• Title/Summary/Keyword: 배열회수

Search Result 133, Processing Time 0.025 seconds

Stress Analysis and Evaluation of Steam Separator of Heat Recovery Steam Generator (HRSG) (배열회수보일러 기수분리기의 응력해석 및 평가)

  • Lee, Boo-Youn
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.23-31
    • /
    • 2018
  • Stress of a steam separator, equipment of the high-pressure (HP) evaporator for a HRSG, was analyzed and evaluated according to ASME Boiler & Pressure Vessel Code Section VIII Division 2. First, from the analysis results of the piping system model of the HP evaporator, reaction forces of the riser tubes connected to the steam separator, i.e., nozzle loads, were derived. Next, a finite element model of the steam separator was constructed and analyzed for the design pressure and the nozzle loads. The results show that the maximum stress occurred at the bore of the riser nozzle. The primary membrane stresses at the shell and nozzle were found to be less than the allowable stress. Next, the steam separator was analyzed for the steady-state operating conditions of operating pressure, operating temperature, and nozzle loads. The maximum stress occurred at the bore of the riser nozzle. The primary plus secondary membrane plus bending stress at the shell and nozzle was found to be less than the allowable stress.

Design and Estimation of Performance of Heat Regenerator for Small-scale Regenerative Radiant Tube Burner (소형 축열식 복사관 버너시스템용 축열기 설계 및 성능평가)

  • 조한창;조길원;이용국
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.05a
    • /
    • pp.171-176
    • /
    • 2004
  • Heat regenerator attached in small-scale regenerative radiant tube burner was designed using the theoretical computation code and was confirmed the performance of waste heat recovery ratio. From the computation, when ceramic ball of 4-5kg was used, temperature efficiency and available waste heat recovery ratio were predicted 80% and 70%, respectively. Similar efficiencies were obtained from the experiments using LPG. However, since exhaust gas temperature entered into regenerator was below 85$0^{\circ}C$ which was much lower than that we expected, preheat air temperature was lowered below 80$0^{\circ}C$.

  • PDF

Performance Analysis of CHP Condersing Season heat load Conditions (계절별 부하 특성을 고려한 CHP 성능 해석)

  • Seo, Young-Ho;Lee, Joon-Hee;Kim, Nam-Jin;Kim, Jong-Yoon;Cho, Sung-Kap;Jeon, Yong-Han
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.454-459
    • /
    • 2010
  • This paper is a actual design case applied to make a bid for CHP plant construction in some country. The purpose of this study is to optimize the system performance for the requirement conditions written in ITB by the client. The system consists of gas turbine, steam turbine, heat recovery steam generator and heat exchangers for district heating. The performance analysis is conducted for various seasons conditions and heat load. As a result, air density and heat load is reduced in accordance with decreasing of the outdoor temperature, therefore the system power is reduced. Considering this, the design parameters to meet the requriement conditions are optimized.

Iterative Polynomial Fitting Technique for the Nonlinear Array Shape Estimation (비선형 선배열 형상 추정을 위한 반복 다항 근사화 기법)

  • 조요한;조치영;서희선
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.8
    • /
    • pp.74-80
    • /
    • 2001
  • Because of ocean waves, swell, steering corrections, etc, the hydrophones of a towed array will not live along a straight line. However the degradation of bearing estimation performance occurs when beamforming is carried out on the hydrophone outputs of an acoustic towed array which is not straight. So it is required to estimate the shape of the array for the improved beamformer output. In this paper, an iterative array shape estimation technique is presented, which is based on the use of the least squares polynomial fitting to the data from heading sensors. The estimation error and the influence of deformations on the performance of the conventional beamformer output are investigated. Finally, the suggested method is applied to the real system in order to investigate the applicability.

