• Title/Summary/Keyword: 배열경계

Search Result 178, Processing Time 0.03 seconds

A Study on Effective Output Control Technique for Rotational Transmission Beam Drive of Sonar Transmitter (소나 송신기의 회전 송신빔 구동을 위한 효율적인 출력 제어 기법 연구)

  • Lee, Byung-Hwa
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.5
    • /
    • pp.280-287
    • /
    • 2012
  • This paper presents a study on the experimental analysis of the impedance characteristics according to the rotational direction of the transmission beam of a cylindrical sensor array. Besides, this suggests a real time control technique of the transmitter output for the effective maximum power transmission, in order to drive efficiently the rotational transmission beam of the active sonar transmitter. The output characteristics of the transmitter and the real-time impedance variations of the sensor array are analyzed under the overload conditions. They are caused by electric and acoustic boundary conditions when the rotational transmission beam is operated. From these results, a new output control method of the transmitter is proposed to protect the transmitter and its loads. It can maximize the output power without the transmission pause even if the transient phenomena occur. The proposed technique is verified from the experiment.

A Z-Index based MOLAP Cube Storage Scheme (Z-인덱스 기반 MOLAP 큐브 저장 구조)

  • Kim, Myung;Lim, Yoon-Sun
    • Journal of KIISE:Databases
    • /
    • v.29 no.4
    • /
    • pp.262-273
    • /
    • 2002
  • MOLAP is a technology that accelerates multidimensional data analysis by storing data in a multidimensional array and accessing them using their position information. Depending on a mapping scheme of a multidimensional array onto disk, the sliced of MOLAP operations such as slice and dice varies significantly. [1] proposed a MOLAP cube storage scheme that divides a cube into small chunks with equal side length, compresses sparse chunks, and stores the chunks in row-major order of their chunk indexes. This type of cube storage scheme gives a fair chance to all dimensions of the input data. Here, we developed a variant of their cube storage scheme by placing chunks in a different order. Our scheme accelerates slice and dice operations by aligning chunks to physical disk block boundaries and clustering neighboring chunks. Z-indexing is used for chunk clustering. The efficiency of the proposed scheme is evaluated through experiments. We showed that the proposed scheme is efficient for 3~5 dimensional cubes that are frequently used to analyze business data.

A Numerical Analysis of Flow Characteristics in a Heat Recovery Steam Generator with the Change of Inlet Flow Conditions (배열회수보일러(HRSG)의 입구유동 경계조건에 따른 유동특성 변화에 관한 연구)

  • Kim, Tae-Kwon;Lee, Boo-Yoon;Ha, Ji-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.53-57
    • /
    • 2011
  • The present study has been carried out to analyze the flow characteristics of a heat recovery steam generator with the change of inlet flow conditions by using numerical flow analysis. The inlet of HRSG corresponds the outlet of gas turbine exit and the flow after gas turbine has strong swirl flow and turbulence. The inlet flow condition of HRSG should be included the exit flow characteristics of gas turbine. The present numerical analysis adopted the flow analysis result of gas turbine exit flow as a inlet flow condition of HRSG analysis. The computational flow analysis result of gas turbine exit shows that the maximum axial velocity appears near circular duct wall and the maximum turbulent kinetic energy and dissipation rate exist relatively higher gradient region of axial velocity. The comparison of flow analysis will be executed with change of inlet turbulent flow condition. The first case is using the inlet turbulent properties from the result of computational analysis of gas turbine exit flow, and the second case is using the assumed turbulent intensity with the magnitude proportional to the velocity magnitude and length scale. The computational results of flow characteristics for two cases show great difference especially in the velocity field and turbulent properties. The main conclusion of the present study is that the flow inlet condition of HRSG should be included the turbulent properties for the accurate computational result of flow analysis.

