• Title/Summary/Keyword: 배수성

Search Result 1,900, Processing Time 0.03 seconds

A Study on the Performance of Vacuum Preloading with Vertical Drains (수직배수를 병행한 진공압밀공법 적용시의 연약지반 거동 예측 연구)

  • Park, Jung-Bae;Kim, Seung-U;Kim, Yu-Seok
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.79-88
    • /
    • 1996
  • In this study, prediction of soil behavior under vacuum preloading with vertical drain is explored on the basis of numerical models and toe results were compared with field measurements. Reasonable prediction of the time rate of settlements and pore pressure dissipation under vacuum preloading is the maj or concern. The conventional method for vatsuum preloading is based on modeling vacuum preloading as surcharge loading for the consolidation analysis. However, this modeling may violate the real behavior of soils under vacuum loading since the total stress in the analysis varies due to the modeled surcharge loading whereas in'.situ total stress of soils under vacuum loading is constant. In this study a new method is suggested. Instead of modeling vacuum loading as surcharge loading, negative hydraulic head is applied at the surface drain boundary to simulate the vacuum preloading. Comparisons of predictions and field measurements of soil behavior under vatsuum preloading are presented and the usefulness of the new modeling technique is demonstrated.

  • PDF

A Study on the Applicability of Modified Cam-clay Model in Low Plastic Clays (저소성 점토의 수정 Cam-clay 모델 적용성에 관한 연구)

  • Lee, Song;Kim, Tae-Hwoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.247-256
    • /
    • 2003
  • FEM analyses which are based on modified Cam-clay theory have been generally used in such cases as analyses of stability and displacement fur embankment construction on soft clays. However, the Modified Cam Clay Model can generate some problems in anisotropic stress conditions of field because the critical state theory has been developed through many laboratory tests in isotropic conditions. Thus, the applicability on the prediction of undrained shear strength and pore water pressure which was based on the critical state theory was evaluated by triaxial tests and numerical analyses in isotropic and anisotropic conditions. Used samples often come out in domestic area, together with general low plastic clays which are showing dilatant behavior in shearing process. They were evaluated by laboratory tests and FEM based on MCCM. From the results of test and numerical analysis, the predictions of undrained strength in low plastic clays well coincided with each other in both isotropic and anisotropic conditions. However, the generation of porewater pressure was often overestimated during undrained shearing in anisotropic conditions. The results can generate the errors in the prediction of stress path of field sites during loading such as construction of embankment on soft clays because the field is subjected to anisotropic conditions during loading.

A Study on Urban Inundation Prediction Using Urban Runoff Model and Flood Inundation Model (도시유출모형과 홍수범람모형을 연계한 내수침수 적용성 평가)

  • Tak, Yong Hun;Kim, Jae Dong;Kim, Young Do;Kang, Boosik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.395-406
    • /
    • 2016
  • Population and development are concentrated by urbanization. Consequently, the usage of underground area and the riverside area have been increased. By increasing impermeable layer, the urban basin drainage is depending on level of sewer. Flood damage is occurred by shortage of sewer capacity and poor interior drainage at river stage. Many of researches about flood stress the unavailability of connection at the river stage with the internal inundation organically. In this study, flood calculated considering rainfall and combined inland-river. Also, using urban runoff model analyze the overflow of sewer. By using results of SWMM model, using flood inundation analysis model analyzed internal drainage efficiency of drainage system. Applying SWMM model, which results to flood inundation analysis model, analyzes internal drainage efficiency of drainage system under localized heavy rain in a basin of the city. The results of SWMM model show the smoothness of internal drainage can be impossible to achieve because of the influence of the river level and sewer overflow appearing. The main manholes were selected as the manhole of a lot of overflow volume. Overflow reduction scenarios were selected for expansion of sewer conduit and instruction retention pond. Overflow volume reduces to 45% and 33~64% by retention pond instruction and sewer conduit expansion. In addition, the results of simulating of flood inundation analysis model show the flood occurrence by road runoff moving along the road slope. Flooded area reduces to 19.6%, 60.5% in sewer conduit expansion scenarios.

