• 제목/요약/키워드: 배선용 차단기

검색결과 87건 처리시간 0.035초

유한요소법을 이용한 배선용 차단기의 아크소호 성능향상에 관한 연구 (A Study on Improving Arc Quenching Performance of MCCB by FEM)

  • 김길수;임기조;강성화;조현길;이강원;박정남
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.51-54
    • /
    • 2001
  • This Paper is described basic principles of arc quenching in Molded Case Circuit Breaker. We analyzed magnetic blowout forces acting on the arc in contact system when circuit breakers interrupt fault currents in different three models by 3-D FEM(Finite Element Method). The interrupting time simulated is compared with that of short circuit tests. The results of this study derive valid of the simulation method and present the techniques to improve arc quenching performance.

  • PDF

3D FEM 해석을 이용한 배선용 차단기의 순시트립부 설계 (Design of MCCB Instant Trip Spring by 3D FEM Analysing)

  • 강종성;송희찬;최종웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.134-136
    • /
    • 1998
  • When a MCCB Instant trip spring which is adjusted to notrip at -20% of each current from $5{\times}In$ to $10{\times}In$ and trip +20% of those is designed, we should know attraction force between Fixed Magnet and Armature. So we first made some samples, do experiments of weight, and simulated the modelling by 3D Maxwell S/W. With values of experiment and simulated values, we do design instant trip springs and repeat the above process. Finally we set up the Process of designing Instant spring. With it, we can save time and R&D cost.

  • PDF

배선용 차단기 순시 가조정 트립부 개발에 관한 연구 (Researchs for the Development of MCCB adjustable Instant Trip Unit)

  • 송중천;유만종;김길수;강종성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.354-356
    • /
    • 1999
  • Through the Standard of MCCB, the Adjustable Type Instant Trip Unit should NO trip at -20% of each current from $5{\times}In$ to $10{\times}In$ and trip +20% of those. In this paper, we obtain the attraction force between Fixing Magnet and Moving Armature. So we first made some samples. do experiments of weight, and simulated the modelling by 3D Maxwell S/W. With values of experiment and simulated values, we do design instant trip springs by using the ADAMS S/W of kinematic simulation. Finally we product the 250A Adjustable Instant Trip Unit, and it is very useful to our customers.

  • PDF

HEMP 보호용 전원선 필터 구현 (Implementation of Dedicated Power Line Filter for HEMP Protection)

  • 김근남;이성화;김진태
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.47-52
    • /
    • 2016
  • 본 연구에서는 고고도 핵폭발에 기인한 HEMP의 영향으로부터 민간시설의 적합한 보호를 위한 HEMP 보호용 전원선 필터 구현 필요성을 다루기 위해, HEMP 관련 국방 규격 분석 및 바리스터, 관통형 커패시터, 가스방전관, 인덕터 등의 주요 소자들에 대한 분석을 수행하고, 이를 기반으로 단상 220VAC/16A 용량의 HEMP용 전원선 필터를 간이 제작하였다. 또한 배선용 차단기, 서지 보호기, EMI 필터 등과의 MIL-STD-188-125 PCI 규격 기반의 비교 실험을 수행하였다. 결과적으로 HEMP에 의한 전도성 노이즈로부터 시스템을 보호하기 위해서는 HEMP 보호 전용 필터의 개발이 필수조건임을 확인하였다.

DC 차단기의 하이브리드 아크 소호 기법에 관한 연구 (A Study on the Hybrid Arc Extinguishing Mechanism of the DC Circuit Breaker)

  • 주남규;김남호
    • 한국항행학회논문지
    • /
    • 제19권3호
    • /
    • pp.250-256
    • /
    • 2015
  • 손쉬운 제어성, 운용성 등 다양한 이유로 디지털 부하가 급증하고 있고 이와 함께 부하의 소비 패턴은 직류화 되고 있다. 그러나 공급되는 전력은 교류 전원이므로 실질적으로 필요로 하는 부하의 공급 전원인 직류 전원을 만족하기 위하여 교류 전원을 다시 직류로 변환하여 사용하고 있다. 태양광, 풍력, 연료전지 등 신재생 에너지원의 경우 직류 발전을 하는 발전원으로 교류로 변환을 통해 계통에 유입되고 다시 직류로 변환되어 부하에 공급하게 되는 다단 변환을 하게 되어 손실은 지속적으로 증가하게 된다. 에너지원의 효율적인 사용을 위한 직류 기반의 배전 시스템이 필요로 하나, 부하뿐만 아니라 보호 기능을 구현하기 위한 직류 배선용 차단기의 개발이 필요하다. 이에 본 연구에서는 영구 자석을 이용한 아크 소호 기술과 하이브리드 아크 소호 기술을 이용한 직류 아크 소호 기술에 대한 연구를 통하여 안정적인 직류 배전 시스템 운용을 위한 계통 및 기기 보호가 가능할 것으로 기대된다.

