• Title/Summary/Keyword: 배수펌프장

Search Result 89, Processing Time 0.039 seconds

Design of Edtention Pond and Critical Duration of Design Rainfall in Seoul (유수지 설계를 위한 계획강우의 임계지속기간 -서울 지역을 중심으로-)

  • 이종태;윤세의
    • Water for future
    • /
    • v.26 no.1
    • /
    • pp.115-124
    • /
    • 1993
  • This study is to determine the critical duration of design rainfall and to utilize it for the design of detention pond with pump station. To examine the effect of the duration and temporal distribution of the design rainfall, Huff's quartile method is used for the 9 cases of durations ranging from 20 to 240 minutes with 10 years return period, and the ILLUDAS model is used for runoff analysis. The storage ration which is the ratio of maximum storage amounts to total runoff volume, is introduced to determine the critical duration of design rainfall. The duration which maximizes the storage ratio is adopted as the critical duration. This study is applied to 18 urban drainage watersheds with pump station in Seoul, of which the range of watershed area is $0.24-12.70\textrm{km}^2.$ The result of simulation shows that the duration which maximizes storage ration is 30 and 60 minutes on the whole. It is shown also that the storage ration of 2nd- and 3rd-quartile pattern is larger than that of 1st- and 4th-quartile pattern of temporal distribution. A simplified empirical formula for Seoul area is suggested by using the regression analysis between the maximum storage ration and the peak ratio, and can be utilized for the preliminary design and planning of detention pond with pump station.

  • PDF

An Application of Fuzzy Control Models to Inland Drainage Pumping Stations with Different Characteristics for Protection of Inland Flooding (상이한 제원특성을 가진 빗물펌프장에서의 퍼지제어모형 적용)

  • Shim, Jae Hyun;Lee, Won Hwan;Cho, Won Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.107-118
    • /
    • 1993
  • Continuous increasing of impervious area due to urbanization and rainfall quantity due to environmental changes aggravate flooding risk in low land area. Therefore. Seoul municipal authorities go on securing an ample budget for reinforcement and establishment of inner water and inland drainage pumping facilities. But. there is no investment for developing optimal operation rules for appropriate application of existing facilities. In this study. fuzzy control techniques are developed. and applied to 57 stations of inner water and inland drainage pump for model assessment. In these results. fuzzy models have more efficiency in the inland flooding protection than the existing pump operation rule by water level in the same conditions.

  • PDF

Uncertainty parameter correlation analysis (빗물펌프장 운영시나리오에 따른 침수저감효과 분석)

  • Sim, Kyu Bum;Kim, Eung Seok;Chung, Gunhui;Jo, Deok Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.546-546
    • /
    • 2016
  • 본 연구에서는 모의 강우 및 실제 발생된 강우 자료를 이용하여 우수관망도의 신뢰도와 위험도를 산출하였다. 모의 강우의 경우 과거 강우자료를 바탕으로 Markov Chain을 이용하여 모의강우발생을 하였으며, 과거 강우자료의 경우 IETD분석을 통해 대표 강우사상을 선정하였다. 또한, 우수관망도의 신뢰도와 위험도를 정량적으로 분석하기 위해 이정호(2012)에서 개발한 방법론을 이용하여 분석하였다. 또한, 우수관망의 경우 강우의 특성에 따라 발생되는 월류특성이 달라질수 있어 본 연구에서는 산정된 대표 강우사상을 그룹화 하여 그룹화된 강우 특성에 따른 위험도를 평가하였다. 우수관망의 경우 배수분구에서 발생되는 내수침수를 방어하기 위해 빗물펌프장이 운영되어 지고 있으며 본 연구에서 빗물펌프장의 운영수위 조건을 시나리오 제작하여 빗물펌프장 운영 수위에 따른 침수저감효과를 분석하였다. 운영수위 조건에 따라 가장 큰 침수저감효과를 보이는 시나리오와 현재운영수위의 월류량을 침수면적으로 변환하기 위해 서울안저누리에서 제공하는 침수흔적도를 이용하여 침수면적으로 변환하였다. 가장 큰 침수저감효과를 보이는 시나리오를 적용하여 침수면적을 산정한 결과 기존의 침수면적에 비해 5.20%의 침수면적이 감소하였다. 본 연구의 결과를 바탕으로 다양한 강우조건 및 펌프의 운영조건을 조합롭게 활용한다면 향후 비구조적 침수저감에 도움을 줄 것으로 판단된다.