Preliminary Shielding Analysis of the Concrete Cask for Spent Nuclear Fuel Under Dry Storage Conditions (건식저장조건의 사용후핵연료 콘크리트 저장용기 예비 방사선 차폐 평가)

  • Kim, Tae-Man;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.391-402
    • /
    • 2017
  • The Korea Radioactive Waste Agency (KORAD) has developed a concrete cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. During long-term storage of spent nuclear fuel in concrete casks kept in dry conditions, the integrity of the concrete cask and spent nuclear fuel must be maintained. In addition, the radiation dose rate must not exceed the storage facility's design standards. A suitable shielding design for radiation protection must be in place for the dry storage facilities of spent nuclear fuel under normal and accident conditions. Evaluation results show that the appropriate distance to the annual dose rate of 0.25 mSv for ordinary citizens is approximately 230 m. For a $2{\times}10$ arrangement within storage facilities, rollover accidents are assumed to have occurred while transferring one additional storage cask, with the bottom of the cask facing the controlled area boundary. The dose rates of 12.81 and 1.28 mSv were calculated at 100 m and 230 m from the outermost cask in the $2{\times}10$ arrangement. Therefore, a spent nuclear fuel concrete cask and storage facilities maintain radiological safety if the distance to the appropriately assessed controlled area boundary is ensured. In the future, the results of this study will be useful for the design and operation of nuclear power plant on-site storage or intermediate storage facilities based on the spent fuel management strategy.

Vertical Distribution of Vascular Plants in Namdeogyusan, Mt. Deogyu National Park by Temperature Gradient (덕유산국립공원내 남덕유산 관속식물의 고도별 온도구배에 따른 수직분포)

  • Kim, Jung-Hyun;Kim, Sun-Yu;Park, Chan-Ho;Lee, Byoung Yoon;Yun, Jong-Hak
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.5
    • /
    • pp.651-680
    • /
    • 2015
  • In order to investigate vertical plant distribution on Namdeogyu of Mt. Deogyu National Park by temperature change, vascular plants of nine areas with 100-meter-high difference were surveyed from the Deogsangyo (650m alt.) to the Namdeogyusan (1,507m alt.). A total of 455 taxa belonging to 99 families, 280 genera, 402 species, 5 subspecies, 43 varieties, 4 forms and 1hybrid were vegetated on survey areas. Around 700 m high did species diversity of vascular plants decrease rapidly. The Detrended correspondence analysis (DCA) divided distribution of vascular plants into five groups; areas below 700m alt., 700~1,100m alt., 1,100~1,300m alt., and areas above 1,300m alt.. These results showed that vegetation of vascular plants on investigated areas has high correlation with climate elements of temperature. Vascular plants should be crowded within their own optimal ranges of vegetation. Climate change would result in shift of these distribution ranges, and thus vegetation shift will be happened accordingly.

Vertical Distribution of Vascular Plants in Osaek valley, Seoraksan National Park by Temperature Gradient (설악산국립공원 오색계곡 관속식물의 고도별 온도구배에 따른 수직분포)

  • Yun, Jong-Hak;Kim, Jung-Hyun;Kim, Sun-Yu;Park, Chan-Ho;Lee, Byoung-Yoon
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.2
    • /
    • pp.156-185
    • /
    • 2012
  • In order to investigate vertical plant distribution on Osaek valley of Mt. Seorak by temperature change, vascular plants of fourteen areas with 100-meter-high difference were surveyed from the Osaekgyo(345m alt.) to the Daecheongbong(1708m alt.). A total of 449 taxa belonging to 94 families, 279 genera, 397 species, 5 subspecies, 45 varieties, and 2 forma were vegetated on survey areas. Around 500 m high did species diversity of vascular plants decrease rapidly. The Detrended correspondence analysis(DCA) divided distribution of vascular plants into five groups; areas below 500m alt., 500~900m alt., 900~1400m alt., 1,400~1,600m alt., and areas above 1,600m alt.. These results showed that vegetation of vascular plants on investigated areas has high correlation with climate elements of temperature. Vascular plants should be crowded within their own optimal ranges of vegetation. Climate change would result in shift of these distribution ranges, and thus vegetation shift will be happened accordingly.

