Method (컴플렉스법에 의한 유압시스템의 최적 설계)

  • Lee S.R.;Lee Y.B.;Park J.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.1 no.4
    • /
    • pp.1-8
    • /
    • 2004
  • The optimum design parameters of several hydraulic systems are obtained using the complex method that is one kind of constrained direct search method. First, the parameters of lead-lag controller of the direct drive servovalve is designed using the complex method to satisfy the steady-state error requirement. Second, the optimum locating point of hydraulic cylinder Is determined to minimize the cylinder force in the operation range of rotational sluice gate. For the third application case, the optimum piston area of hydraulic cylinder is determined to minimize the man power to elevate the manually operated sluice gate.

  • PDF

Analysis of Transient Characteristics for Turbopump-fed Liquid Propellant Rocekt Engine in Start-up (터보펌프식 액체 로켓 엔진의 시동 과도 특성 해석)

  • Son, Min;Kim, Duk-Hyun;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.34-37
    • /
    • 2010
  • One dimensional transient analysis was studied for turbopump-fed liquid propellant rocket engine(LRE) system in starting using AMESim. The effects of timing of gas generator fuel valve opening and gas generator ignition to start-up stability were researched for open cycle type system using LOX/RP-1 to propellants. Result show that the parameters and sequence on start-up should be considered to design optimized turbopump-fed LRE system.

  • PDF

Web-Hased Control and Monitoring System Using LonWorks/Ethernet Sever for HVAC Application (LonWorks/Ethernet 서버를 이용한 HVAC의 Web 기반제어에 관한 연구)

  • Hong, Won-Pyo;Ahn, Heong-Soo;Choi, Hoo-Seung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.225-231
    • /
    • 2005
  • 본 연구에서는 프랜트 및 빌딩자동제어 분야에서 적용이 확대되고 있는 LonWorks 필드버스를 이용하여 기존의 공기조화 시스템를 제어하고 있는 DDC제어기를 대체할 수 있도록 필드버스에서 사용이 가능한 고성능 저가의 지능형 제어모듈을 개발하였다. 이는 필드버스 기반의 AHU 전용 지능형제어기를 새로운 설계기술로 개발하고 상품화를 실현하였다. 특히 S/W부분에서도 8 bit Neuron chip에 매우 콤팩트하게 내재된 고성능 응용프로그램도 개발하였다. 또한 Echelon 사의 iLON 100 server의 Soap/XML을 사용하여 Web 브라우저에서 쉽게 프로그램을 작성 제어모니터링 기법을 개발하였다. 공조기의 실험시스템을 구축하여 개발된 전용 제어기 및 Web 기반제어를 실험한 결과 밸브, 댐퍼제어 및 감시기능이 기존 DDC 제어기보다 우수함을 확인하였으며 원격제어 기반을 구축하였다.

  • PDF

Analysis of Dynamics Characteristics of an Underwater Platform System (수중 플랫폼 시스템의 동특성 해석 연구)

  • Byun, Hong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3345-3351
    • /
    • 2012
  • In this study, simulation of an underwater platform system which is able to perform the underwater test is implemented to predict its dynamic characteristics. Accordingly, its governing equations are derived to construct the mathematical model. From the proposed model, the time in flooding and the pressure of ballast tank in blowing air to come up are predicted. In addition, simulation of the stability of the system for repulsive force of the tube by compressed air is carried out. Their results will be used to select valves, air tanks as well as design the system including ballast tanks. And they will help users operate it efficiently.

On the Performance Test of the Piezoelectric-Hydraulic Pump (압전유압펌프 성능실험에 대한 연구)

  • Joo, Yong-Hwi;Hwang, Jai-Hyuk;Yang, Ji-Youn;Bae, Jae-Sung;Lee, Jong-Hoon;Kwon, Jun-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.9
    • /
    • pp.822-829
    • /
    • 2015
  • In this paper, the piezoelectric-hydraulic pump with a piezostack actuator as a driving source has been designed, fabricated, and evaluated for its application to UAV's brake system. The performance requirements of the piezoelectric-hydraulic pump were decided based on the requirements analysis of the target aircraft brake system. The geometric design of the piezoelectric-hydraulic pump to meet the performance requirements of the pump was conducted, and all components of the pump including the spring sheet type check valves were machined with close tolerance. By constructing a test apparatus for the performance check of the piezoelectric-hydraulic pump, the performance characteristics of the pump, such as the outlet flow rate for load-free condition and the outlet oil pressure for closed loop condition, have been evaluated. It has been found by the performance test result that the developed piezoelectric-hydraulic pump satisfies the design requirements effectively.

