• 제목/요약/키워드: 방호벽

검색결과 62건 처리시간 0.047초

조선시대 내지봉수에 관한 연구 (A Study on the Inland Signal-fire in Chosun Dynasty)

  • 윤재웅;이철영
    • 건축역사연구
    • /
    • 제18권6호
    • /
    • pp.47-64
    • /
    • 2009
  • This research was to analyze the inland signal-fire which is the main facility of military protective duty for safety of land in chosun dynasty. The results of this research were described separately as follows. 1. Five types of site plan of signal-fire were observed, which is circle, oval, rectangular, indeterminate form. The majorities were oval type. 2. Plan configuration of brazier which is separated with circle, rectangular type roughly was constructed with circle type generally. The height of brazier was about 3~4.5m. The diameter of brazier was 1.5~2.5m. Building base that protect ground moisture and infilteration of rainfall was found in 5 inland singal-fire, the height of it was about 0.3m~2.5m. 3. The heigh to protective wall remained until present was about 1m, the depth was about average 1.2m. 4. Entrance was mainly stairs or open type and average width was 1.0~1.2m. However the depth was almost observed as 1m, originally, it was estimated it has more depth. 5. The storage of inland signal-fire has rectangular dimension, several types of $1.8{\times}1.2m{\sim}5.7{\times}4.4m$, square(間) of $1{\times}1{\sim}2{\times}1$. The building material was stone and located below or near the brazier.

  • PDF

음극전류 프로세스에 의해 강관 해중부 및 간만대 부위에 형성된 석회질 피막의 특성 분석 (Properties on the Calcareous Deposit Films Formed in Submerged Zone and Tidal Zone of Steel Pipe by Cathodic Current Process)

  • 박준무;강재욱;황성화;강준;이명훈
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2015년도 추계학술대회 논문집
    • /
    • pp.351-351
    • /
    • 2015
  • 음극방식법은 피방식체에 외부전원을 인가하거나 보다 활성 금속을 전기적으로 연결하여 피방식체를 일정 전위까지 음극분극 되도록 하여 부식을 억제하는 방법이다. 해수 중 음극방식을 실시할 경우 생성되는 석회질 피막(Calcareous deposit)은 소요전류밀도 감소로 인한 희생양극의 수명연장 및 물리적 방호벽 역할을 한다. 그러나 일반적인 석회질 피막은 세라믹과 같은 화합물로써 밀착력이 매우 약하며, 적지 않은 피막 형성 시간이 소요된다. 따라서 본 연구에서는 해수 중 음극전류 프로세스를 응용하여 실제 강관의 해중부 및 간만대 영역까지 석회질 피막을 균일-치밀하게 형성시키기 위한 최적의 조건을 찾고자 하였다. 각 조건별로 제작된 석회질 피막은 SEM, EDS 및 XRD를 통해 막의 모폴로지, 조성원소 및 결정 구조를 분석하였으며, 이를 바탕으로 희생양극 종류(Al, Zn) 및 1, 3, $5mA/m^2$의 전류밀도 조건에서 부위-기간별 형성된 석회질 피막의 메커니즘을 해명하였다. 또한 밀착성과 내식특성을 평가하기 위해 테이핑 테스트, 침지-자연전위 거동을 분석 및 평가하였다.

  • PDF

해수 중 음극방식 프로세스에 의한 강관의 석회질 피막 형성 및 특성 분석 (Formation of calcareous deposit films on steel pipe by cathodic protection process in natural seawater and their properties)

