A Study on Material Properties of Composite Panel for Impact·Blast Resistance (방호·방폭 보강용 복합패널의 재료특성에 관한 연구)

  • Kim, Woonhak;Kang, Seokwon
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.4
    • /
    • pp.373-380
    • /
    • 2016
  • In order to develop composite fiber panels that can maximize the protection and blast resistance of the existing structures by improving lightweight, high-strength and fireproof performances of the single layer material of precast panels, the basic properties of the inner and outer covers that are mixed with aramid fibers (AF) and polyester fibers (PF) were evaluated in this study. Also, a basic study was performed on the performance of composite fiber panels by testing Nano-sized composite materials that are lightweight and excellent in fire resistance for their compressive strength, bending strength and tensile strength.

A Study on verifying the reliability of $CO_2$ Fire Extinguishing Systems through the Direct Discharge Test (이산화탄소 소화설비 직접방사시험을 통한 소화성능 신뢰성 검증 연구)

  • Lee, Se-Myeong;Moon, Sung-Woong;Ryu, Sang-Hoon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.155-158
    • /
    • 2012
  • $CO_2$ 소화설비는 방호구역 내 적절한 설계농도를 확보하고 또한 일정 시간 유지해 주어야 충분한 소화성능을 발휘할 수가 있다. 따라서 시공 후에도 $CO_2$ 소화설비의 성능을 주기적으로 확인이 필요하다. 석유화학플랜트나 원자력발전소와 같은 국가 중요위험시설은 화재 발생시 대형피해가 발생할 수 있으므로 직접방사시험을 통해 소화성능을 검증할 필요가 있다. 본 연구는 국가 중요위험시설에 설치된 전역방출방식의 $CO_2$ 소화설비 중에서 표면화재 방호구역과 심부화재 방호구역을 각각 선정하여 $CO_2$ 소화설비의 소화성능을 검증해 보았다. 시험결과 표면화재와 심부화재 방호구역 모두 $CO_2$ 설계농도를 확보하고 있음을 확인하였으며, 심부화재의 경우 20분 이상 설계농도가 유지되었다. 본 연구를 통해 직접 방사시험 방법 및 판정방법을 소개하였으며, 국가 중요위험시설에는 직접 방사시험을 통한 소화설비 신뢰성 검증의 필요성을 제기하였다.

  • PDF

A Study on the Possibility of Application as a Natural Extinguishing System for $N_2$ Generator (산업용 질소발생기에 대한 청정소화설비로의 적용가능성에 관한 연구)

  • Suh, Byung-Taek;Jang, Young-Keun
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.139-144
    • /
    • 2010
  • An experimental study has been carried out to investigate the possibilities of an industrial $N_2$ generator that it replace Halon series as a natural extinguishing system. And this study comparison design standard of gas series extinguishing system with natural extinguishing system. We manufactured simple protected enclosure for analyzing fire-extinguishing performance of the $N_2$ generator. As a $N_2$ gas is exhausted on protected enclosure, a various of Oxygen concentration is measured to analyze fireextinguishing performance experimentally. The results, in case of $100m^3$ protected enclosure and $5m^3$/min $N_2$ flow rate, the Oxygen concentration is decreased below 15% within 3 minutes. And so, the $N_2$ generator make full use of an suffocating extinguishing system.

경.중수로 연계 핵연료 주기 (DUPIC)관련 핵물질 보장조치 (Safeguards)

  • 나원우;이용덕;차홍렬;김호동;홍종숙;박현수
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.447-452
    • /
    • 1995
  • 경·중수로 연계 핵연료 주기 (Direct Use of Spent PWR Fuel in CANDU : DUPIC ) 기술개발의 핵물질 보장조치(Safeguards)는 경수로 사용후 핵연료를 중수로에 재 활용하기 위한 DUPIC 공정에 대한 최적 보장조치 시스템을 구축하여, 국제 원자력 기구(IAEA) 및 국제 원자력 사회에서 핵 투명성확보 및 신뢰도를 향상시키는 것을 기술개발의 목적으로 하고 있다. DUPIC 공정은 고립된 차폐시설내의 고준위 방사선장 하에서 가동되므로 타 시설에 비해 핵 물질 전용 가능성은 희박하지만, 전 공정이 원격제어 되야 하고, 조업조건이 정복해야 하므로 기존의 보장조치 기술보다 더욱 발전된 계량관리시스템, 측정시스템 및 감시시스템 등을 개발하여야 한다. 이를 위해 본 연구에서는 각 항목에 대한 요소 분석 및 각 항목별 향후 연구방향에 대해 분석하였다. DUPIC 공정 전반에 대한 핵물질 계량관리를 위해 물질수지구역 (Material Balance Area : MBA) 및 주요측정 지점 (Key Measurement Point : KMP )을 설정하여 각 측정지점별 측정방법 및 재고검증(Inventory Verification) 방법을 분석하였다. 최적 측정시스템을 개발하기 위해 적용 가능한 비파괴분석 방법들을 분석한 결과, 핵분열성 물질 함량을 정량적으로 측정할 수 있는 수동적 중성자 측정법이 가장 적합하다는 결론을 얻었다. 또한, 감시시스템을 개발하기 위해 전용전략의 주요 요소 및 전용경로 등을 분석하였으며, 핵물질 및 시설에 대한 물리적 방호체제를 DUPIC시설에 적용하기 위하여 물리적 방호에 필요한 방호체제 요소를 분석하여 DUPIC 시설을 위한 가상적인 방호체제를 구축하였다.

