• Title/Summary/Keyword: 방호벽

Search Result 62, Processing Time 0.05 seconds

A Study on the Inland Signal-fire in Chosun Dynasty (조선시대 내지봉수에 관한 연구)

  • Yoon, Jae-Woong;Lee, Chul-Young
    • Journal of architectural history
    • /
    • v.18 no.6
    • /
    • pp.47-64
    • /
    • 2009
  • This research was to analyze the inland signal-fire which is the main facility of military protective duty for safety of land in chosun dynasty. The results of this research were described separately as follows. 1. Five types of site plan of signal-fire were observed, which is circle, oval, rectangular, indeterminate form. The majorities were oval type. 2. Plan configuration of brazier which is separated with circle, rectangular type roughly was constructed with circle type generally. The height of brazier was about 3~4.5m. The diameter of brazier was 1.5~2.5m. Building base that protect ground moisture and infilteration of rainfall was found in 5 inland singal-fire, the height of it was about 0.3m~2.5m. 3. The heigh to protective wall remained until present was about 1m, the depth was about average 1.2m. 4. Entrance was mainly stairs or open type and average width was 1.0~1.2m. However the depth was almost observed as 1m, originally, it was estimated it has more depth. 5. The storage of inland signal-fire has rectangular dimension, several types of $1.8{\times}1.2m{\sim}5.7{\times}4.4m$, square(間) of $1{\times}1{\sim}2{\times}1$. The building material was stone and located below or near the brazier.

  • PDF

Properties on the Calcareous Deposit Films Formed in Submerged Zone and Tidal Zone of Steel Pipe by Cathodic Current Process (음극전류 프로세스에 의해 강관 해중부 및 간만대 부위에 형성된 석회질 피막의 특성 분석)

  • Park, Jun-Mu;Gang, Jae-Uk;Hwang, Seong-Hwa;Gang, Jun;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.351-351
    • /
    • 2015
  • 음극방식법은 피방식체에 외부전원을 인가하거나 보다 활성 금속을 전기적으로 연결하여 피방식체를 일정 전위까지 음극분극 되도록 하여 부식을 억제하는 방법이다. 해수 중 음극방식을 실시할 경우 생성되는 석회질 피막(Calcareous deposit)은 소요전류밀도 감소로 인한 희생양극의 수명연장 및 물리적 방호벽 역할을 한다. 그러나 일반적인 석회질 피막은 세라믹과 같은 화합물로써 밀착력이 매우 약하며, 적지 않은 피막 형성 시간이 소요된다. 따라서 본 연구에서는 해수 중 음극전류 프로세스를 응용하여 실제 강관의 해중부 및 간만대 영역까지 석회질 피막을 균일-치밀하게 형성시키기 위한 최적의 조건을 찾고자 하였다. 각 조건별로 제작된 석회질 피막은 SEM, EDS 및 XRD를 통해 막의 모폴로지, 조성원소 및 결정 구조를 분석하였으며, 이를 바탕으로 희생양극 종류(Al, Zn) 및 1, 3, $5mA/m^2$의 전류밀도 조건에서 부위-기간별 형성된 석회질 피막의 메커니즘을 해명하였다. 또한 밀착성과 내식특성을 평가하기 위해 테이핑 테스트, 침지-자연전위 거동을 분석 및 평가하였다.

  • PDF

Formation of calcareous deposit films on steel pipe by cathodic protection process in natural seawater and their properties (해수 중 음극방식 프로세스에 의한 강관의 석회질 피막 형성 및 특성 분석)