  • PDF

Development of 1MW Organic Rankine Cycle System (1 MW급 유기랭킨 사이클 시스템 개발)

  • 박흥수;조한창;이용국
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.318-326
    • /
    • 2001
  • To enhance thermal efficiency of thermal facility through recovery of low and medium temperature waste heat, 1 MW organic Rankine cycle system was designed and developed. The exhaust gases of 175$^{\circ}C$ at two 100 MW power plants in pohang steel works were selected as the representative of low and medium temperature waste heat in industrial process for the heat source of the organic Rankine cycle system. HCFC-123, a kind of harmless refrigerant, was chosen as the working fluid for Rankine cycle. The organic Rankine cycle system with selected exhaust gases and working fluid was designed and constructed. From the operation, it was confirmed that the organic Rankine cycle system is available for low and medium temperature waste heat recovery in industrial process. The optimum operating manuals, such as heat-up of hot water, turbine start-up, and the process of electric power generation, were derived. However, electric power generated was not 1 MW as designed but only 670 kW. It is due to deficiency of pump capacity for supply of HCFC-123. So it is necessary to increase the pump capacity or to decrease the pressure loss in pipe for more improved HCFC-123 supply.

  • PDF

Development of Pulsating Heat Pipe type Waste Heat Recovery Ventilator Using an used Radiator for Vehicles (자동차용(自動車用) 폐(廢) 라디에이터를 이용한 히트 파이프형 환기배열(換氣排熱) 회수기(回收器)에 관한 연구(硏究))

  • Im, Yong-Bin;Choi, Sang-Joe;Kim, Jeong-Hoon;Kim, Jong-Soo
    • Resources Recycling
    • /
    • v.15 no.3 s.71
    • /
    • pp.30-37
    • /
    • 2006
  • For keeping the indoor air quality, we develop the pulsating heat pipe(PHP) type heat recovery ventilator using an used radiator for vehicles. We compare the PHP type with existing model. There are some merits that are able to change the unit number according to heat load and show us the similar performance to existing models.

Comparison of Heat Exchanging Performances Depending on Different Heat Exchanging Pipe Arrangement (열회수장치의 열교환 파이프형식별 열교환 성능 비교)

  • 서원명;윤용철;강종국;김정섭
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.100-102
    • /
    • 2001
  • 본 연구에서는 온실의 난방에 사용되는 열풍식 난방기 등의 배기 연통에 부착하여 배출되는 가스로부터 열을 회수할 수 있는 장치를 개발함에 있어서 연통과 열회수 장치간의 열 교환 성능을 3가지 상이하게 설계된 열 교환 장치(Fig. 1 참조)에 대하여 실험적으로 비교 분석하였다. Fig. 1-(a)는 열 교회수기 개발을 위해 기존에 사용한 장치로서 회수용 공기의 흐름방향이 배기 연통과 직각을 이룬 형식이며, Fig. 1-(b) 및 (c)는 열 회수 성능 개선을 위해 새로 설계된 형식으로서 각각 열 교환 파이프의 배치형식이 상이하나 회수용 공기의 흐름방향이 180도로 굴곡되는 U-자형 흐름이 이루어지도록 하였다. 실험에 사용된 공기 순환 펜의 용량은 AB-형의 경우에는 최대 25㎥/min이고, C-형 및 D-형의 경우는 공히 최대 42㎥/min으로서 송풍전압 조절장치를 이용하여 풍량을 연속적으로 조절할 수 있도록 하였다. U-자형 흐름형식인 C-형 및 D-형의 경우 흐름 방향의 굴곡으로 인한 마찰저항이 있을 것으로 예상은 했으나 당초 예상했던 것에 비해 마찰 저항이 지나치게 큰 것으로 밝혀졌다. 비록 설계된 열교환 튜브의 배열형식별 열 교환기의 외부 모양이 달라 회수기의 표면을 통한 대류 열 교환이 다소 차이를 보일 것으로 예상되지만 본 연구에서는 열 회수장치에 내장된 열 교환 튜브부분만을 통한 열 회수율을 중심으로 형식간의 성능을 비교하였다. 실험을 통하여 측정된 자료중 대표적인 예는 Fig-2와 같으며, 측정자료를 기준으로 분석된 열회수 성능에 대한 설계형식별 비교 결과는 Table-1과 같으며, 분석된 결과를 요약하면 다음과 같다: 1. AB-형 열회수시스템의 경우, 초기 투자비용과 현재의 농용 전력요금 하에서 에너지 절감규모를 비교하면, 대체로 1년을 전후하여 투자에 대한 보상이 충분히 가능할 것으로 판단된다. 2. C-형 및 D-형 열회수시스템의 경우, 열 회수용 공기의 흐름방향이 동일 공간내에서 180도 굴절됨으로서 저항이 크게 발생되어 송풍 펜의 전압 증가에 따른 유속증가가 미미하였으며, 굴절형의 열교환장치는 비록 열교환면적은 직선형과 유사하더라도 송풍 펜의 공기저항이 커져서 결국 열 회수성능이 기대했던 것만큼 크게 개선되지는 못했다. 3. 송풍펜의 용량은 AB-형에 사용된 용량인 25㎥/min 전후가 적절할 것으로 판단되며, 적정 송풍 펜용량 하에서 열 회수성능은 굴절형이 직선형보다 효과적인 것으로 나타났다. 다만, 곡선형은 물론 직선형에서도 열교환 튜브의 배치밀도, 튜브 길이 및 두께 등의 변화에 따른 최적화 연구가 수반되어야 할 것으로 판단된다.