  • PDF

KEPIC 화재분야의 적용성을 위한 국내.외 소방용품 성능 검증

  • Ha, Dong-Myeong;Kim, Dong-Il;Kim, Dong-Seok;Choe, Mun-Su;Yu, Ho-Jeong;Park, Sang-Hun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.218-218
    • /
    • 2013
  • 원자력발전소 화재방호기준인 KEPIC 원자력발전소 화재방호기준과 대부분의 소방시설관련 NFPA 기준에서는 소방시설 또는 소방시설에 사용하는 구성품(이하 "소방용품"이라 한다)은 관할기관(AHJ : Authority Having Jurisdiction) 받아들일 수 있는 인증(Approved) 되거나 등록된(Listed)된 제품을 사용하도록 규정되어 있다. 따라서 KEPIC 기준이 국내 원자력 발전소에 적용되기 위한 선결과제로 KEPIC 기준에서 요구하는 소방용품의 수급이 원활이 이루어질 수 있는지의 검토가 필요하다. KEPIC 기준은 대부분 NFPA 기준을 적용하고 있기 때문에 KEPIC 기준대로 설계가 이루어지려면 NFPA 기준에서 요구하는 동등이상의 구조와 성능을 갖는 소방용품으로 소방시설을 설치할 필요가 있다. 미국의 경우 일반적으로 UL인증제품이나 FM인증제품이 NFPA 기준에서 의미하는 관할기관이 요구하는 인증 및 등록된 제품으로 인정되고 있으나, 국내의 경우 소방관계법규에 근거하여 정부규격(소방방재청 고시)에 의해 주요 소방용품에 대한 의무검정제도를 운영하고 있어 원자력발전소 화재방호에 KEPIC 기준을 적용할 경우 소방용품의 수급이 원활치 않을 수 있으므로 국내에서 검정받은 소방용품으로 대체할 수 있는 지의 검토가 필요하다. 이에 따라, 국내 소방검정제도와 미국 UL인증제도를 비교하고 또한 국내 기술기준과 UL인증 시험기준이 있는 대표적 주요 소방용품 10가지에 대한 국내검정기준과 미국 UL인증 시험기준의 비교분석 등을 통하여 원자력발전소 화재방호에 KEPIC기준이 적용될 경우에 합리적인 소방용품의 적용방안에 대하여 검토하였다.

  • PDF

Uranium Residues Monitoring System (불용 핵물질 원격 방호 및 모니터링 시스템 구축)

  • Cho, Woon-Hyoung;Park, Seung-Kook;Choi, Yun-Dong;Lee, Kue-Il;Moon, Jei-Kwon
    • Annual Conference of KIPS
    • /
    • 2012.04a
    • /
    • pp.828-831
    • /
    • 2012
  • 한국원자력연구원내에는 연구실험 목적용으로 사용된 후 용도 폐기된 각종 우라늄 화합물이 수요가 증대 되어온 바, 이러한 불용 우라늄 화합물의 저장관리에 대한 체계적인 시스템의 구축이 필요하게 되었다. 이에 한국원자력연구원에서는 불용 핵물질 원격 물리적 방호시스템, UReMon(Uranium Residues Monitoring System)을 개발하였는데 이는 방사성 물질인 불용 우라늄 화합물의 물리적 방호와 관리 및 도난 방지의 목적을 지닌다. UReMon은 기존 모니터링 서비스에서 자주 사용되던 RFID나 바코드가 가지는 기술적 문제로 인한 위치확인, 도난, 훼손 등의 실태 파악에 소요되는 많은 시간과 경비를 줄이기 위하여 USN 센서와 Zigbee를 이용하여 한국원자력연구원에 기 구축되어 있는 USN기반 화재 예방시스템(KAERI-uFIPI)과의 연계를 통해 불용 핵물질의 모니터링, 위치 추적 및 재고관리의 효율성을 높인다. UReMon은 연구원 내 물리적 방호 시스템, 핵 물질 및 RI 관리, 출입통제 시스템 등에도 효율적으로 적용 가능하며, 향후 이에 대한 적용성 평가를 수행할 예정이다.