  • Park, Jun-Mu;Choe, In-Hye;Gang, Jae-Uk;Gang, Jun;Lee, Chan-Sik;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.192-193
    • /
    • 2015
  • 음극방식은 피방식체를 일정 전위로 음극분극 하는 원리로써 외부전원을 인가하거나 비전위의 금속을 희생양극으로 연결하여 방식하는 방법이다. 해수 중에서 음극방식을 실시할 경우 음극 표면에 용존산소 환원반응과 수소발생반응이 일어나 $OH^-$ 이온이 발생하게 된다. 이러한 반응에 의해 생성되는 석회질 피막 (Calcareous deposit)은 강구조물의 부식방지를 위한 물리적인 방호벽 역할을 하면서 용존산소의 확산 및 이동을 억제하며, 전류밀도를 감소시킨다. Potentiostat 및 rectifier를 이용하여 정전위 및 정전류 조건에서 형성된 석회질 피막을 SEM, EDS, XRD를 통해 분석하고 이를 바탕으로 양극의 종류(Al, Zn) 및 1, 5, $10mA/m^2$의 전류밀도 조건에서 실제 강관에 형성된 석회질 피막의 메커니즘을 해명하였다. 또한 석회질 피막 형성 시 Steel Wire Mesh를 설치하여 그 영향에 대해서도 분석하였다. 석회질 피막의 내구성은 침지-자연전위 및 밀착성 테스트를 통해 평가되었다.

  • PDF

Bending and Shear Capacity of Reinforced Concrete Protective Wall (휨과 전단을 고려한 철근콘크리트 방호벽 성능에 관한 연구)

  • Young Beom Kwon;Jong Yil Park
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.44-51
    • /
    • 2023
  • With the recent increase in gas energy use, risk management for explosion accidents has been emphasized. Protective walls can be used to reduce damage from explosions. The KOSHA GUIDE D-65-2018 suggests the minimum thickness and height of protective walls, minimum reinforcement diameter, and maximum spacing of reinforcements for the structural safety of the protective walls. However, no related evidence has been presented. In this study, the blast load carrying capacity of the protective wall was analyzed by the pressure-impulse diagrams while changing the yield strength of the reinforcement, concrete compressive strength, reinforcement ratio, protective wall height, and thickness, to check the adequacy of the KOSHA GUIDE. Results show that failure may occur even with design based on the criteria presented by KOSHA GUIDE. In order to achieve structural safety of protective walls, additional criteria for minimum reinforcement yield strength and maximum height of protective wall are suggested for inclusion in KOSHA GUIDE. Moreover, the existing value for minimum reinforcement ratio and the thickness of the protective wall should be increased.

Multi-Objective Optimization Study of Blast Wall Installation for Mitigation of Damage to Hydrogen Handling Facility (수소 취급시설 피해 저감을 위한 방호벽 설치 다목적 최적화 연구)

  • Se Hyeon Oh;Seung Hyo An;Eun Hee Kim;Byung Chol Ma
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.6
    • /
    • pp.9-15
    • /
    • 2023
  • Hydrogen is gaining attention as a sustainable and renewable energy source, potentially replacing fossil fuels. Its high diffusivity, wide flammable range, and low ignition energy make it prone to ignition even with minimal friction, potentially leading to fire and explosion risks. Workplaces manage ignition risks by classifying areas with explosive atmospheres. However, the effective installation of a blast wall can significantly limit the spread of hydrogen, thereby enhancing workplace safety. To optimize the wall installation of this barrier, we employed the response surface methodology (RSM), considering variables such as wall distance, height, and width. We performed 17 simulations using the Box-Behnken design, conducted using FLACS software. This process yielded two objective functions: explosion likelihood near the barrier and explosion overpressure affecting the blast wall. We successfully achieved the optimal solution using multi-objective optimization for these two functions. We validated the optimal solution through verification simulations to ensure reliability, maintaining a margin of error of 5%. We anticipated that this method would efficiently determine the most effective installation of a blast wall while enhancing workplace safety.

An Experimental Study on Development of a Window Sprinkler for Fire Spread Prevention along Building External Walls (건물 외벽 화재확산 방지용 윈도우 헤드의 개발을 위한 실험적 연구)

  • Kwark, Jihyun;Kim, Dong-Jun
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.8-13
    • /
    • 2013
  • In case of fire in a high-rise building fire can be easily spread along the building external walls dramatically if the flame comes out through broken windows. There are a few effective methods to prevent the fire spread at the moment. One is using a fire resistance window, and the other is using a window sprinkler that discharges water to resist flame in case of fire. In this study a window sprinkler which is installed on top of windows and prevents fire by discharging water when its heat-responsive element opens was tested using a large scale furnace in accordance with the standard temperature-time graph. Test result showed that one window sprinkler was able to protect a 2,400 mm wide window from fire for 2 hours and the window backside's temperature locally increased up to $126^{\circ}C$ but kept stable around $100^{\circ}C$ for the test duration.