  • PDF

Minimization of Pump Running Cost in the Large-scale Water Supply System (광역상수도 계통의 Pump 운전비용 최소화)

  • Lee, Gwang-Man;Kang, Shin-Uk;Kim, Soo-Myung
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.9
    • /
    • pp.759-771
    • /
    • 2009
  • The electricity cost of pumping system accounts for a large part of the total operating cost for long distance water supply networks. This study presents a method based on dynamic programming for establishing an joint optimal operation of pumps and storages system on a hourly basis. Analysis is taken of the relative efficiencies of the available pumps, the structure of the electricity tariff, the consumer-demand pattern, and the storage characteristics and operational constraints of the pipe. The possible system objectives and constraints are described. An application of the method to the existing Yangju Water Supply System consisted of two pump station and 5 storage pools under the condition of expanding pumping facility in the part of the Capital Area Water Supply System is presented, showing that considerable electricity cost savings are remarkable. The approach was found to be implementable in real system operation and large-scale water supply system design in respect of minimizing life-cycle total cost.

A Study of the Automatic Operation Performance of a Pump Station using Resilience Considering Residual Flows (잔류유량 기반 복원력 지수를 통한 빗물펌프장 자동운영 성능 검토)

  • Kim, Young Nam;Lee, Eui Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.793-802
    • /
    • 2022
  • Non-structural improvements to urban drainage systems are necessary to overcome the elevated levels of urban flood damage. This study proposed a type of automatic pump/gate operation technology for urban pump stations that takes reservoir inflows and river water levels into account and its performance is compared with the current operation using the concept of residual flow-based resilience. The proposed automatic operation relies on three pump operations and two gate operations. The water depth at the monitoring node was used for the pump operation, and the monitoring node was selected in consideration of the first overflow node and the maximum overflow node. The target area is the Daegu Bisan urban pump station, and the rainfall data consisted of probability rainfall sets with durations of 30 minutes, 60 minutes, 90 minutes and 120 minutes, and frequencies of 30, 50, and 70 years. As a result of the application of the proposed operation, differences in the resilience between the automatic operation and the current operation were at least 5.20E-05 with a maximum of 8.07E-04. The longer the duration is, the greater the difference in the resilience.

A Safety Evaluation of Detention Reservoirs at Seoul by New Pumping Criteria (우수배제 펌프의 조작기준에 따른 서울시 유수지의 안전검토)

  • Lee, Won Hwan;Park, Sang Deog;Shim, Jae Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.141-150
    • /
    • 1992
  • Rapid change of urban area become a serious cause of disaster in existing drainage systems, and the practical alternatives in that situations are needed. The purpose of this study is to evaluate safety, one of drainage systems, detention reservoir and pumping station by new pumping criteria. New drainage pumping criteria, divided into two parts (rising limb and falling limb), which used in reservoir routing, shows more efficient flood prevention effect than existing criteria (based on the reservoir water level). To obtain the optimal range of flood prevention, sensitivity analysis of each inflow v.s. pumping capacity is tested. As a results, using 10 year design rainfall, 60% of detention reservoir and drainage pumping stations in Seoul are safe. In this results, there must be a fundamental and powerful counterplans to prevent inland flooding in Seoul metropolitan area.

  • PDF

A study on analysis of disaster prevention performance for urban sewer system in Seoul (서울시 하수관로 방재성능 분석에 관한 연구)

