• Title/Summary/Keyword: 배연효율

Search Result 61, Processing Time 0.026 seconds

Absorptive Separation of Sulfur Dioxide using Flat Membrane Contactor (평판형 분리막 접촉기를 이용한 이산화황 흡수 분리)

  • Lee Yong-Taek;Lee Young-Jin;Song In-Ho;Jeon Hyun-Soo;Ahn Hyo-Seong;Lee Hyung-Keun
    • Membrane Journal
    • /
    • v.16 no.3
    • /
    • pp.196-203
    • /
    • 2006
  • A flue gas emission known to cause an acid rain, containing sulfur dioxide, is tightly controlled by a regulation. The membrane contactor could be one of the alternatives which might be useful technologies for better performance of desulfurization. The fundamental sulfur dioxide separation data were obtained by a flat membrane contactor so that they could be utilized for the full scale membrane contactor. The separation of sulfur dioxide was measured in terms of the concentration of NaOH absorbent, the concentration of sulfur dioxide, the feed flow rate and different membrane materials. As the concentration of absorbent increased, the removal efficiency increased. By increasing the concentration of sulfur dioxide, the removal efficiency decreased. As the feed flow rate increased, it was observed that the removal efficiency decreased. Finally, the effect of the membrane material on separation was found to be negligible.

Evaluation and application of grinding index of domestic desulfurization limestone (국내 탈황용 석회석의 분쇄성 지수 평가 및 응용)

  • Seo, Jun Hyung;Baek, Chul Seoung;Cho, Jin Sang;Ahn, Young Jun;Ahn, Ji Whan;Cho, Kye Hong
    • Journal of Energy Engineering
    • /
    • v.28 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • In the flue gas desulfurization process of the coal-fired power plant, the grinding efficiencies of the limestone as the sorbent for desulfurization were compared after BWI and HGI measurements. As a result, the grinding index of the domestic desulfurization limestone were linear inversely proportional relationship with decreasing BWI was observed with increasing HGI. There was a difference in grinding efficiency depending on the chemical composition and crystal structure. Therefore, it is considered that when grinding ability of limestone is measured, the grinding property of the sample can be confirmed even by using HGI which can be measured more easily than BWI which is difficult to measure and takes a long time. The desulfurization efficiency can be improved by selective utilization of limestone depending on the crushing characteristics.

A Study on Removal Efficiency of VOCs using Vortex Cyclones (보텍스 사이클론을 이용한 VOCs 제거효율에 관한 연구)

  • Lim, Gye-Gyu
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.194-199
    • /
    • 2005
  • The principle of vortex cyclone was applied to enhance the treatment efficiency of waste air streams containing particulate matters, phenol, and others. Adsorption, condensation, and/or coagulation could be induced at low temperature zone formed by Joule-Thomson expansion as the pressurized air and pulverized activated carbon were introduced at the tangential direction into the cyclone system applied with the coaxial funnel tube of vortex cyclone. Easily condensible vapors were adsorbed and/or condensed forcibly on coagulated or condensed materials which were formed as cores for coagulation or condensation by themselves or on pulverized activated carbons. These types of coagulation or condensation rates were rapidly promoted by increase in their diameter. The maximum removal efficiency obtained from this experiment for the removal of carbon dioxide and phenol was about 87.3 and 93.8 percent, respectively. Phenol removal efficiency was increased with the relative humidities and enhanced by pulverized activated carbon added. The Joule-Thomson coefficients were increased with the pressure of air injected in the range of the relative humidities between 10% and 50%. It is believed that the moisture, particulate matters, and the pressure of the process air introduced could control the removal efficiency of VOCs.

