• 제목/요약/키워드: 배기면적

Search Result 69, Processing Time 0.035 seconds

Numerical Study on the Effect of Area Changes in Air Inlets and Vent Ports on the Ventilation of Leaking Hydrogen (급·배기구 면적 변화가 누출 수소 환기에 미치는 영향에 관한 수치해석적 연구)

  • Lee, Chang-Yong;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.385-393
    • /
    • 2022
  • Hydrogen has reduced greenhouse gas (GHG) emissions, the main cause of global warming, and is emerging as an eco-friendly energy source for ships. Hydrogen is a substance with a lower flammability limit (LFL) of 4 to 75% and a high risk of explosion. To be used for ships, it must be sufficiently safe against leaks. In this study, we analyzed the effect of changes in the area of the air inlet / vent port on the ventilation performance when hydrogen leaks occur in the hydrogen tank storage room. The area of the air inlet / vent port is 1A = 740 mm × 740 mm, and the size and position can be easily changed on the surface of the storage chamber. Using ANSYS CFX ver 18.1, which is a CFD commercial software, the area of the air inlet / vent port was changed to 1A, 2A, 3A, and 5A, and the hydrogen mole fraction in the storage chamber when the area changed was analyzed. Consequently, the increase in the area of the air inlet port further reduced the concentration of the leaked hydrogen as compared with that of the vent port, and improved the ventilation performance of at least 2A or more from the single air inlet port. As the area of the air inlet port increased, hydrogen was uniformly stratified at the upper part of the storage chamber, but was out of the LFL range. However, simply increasing the area of the vent port inadequately affected the ventilation performance.

A Method to Prevent CO Poisoning from Instantaneous Water Heaters (순간 가스온수기의 CO 중독사고 예방에 관한 연구)

  • Ahan, Jeong-Jin;Yeo, Chang-Hoon;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.26-30
    • /
    • 2011
  • Instantaneous water heater being not properly installed and not adequately maintained may produce fatal accidents due to carbon monoxide poisoning and suffocation. Insufficient supply of air into the gas appliance for complete burning of the fuel or blocking the outlet of the combustion gas could be a cause to increase carbon monoxide concentration in the exhaust gas of the gas appliance. In this work, the experiments are done with a collected instantaneous water heater using in domestic and the concentration of oxygen near the gas appliance and carbon monoxide in exhaust gas are observed to investigate the risk of instantaneous water heater. The concentration of oxygen near the gas appliance is reduced until 17.7% for the ratio of the ventilation area and floor area being 3.5%. If the outlet of combustion gas is blocked, the carbon monoxide concentration is steeply increasing more than 4,000ppm. Therefore, periodic checking the outlet of combustion gas is more important than vent area to reduce the risk of carbon monoxide poisoning.

A study on the program development for area optimizing of damper ports in road tunnels with transverse ventilation system (횡류식 도로터널의 급, 배기구 포트 개구면적 최적화 프로그램 개발 연구)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Min, Dea-Kee;Kim, Jong-Won;Beak, Jong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.177-188
    • /
    • 2019
  • The purpose of the optimization of the installation of supply/exhaust ports for tunnels with transverse ventilation system is to supply fresh air from outside to inside of tunnels uniformly and exhaust pollutant from tunnels properly for creating safe and clean environment for tunnel users. For this purpose, a ventilation port area optimization program was developed to obtain a uniform supply or exhaust air volume inside a great depth double deck tunnel with transverse ventilation system. In order to area optimize the developed port sizing program, the wind velocity was measured in the duct of the currently operated tunnel with semi-transverse ventilation. Also 3D cfd was performed on the same tunnel and cfd results were compared to the measured value. As a result, the error rate between the predicted value from the program and measured value was 6.72%, while the error rate between the predicted value from the program and 3D cfd analysis value was 4.86%. Both of comparison results show less than 10% of error rate. Thus It is expected that supply/exhaust port optimization design of transverse ventilation tunnel can be possible with using this large exhaust port area optimization program.

