Hydraulic Design of Natural Gas Transmission Pipeline in the Artic Area (극한지 장거리 천연가스 배관의 유동 설계)

  • Kim, Young-Pyo;Kim, Ho-Yeon;Kim, Woo-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.58-65
    • /
    • 2016
  • Hydraulic analysis of the natural gas transmission pipeline is to determine whether adequate flow can be sustained throughout the design life of pipeline under all expected flow conditions. Many factors have to be considered in the hydraulic design of long-distance pipelines, including the nature, volume, temperature and pressure of fluid to be transported, the length and elevation of pipeline and the environment of terrain traversed. This study reviewed the available gas operation data provided by pipeline construction project in the arctic area and discussed the gas properties such as viscosity and compressibility factor that influence gas flow through a pipeline. Pipeline inside diameter was calculated using several flow equations and pipeline wall thickness was calculated from Barlow's equation applying a safety factor and including the yield strength of the pipe material. The AGA flow equation was used to calculate the pressure drop due to friction, gas temperature and pipeline elevation along the pipeline. The hydraulic design in this study was compared with the report of Alaska Pipeline Project.

A Study on the Damage Range According to Leakage Scenarios in Natural Gas Pipeline of LNG Fueled Ship (LNG 추진선의 천연가스 배관에서 누출 시나리오에 따른 피해범위에 관한 연구)

  • Lee, Yoon-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.4
    • /
    • pp.317-326
    • /
    • 2020
  • In this study, damages caused by flash fire, overpressure, and thermal radiation based on the sizes of leak holes were evaluated using the areal location of hazardous atmospheres when natural gas leaked owing to the damage of pipeline in a LNG fueled ship. In addition, environmental variables (wind speed, atmospheric temperature, and atmospheric stability) and process variables (pipe pressure and pipe length) were classified to analyze the damage impact ranges caused by various scenarios. From the results, the damage range caused by the environmental variables was the largest, followed by overpressure and thermal radiation. Additionally, for the process variables, regardless of the pressure, length, or size of the leak holes, the damage range attributed to flash fire was the most significant, and the damage range was high in the order of overpressure and thermal radiation, similar to the environmental variables. The larger the size of the leak holes, the higher the values of the environmental and process variables, and the higher the damage range caused by jet fire compared to the environmental variables.

A Study about Detection of Defects in the Nuclear Piping Loop System Using Cooling Lock-in Infrared Thermography (원전 배관 루프시스템의 냉각 위상잠금 적외선열화상을 이용한 결함 검출에 관한 연구)

  • Kim, Sang-Chae;Kang, Sung-Hoon;Yun, Na-Yeon;Jung, Hyun-Chul;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.321-331
    • /
    • 2015
  • A study on the application of cooling defect detection was performed on the basis of a preceding study on the heated defect detection in nuclear piping loop system, using lock-in infrared thermography. A loop system with piping defects was made by varying the wall-thinning length, the circumference orientation angle, and the wall-thinning depth. The test was performed using an IR camera and a cooling device. Distance between the cooling device and the target loop system was fixed at 2 m. For analyzing experimental results, the temperature distribution data for cooling, and phase data were obtained. Through the analysis of this data, the defect length was measured. The reliability of the measurements for cooling defect conditions was shown to be higher in the lock-in infrared thermography data than the infrared thermography data.

Estimates of Elastic Fracture Mechanics Parameters for Thick-Walled Pipes with Slanted Axial Through-Wall Cracks (두꺼운 배관에 존재하는 축방향 경사관통균열의 탄성파괴역학 매개변수 계산)

  • Han, Tae-Song;Huh, Nam-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.12
    • /
    • pp.1521-1528
    • /
    • 2012
  • The present paper provides the elastic stress intensity factors (SIFs) and the crack opening displacements (CODs) of a thick-walled pipe with a slanted axial through-wall crack. For estimating these elastic fracture mechanics parameters, systematic three-dimensional elastic finite element (FE) analyses were performed by considering geometric variables, i.e., thickness of pipe, reference crack length, and crack length ratio, affecting the SIFs and CODs. As for loading condition, the internal pressure was considered. Based on the FE results, the SIFs and CODs of slanted axial through-wall cracks in a thickwalled pipe along the crack front and the wall thickness were calculated. In particular, to calculate the SIFs of a thick-walled pipe with a slanted axial through-wall crack from those of a thick-walled pipe with an idealized axial through-wall crack, a slant correction factor representing the effect of the slant crack on the SIFs was proposed.

Investigation on Design Requirements of Feed Water Drain and Hydrogen Vent Systems for the Prototype Generation IV Sodium Cooled Fast Reactor (소듐냉각고속로 원형로 소듐-물 반응 압력완화계통의 급수배출 및 수소방출 설계 요건 연구)

  • Park, Sun Hee;Ye, Huee-Youl;Lee, Tae-Ho
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.170-179
    • /
    • 2017
  • We investigated design requirements of feed water drain and hydrogen vent systems for the sodium-water reaction pressure relief system (SWRPRS) of the prototype generation IV sodium cooled fast reactor (PGSFR). We evaluated the areas of the gas vent pipe of the water dump tank and the length of the water drain pipe of the steam generator to rapid drain of the water steam inside the steam generator for the normal and refueling operations, respectively. We also calculated the diameter of the gas vent pipe of the sodium dump tank which met its design pressure.