Prediction of Cleaning Time of Desulfurization Absorber in a Oil-Fired Power Plant through the Operation Data (중유화력발전소의 운전자료를 이용한 탈황 흡수탑의 세정시기 예측)

  • Jang, Yeong-Gi;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.11 no.4
    • /
    • pp.38-46
    • /
    • 2015
  • 중유를 연소하는 D 발전소 탈황설비는 운전시간의 경과에 따라 흡수탑 중간층에 석고가 쌓이고 가스분사 파이프 내에 경질석고 스케일이 부착됨으로써 발전설비 및 탈황설비의 정상적인 운전이 어렵게 된다. 흡수탑 내부에 발생된 스케일을 제거하지 않을 경우에는 탈황효율의 저하에 따른 SO2 배출농도의 증가로 발전가능 최대출력의 하향조정이 발생되고 나아가 발전정지를 초래한다. 스케일 제거를 위한 탈황설비 세정은 발전가능 최대출력의 하향조정이 발생하는 시점으로 결정할 수 있다. 본 연구에서는 탈황설비의 운전 자료를 분석하여 발전가능 최대출력의 하향조정이 발생되기 6주 전은 탈황설비 출구 SO2 농도값이 130ppm을 초과하고 동시에 흡수탑 차압은 380mmH2O을 초과하며, 직전 흡수탑 세정 이후 44주가 경과된 시점이 됨을 확인하였다. 그리고 흡수탑의 세정시기는 세정준비기간 6주와 발전가능 최대출력 하향이 발생되기 6주 전까지의 운전경과일수 44주를 더하여 직전 세정시점으로부터 50주가 경과된 시점임을 예측하였다.

  • PDF

Collection Efficiency of a Mist Eliminator for Wet Flue Gas Desulfurization (습식 배연탈황설비용 습분제거기 포집효율 평가)

  • Kim, Moon-Won;Yook, Se-Jin;Yu, Tae U
    • Particle and aerosol research
    • /
    • v.14 no.3
    • /
    • pp.73-80
    • /
    • 2018
  • Recently, there has been much research on the effect of ultrafine dust on human body with increasing interest in the ultrafine dust. In the Republic of Korea, there are many old thermal power plants, and the amount of ultrafine dust emitted from the thermal power plants is reported to be about 14% of the total amount of domestic fine dust. Therefore, the amount of fine dust from the flue gas desulfurization facility in the thermal power plant needs be reduced. In this study, we made an experimental setup to simulate a flue gas desulfurization facility and analyzed the physical characteristics of the particles passing through a mist eliminator. Experiments were carried out to investigate the collection efficiency of the mist eliminator by using the Arizona Test Dust in a dry environment, and then spraying limestone slurry into the flue gas desulfurization system equipped with the mist eliminator to examine the size and morphology of limestone particles upstream and downstream of the mist eliminator. Cut-off size of the mist eliminator was formed at about $6{\mu}m$. The result of this study is expected to be helpful for designing an electrostatic precipitator for removing particles passing through the mist eliminator.

Study under productivity measurement and verification of the underground temporary material installation work by simulation technique (시뮬레이션을 활용한 지하가설물 설치작업의 생산성 측정 및 검증에 관한 연구)

  • Bae Yeon-Jin;Park Sang-Hyuk;Han Seung-Heon;Paek Joon-Hong
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.427-432
    • /
    • 2004
  • As it is keen competition of a construction market and the recognition that increases construction productivity for maintaining competitiveness, it is increased importance of an interest about productivity and efficiency in the construction industry. This study measures productivity through the instance of investigation that the existing productivity measurement method was utilized and presented a work improvement matter based on the measured contents. The proposed improvement matter is verified through a simulation technique. The purpose of this paper is for a field supervisor to have presented the way that a selection does the most suitable work method to be suitable for a situation, and can forecast production, though a simulation technique is not the most alternative that considered field condition in analyzing productivity measurement.

