• Title/Summary/Keyword: 밸러스트 수 처리 장치

Search Result 10, Processing Time 0.037 seconds

Development of Automatic Backwashing Treatment System for Ballast Water (자동역세척 여과장치를 이용한 선박 밸러스트수 처리)

  • Park Sang-Ho;Lim Jae-Dong;Kim In-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.181-185
    • /
    • 2005
  • The treated ballast water from previous treatment contains microorganisms and pathogenic organisms in an filtration treatment system. The advantage of this process can be filtrated to minimize the demage to screen clogging of drum filter with sweeping the solids off rotating the surface of the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. Also the fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage, too. Filter rotation speed at 20rpmis 40.5cmHg and 40rpm is 36.6cmHg. Filter out impurities from ballast water over 60rpm is 35cmHg. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the removal of ballast water.

  • PDF

A Study on the Removal of harmful life from Ballast by Water Pretreatment (선박 밸러스트수의 유해생물 제거를 위한 전처리 연구)

  • Park Sang-Ho;Lim Jae-Dong;Park Sun-Jung;Kim In-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.221-226
    • /
    • 2006
  • This study is about backwash condition and membrane fouling at continuous filtration process in ballast water treatment. Displayed result that handle particle contaminant and hydrospace organism included a number of ballast that is happened in ship using automatic back washing filter. Reason that removes first contaminant that is included in number of ballast is that heighten processing effect of after processing process of the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The capacity of pilot plant was $10m^3/h$. The result of the test, Backwash cycle time and duration time and a signification effect on the efficiency of system and backwash Backwash duration time was determined to be fixed in 6 seconds of the system with more than 95% removal rate, It needed 1hour backwash frequency. Filtration system removal aquatic organism over $70{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

  • PDF

Sea water Treatment using an Automatic Backwashing Filter (자동역세척 여과장치를 이용한 해수처리)

  • Park Sang-Ho;Lim Jae-Dong;Kim In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.30 no.3 s.109
    • /
    • pp.241-245
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included a number of ballast that is happened in ship using automatic back washing filter. Reason that removes first contaminant that is included in number of ballast is that heighten processing effectof after processing processof the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed of filtration filter could be expose by 35mmHg more than 60 rpm and filter consecutively filtration pressure is 40.5mmHg in 20 rpm and 40 rpm are 36.6mmHg. Filtration system removal aquatic organism over $70{\mu}min$ ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

Ballast water Treatment using a Multistage Filter (다단 디스크 여과장치를 이용한 선박 밸러스트수 처리)

  • Park, Sang-Ho;Lim, Jae-Dong;Kim, In-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.79-83
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included in number of ballast that is happened in ship using automatic bade washing filter. Reason that remove first contaminant that is included in number of ballast is that heighten processing effect of after processing process. of the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed at 1.0rpm is filter resistance 3.0bar and 3.0rpm is filter resistance 2.8bar. Filter out impurities from ballast water over 6.0rpm is filter resistance 26bar and 10rpm is filter resistance 2.5bar. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

  • PDF

Study of Factors for development of Advanced Media filter for Ballast water Treatment (밸러스트 수 처리용 메디아 필터 개발을 위한 여과특성에 관한 연구)

  • Park, Seon-Jeong;Lim, Jae-Dong;Kim, Dong-Geun;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.32 no.6
    • /
    • pp.499-503
    • /
    • 2008
  • As the conference result of MEPC in IMO, development of ballast water management system corresponding to newly established ballast water management standard (D2 regulation) of shipping is being made an active progress over the whole world. The ballast water management system should treat particular material of more than $10{\mu}m$ in high capacity of more than 500t per hour in the event of filtration process. Also, it is very difficult to develop a practical management system since a limited element which a narrow space of the ship should be designed in the minimal volume is assumed. Therefore, the study promoted a study on the next generation auto back wash media filter to overcome such a limited element. Also, the study performed pressure and flux measurement test followed by thickness of each filter medium for filtration by each size to grasp a relation between absorption and pressure at the time of vacuum filtration and mechanical analysis and turbidity change observation of filtered water after vacuum filtration.