  • 박준무;최인혜;강재욱;강준;이찬식;이명훈
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2015년도 춘계학술대회 논문집
    • /
    • pp.192-193
    • /
    • 2015
  • 음극방식은 피방식체를 일정 전위로 음극분극 하는 원리로써 외부전원을 인가하거나 비전위의 금속을 희생양극으로 연결하여 방식하는 방법이다. 해수 중에서 음극방식을 실시할 경우 음극 표면에 용존산소 환원반응과 수소발생반응이 일어나 $OH^-$ 이온이 발생하게 된다. 이러한 반응에 의해 생성되는 석회질 피막 (Calcareous deposit)은 강구조물의 부식방지를 위한 물리적인 방호벽 역할을 하면서 용존산소의 확산 및 이동을 억제하며, 전류밀도를 감소시킨다. Potentiostat 및 rectifier를 이용하여 정전위 및 정전류 조건에서 형성된 석회질 피막을 SEM, EDS, XRD를 통해 분석하고 이를 바탕으로 양극의 종류(Al, Zn) 및 1, 5, $10mA/m^2$의 전류밀도 조건에서 실제 강관에 형성된 석회질 피막의 메커니즘을 해명하였다. 또한 석회질 피막 형성 시 Steel Wire Mesh를 설치하여 그 영향에 대해서도 분석하였다. 석회질 피막의 내구성은 침지-자연전위 및 밀착성 테스트를 통해 평가되었다.

  • PDF

휨과 전단을 고려한 철근콘크리트 방호벽 성능에 관한 연구 (Bending and Shear Capacity of Reinforced Concrete Protective Wall)

  • 권영범;박종일
    • 한국안전학회지
    • /
    • 제38권2호
    • /
    • pp.44-51
    • /
    • 2023
  • With the recent increase in gas energy use, risk management for explosion accidents has been emphasized. Protective walls can be used to reduce damage from explosions. The KOSHA GUIDE D-65-2018 suggests the minimum thickness and height of protective walls, minimum reinforcement diameter, and maximum spacing of reinforcements for the structural safety of the protective walls. However, no related evidence has been presented. In this study, the blast load carrying capacity of the protective wall was analyzed by the pressure-impulse diagrams while changing the yield strength of the reinforcement, concrete compressive strength, reinforcement ratio, protective wall height, and thickness, to check the adequacy of the KOSHA GUIDE. Results show that failure may occur even with design based on the criteria presented by KOSHA GUIDE. In order to achieve structural safety of protective walls, additional criteria for minimum reinforcement yield strength and maximum height of protective wall are suggested for inclusion in KOSHA GUIDE. Moreover, the existing value for minimum reinforcement ratio and the thickness of the protective wall should be increased.

수소 취급시설 피해 저감을 위한 방호벽 설치 다목적 최적화 연구 (Multi-Objective Optimization Study of Blast Wall Installation for Mitigation of Damage to Hydrogen Handling Facility)

  • 오세현;안승효;김은희;마병철
    • 한국안전학회지
    • /
    • 제38권6호
    • /
    • pp.9-15
    • /
    • 2023
  • Hydrogen is gaining attention as a sustainable and renewable energy source, potentially replacing fossil fuels. Its high diffusivity, wide flammable range, and low ignition energy make it prone to ignition even with minimal friction, potentially leading to fire and explosion risks. Workplaces manage ignition risks by classifying areas with explosive atmospheres. However, the effective installation of a blast wall can significantly limit the spread of hydrogen, thereby enhancing workplace safety. To optimize the wall installation of this barrier, we employed the response surface methodology (RSM), considering variables such as wall distance, height, and width. We performed 17 simulations using the Box-Behnken design, conducted using FLACS software. This process yielded two objective functions: explosion likelihood near the barrier and explosion overpressure affecting the blast wall. We successfully achieved the optimal solution using multi-objective optimization for these two functions. We validated the optimal solution through verification simulations to ensure reliability, maintaining a margin of error of 5%. We anticipated that this method would efficiently determine the most effective installation of a blast wall while enhancing workplace safety.