A Study on the Function of Dike of Above-ground Membrane type LNG Storage Tanks (지상식 멤브레인 LNG 저장탱크의 방류둑 기능 연구)

  • Lee Seung-Lim;Jo Ji-Hwan;Kwon Boo-kil
    • 한국가스학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.65-72
    • /
    • 2003
  • 현행 가스법상 지상식 LNG 저장탱크에 있어서 일정 용량의 저장탱크 주위에는 액상의 가스가 누출된 경우에 그 유출을 방지할 수 있는 방류둑(Dike) 또는 이와 동등 이상의 효과가 있는 시설을 설치하도록 규정하고 있어, 실제로 모든 지상식 LNG 저장탱크에 대해서 별도의 방류둑 설치를 의무화하고 있다. 또한, 예외규정으로 국제기준(international codes and standards)에 의해 설계되는 저장탱크는 심의를 통해 방류둑 기능을 인정할 수 있도록 하고 있다. 외국의 경우 LNG 저장탱크는 일반적으로 자국내 법령보다는 국제기준에 의해 건설됨으로써 1차 탱크로부터 일정거리의 둘레에 방류둑이 필요한 단일방호식 저장탱크 이외에 이중방호식, 완전방호식(full-containment) 및 멤브레인식(membrane) 저장탱크의 경우 외부(콘크리트, 강재)탱크가 방류둑 기능을 가지고 있어 별도의 방류둑이 필요없는 구조로 규정하고 있다. 멤브레인 LNG 저장탱크의 경우 프랑스, 일본 및 한국이 설계기술을 보유하고 있고, 최근 프랑스 및 한국에서 별도의 방류둑 없는 지상식 멤브레인 저장탱크 건설이 추진되고 있으나 양국 모두 자국법의 방류둑 규정에 의해 건설의 장애요소로 작용하고 있다. 따라서 지상식 멤브레인 LNG 저장탱크의 방류둑 기능에 대한 각 국의 법령 및 기준을 조사하고, 방류둑 일체형 저장탱크(완전방호식 및 멤브레인 저장탱크)의 형식별 안전성 평가 자료를 비교 검토함으로써 방류둑 일체형 멤브레인 저장탱크의 국내 도입의 타당성을 검토하고자 하였다. 조사결과 유럽, 미국 및 일본에서는 이중벽 LNG 저장탱크의 경우 콘크리트 외부탱크가 방류둑 기능을 가지는 것으로 규정하고 있으며, 특히 EN 1473과 제정중인 prEN 265002에서는 멤브레인 저장탱크의 경우 내부 멤브레인 탱크 누출시 단열시스템과 함께 외부 콘크리트 탱크가 액밀성 및 기밀성을 동시에 가지는 것으로 별도의 방류둑이 불필요함을 규정하고 있다. 프랑스 및 일본의 방류둑 일체형 LNG 저장탱크에 대한 위험성 평가 결과를 검토한 결과 멤브레인 저장탱크와 완정방호식 저장탱크는 안전성 차원에서 거의 동일한 것으로 나타났다. 따라서 국내에서 개발한 지상식 멤브레인 LNG 저장탱크 설계모델에 대한 안전성 제고 및 안전성 평가 등을 통해 객관적인 안전성 근거가 확보된다면 동 탱크의 경우에도 완전방호식 LNG 저장탱크와 같이 외부콘크리트 저장탱크의 방류둑 기능인정이 가능할 것으로 판단된다.

  • PDF

Establishment of Integrated Design Bases Management System of APR1400 Using BIM based Algorithm (BIM기반 Algorithm을 활용한 APR1400 설계기준 통합관리 체계 구축)

