Heat transfer characteristics of impinging flat plate of multiple slot jets by changing of jet-to-jet distance (배열 슬롯제트의 노즐간격 변화에 따른 충돌면에서의 열전달 특성)

  • Chung, In-Kee;Park, Si-Woo;Hong, Sung-Ho;Ko, Wan-Wook
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.534-539
    • /
    • 2001
  • An experimental investigation of heat transfer characteristics on confined jet impinging plate using multiple slot jets has been performed. The effects of jet Reynolds numbers(Re=2000, 3950, 5900, 7900), dimensionlesss slot-to-plate distances(H/B=2, 4, 6, 8) and jet-to-jet distances(S=16B, 20B, 24B, 30B) on the local and average heat transfer coefficients have been examined. To clarify local heat transfer characteristics, naphthalene sublimation technique were used. From the experimental results, it was found that the local and average heat transfer rates increase with increasing jet Reynolds number. Measurements of local heat transfer coefficients produced by multiple of slot jets have given an indication of the nature of the interaction between jets and of the uniformity of heat transfer obtainable with various arrangements. At S/B=20, Re=7900 and H/B=6, maximum average Nusselt number is obtained.

  • PDF

Heat transfer characteristics of multiple slot jets at the surface of protruding heated blocks (돌출 발열블록 표면에서의 배열 충돌제트에 의한 열전달 특성)

  • Chung, In-Kee;Park, Si-Woo;Hong, Sung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.274-279
    • /
    • 2001
  • An experimental investigation of heat transfer characteristics at the surface of two-dimensional protruding heated blocks using confined impinging multiple slot jets has been performed. The effects of jet-to-jet distances(S=16B, 24B), dimensionless nozzle-to-block distances(H/B=2, 6) and jet Reynolds numbers(Re=2000, 3900, 5800, 7800) on the local and average heat transfer coefficients have been examined with five isothermally heated blocks at streamwise block spacing(p/w=1). To clarify local heat transfer characteristics, naphthalene sublimation technique was used. From the results, it was found that the local and average heat transfer of heated blocks increases with decreasing jet-to-jet distance and increasing jet Reynolds number. Measurements of local heat transfer coefficients have given an indication of the nature of the interaction between jets and of the uniformity of heat transfer obtainable with various arrangements. In the case of S/B=16, H/B=6 and Re=7800, maximum average Nusselt number of overall blocks was obtained.

  • PDF

Effect of nozzle geometry on heat transfer of confined slot jet impingement on a flat plate with square rods (사각봉이 배열된 슬롯제트 충돌면에서 노즐형상이 열전달에 미치는 영향)

  • Chung, In-Kee;Park, Si-Woo;Ko, Wan-Wook
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.272-277
    • /
    • 2000
  • The heat transfer characteristics of confined turbulent slot jet impingement on the flat plate with square rods(turbulence promoter) have been experimentally investigated at different nozzle configuration. The effects of jet Reynolds number (Re=3900, 5800, 7800, 9700), dimensionless slot-to-plate distance(H/B=4, 6, 8) and clearance(c) between square rods and the plate were examined. Measurement of heat transfer rate were conducted using naphthalene sublimation technique. When square rods were inserted over the heat transfer surface, heat transfer rate was slightly increased in the wall jet region and the sharp-edged orifice nozzle was heigher than squared orifice nozzle.

  • PDF

Heat Transfer Characteristics of Confined Slot Jet Impingement on a Flat Plate with Square Rods (사각봉이 배열된 슬롯제트 충돌면에서의 열전달 특성)

  • Chung, In-Kee;Park, Si-Woo
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.119-124
    • /
    • 2000
  • The heat transfer characteristics of confined turbulent slot jet impingement on the flat plate with square rods(turbulence promoter) have been experimentally investigated. The effects of jet Reynolds number (Re=3900, 5800, 7800, 9700), dimensionless slot-to-plate distance(H/B=4, 6, 8) clearance(c) between square rods and the plate, and the length(d) of a side of the square rod were examined. Measurement or heat transfer rate were conducted using naphthalene sublimation technique. When square rods were inserted over the heat transfer surface, heat transfer rate was slightly increased in the wall jet region.

  • PDF

Numerical Analysis on the Heat Transfer Characteristics of Multiple Slot Jets at the Surface of Protruding Heated Blocks (충돌제트의 간격변화에 따른 발열블록 표면에서의 열전달 특성에 관한 수치해석)

  • 박시우;정인기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.229-237
    • /
    • 2003
  • The flow and heat transfer characteristics at the surface of two-dimensional protruding heated blocks using confined impingement multiple slot jets were computationally investigated Numerical predictions were made for round-edged nozzles at several nozzle-to-target plate spacings and jet-to-jet distances, with turbulent jet Reynolds numbers ranging from 2000 to 7800. The commercial finite-volume code FLUENT was used to solve the heat transfer characteristics and flow fields using a RNG $\textsc{k}-\varepsilon$ model. The computed heat transfer characteristics at the surface of heated blocks were in good qualitative agreement with previous experimental data The results of heat transfer characteristics on the surface of protruding heated blocks are important considerations in electronics Packaging design.