Cause and Countermeasure of Inundation Damage in Underground Space (우리나라 지하공간 내수침수피해 원인 및 대책)

  • Cho, Jae-Woong;Choi, Woo-Jung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.420-420
    • /
    • 2011
  • 도시지역의 내수침수피해는 거의 매년 발생하고 있으며, 반지하와 같은 거주공간이 매우 취약한 상태이다. 특히 최근에는 지하철, 지하상가 등이 대규모 개발되고 복합네트워크화 되어 지하공간의 침수대책과 대피방안 마련이 시급한 상황이다. 일본의 경우 2000년 토카이 호우피해 후 통합유출해석 모형을 개발하였으며, 1999년 및 2003년 후쿠오카 침수피해 발생 후 특정도시하천침수피해대책법을 제정, 1999 후쿠오카, 2004년 하마마츠, 2008년 카누마 피해 후 일본 방재연구소에서는 실시간 1차원 지표범람모형과 모니터링을 통한 실시간 내수침수지도를 개발하였다. 특히 지하공간에 대해서는 "지하공간에 유입하는 범람수가 계단상 보행자게에 주는 위험성에 관한 연구" 등 실험을 바탕으로 각종 지하공간 침수대책 매뉴얼 및 지하시설의 침수시 피난확보계획 지침, 지하공간 침수대책 가이드라인 등 인명피해를 줄이고자하는 노력이 계속되어 오고 있다. 우리나라는 2006년 경기도 고양시 3호선 정발산역이 침수되었으며, 2010년 서울시 지하철 2호선 사당역 및 4호선이 침수되는 등의 지하철 침수피해와 2010년 서울시 광화문 지하상가, 인천시 부평구 우림라이온스 벨리, 우남플라자, 계양구 농협하나로마트, 서원아파트 등의 지하상가와 지하다층의 침수피해가 발생하였다. 특히 2006년 3호선 정발산역 침수는 17시간이나 지하철이 불통되었고 이로 인하여 심각한 교통 체증이 유발 되었다. 본 연구에서는 2010년 집중호우로 인한 서울, 인천지역의 지하공간 침수피해를 중심으로 최근 10년간 지하공간 침수피해사례로부터 대표적인 침수피해 원인 및 특성을 정리하였으며, 그 결과 지하공간 침수의 주요원인은 지상공간의 침수류가 지하공간으로 유입하고, 지하공간의 배수설비 용량부족, 지하공간으로의 유입을 방지하기위한 방지턱, 차수판, 침수시 비상전원 공급, 침수시 지하공간 대피 매뉴얼의 부재 등 다양한 원인이 있는 것으로 나타났다. 특히, 소방방재청에서 고시한 '지하공간 침수방지를 위한 수방기준'에 지하공간 침수 방지를 위한 각종 시설의 설치 및 대피 경로지정 등에 대한 기준이 마련되어 있으나, 지하공간 중 유동인구가 가장 많은 지하철역에서 조차 침수에 대한 행동매뉴얼이나 대피에 대한 가이드라인이 마련되지 않은 것으로 나타났다. 따라서, 지하공간 침수를 방지하기 위하여 센서를 이용한 자동 차수판과 경보기 설치, 지하공간의 사람들이 안전한 대피로를 찾을 수 있도록 지상공간 및 지하공간 출입구를 모니터링 할 수 있는 CCTV의 설치, Dry Area를 두어 비상대피 할 수 있는 공간의 마련 등 시설적인 부분에 대하여 '지하공간 침수방지를 위한 수방기준'을 더욱 강화할 필요가 있으며, 지상공간의 침수 상황을 고려한 지하공간의 대피매뉴얼 또는 가이드라인 등의 수립이 필요하다. 또한 이와 더불어 재산 및 인명피해를 더욱 효율적으로 줄일 수 있도록 실시간 예 경보를 위한 침수해석 모형의 개발이 시급하다.