460[V]/400[A]/85[kA] 배선용 차단기의 아크런너 변형을 통한 차단성능 향상 (Improvement of Short Circuit Performance in 460[V]/400{A]/85(kA] Molded Case Circuit Breakers)

  • 이승수;허준;윤재훈;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.394-394
    • /
    • 2009
  • Owing to the increasing number of intelligent homes(or called Smart home), the corresponding cost is much higher. Low voltage circuit breakers are widely used in the intelligent homes to interrupt fault current rapidly and to assure the reliability of the power supply. The distribution of magnetic field induced by arc current in the contact system of molded case circuit breaker(hereafter MCCB) depends on the shape, arrangement, and kinds of material of arc runner. This paper is focused on understanding the interrupting capability, more specifically of the arc runner, based on the shape of the contact system in the current MCCB. The magnetic driving force was calculated by using the flux densities induced by the arc current, which are obtained by three-dimensional finite element method. There is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by current and the flux density be present. This is paper present our computational analysis on contact system in MCCB.

  • PDF

3차원 유한요소 해석을 이용한 배선용 차단기의 전자반발력 계산 (Calculation of Electrodynamic Repulsion Force in Molded Case Circuit Breakers Using the 3-D Finite Element Analysis)

  • 김용기;박홍태;송중천;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.137-140
    • /
    • 2003
  • To the optimization design of molded case circuit breakers(MCCBs), it is necessary and important to calculate the electro-dynamic repulsion force acting on the movable conductor. With 3-D finite element nonlinear analysis, according to the equations among current-magnetic field-repulsion force and taking into account the ferromagnet, contact bridge model is introduced to simulate the current constriction between contacts, so Lorentz and Holm force acting on the movable conductor and contact, respectively, can be integrated to calculate. Coupled with circuit equations, the opening time of movable contact also can be obtained using iteration with the restriction of contact force. Simulation and experiment for repulsion forte and opening time of five different configuration models have been investigated. The results indicate that the proposed method is effective and capable of evaluating new design of contact systems in MCCBs.

  • PDF

460[V]/400[A]/85[kA] 배선용 차단기의 그리드 및 아크런너 변형을 통한 차단성능 향상 (Improvement of Short Circuit Performance in 460[V]/400[A]/85[kA] Molded Case Circuit Breakers)

  • 이승수;정의환;윤재훈;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1451_1452
    • /
    • 2009
  • Owing to the increasing number of intelligent homes(or called Smart home), the corresponding cost is much higher. Low voltage circuit breakers are widely used in the intelligent homes to interrupt fault current rapidly and to assure the reliability of the power supply. The distribution of magnetic field induced by arc current in the contact system of molded case circuit breaker depends on the shape, arrangement, and kinds of material of grids. This paper is focused on understanding the interrupting capability, more specifically of the grid and the arc runner, based on the shape of the contact system in the current MCCB. The magnetic driving force was calculated by using the flux densities induced by the arc current, which are obtained by three-dimensional finite element method. There is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by current and the flux density be present. This is paper present our computational analysis on contact system in MCCB.

  • PDF

460V / 50KA / 100AF 급 배선용 차단기의 소호부 차단 성능 향상 방법 (Methods for Increasing the Interrupting Performance of Are Chamber in 460V / 50KA / 100AF Molded Case Circuit Breaker)

  • 조성훈;정의환;이한주;임기조;김길수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.105-105
    • /
    • 2010
  • Voltage circuit breakers are widely used in power distribution systems to interrupt fault current rapidly and to assure the reliability of the power supply. Power distribution system requires the transformer with higher capacity than ever, but this ever, but this may be the cause. of the increasing of short circuit current in contrast to conventional one when short-circuit accident is occurred. Therefore molded case circuit breaker improved in aspects of interrupting capacity of short circuit current in this system is needed. By using the proposed methods in this paper, such as new arc quenching structure of grid would contribute to minimizing the MCCB, realization of high interrupting performance and reducing the design time and development cost.

  • PDF

저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 고속형 전기안전 보호장치 (Electric Safety Protection Device of High Speed for Incapable Operation of ELB and MCCB Using the Low Voltage Distribution Line)

  • 곽동걸;정도영
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1925-1929
    • /
    • 2007
  • This paper is studied on a novel Electric Safety Protection Device (ESPD) of high speed for incapable operation of Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB) using the low voltage distribution line. The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is ELB and MCCB, of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a novel ESPD of high speed to trip of distribution line on electric arc or spark due to electrical fire. Some experimental results of the proposed ESPD are confirmed to the validity of the analytical results.