• Title/Summary/Keyword: 배전시스템 평가

Search Result 91, Processing Time 0.021 seconds

A Study on the Reliability of Electric Power Distribution System (배전시스템의 신뢰도에 관한 연구)

  • 김경철;최홍규;원진희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.61-66
    • /
    • 2002
  • Electric power distribution networks are prime examples of systems where a very high degree of reliability is expected. Reliability is the probability of a device or system performing its function adequately for the period of time intended and intented operating conditions intented. This paper shows that a better meshed distribution configuration over the case study of radial configuration distribution system was selected by comparing the indices obtained from EDSA\`s reliability worth assessment of distribution systems program.

Evaluation and Planning of Distribution System Considering Reliability and Harmonics (신뢰도와 고조파를 고려한 배전시스템의 평가 및 계획)

  • Lee Buhm;Kim Yong-ha;Choi Sang-kyu
    • Journal of Energy Engineering
    • /
    • v.14 no.3 s.43
    • /
    • pp.167-172
    • /
    • 2005
  • This paper presents a methodology to support decision making for distribution system planning based on value. To evaluate the reliability value, we employ valued-based distribution reliability assessment. To evaluate the harmonics value, we employ a marginal pricing method, and by using reliability cost, harmonics cost, and construction cost, we can make the most economic decision. By applying the method to the real system, we show this method can get the best result which meet reliability and harmonics level.

Evaluation Algorithm for Coordination Protection Between Recloser and Customer Relay (배전선로보호기기(리클로즈)와 고객계전기의 보호협조 평가알고리즘)

  • Heo, Sang-Won;Kim, So-Hee;Ji, Seong-Ho;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.21-24
    • /
    • 2011
  • 배전계통의 고장 발생 시 광범위한 수용가에 정전파급을 일으킬 수 있으므로 신뢰성이 있는 보호협조의 설계가 매우 중요하다. 따라서 배전계통의 보호협조는 선로고장으로 인한 정전범위를 최소화할 수 있는 시스템으로 설계되어야 한다. 본 논문에서는 국내 22.9kV-y 배전계통에 연계된 보호기기들의 정정치와 보호협조 이상 유무를 확인할 수 있는 보호협조 평가알고리즘을 제시하고, 이 알고리즘을 이용하여 양방향 보호협조 평가시스템을 제작하였다. 그리고 이 평가시스템을 이용하여 배전계통을 모델링하고 보호협조를 검토하여, 제안한 알고리즘이 배전선로의 보호협조 및 안정화에 크게 기여할 수 있음을 확인하였다.

  • PDF

The Development of Probabilistic Power Quality Evaluation Method for Electrical Distribution System (배전시스템 전기설비 구성에 따른 확률론적 전력품질의 정량적 평가기법 개발)

  • Kim, Yong-Ha;Lee, Sung-Jun;Woo, Sung-Min;Lim, Hyun-Sung;Son, Seung-Ki;Ku, Min-Seo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.34-43
    • /
    • 2007
  • This paper presents a methodology on the AHP(Analytic Hierarchy Process) to calculate unified power quality index which provide an overall assessment of the distribution system performance. To obtain the unified power quality index. we propose the use of the AHP model and consider contingency using Monte Carlo simulation. The proposed method is especially useful and effective for planning. We have applied the proposed method to an actual relatively large system.

Evaluation Algorithm for Coordination Protection Between Recloser and Distributed Generation Relay (분산전원수용가와 리클로즈의 보호협조 평가알고리즘)

  • Kim, So-Hee;Heo, Sang-Won;Rho, Dae-Seok;Seo, In-Yong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.69-72
    • /
    • 2011
  • 정부의 녹생성장 정책에 의해서 신재생에너지들의 보급률이 지속적으로 증가되고 있는 실정이다. 특히 배전계통에 태양광/풍력발전 등 분산전원의 설치가 급증함에 따라 기존 배전계통의 조류흐름이 단방향(One direction)에서 양방향(Bi-direction)으로 변화 되어 배전계통의 운용상에 여러 가지 문제점들이 발생할 가능성이 커지고 있다. 따라서 본 논문에서는 분산전원의 배전계통 연계에 따른 보호기기의 정정 및 보호협조검토가 가능한 보호협조 평가알고리즘을 개발하고, 그 알고리즘을 바탕으로 보호협조 평가시스템을 제작하였다. 이 평가시스템에 분산전원 연계 시, 배전계통의 보호기기들 사이의 보호협조를 검토하여 제안한 알고리즘의 유효성을 확인하였다.

  • PDF

Evaluation Algorithm for Coordination Protection Between Substation Relay and Recloser (변전소릴레이와 리클로즈의 보호협조 평가알고리즘)

  • Ji, Seong-Ho;Kim, So-Hee;Heo, Sang-Won;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.17-20
    • /
    • 2011
  • 배전계통의 고장발생 시 광범위한 수용가에 정전파급을 일으킬 수 있으므로 신뢰성이 있는 보호협조의 설계가 매우 중요하다. 따라서 본 논문에서는 국내 22.9kV-y 배전계통에 연계된 보호기기들의 정정치와 보호협조 이상 유무를 확인할 수 있는 보호협조 평가알고리즘을 제시하고, 이 알고리즘을 이용하여 양방향 보호협조 평가시스템을 제작하였다. 본 연구에서 제작한 보호협조 평가시스템을 이용하여 배전용변전소의 보호기기(OCR, OCGR)와 배전선로에 설치되어 있는 보호기기(리클로즈)에 대하여 시뮬레이션을 수행하여, 제안한 알고리즘이 배전선로의 보호협조 및 안정화에 크게 기여할 수 있음을 확인하였다.