The effect of exit opening rate on exhaust gas pressure, temperature, and engine performance (배기 출구 개도율이 배기 압력과 온도 및 엔진 성능에 미치는 영향)

  • Kim, Cheol-Jeong;Choi, Byung-Chul;Park, Kweon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • Multiple devices have been installed to reduce exhaust emissions and to increase thermal efficiency. Those devices reduce the exhaust pipe opening area and increase the exhaust gas pressure. The pressure increase disturbs a gas flow and has a bad effect on the engine performance. However there is some study that NOx can be reduced with exhaust gas pressure increase. In this study an engine performance is tested with various opening ratios. The result shows that the fuel consumption rate is reduced in case of little amount of the pressure increase, and NOx is reduced with the pressure increase, while the concentration of the toxic exhaust gases are increased in the case of high back-pressure.

Pressure Recovery in a Supersonic Ejector of a High Altitude Turbofan Engine Testing Chamber (터보팬 엔진의 고고도 성능의 초음속 이젝터의 압력회복에 관한 연구)

  • Omollo, Owino George;Kong, Chang-Duk
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.6
    • /
    • pp.53-59
    • /
    • 2010
  • This research aims in finding a more optimal ejector size for evacuating engine exhaust gasses and 20% of the cell cooling air. The remaining 80% of cell cooling air pumped into the test chamber is separately exhausted from the test chamber via a discharge port fitted with flow control valves and vacuum pump. Unlike its predecessor this configuration utilizes a smaller capture area to improve pressure recovery. The modified ejector size has a diameter of 1100mm enough to evacuate 66kg/s jet engine exhaust in addition to about 20%, 24kg/s of the cell cooling air tapped from the sterling chamber. This configurations has an area ratio of the engine exit and ejector inlet of about 1.2. Simulation results of the proposed ejector configuration, indicates improved pressure recovery.

Pressure Recovery in a supersonic ejector of a high altitude testing chamber (초음속 이젝터의 압력회복에 관한 연구)

  • Omollo, Owino George;Kong, Chang-Duk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.833-837
    • /
    • 2010
  • This study aims at finding an optimal exhaust diffuser design of a high altitude testing chamber for a low bypass turbofan engine (F404-402) with thrust pound force of 17,700 and air mass flow rate of 66kg/s ejecting at a speed of Mach 1.66. The final proposed ejector size has better pressure recovery characteristics and targets to reduce operational cost at engine performance testing. Conventional high altitude test chamber layout was adopted and first drawn in two dimensions using Autocad software so as to determine the gas path, the ejector frontal size was then determined from gas dynamics equations considering traditional gas ejection method where both the engine exhaust and cell cooling air are exhausted via the ejector. Modification to a smaller ejector with an alternative secondary cell cooling exhaust port was then performed and modelled in 3D using Solid Works software.

  • PDF

A Dual-Path Full Wave Voltage Multiplier for passive RFID Tags (수동형 RFID 태그를 위한 전파 이중 경로 전압 체배기)

  • Cho, Jung-Hyun;Kim, Hak-Su;Kim, Shi-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.1
    • /
    • pp.16-21
    • /
    • 2007
  • A Dual-Path Voltage Multiplier for passive RFID Tags was proposed and fabricated by using a 0.25um CMOS process with additional steps for schottky diodes. The proposed circuit needs only 4 additional diodes, and the area increment compared to conventional one is negligible in multi-stage voltage multipliers. The simulation and measurement results show that the output power capability of proposed multiplier are about two times larger than the conventional half-wave multiplier.

A Study on the Improvement Strategies for Exhaust Performance in Commercial Kitchen Hoods (상업용 주방후드의 배기성능 개선방안에 관한 연구)

  • 박진철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.439-445
    • /
    • 2003
  • The purpose of this study is to suggest the improvement strategies for exhaust performance in composite kitchen hoods. The Exhaust only hood, the 2-way compensating hood and the 3-way compensating hood were selected, and the laboratory experiments were performed to compare the local exhaust efficiency and the indoor temperature distributions according to the variations of the hood type and supply/exhaust air velocity. The results of this study can be summarized as follows. The compensating hood has better performance than exhaust only hood in the aspect of local exhaust efficiency and temperature distribution. The 3-way compensating hood shows the best performance when the supply air velocity is about 2.7 m/s, and the 2-way compensating hood at the supply air velocity of 3.5 w/s. In the same exhaust rate condition, if the exhaust area of the hood is increased and therefore the exhaust velocity is lowered, the supply air velocity is also lowered to get the optimum performance. The optimum exhaust velocity range of the commercial kitchen hood which derived from this study is 0.48 ∼ 0.55 m/s.