Theoretical analysis for determation of allowable free span of subsea pipeline (해저 배관의 허용 노출길이 산정에 대한 이론해석)

  • Jung Dong-Ho;Lee Yong-Doo;Park Han-Il
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.2
    • /
    • pp.54-62
    • /
    • 2003
  • The free span of a subsea pipeline due to seabed scouring can result in structural failure by severe ocean environmental loads and vortex induced vibrations. This Paper examines the safety of subsea pipelines with free spans under axial compressive load. The variation of allowable lengths of static and dynamic free spans is examined for generalized boundary conditions. The free span is modelled as a beam with an elastic foundations and the boundary condition is replaced by linear and rotational springs at each end. The static and dynamic free span curves are obtained with a function of non-dimensional parameters. A case study is carried out to introduce the application method of the curve. The results of this study can be usefully applied for the design of subsea pipelines with a free span.

  • PDF

A Study on The Safety Management of City Gas Pipelines Attached on the Bridges (교량에 설치된 도시가스배관의 안전관리에 관한 연구)

  • Yun, Young-Man;Son, Sang-Geun;Choi, Do-Kyun;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.45-52
    • /
    • 2018
  • In this study, 398 city gas pipe systems installed on the bridges were surveyed and analyzed classified characteristics about the ages, length, and remote isolation devices installed or not. As a result of analysis, 43.0% pipes have been used more than 20 years and 89.4% do not have remote cut-off devices, so this study suggest safety management ways for the issues. Chosen 76 pipes were researched stress strain characteristics by CAESAR-II which is a specialized program for stress analysis. And, when a loop is installed on the bridge pipe, effect on code stress by the location and size of the loop was performed. This study can help to improve safety level by revising criteria of new installation, inspection and diagnostic.

The Development of Measurement system using Magnetic field in Pipe (자계를 이용한 배관 내의 대상물체 판별 시스템 개발)

  • Kim, Dug-Gun;Kim, Jae-Min;Seo, Kang;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.627-628
    • /
    • 2008
  • 본 논문에서는 수직 자계를 이용한 배관 내 자성체를 측정하는 시스템을 개발하였다. 자성체 면적 변화에 따른 측정 신호의 정밀도를 높이기 위해 배관 내 자기장의 크기 및 균일도를 고려한 설계 및 해석을 하였다. 인가 자기장의 크기는 반도체 소자의 노이즈 레벨($0.4{\sim}0.6$[G])보다 크고, 대상물체의 1% 면적 변화에 따른 ${\Delta}B$의 민감도를 고려하였으며, 코어의 형상 및 길이를 변화에 따른 배관 내 자기장의 크기와 균일도를 유한요소법을 이용하여 해석하였다.

  • PDF

Comparative Analysis on the Causes and Frequency of Recent Gas Pipelines Accidents in Major Overseas Countries (해외 주요국에서의 최근 가스배관 사고의 원인과 빈도의 비교 분석)

  • Kim, Dae-Woong;Bae, Kyung-Oh;Shin, Hyung-Seop;Kim, Woo-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.53-64
    • /
    • 2018
  • Natural gas is an explosive fluid and can cause severe human/material damage when buried high-pressure pipeline is failure, and there have been reported cases of considerable human life damage to actual buried pipeline failure. In domestic cases, the length and duration of pipeline operating are short due to rapid growth. Therefore, it is a fact that the establishment of effective accident data is insufficient for the cause of the accident. In order to systematically construct an accident database, the operation history of natural gas pipeline is longer than domestic, and the cause and frequency analysis of recent natural gas pipeline related accidents occurred in overseas major countries with a long pipeline network was conducted. Then, after grasping the trend of occurrence frequency by incident cause, we tried to establish the foundation for securing the stability of the domestic high-pressure gas transport pipeline network.

MLL을 이용한 도시가스 시설의 안전 정보 시스템 구축에 관한 연구

  • 김훈희;백종배;고재욱;허문회
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.05a
    • /
    • pp.131-135
    • /
    • 1998
  • 사용이 편리하고 깨끗한 에너지에 내한 선호도가 증가하면서 가스의 보급이 금속히 확대되었을 뿐만 아니라 향후에도 지속적인 증가 추세를 보일 것으로 보인다. 특히 연탄ㆍ유류ㆍLP가스의 사용이 감소하면서 도시가스의 보급률은 전체 수용가구가 '98년에 624만 7천 가구로 49.2%의 전국 보급률을 갖고 있다. 또한 배관의 총 길이는 15,357km로 과거 5년 전 보다 2배정도 증가하였으며 시설 또한 증가 추세이다. 따라서 도시 가스를 각 가정, 사업장 등에 공급하기 위한 배관의 설치를 산업의 발달로 지하공간을 이용한 공사가 점차적으로 확산되고 있다. (중략)

  • PDF