  • Kim, Hosoung;Sim, Jea Bum;Ahn, Joo Young;Yoo, Mi Na
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.424-424
    • /
    • 2021
  • 서울시 전역의 하수관로는 4개의 처리구역, 16개의 배수구역, 163개의 배수분구, 748개의 소구역으로 분할하여 관리되고 있다. 하지만 지선관로와 간선관로가 상이한 설계빈도로 계획되어 가장 작은 관리단위인 소구역에서도 일정한 방재성능을 기대하기 어려운 실정이다. 따라서 본 연구에서는 소구역을 동일한 토출구를 갖는 유역으로 재정의하여 서울시 전역을 799개의 소구역으로 재분할한 후, 소구역 단위로 하수관로 방재성능을 분석하였다. 서울시 하수관로 방재성능 분석을 위해 도시유출모형은 SWMM, 도시침수모형은 2DIS를 활용하였다. 도시유출모형에서는 113,286개의 관로와 106,097개의 맨홀을 적용하였으며, 수리시설물은 서울시 관내에 위치한 31개의 모든 빗물저류조와 121개의 빗물펌프장 중 가용 가능한 117개의 빗물펌프장을 적용하였다. 하수관로의 외수위 경계조건은 하천기본계획에서 제시한 방류하천의 기점홍수위를 반영하였다. 도시침수모형에서는 5m 단위의 고해상도 지형자료와 토지피복도를 적용하여 2차원 침수모의를 수행하였으며, 799개의 소구역에 대한 방재성능 분석을 수행하여 이를 시스템에 적용하였다. 서울시 하수관로 방재성능 분석 시스템에서는 799개의 소구역을 대상으로 소구역 정보, 하수관로 정보, 수방시설물 정보, 방재성능 정보를 제공하고 있다. 소구역 정보는 해당 소구역에 대한 기본 정보 및 해당 소구역에 위치한 수리시설물에 대한 기본 정보를 제공한다. 하수관로 정보에서는 관로 및 맨홀을 선택하여 상세정보를 확인할 수 있다. 수방시설물 정보에서는 빗물펌프장, 빗물저류조, 강우관측소, 하천수위관측소, 관로수위관측소에 대한 상세정보를 제공한다. 마지막으로 방재성능 정보에서는 시나리오별 침수결과를 제공하며, 포인트 단위 침수취약지역을 표출한다. 서울시 하수관로 방재성능 분석 시스템은 하수도 정책 입안과 하수도 관련 사업 추진 시 데이터 기반의 신속하고 효율적인 의사결정 업무를 지원할 수 있을 것으로 기대된다.

  • PDF

Development of a New Resilience Index Considering the Residual flow of Urban Drainage System (도시 배수 시스템의 잔류 유량을 고려한 새로운 복원력 지수 개발)

  • Kim, Young Nam;Lee, Eui Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.57-57
    • /
    • 2021
  • 최근 급격한 도시화와 기후변화로 인해 도시의 홍수피해가 증가하고 있으며, 복합적인 재난으로 악화되는 경우가 많아졌다. 복합재난으로 인한 피해를 줄이기 위해 재해발생 전·후 대응이 중요하며, 이를 위해 복원력 개념을 도입할 필요가 있다. 도시 배수 시스템의 복원력은 대상유역의 면적과 절대적인 침수량에 따라 좌우된다. 따라서 지역의 도시 배수 시스템의 복원력을 정확하게 평가하기 위해 대상유역의 정보를 반영한 지역 맞춤형 복원력 지수의 개발이 필요하다. 대상유역의 정보를 반영하기 위해 도시 배수 시스템의 배수능력을 복원력 지수에 적용하였다. 도시 배수 시스템의 배수능력을 나타내기 위해 시스템 잔류유량을 분모로, 침수량을 분자로 하여 복원력 지수를 계산하였다. 본 연구에서는 제안된 새로운 복원력 지수를 대구 비산 빗물펌프장에 적용하였다. 강우자료는 재현기간이 100년, 200년 그리고 300년 빈도의 확률강우량을 사용하였으며, 지속시간은 30분, 60분 그리고 90분으로 설정하였다. 침수량과 시스템 잔류 유량은 1분 단위로 EPA SWMM을 통해 값을 구하였다. 시스템 잔류 유량을 기반으로 하는 복원력 지수는 최소 0.995029에서 최대 0.998662로 나타났다. 본 연구에서 제안한 도시 배수 시스템 잔류 유량 기반 복원력 지수는 배수 시스템의 처리 능력을 반영한 지수라고 할 수 있으며 배수 시설의 설치, 교체 및 재건 등 수해 방재 계획 평가에 활용될 수 있다.