  • PDF

Characterization of a Small Cryptic Plasmid from Pseudomonas nitroreducens Strain TX1 (Pseudomonas nitroreducens TX1에 존재하는 작은 플라스미드의 특성 규명)

  • Nguyen, Ngoc Tuan;Lee, Kyoung;Kang, Ju Beom;Huang, Shir-Ly
    • Korean Journal of Microbiology
    • /
    • v.50 no.3
    • /
    • pp.210-215
    • /
    • 2014
  • Pseudomonas nitroreducens TX1 was isolated from a rice field drainage in Taiwan. The bacterium is of special interest because of its capability to use a group of nonionic surfactants such as alkylphenol polyethoxylates even at high concentrations as a sole carbon source. In this study, a small cryptic circular plasmid, pTX1, was characterized from P. nitroreducens TX1. It is 2,286 bp in length with a GC content of 63.3% and harbors three open reading frames, $Rep_{pTX1}$ and functionally unidentified ORF1 and ORF2. The predicted $rep_{pTX1}$ gene product is homologous to Rep proteins of plasmids belonging to the pC194/pUB110 family, which is predominantly found in Gram-positive bacteria and is known to replicate by the rolling-circle mechanism. The copy number of pTX1 was estimated to be about 150 in each cell. Based on the genetic fingerprints and comparison with other plasmids, it is concluded that pTX1 replicates by a rolling circle mechanism which is rarely found for Pseudomonas plasmids.

Performance Evaluation of Concrete using Performance Improving-type Polycarboxylic acid-based Admixture (성능개선형 폴리카르본산계 혼화제를 사용한 콘크리트의 성능평가에 관한 실험적 연구)

  • Seo, Tae-Seok;Choi, Hoon-Jae;Gong, Min-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.5
    • /
    • pp.445-451
    • /
    • 2017
  • Because of the supply-demand problem of aggregate, recently, the construction sites using 100% crushed sand are increasing and the use of low quality aggregate such as farmland sand is increasing too. When the low quality aggregate is used, the various quality defect of concrete such as the strength reduction, the increase of shrinkage and bleeding can be occurred. Therefore, in this study, the performance improvement PC admixture was developed to minimize the quality defect of plain concrete of basement parking area, when the low quality aggregate was used at the plain concrete of basement parking area. The slump loss to elapsed time test, the compressive strength test, the bleeding test and the drying shrinkage test were carried out.

Evaluation of Adhesive Performance of Surface Finishing Material with Primer Based on Silane (실란계 프라이머를 활용한 바닥 마감재 부착성능 평가)

  • Jeong, Gwon-Young;Youn, Da Ae;Jang, Seok-Joon;Kil, Bae-Su;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.39-46
    • /
    • 2017
  • The experimental research was conducted to evaluate the adhesive performance of surface finishing material with primer based on silane(primer). For this purpose, concrete specimens with compressive strength of 18, 30, 50 MPa were made and cured in water condition ($20{\pm}2^{\circ}C$) for 28 days. A primer was applied on the age of 28 days and evaluated according to based on the curing age of the surface finishing material. Moreover, the mortar specimen also made and tested as per KS F 4937 for compared with concrete-based test results. Test results indicated that the adhesive strength of specimens with primer exhibit similar than that of specimens without primer. Also, the adhesive performance improved with increasing in curing age and compressive strength. The correlation between compressive and adhesive strength of mortar and concrete specimens showed similar trend. It was noted that there is no significant effects of primer on adhesive performance of surface finishing material, thus use of primer has superior potential for solving durability problem of concrete slab surface.

Meiobenthic Animals of the Tidal Flat Near the Yeonggwang Nuclear Power Plant (영광원전 주변 해역의 조간대 갯벌에 서식하는 중형저서생물)