  • PDF

Development of Absolute Deformation Analysis System by Close-Range Photogrammetry (Close-Range Photogrammetry에 의한 절대변형해석 시스템의 개발)

  • 배연성
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.2
    • /
    • pp.127-135
    • /
    • 2004
  • The calibration of lens to be used and the planning of photographing planning layout is very important to achieve the requested accuracy in the precision measurement by close-range photogrammetry. Establishment of absolute coordinate system is regarded as another important factor for the purpose of measuring absolute deformation of photogrammetric object. In this study, the following tasks were performed : (1) calibration of super-wide-angle lens or focal length 21mm fer close-range photographing used by 35mm metric camera, (2) development of the measuring system for monitoring of absolute deformation through periodic observation of small area, and, (3) application of this system to monitor the absolute deformation of surface of underwater structure in fixed cycle and to present the efficiency of the system.

A Study on the Desulfurization Efficiency as a Variation of Flow Field Applyed a Mixing Enhancement Apparatus (혼합촉진장치 적용시 유동장 변화에 의한 탈황효율 연구)

  • Chung, J.D.;Kim, J.W.;SeomMun, J.
    • Journal of ILASS-Korea
    • /
    • v.15 no.4
    • /
    • pp.177-181
    • /
    • 2010
  • This paper has designed a mixing enhancement apparatus called Lobed-plate and Step-plate and comparatively calculated desulfurization efficiency of when its shape was changed. The parameters used at this time were the shape, SR ratio and the number of nozzles of the mixing enhancement apparatus and comparatively analyzed desulfurization efficiency according to these parameters. As a result, the Step-plate appeared as more highly by around 4% than Lobed-plate in desulfurization efficiency according to the shape of the mixing promotion apparatus, and when the desulfurization efficiency as a SR ratio is considered, it appeared highly by an average of 5% when the SR ratio is 3 rather than 2. As a result of comparing desulfurization efficiency by fixing the SR ratio and setting the number of nozzles as 4 pieces and 6 pieces, there was no big change in desulfurization efficiency when the SR ratio is 2, but it could be confirmed to improve by around 5% when the SR ratio is 3 when time passed 8 seconds.

Property Analysis of Natural Brucite and Its Application as Sulfur Dioxide Absorbent (천연 Brucite의 물성분석 및 이산화황 흡수제로의 응용)

  • Kang, Seong-Gu;Kim, Myoung-Hwan;Kim, Jin-Bae
    • Clean Technology
    • /
    • v.15 no.4
    • /
    • pp.239-244
    • /
    • 2009
  • $Mg(OH)_2$ slurry was prepared by using natural mineral brucite mined in Liaoning province in China, and its de-$SO_x$ efficiency was compared with that of $Mg(OH)_2$ slurry prepared by thermal decomposition and hydration of magnesite. The physical and chemical characteristics of $Mg(OH)_2$ Powders prepared from brucite and magnesite were similar. However, the layered plate structure of $Mg(OH)_2$ crystal particles prepared from brucite had grown more stably. The desulfurization efficiency of $Mg(OH)_2$ slurry prepared from brucite was slightly higher than that of magnesite. Brucite may be used as a new absorbent for the desulfurization of flue gas in the future.

Occurrence of Kiwifruit Vine Decline Syndrome and Its Prevention Using Rootstock Tolerant to Waterlogging (키위 쇠락증상 발생 및 습해 저항성 대목을 이용한 예방)

  • Gyoung Hee Kim;Eu Ddeum Choi
    • Research in Plant Disease
    • /
    • v.29 no.4
    • /
    • pp.425-432
    • /
    • 2023
  • Kiwifruit industry has been threatened by the emergence of kiwifruit vine decline syndrome causing plant death within one or two years from symptom appearance. The main symptoms of this syndrome are root cortex breakdown, leaf necrosis, phylloptosis, fruit skin wrinkling, and twig wilting. Kiwifruit vine decline syndrome occurred on both Actinidia chinensis var. chinensis and A. chinensis var. deliciosa in mid-summer after rainy season. Kiwifruit vine decline syndrome was turned out to be severely occurred in wettable clay soils affected by waterlogging or poor aeration. No pathogens were directly correlated with the syndrome. Kiwifruit vine decline syndrome could be expected to be efficiently prevented controlled using Bounty 71 rootstock tolerant to water stress such as waterlogging.