  • PDF

Evaluation of flood runoff reduction facilities based on the decrease in CN: case studies from Gimcheon Pyeonghwa district (CN 저감을 기반으로 한 홍수유출저감시설의 평가: 김천 평화분구지역을 중심으로)

  • Zhu, Ju Hua;Lee, Hyungtaek;Yoo, Chulsang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.247-247
    • /
    • 2016
  • 최근 한국은 지구환경 변화에 따른 기후변화 영향으로 집중호우로 인한 도시홍수가 급증하고 있다. 기상변화에 의한 집중호우와 급증된 도시화로 인해 불투수면적이 증가하고, 이는 홍수시 유출량을 증가시켜 기존 하도 또는 내배수 시스템의 적정 소통량을 초과하여 홍수를 발생시킨다. 그리하여 홍수피해를 저감하기 위해 구조적 및 비구조적 홍수방어대책들이 마련되어 시행하고 있다. 하지만 내수배제시설의 경우, 기존의 치수계획이 빗물펌프장 등 일부 구조물에 한정되어 있기에 해당 홍수방어시설에 과도한 부담이 있는 실정이다. 따라서 유역 내에 투수면적을 최대한 확보하여 토양의 수문학적 특성을 유지 보전시켜 첨두유량, 도달시간, 직접유출량을 도시 개발 이전상태와 최대한 유사하도록 하는 홍수유출저감시설을 설치하여 빗물펌프장과 같은 홍수방어시설에 대한 과부하를 덜어준다. 이러한 홍수유출저감시설은 크게 저류시설과 침투시설로 구분된다. 홍수유출저감시설들은 해당 지역의 입지특성, 재해저감효과 및 제약조건에 따라 설치 위치 및 규모가 결정된다. 또한 저감효과는 CN 값의 변화로 정량화하여 시설의 적합성을 판단할 수 있다. 본 연구에서는 SWMM 모형을 이용하여 김천시의 평화배수분구지역을 대상으로 CN 저감을 기반으로 한홍수유출저감시설을 평가하고자 한다.

  • PDF

Suggestion of conjunctive operation approach for flood reduction in urban drainage system (도시침수 저감을 위한 내배수시설 연계운영방안 제시)

  • Lee, Eui Hoon;Lee, Jung Ho;Kim, Eung Seok;Jo, Deok Jun;Kim, Joong Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.5-5
    • /
    • 2016
  • 기후변화에 따른 수환경의 변화로 도시홍수로 인한 인명 및 재산피해가 증가하여 도시홍수에 대한 중요성이 급격히 부각되는 상황이지만 국내에서는 도시 내배수 시스템의 선진화기술 구축 및 그와 관련된 연구는 미흡한 실정일 뿐만 아니라 효과적인 침수 저감도 어려운 실정이다. 도시지역에서의 내수침수를 효과적으로 방어할 수 있는 구조적, 비구조적 홍수방어 대책의 수립이 시급한 실정이다. 현재 기존의 도시침수 저감 대책들은 유하시설의 용량 증설 및 통수능 확보를 초점으로 하는 구조적인 대책에 머물러 있으며, 유하시설 위주의 대책은 하류에서의 더 큰 홍수를 발생시킬 위험이 있다. 기존 내배수시설의 전체적인 확장은 막대한 예산과 시간을 필요로 할 뿐만 아니라 지구온난화로 인한 이상기후 및 국지성 집중호우에 완벽하게 대응하기 곤란하므로 구조적인 대책과 더불어 집중호우에 대비할 수 있도록 각 시설물의 기능 및 경제성을 최대로 하며 방재성능을 향상시킬 수 있는 비구조적인 대책이 동시에 수립되어야 한다. 본 연구에서는 비구조적인 대책 중 하나로 빗물펌프장 및 빗물저류조의 연계운영에 초점을 맞추었다. 모니터링 지점을 선정하여 빗물저류조의 추가저류공간을 확보하는 운영을 실시하고 빗물 펌프장 유수지의 수위를 낮추어 내수침수를 저감시킬 수 있는 방법을 제안하였다. 기존의 운영과 본 연구에서 제안한 연계운영을 비교하고 효과를 분석하였다.

  • PDF