KSTAR 중성입자빔 입사장치의 크라이오 배기계통 설계 개념

  • 인상렬;박미영;오병훈
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.36-36
    • /
    • 2000
  • KSTAR 토카막은 보조가열 장치로 2005년까지 1대(최종적으로는 2대)의 중성입자빔 입사장치(NBI)를 설치하여 장치의 기본 설계값에 도달할 예정이다. KSTAR NBI는 3개의 이온원을 가지고 있으며 총 수소 유입량은 70 Torr.L/s인 반면 고속 중성 입자빔량은 모두 11 Torr.L/s로 기체 배기량은 59 Torr.L/s에 달하고 압력은 장소에 따라 10-5~10-6 Torr로 유지되며 총배기속도가 1~2$\times$106 L인 펌프가 필요하다. 이때 크라이오 펌프(cryopump) 방식이 거의 유일한 해결책이라고 할 수 있다. 크라이오 펌프는 고속 입자빔 수송로의 양편에 각각 설치되는데 총면적 30m2 내외의 극저온 냉각판(cryo-pnael)들과 이를 상온 열복사로부터 보호하기 위한 열차폐(thermal shield) 및 흡기구 배플(baffle), 그리고 적절한 냉각장치로 구성된다. 시운전 단계에서는 15K GM 냉동기와 활성탄이 부착된 냉각판을 사용하는 방식과 4K GM 냉동기로 냉각하는 방식이, 최종 운전단계에서는 3.7K 액체 헬륨을 사용하는 방식이 고려되고 있다. 크라이오 펌프의 구조설계에 앞서 우선 배기속도, 흡?량, 작동압력, 냉각판 온도, 열손실량 등 설계사양을 확정하고 정리하는 일이 진행되고 있다. 또 냉각방식과 상관없이 동일한 개념으로 만들어지는 배플과 열차폐의 최적설계를 위한 몬테카를로 계산과 열전도 계산을 병행하고 있다. 이 곳에서는 KSTAR NBI 장치의 주배기계로서 사용될 크라이오 펌프의 설계방향과 전반적인 구조 및 예상성능 등에 대해 발표하려고 한다.

  • PDF

Computational Approach to Improve Diesel Engine Coolant Flow Characteristics (디젤엔진 냉각수 유동특성 개선을 위한 수치해석적 접근방법)

  • Lee, Sung-Won;Park, Sung-Young
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.1133-1136
    • /
    • 2010
  • 2600cc급 디젤엔진의 냉각수 유동특성 개선을 위한 수치해석적 방법을 제시하기 위하여 본 연구가 수행되었다. 실린더 블록 및 헤드의 유동특성 분석을 위하여 개스킷 냉각수 통로의 면적과 갯수가 중점적으로 고려되었다. 베이스 모델의 수치해석적 분석에서 입구측에 치우친 냉각수 홀의 배치에 의하여 1, 2번 실린더 헤드로만 주 유동이 발생되었다. 이러한 문제점을 개선하기 위하여 개스킷 냉각수 통로를 재설계하였다. 수정모델은 주 유동이 4번 실린더 측으로 유도되었으며, 배기밸브 사이의 유동도 개선되었다. 재설계과정에서 개스킷 냉각수통로의 전체면적을 고려치 않게 되면 유량이 줄어들게 되는 문제점이 발견되었다. 본 연구를 통하여 실린더 헤드와 블록사이의 냉각수 유동을 제어하는 개스킷의 중요성을 확인하였으며, 냉각수 유동특성 최적화는 개스킷 홀의 총 면적을 고려하여 냉각수의 총질량유량을 설계하여야 한다.

  • PDF