1 |
W. J. You, J. S. Nam and H. S. Ryou, "An Analysis of the Opening and Closing Condition with Various Fire Door Size in the Pressurized Room", Journal of Korean Institute of Fire Science & Engineering, Vol. 25, No. 2, pp. 132-137 (2011).
과학기술학회마을
|
2 |
National Fire Safety Code 501A, National Emergency Management Agency (2012).
|
3 |
J. H. Klote, "Design Manual for Smoke Control Systems", NISTTR 4551, NIST (1991).
|
4 |
G. Heskestad, "Fire Plumes, Flame Height and Air Entrainment", SFPE Handbook of Fire Protection Engineering 4th Vol. 1.
|
5 |
J. B. Lee, J. H. Moon, S. H. Lee and H. S. Ryou, "Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control", Journal of Korean Institute of Fire Science & Engineering, Vol. 25, No. 4, pp. 103-109 (2011).
과학기술학회마을
|
6 |
S. H. Ryu, S. K. Lee, D. H. Hong and K. R. Choi, "Characteristics of Air Egress Velocity in Vestibule Pressurization System Using the Fire Dynamics Simulator", Journal of Korean Institute of Fire Science & Engineering, Vol. 24, No. 6, pp. 153-159 (2010).
과학기술학회마을
|
7 |
K. H. Park and M. O. Yoon, "A Study for Pressure Difference and Critical Velocity by Pressurization of Elevator Shaft at High Rise Apartment", Journal of Korean Institute of Fire Science & Engineering, Vol. 25, No. 4, pp. 89-93 (2011).
과학기술학회마을
|
8 |
J. Y. Kim, D. H. Lee and H. Y. Kim, "Numerical Analysis on Features of Airflow through Open Door in Pressure Differential System", Proceedings of 2008 Winter Annual Conference, The Society of Air-conditioning and Refrigerating Engineers of Korea, pp. 463-468 (2008).
과학기술학회마을
|
9 |
S. C. P. Cheunga, S. M. Loc, G. H. Yeohd, and R. K. K. Yuenc, "The Influence of Gaps of Fire-resisting Doors on the Smoke Spread in a Building Fire", Fire Safety Journal, Vol. 41, pp. 539-546 (2006).
DOI
ScienceOn
|
10 |
K. McGrattan, R. McDermott, S. Hostikka and J. Floyd, "Fire Dynamics Simulator (Version5) Technical Reference Note", NIST Special publication 1019-5, NIST (2010).
|
11 |
"International Organization for Standardization, Fire tests. Full-scale Room Test for Surface Products, Designation ISO9705:1993(E)", American National Standards Institute, Boston, MA, USA (1993).
|
12 |
James G. Quintiere, "Principles of Fire Behavior", THOMSON (2004).
|
13 |
S. R. Lee and H. S. Ryou, "A Numerical Study on Smoke Movement in Longitudinal Ventilation Tunnel Fires for Different Aspect Ratio", Building and Environment, Vol. 41, Issue 6, pp. 719-725 (2006).
DOI
ScienceOn
|