• Title/Summary/Keyword: 방화문

Search Result 80, Processing Time 0.026 seconds

An Experimental Study on the Radiant Heat of the Firedoors in Fire (화재시 방화문의 복사열에 관한 실험적 연구)

  • Jeon, Jun-Pyo;Jeon, Soo-Min;Cho, Nam-Wook;In, Ki-Ho;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.8-13
    • /
    • 2011
  • The fire compartments which are composed of fire walls and fire doors for buildings are compulsorily required to minimize the fire damage in Korea. The performance standards of fire doors for compartments are regulated by the notification of the ministry of land, transport and maritime affairs and are mainly about the Integrity of the doors not insulation. In this study, we measured the radiant heat of six different kinds of fire doors in fire and analyzed the results and presented the reasons of the need to consider adding the radiant heat standard for fire doors to the notification.

A Study on the Fire Prevention Performance Evaluation of the Wood impregnated with flame retardant (난연제 함침 방법에 따른 목재의 난연성능 평가)

  • Moon, Sung-Woong;Lim, Kyung-Bum;Rie, Dong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.192-195
    • /
    • 2011
  • 건축물의 밀집화로 인해 화재 확산으로 인한 피해를 막기 위한 연구는 꾸준히 진행되었다. 이에 방화구획이 도입 되었으며 이 중 방화문은 화염과 연기 전파를 차단하는 문의 역할을 한다. 본 연구에서는 목재 방화문에 사용되는 목재의 난연제 처리에 따른 난연 성능을 평가하였다. 실험 결과, $0.7kgf/cm^2$ 진공압력 내에서 30분간의 함침 처리를 통해 난연성능을 확보할 수 있는 것으로 나타났다.

  • PDF

Problems and Solutions for Securing Fire Resistance Performance in Fire Protection doors (방화문 내화성능 확보에 대한 제도적 문제점 및 해결방안)

  • Kim, Juseong;Kim, Siwon;Cho, Youngduk;Kim, Jaejun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.2
    • /
    • pp.22-29
    • /
    • 2020
  • Among many fire-related laws and standards such as fire protection, fire doors are important facilities that play a role in preventing the spread of fire and smoke in the event of fire, thereby minimizing human casualties. Accordingly, the standards for performance required by applicable laws and regulations and related enforcement rules and notices have been continuously raised and the corresponding performance must be secured. However, due to the shortcomings of the relevant laws and systems, the test results of the fire doors confirmed that there was a risk of passing products. In this study, the criteria for fire-related performance were analyzed, and the performance required by other laws, in addition to simple fire protection, was identified, the criteria were organized, and the complex performance required was clearly.

Numerical Study on the Effect of Damper Position on Characteristics of Thermal Flow at the Vestibules and Fire Door (댐퍼의 위치가 부속실 및 방화문에서의 열 유동 특성에 미치는 영향에 관한 수치해석 연구)

  • Moon, Hyo-Jun;Ko, Gwon-Hyun;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • The pressurized smoke control system is important for fire safety in building because it is directly concerned with egress time of people. Even though the damper plays an essential role in the pressurized smoke control system, the phenomena of backflow smoke occurs for a certain the damper position. The research for a position of damper effects on distribution of air flow at the fire door is not performed. In this study, numerical simulation using FDS 5.5 was carried out to analyze the effect of the position of damper on flow distribution at the fire door. To simulate real situation, effects of opening and closing of fire door was considered. As a result, when HRR was between 200 kW and 400 kW, in the case which the damper was on the opposite wall of the fire door, the back flow to the vestibules was large compared to the two other cases of damper position. But when HRR was above 400 kW, Effect on damper position was not occurred.

The Prediction and Analysis of the Propagation Characteristics in Indoor Environments Using the SBR/Image Method (SBR 및 영상기법을 이용한 실내 환경의 전파특성 예측과 분석)

  • 손호경;김채영;김성진
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.199-207
    • /
    • 2001
  • In this paper, the technique of prediction and analysis on the characteristics of propagation in indoor environment is presented. This technique needs no reception sphere commonly used in 3D-ray tracing scheme, and thereby it lends us easy code realization. The validity of developed code is verified by comparing with the values of image methods and measurement. The developed technique applied to the structure of rectangular corridor with the iron door and we calculated the path loss for the variation of the iron door angle. The path loss decreased about 15 dB at the distance of30 m from the iron door and the delay spread increased approximately by four times. Based on the computation, we confirmed that indoor propagation in PCS is heavily affected by the iron door in corridor.

  • PDF

방화문의 구조설계

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.6 s.66
    • /
    • pp.36-42
    • /
    • 1974
  • 설계가 잘 되어있는 문은 사람이나 물건의 출입에 큰 지장을 주지않고 분리, 차음 및 안전등의 제기능을 충분히 발휘할 것이다. 화염이나 연기의 확산을 조지시키는 일은 안전상 가장 중요한 일 중의 하나이다. 건물의 여러곳에 위치한 문의 기능, 성능의 평가방법과 기준등은 전세계에서 논의의 대상이 되고 있다. 건물의 각부분은 내화구조구획에 의해 각각 분리될 수 있으며, 각 구획을 통하는 개구부는 화재시 자기의 기능을 충분히 발휘할 수 있는 문에 의해 차단될 수 있다. 첫째, 문은 그 문이 위치한 벽체에서 화재차단의 효과를 가져야 하며, 둘째, 피난통로의 안전을 조해하는 연소부산물이 침투하는 것을 방지하여야 한다. 그러므로 모든 방화문은, 건물에서 그 위치의 정도에 따라 연기와 화재의 확산을 막는 장벽으로서의 역할이 요구된다. 본 내용은 현재 논의되고 있는 상황에 대한 영국건축연구소의 연구보고서의 요약 소개이다.

  • PDF

A Study on the improvement the efficiency of the evacuation of the ship's crews (선박 승무원의 피난 효율 향상에 관한 연구)

  • Kim, Won-Ouk;Kim, Jong-Su
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.153-154
    • /
    • 2013
  • In this study, we used the program of three-dimensional analysis of fire for analyzing visibility of smoke flow and temperature of the accommodation area what is required for the analysis of survival of the crew. In particular, I would like to propose a method for reducing the flow rate performance in order to reduce the suffocation from the smoke of the majority of personal injury. Existing vessels are designed to close the fire door automatically when the fire alarm issued. When there is no crew that dared to escape, it can delay the spread of fire and smoke flow which is determined to be very useful to improve the survival rate of the crew. However, it can be fatal to the crew whose rooms are located on the inside of the fire door that has not completed the evacuation. In this study, we check the smoke flow rate and rate of temperature rise when crew open the fire door what is closed due to fire and compare to the structure of the blocking layer.

  • PDF