  • PDF

Study of Connection Process in Distribution systems using Genetic Algorithm (배전계통에서 GA를 이용한 접속변경 순서 결정 방법)

  • Oh, Seon;Seo, Jeong-Kap
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.1
    • /
    • pp.6-11
    • /
    • 2011
  • In this paper presents a new approach to evaluate reliability indices of electric distribution systems using genetic Algorithm (GA). The use of reliability evaluation is an important aspect of distribution system planning and operation to adjust the reliability level of each area. In this paper, the reliability model is based on the optimal load transferring problem to minimize load generated load point outage in each sub-section. This approach is one of the most difficult procedures and become combination problems. A new approach using GA was developed for this problem. GA is a general purpose optimization technique based on principles inspired from the biological evolution using metaphors of mechanisms such as natural selection, genetic recombination and survival of the fittest. Test results for the model system with 24 nodes 29 branches are reported in the paper.

Quantitative Evaluation of the Customers' Effect by Automatic Reclosing of Power Distribution System (배전시스템에서의 재폐로에 의한 수용가측 영향의 정량적 평가)

  • 임성정;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.7-14
    • /
    • 1998
  • This paper presents an approach to quantitatively evaluate customers' effect due to automatic reclosing of power distribution systems. This proposed approach assess the customers' effect on equip ment halt by predicting a momentary interruption and voltage sag and analyzing the impact of customers' equipment sensitive to electric disturbances. Simulation results show that the increment of the number of reclosing improves the service reliability, but deteriorates the power quality for customers. The proposed approach utilizes the determination of automatic reclosing scheme and distribution system planning.anning.

  • PDF

A Study on the Optimal Voltage Regulation Method of Smart Distribution System (스마트 배전시스템의 최적 전압조정 방안에 관한 연구)

  • Heo, Sang-Wn;Park, O-Seong;Lee, Beom-Tae;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.837-841
    • /
    • 2009
  • 언제, 어디서나 컴퓨터 사용과 통신이 가능한 유비쿼터스 환경의 구축과 개발은 부존자원이 부족한우리나라의 산업 전략에 부합하며 현재 우리나라가 보유한 정보통신 관련기술의 우위를 바탕으로 성장할 가능성이 큰 분야로써 정부가 미래의 10대 성장 동력으로 선정한 분야의 한가지 이다. 배전시스템에서의 이 분야 기술 개발의 핵심내용은 유비쿼터스 기술을 활용한 고 신뢰도의 배전계통 운용 및 높은 수준의 전기품질 관리체제 구축 그리고 이를 통한 관련 산업 즉, 전력거래, 전력시장 유지 및 운영을 위한 핵심 세부 콘텐츠와 부가서비스의 창출을 위한 기반 인프라의 개발 및 구축에 있는데, 이 기반기술의 중심에 배전시스템이 있으므로 이를 고 신뢰, 고품질 기반의 시스템으로 지능화하는 것이 필요하다. 따라서 본 논문에서는 태양광, 풍력 등의 분산전원이 계통에 연계되는 장래의 스마트배전시스템에 대하여, 기존의 배전계통의 전압조정방안과 비교, 분석하여 기술적인 적합여부를 종합적으로 평가하고자 한다.

  • PDF

A study on the development of distribution simulator and simulation results for use in distribution automation system of IEC 61850 protocol (IEC 61850 프로토콜의 배전자동화시스템에 사용을 위한 배전시뮬레이터 개발과 시뮬레이션 결과에 관한 연구)

  • Kim, Jae-Hong;Oh, Jae-Gon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.95-102
    • /
    • 2022
  • It is a study for the evaluation of the stability of the distribution automation system for the expansion of renewable energy. Through the Renewable Energy 3020 Implementation Plan, the government plans to expand new renewable energy and convert it to participatory energy that improves the quality of life of the people by 2030. The government has set a target of 20% of domestic supply energy for renewable energy generation by 2030. It is planning to establish more than 95 percent of its new facilities with clean energy such as solar power and wind power. By expanding the supply of renewable energy, new energy businesses and distributed power industry were fostered, and short-distance, low-voltage, and small-scale power generation were rapidly expanded rather than large-scale power development in the past. Due to this demand, the importance of power distribution facility operation has emerged and the need for distribution automation system is increasing. This paper discusses the development of a power distribution simulator for the performance and function evaluation of power distribution automation systems and presents the results of an interlocking test with the power distribution automation system. In order to introduce an advanced system into the power distribution system, it is necessary to take advantage of the transmission and distribution system. The DNP3.0 protocol is used in the distribution system and the IEC61850 protocol is used in the transmission and distribution system. It was concluded that the functions and performance of operations were satisfied when these two protocols are mixed and used in the distribution automation system.