  • Kim, Dong-Sung;Choi, Jin-Woo;Kang, Rae-Seon
    • Ocean and Polar Research
    • /
    • v.23 no.2
    • /
    • pp.109-119
    • /
    • 2001
  • Meiobenthic community structure of tidal flats near the Yeonggwang Nuclear Power Plant have studied during summer (June) and fall (October) 1997. Examination of sediment samples collected along the transects showed that there were 18 different types of meiobenthos in the study area. The most abundant meiobenthic animals belonged to Phylum Nematoda in both seasons and all transects. However, sediment samples collected near discharge areas, transects A and B, showed relatively lower abundance than other general coastal areas. Another abundant meiobenthic organism is benthic Harpacticoids which is very sensitive to any environmental changes. Polycheats and Ostracods were next abundant meiobenthos which also showed the difference between the study area and other general coastal areas. Only transect C maintained similar meiobenthic abundance and diversity to other coastal areas. Horizontal distribution for transects A and B showed higher densities in upper and mid tidal flat zones. On the other hand, transect C which is located furtherest from the discharges showed an increasing trend in abundance from upper to lower areas. For size distribution analyses showed that animals which fit into the meshsize of 0.125 mm were abundant, Vertical distribution of meiobenthic animals within the sediments for both sampling seasons showed the highest individual numbers in the surface sediment layers of 0-1 cm depth and showed a decreasing trend as sediment gets deeper. Each class of meiobenthos had different vertical profiles. When comparing survey transects A and B with other similar tidal flat areas, this sites seems to a very unstable environment of tidal flats near the Yeonggwang Nuclear Power Plant.

  • PDF

Accuracy Improvement of Urban Runoff Model Linked with Optimal Simulation (최적모의기법과 연계한 도시유출모형의 정확도 개선)

  • Ha, Chang-Young;Kim, Byunghyun;Son, Ah-Long;Han, Kun-Yeun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.215-226
    • /
    • 2018
  • The purpose of this study is to improve the accuracy of the urban runoff and drainage network analysis by using the observed water level in the drainage network. To do this, sensitivity analysis for major parameters of SWMM (Storm Water Management Model) was performed and parameters were calibrated. The sensitivity of the parameters was the order of the roughness of the conduit, the roughness of the impervious area, the width of the watershed, and the roughness of the pervious area. Six types of scenarios were set up according to the number and types of parameter considering four parameters with high sensitivity. These scenarios were applied to the Seocho-3/4/5, Yeoksam, and Nonhyun drainage basins, where the serious flood damage occurred due to the heavy rain on 21 July, 2013. Parameter optimization analysis based on PEST (Parameter ESTimation) model for each scenario was performed by comparing observed water level in the conduits. By analyzing the accuracy of each scenario, more improved simulation results could be obtained, that is, the maximum RMSE (Root Mean Square Error) could be reduced by 2.41cm and the maximum peak error by 13.7%. The results of this study will be helpful to analyze volume of the manhole surcharge and forecast the inundation area more accurately.

The Need for an Additional Pelvic CT in Cases of Acute Osseous Pelvic Injury that Has Already Been Diagnosed by Abdominal CT. (복부 전산화단층촬영 결과 진단된 급성 외상성 골반골 골절에서 추가적인 3차원 재구성 골반 전산화단층촬영이 필요한가?)

  • Kim, Byoung kwon;Shin, Dong Hyuk;Han, Sang Kuk;Choi, Pil Cho;Lee, Young Han;Park, Ha Young;Bae, Soo Ho;Song, Hyoung Gon
    • Journal of Trauma and Injury
    • /
    • v.22 no.2
    • /
    • pp.206-211
    • /
    • 2009
  • Purpose: Abdominal CT (computed tomography) is a principal diagnostic imaging modality for torso trauma at the Emergency Department (ED). When acute osseous pelvic injuries are detected by abdominal CT, additional three-dimensional (3D) reconstruction pelvic CT is often performed. We compared abdominal CT with pelvic CT to provide information about acute osseous pelvic injuries. Methods: A retrospective investigation of patients'electronic medical records during the five year period between January 1, 2004 and December 31, 2008 among Korean soldiers who underwent pelvic CT after abdominal CT at the ED was conducted. Axial images of abdominal CT were compared with axial images and 3D reconstruction images of pelvic CT. Results: Sixteen patients underwent subsequent pelvic CT after abdominal CT. Axial images of abdominal CT showed the same results in terms of fracture detection and classification when compared to axial images and 3D reconstruction images of pelvic CT. Pelvic CT (including 3D reconstruction images) followed by abdominal CT neither detected additional fracture nor changed the fracture type. Conclusion: This study has failed to show any superiority of pelvic CT (including 3D reconstruction images) over abdominal CT in detecting acute osseous pelvic injury. When 3D information is deemed be mandatory, 3D reconstructions of abdominal CT can be requested rather than obtaining an additional pelvic CT for 3D reconstruction.