  • Shin, Jaeseop;Choi, Jaepil
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.5
    • /
    • pp.52-60
    • /
    • 2019
  • The APR1400 is a 1400MWe nuclear power plant developed through national technology development project over a period about 10years. Approximately 65,000 design drawings are produced for APR1400 construction. In order to maintain consistency among numerous drawings, the highest level of design bases drawings (DBDs) are created according to design bases and this is used in the subsequent design. However, DBDs are produced and managed on a document basis and they are managed various field, it was difficult to accurately reflect the design bases information in the subsequent design. Therefore, this study recognizes limitations of the document based DBDs and develops a system that can accurately reflect the design bases information to subsequent design by adopting BIM based design bases integrated information system. Especially, by introducing DBIL(Design Bases Information Layer) concept, DBIL was created and analyzed based on five design bases(Physical protection, Fire protection, Internal missile protection, Internal flood protection, Radiation protection) applied to APR1400. In the final result DBIL set and Datasheet are integrated of room, design bases information, building data(wall, slab, door, window, penetrations). So it can be used for subsequent design automation and design verification. Furthermore, it is expected that APR1400 DBILs data can be used extensively in constructability and design economics analysis through comparison with next generation nuclear power plant.

A Study on the Operation Improvement of Door Fan Test (Door Fan Test 운영개선에 관한 연구)

  • Kong, Il-Chean;Kim, Hak-Kyung;Choi, Du-Chan;Kim, In-Tae
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.275-277
    • /
    • 2016
  • 본 논문에서는 Door Fan Test 수행 사례를 중심으로 사전 준비에 필요한 사항에 대해 분석하였다. 분석 결과 관통부 주위 개구부, 벽체 틈새 개구부 등 방화구역의 누설부위를 통해 약제가 누출되는 문제가 있었다. 원인으로는 전기배선 공사로 인해 내화충전된 부분을 제거하고 공사 후 다시 충전하지 않는 경우, 벽과 천장사이의 틈을 내화 실란트 등으로 마감을 하지 않은 경우가 대부분이었다. 이와 같이 누설부위가 많은 경우 테스트의 결과 불합격이 나오게 되며, 이러한 문제점을 개선하기 위해 사전현장조사를 통해 방호구역의 누설부위를 조사하고 보완조치를 진행한 후 테스트를 수행하는 절차가 필요하였다. 한편, 테스트 운영에 관한 사항으로는 해당 실(room)을 위한 충분한 유량 미확보, 장애물로 인한 와류형성, 차압측정구의 설치문제 등이 있었다. 이를 개선하기 위해서 공기를 유입하는 실은 외부로부터 충분한 공기유입이 있어야하며, 팬 앞의 장애물을 제거하거나 팬의 설치 위치를 조정하는 것이 필요하며, 공기의 유동이 가장 적은 곳에 측정구를 설치하는 등의 조치가 필요하다.

  • PDF

A Study on the Radioprotection Effect of Selenium and Arginine Mixtures for Reducing Radiation Damage to Police SOU (경찰특공대 요원의 방사선손상 감소를 위한 셀레늄과 아르기닌 혼합물의 방호효과 연구)

  • Geun-Woo Jeong;Hae-Suk Kim;Jae-Hyeong Park;Sung-Hyun Joo;Jae-Gyeong Choi;Se-Im Cheon;Byung-In Min
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.119-125
    • /
    • 2024
  • The purpose of this study is to examine the radioprotection effect of mixtures of selenium and arginine for development of radioprotection agents that can minimize radiation damage to police special operation unit in the event of radioactive terrorism. In this study 72 male rats were classified into 4 groups: normal group(NC Group), selenium and arginine mixtures administration group(SeAr Group), radiation exposure group(IR Group), and selenium and arginine mixture administration group followed by radiation exposure(SeAr+IR Group). The 7Gy of X-ray was irradiated to whole body of SD rats. And selenium and arginine were dministered orally at 3mg/kg and 150mg/kg once a day for 14 days. And then hematological and histological analyzes were performed on days 1, 7, and 21 after radiation exposure. In hemotological analysis, significant radioprotection wes observed in lymphocytes(p<0.05) on day 1, platelet(p<0.01) on day 7, red blood cell(p<0.01) on day 21 of radiation exposure in SeAr+IR group compared to IR group. In histological analysis, it was observed that the border of small crypt cells in the small intestine was less collapsed and the length of small crypts was relatively recovered on day 7 and showed that the number of cells and cell wall thickness were better in the prostate on day 21 in SeAr+IR group compared to IR group. Therefore, it is judged that selenium and arginine mixtures have radioprotection effect on blood and tissues due to radiation exposure. it will be helpful for research on radioprotection agents to reduce radiation damage to police special operation unit.