Vertical Distribution of Vascular Plants in Jungsanri, Mt. Jiri by Temperature Gradient (지리산 중산리계곡 관속식물의 고도별 온도구배에 따른 수직 분포)

  • Yun, Jong-Hak;Kim, Jung-Hyun;Oh, Kyoung-Hee;Lee, Byoung-Yoon
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.6
    • /
    • pp.680-707
    • /
    • 2010
  • In order to investigate vertical plant distribution on Jungsanri of Mt. Jirisan by temperature change, vascular plants of fourteen areas with 100-meter-high difference were surveyed from the Jungsan bridge(348 m alt.) to the Jangteumog(1653 m alt.). A total of 440 taxa belonging to 104 families, 287 genera, 385 species, 7 subspecies, 42 varieties, and 6 forma were vegetated on survey areas. Around 700 m high did species diversity of vascular plants decrease rapidly, but foreign species were not found. The Detrended correspondence analysis(DCA) divided distribution of vascular plants into five groups; areas below 500m alt., 500~600m alt., 600~1000m alt., 1000~1200m alt., and areas above 1200m alt.. These results showed that vegetation of vascular plants on investigated areas has high correlation with climate elements of temperature. Vascular plants should be crowded within their own optimal ranges of vegetation. Climate change would result in shift of these distribution ranges, and thus vegetation shift will be happened accordingly.

One-dimensional head distribution analysis in two-layer porous media using integral equations (적분방정식(積分方程式)을 이용한 2층(二層) 다공성(多孔性) 매질(媒質)에서의 1차원 수두분포(水頭分布) 해석)

  • Lee, Sang Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.97-103
    • /
    • 1993
  • This paper presents a quasi-analytical method using integral equations to obtain head distributions in unsaturated porous media with different hydrogeologic properties. One-dimensional soultion algorithms were developed for two cases of boundary conditions at the top: 1) constant head and 2) constant flux. Water table elevation at the bottom was assumed known for both cases. The methodology was applied to a fly ash disposal facility in an alluvium area. The results showed that the pressure head distributions had high nonlinearity with large gradients slightly above the interface of two media which made preliminary numerical solutions implausible. The developed method helped to structure finite element grids for improving convergence and accuracy.

  • PDF

A Study on the Microstrip Patch Antenna Using FDTD Method (유한 차분 시간법을 이용한 마이크로스트립 패치 안테나에 관한 연구)

  • 장용웅;박상규;신철재
    • Journal of Broadcast Engineering
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 1997
  • In this paper, a microstrip patch antenna was analyzed by using FDTD method. Firstly, the electric field in the microstrip patch antenna was obtained by approximating a Maxwell's equation to a finite difference equation by means of Yee's algorithm. In this case, Mur's 1st approximation and dispersive boundary condition(BBC) were applied to an absorbing boundary condition. We also analyzed a single microstrip patch antenna by using the FDTD method, then calculating the propagative process in the wave of a return loss. Also, as the result that FDTD was applied to 2-array antenna designed to increase the gain of antenna, the measured results was in relatively good accordance with the values calculated by the FDTD method. The calculated impedance, return loss and VSWR were comparatively good. And these results were In relatively good accordance with the measured values.

  • PDF

A Research on the viscous flow and the hydrodynamic force due to the small-amplitude in-phase oscillation of multi-cylinders (복합 원형 실린더군의 저진폭 동위상 진동에 의한 점성유동 및 동유체력에 관한 연구)

  • Sung-Kyun Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.2
    • /
    • pp.22-28
    • /
    • 1999
  • Small amplitude in-phase oscillations of multi-cylinders are considered both numerically and experimentally. Flow field is separated into inner and outer regions. The basic unsteady solution is obtained analytically and the secondary flow, termed as steady streaming flow, can be obtained numerically by using Finite Volume Code with Panel Method. The Particle Induced Velocimetry, one of whole field measurements, is introduced for comparison with numerical flow visualization quantitatively. Among the algorithms for PIV, the Three Step Vector Searching Technique is applied to reduce CPU time. Small but non-zero damping coefficient, that is important in lightly damped system can be obtained with varying number of bodies and distances.

  • PDF