An Availability Assessment of Protection Wall Installed in LPG Filling Station (LPG 충전소 내 설치된 방호벽의 효용성 평가)

  • Lee, Jin-Han;Jo, Young-Do;Moon, Jong-Sam;Kim, Lae Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.38-45
    • /
    • 2018
  • Jet fire, pool fire, and vapor cloud explosion are major accident scenarios in LPG filling station. The protection wall would mitigate radiation effect in a jet fire. In case of a pool fire, the protection wall would restrict expanding the pool area. The protection wall might both obstruct the dispersion of released vapor and protect blast overpressure in a vapor cloud explosion scenario. In this paper, An availability assessment method of the protection wall how much reduce damage to receptors is proposed. Additionally application cases are presented for the effectiveness of protection wall in the LPG filling station. The study shows that the protection wall can effectively reduce the death probabilities of receptors located behind the wall in cases of the jet fires and the vapor cloud explosions.

A Study on the Needs to Improve the Regulations and the Design Features of Fire Protection for UAE Nuclear Power Plants (UAE원전 화재방호계통 설계특성과 화재방호규제 개선 필요성 연구)

  • Ma, Jin-Soo;Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.54-61
    • /
    • 2011
  • The study is to analysis of fire protection regulations for the nuclear power plants (NPP) in the United States, Japan, the UAE (United Arab Emirates), and Korea with the intention of exporting NPP to the UAE. Fire protection regulations for NPP for these countries permit the fire protection design and facilities in accordance with the evaluation of the potential fire hazards. However, in Korea, the NPP is a part of power generation facilities in Korea fire protection law, and the atomic energy act classifies them as the reactor and related nuclear facilities. The fire protection law and atomic energy act are different to the criteria for the fire protection of NPP. To maintain the leading position as a nuclear exporting country, the performance-based fire hazard analysis should be reasonably incorporated in the design of the fire protection system. It was suggested that the integrated requirements of the fire protection for NPP should be incorporated to the construction article for the fire protection facilities specified in paragraph 2 of Act II, being classified into the special objects to be protected against fire, which requires a performance-based design in order to incorporate the specific requirements for NPP.

Development of Protection Techniques for Explosive Demolition of RC Pillar (철근콘크리트 기둥 발파해체를 위한 방호기술 연구)

  • Chang Ha Ryu;Byung Hee Choi;Yang Kyun Kim
    • Explosives and Blasting
    • /
    • v.20 no.4
    • /
    • pp.17-28
    • /
    • 2002
  • Safety concern is one of the most important parameters in the design of building demolition by explosive blasting, Accidents were sometimes reported due to the flying chips of fragmented materials In building demolition work in urban area. Laboratory experiments were performed to investigate the failure behavior of reinforced concrete pillars under blast loading and to develop an effective protection technique. Sixteen reinforced concrete pillars were constructed. The failure behavior and the flying chip velocities were observed by means of a high-speed camera. Protection scheme was designed and the effects of several protection materials were investigated. Two kinds of non-woven fabrics and wire net were tested as protection materials. The results showed that reinforcing bar was one of the important factors to determine specific charges, and that mesh size of wire net and tied-up method affected the protection of flying chips. Control of gas effects is also a key to the control of flying chips. It was recommended to use both wire net and non-woven fabrics as primary and secondary protection materials. Such protection scheme was successfully applied to the explosive demolition of apartment buildings.

Evaluation of Ballistic Performance of Ceramic-Tile-Inserted Metal Block (세라믹 타일이 삽입된 금속 블록의 최적 방호구조 연구)

  • Lee, Seunghwan;Lee, Minhyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.3
    • /
    • pp.297-304
    • /
    • 2016
  • A numerical simulation has been performed for the penetration of a long-rod penetrator into a metal block (ceramic-tile-inserted 4340-steel plate). The impact velocity is 1.5km/s at a normal incidence angle. The first two validations are conducted for a semi-infinite block measuring the depth of penetration (DOP). The material model of ceramic is the JH-2 (Johnson-Holmquist) model. The predicted DOP values are in close agreement with the experimental data. Then, the primary simulation is performed by varying the position of the confined ceramic tile for three types of thickness of ceramic tile. The residual velocity, residual mass and residual kinetic energy of the long-rod are obtained from the simulation. Based on these predicted values, the trend of the ballistic performance of the protective structure is estimated. In addition, the mass efficiency is calculated in order to determine the performance of the ceramic-tile-inserted metal block. Finally, the optimum protective structure is identified.