Study on the controller design of Electronic Water Cleaner (전자식 워터크리너 제어기 설계에 관한 연구)

  • Kim, Gwan-Hyung;Sin, Dong-Suk;Oh, Am-Suk;Choi, Dae-Woo;Kim, Ki-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.143-144
    • /
    • 2014
  • 일반적으로 집이나 건물이 지어진 후 약 2~3년이 지나면 수도관 내부에는 물때, 미생물, 유기화합물질 등이 혼합되어 슬라임(slime)이 발생하며, 노후화되어 슬러지(sludge) 형태로 누적 되거나 스케일(scale)이 발생하고 있다. 이러한 이물질의 누적으로 인하여 수도관이 손상되거나, 여러 가지 원인으로 인하여 교체해야하는 상황이 발생할 수 있다. 이러한 이유로 저수조나 공용관의 경우에는 정기적으로 세척하고 있으며, 일반 가정 내의 수도관 역시 정기적인 관리가 필요하다고 볼 수 있다. 본 논문에서는 적절한 배관청소기의 제어를 위하여 물과 압축공기의 배합을 적절하게 제어하도록 하여 배관내부의 이물질을 제거할 수 있는 배관청소시스템을 설계하고자 하며, 밸브조절 및 물의 공급시간과 압축공기의 유입시간에 대한 적절한 제어를 원격지에서 제어할 수 있도록 배관청소시스템을 개발하여 성능에 관한 평가와 사업화 가능성을 제시하고자 한다.

  • PDF

Calculation and Comparison of Liquid Oxygen Filling System between the KSLV-I Flight Test Data and the Modeling of the KSLV-II Launch Complex (한국형발사체 발사대시스템 산화제공급계 충전 운용 설계의 검증을 위한 나로호 비행시험 실증 자료 분석)

  • Seo, Mansu;Lee, Jae Jun;Hong, Ilgu;Kang, Sunil
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.5
    • /
    • pp.107-114
    • /
    • 2018
  • Korea Space Launch Vehicle (KSLV)-I flight test data and the modified 1-dimensional steady state modeling data from the critical design results of the KSLV-II liquid oxygen filling system operation are compared to validate the reliability of critical design modeling. A comparison of major flow rates and pressure values between test data and calculation results are conducted. The relative errors relative to maximum total flow rate for each cooling, filling, and replenishment mode are determined within 6.7%. Calculated pressure values at the outlet of the pump and the inlet of flow control valves are within 5.1%. The pressure at the inlet of the launch vehicle for each operation mode are within the measured pressure range.

Implementation of micro-magnetic detection system based on wireless sensor networks (무선센서네트워크 기반의 미소자기감지 시스템 개발)

  • Lee, Young-Dong;Park, Jong-Hun;Kang, Hag-Seong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.402-403
    • /
    • 2014
  • Micro-magnetic detection system is used to detect small particles in an automatic transmission valve body, which signal noise and time-delay may occurs in process of signal transmitting and filtering. In this paper, we present the design and implement of a micro-magnetic detection system based on wireless sensor networks. Micro-magnetic detection system consists of five modules which are magnetic sensor detector, signal processing unit, wireless sensor networks, system control unit and system monitoring unit. The experimental results show that signal noise and time-delay decreased.

  • PDF

Numerical Study on the Super Sonic Phenomenon of Compressed Air according to the Flow Path Conditions (유로조건에 따른 압축공기 초음속 유동 현상의 해석 연구)

  • Kim, Seung Mo;Kim, Moosun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.470-476
    • /
    • 2019
  • The braking force for a train is generally provided by compressed air. The pressure valve system that is used to apply appropriate braking forces to trains has a complex flow circuit. It is possible to make a channel shape that can increase the flow efficiency by 3D printing. There are restrictions on the flow shape design when using general machining. Therefore, in this study, the compressed air flow was analyzed in a pressure valve system by comparing flow paths made with conventional manufacturing methods and 3D printing. An analysis was done to examine the curvature magnitude of the flow path, the diameter of the flow path, the magnitude of the inlet and reservoir pressure, and the initial temperature of the compressed air when the flow direction changes. The minimization of pressure loss and the uniformity of the flow characteristics influenced the braking efficiency. The curvilinear flow path made through 3D printing was advantageous for improving the braking efficiency compared to the rectangular shape manufactured by general machining.