Development of sampling device for monitoring micro-organisms in treated ballast water (밸러스트 처리수 미생물 모니터링을 위한 Sampling Device 개발)

  • Park, Sung-Jin;Kim, Ki-Wook;Yoon, Seung-Je;Cho, Dong-Yeon;Kim, Sang-Yong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.312-312
    • /
    • 2011
  • All ship's ballast water should be inspected by administration after enter into force IMO BWM Convention. The purpose of the sampling device is to concentrate large amount of samples and to improve return rate of samples. It is composed of Concentration and Rinsing Part and optimized by the variety of tests. it is fully automated and therefore efficiently operated in ships.

  • PDF

A Study on the Design of Electrolysis Power for the Laboratory Test of BWTS (선박평형수 처리시스템의 랩테스트를 위한 전기분해전원 설계에 관한 연구)

  • Kim, Tae-O;Lee, Sun-Kwon;Joo, Hui-Dong;Kang, Gyu-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1181-1182
    • /
    • 2011
  • 본 논문은 선박에서 발생하는 여러 해양오염원 중에서 선박평형수에서 야기되는 해양생태계의 오염 문제를 해결하기 위하여 사용되는 방법중에서 가장 효율적인 방식인 전기분해 방식에 대한 시스템 설계에 관한 연구로서, IMO의 밸러스트수 관리시스템 승인을 받기 위한 첫 번째 단계인 Basic Approval(랩테스트)을 받기 위한 전기분해 전원장치를 설계하고 시뮬레이션으로 검증하였다.

  • PDF

Effects of Operating Parameters on Ozone Production by Plasma Gun for Ballast Water Treatment (밸러스트 수 처리를 위한 Plasma Gun의 오존생성에 미치는 운전변수의 영향)

  • Lee, Hyeon-Don;Kim, Jong-Oh;Chung, Jae-Woo
    • Journal of Navigation and Port Research
    • /
    • v.34 no.3
    • /
    • pp.205-211
    • /
    • 2010
  • Effects of operating parameters on electrical properties and ozone generation of Plasma Gun for ballast water treatment were investigated in a laboratory scale experiment. Electrical discharges and ozone generation initiated with applying voltages higher than discharge onset value. Ozone concentration was almost linearly increased with the increase of applied voltage. The optimum electrode gap distance which gave the optimum energy efficiency of ozone generation was 1.95 mm in the experimented apparatus. The effect of inner electrode material on the electrical energy transfer was negligible, however, the difference of electrical and thermal conductivities between electrode materials significantly influenced the ozone generation. In a constant geometrical structure, the electrical energy density played an important role in the ozone generation. The increase of oxygen content in the feeding gas enhanced the ozone generation by lowering ionization potential and promoting ozone source.

A Study on the Economic Analysis for Ballast Water Treatment System (선박 평형수 처리 장치의 선내 배치를 위한 경제성 평가 연구)

  • Kim, Soo-Young;Shin, Sung-Chul;Chung, Bo-Young;Jo, Jung-Hwa;Kang, Byung-Yoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.2
    • /
    • pp.258-264
    • /
    • 2010
  • Various kinds of ballast water treatment systems (BWTS) have been developed corresponding to reinforced IMO rules for marine environment. Some of them got the certificate of IMO and others are waiting for it. Selection of optimum BWTS is very important. Optimum BWTS means not only functional requirements but also economic efficiency. This paper presents economic analysis model for optimum BWTS according to ship type and size. In this study 10 kinds of BWTS whose initial installation cost and maintenance cost are known are analyzed based on present worth method. It is assumed that all BWTS satisfy minimum functional requirements and we need to consider different economical efficiency. Through the economic analysis we could select optimum BWTS.