  • PDF

Feasibility study on waste heat utilization system in subway (지하철배열 이용 시스템의 경제성 평가)

  • Lee, Chul-Goo;Kim, Jong-Dae;Im, Tae-Soon;Pang, Seun-Gki;Ham, Heung-Don
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.1
    • /
    • pp.59-64
    • /
    • 2011
  • Feasibility study on energy saving system by utilizing exhausted heat from subway, which is one of the unused energy, was carried out. General heat source system using absorption chiller-heater was used for comparing to the energy saving system, and payback period method using initial cost and running cost of two systems, was used to perform economic estimation. Payback period was about ten years, and this period might be shortened if nation's economic support enact.

환경친화의 코제너레이션 시스템

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.272
    • /
    • pp.81-85
    • /
    • 1999
  • 코제너레이션이란 Co(공동의)와 Generation(발생한다)의 복합어로 이것을 시스템업한 것을 코제너레이션 시스템이라한다. 코제너레이션 시스템은 전기와 열을 동시에 생산하는데서 열(熱)병합 발전시스템이라고도 하며, 종래 대기 가운데 방출되고 있던 엔진배열(排熱)을 회수하여 발전함과 동시에 이것을 활용하여 종합에너지효율을 75$\%$전후로까지 높이는 시스템이다. 배열 이용으로 보일러 운전시간을 단축시켜 연료소비량을 줄일 수 있게 되어 이산화탄소($CO_2$)를 삭감할 수 있는 외에, 연료를 연소시킴으로써 발생하는 질소산화물($NO_x$)에 대해서도 그 저감기술이 여러 가지 개발되고 있어 국가에서 정한 기준치 이하로 억제할 수 있게 되었다. $CO_2$에 대해서는 지구 온난화방지 교토회의에서 1990년 대비 6$\%$삭감에 합의가 이루어졌으며, 이것을 해결할 수 있는 에너지효율화 환경기기로서 코제너레이션 시스템은 이제부터 보급이 가속화될 것으로 생각된다.

  • PDF

Development and Application of an Economic Assessment Program of Cogeneration Systems (열병합시스템 경제성 평가 프로그램의 개발 및 적용에 관한 연구)

  • Park, Chasik;Kim, Yongchan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1547-1554
    • /
    • 1998
  • The object of this study was to develop an economic assessment program for the optimal design of the cogeneration systems composed of combining engine, generator, waste heat recovery exchanger, absorption chiller, and boiler, etc. The energy demand categorized by electric power, heating, cooling and water supply was determined by statistical data of the existing cogeneration systems. An economic assessment was performed by comparing the total cost of cogeneration system with that of non-cogeneration system. The total cost was evaluated by adding initial investment to operational cost considering efficiency of equipment, cost of equipment, fuel and electricity. To confirm the validity of the developed program, a hotel building with an area of $127,960m^2$ was selected, and the simulated results were compared with the measured data. The difference between the simulated and the measured values for the selected hotel building was approximately 12% for annual electric consumption.