건물 외벽 화재확산 방지용 윈도우 헤드의 개발을 위한 실험적 연구 (An Experimental Study on Development of a Window Sprinkler for Fire Spread Prevention along Building External Walls)

  • 곽지현;김동준
    • 한국화재소방학회논문지
    • /
    • 제27권3호
    • /
    • pp.8-13
    • /
    • 2013
  • 건물 내부에서 화재 발생 시 외벽에 설치된 유리벽이나 창이 파손되며 이를 통해 화염이 밖으로 노출되면 화재는 외벽을 타고 수직상승하며 급격히 확대될 수 있다. 이를 막기 위한 효과적인 방법으로는 현재 내화유리를 사용하거나 또는 유리가 화염에 견딜 수 있도록 냉각수 등으로 방호해주는 윈도우 스프링클러 방식이 있다. 본 연구에서는 실내 유리창 상단에 설치되어 화재 시 열기류에 의해 감열체가 개방되면 유리에 냉각수를 방수하며 화염으로부터 유리를 방호해주는 윈도우 헤드를 개발하여 이의 내화성능을 평가하고자 하였으며 이를 위해 실규모 수직가열로를 이용해 유리창 시험체를 표준 온도-시간곡선에 따라 가열하여 윈도우 헤드의 내화시험을 실시하였다. 실험결과 1개의 윈도우 헤드로 최대 너비 2,400 mm의 유리창을 2시간 동안 방호하는데 성공하였으며 이 때 유리창 이면의 최고온도는 국소적으로 $126^{\circ}C$까지 상승하였으나 평균 $100^{\circ}C$를 유지하며 안정된 내화성능을 나타내었다.

지상식 멤브레인 LNG 저장탱크의 방류둑 기능 연구 (A Study on the Function of Dike of Above-ground Membrane type LNG Storage Tanks)

  • 이승림;조지환;권부길
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2003년도 추계학술발표회 논문집
    • /
    • pp.65-72
    • /
    • 2003
  • 현행 가스법상 지상식 LNG 저장탱크에 있어서 일정 용량의 저장탱크 주위에는 액상의 가스가 누출된 경우에 그 유출을 방지할 수 있는 방류둑(Dike) 또는 이와 동등 이상의 효과가 있는 시설을 설치하도록 규정하고 있어, 실제로 모든 지상식 LNG 저장탱크에 대해서 별도의 방류둑 설치를 의무화하고 있다. 또한, 예외규정으로 국제기준(international codes and standards)에 의해 설계되는 저장탱크는 심의를 통해 방류둑 기능을 인정할 수 있도록 하고 있다. 외국의 경우 LNG 저장탱크는 일반적으로 자국내 법령보다는 국제기준에 의해 건설됨으로써 1차 탱크로부터 일정거리의 둘레에 방류둑이 필요한 단일방호식 저장탱크 이외에 이중방호식, 완전방호식(full-containment) 및 멤브레인식(membrane) 저장탱크의 경우 외부(콘크리트, 강재)탱크가 방류둑 기능을 가지고 있어 별도의 방류둑이 필요없는 구조로 규정하고 있다. 멤브레인 LNG 저장탱크의 경우 프랑스, 일본 및 한국이 설계기술을 보유하고 있고, 최근 프랑스 및 한국에서 별도의 방류둑 없는 지상식 멤브레인 저장탱크 건설이 추진되고 있으나 양국 모두 자국법의 방류둑 규정에 의해 건설의 장애요소로 작용하고 있다. 따라서 지상식 멤브레인 LNG 저장탱크의 방류둑 기능에 대한 각 국의 법령 및 기준을 조사하고, 방류둑 일체형 저장탱크(완전방호식 및 멤브레인 저장탱크)의 형식별 안전성 평가 자료를 비교 검토함으로써 방류둑 일체형 멤브레인 저장탱크의 국내 도입의 타당성을 검토하고자 하였다. 조사결과 유럽, 미국 및 일본에서는 이중벽 LNG 저장탱크의 경우 콘크리트 외부탱크가 방류둑 기능을 가지는 것으로 규정하고 있으며, 특히 EN 1473과 제정중인 prEN 265002에서는 멤브레인 저장탱크의 경우 내부 멤브레인 탱크 누출시 단열시스템과 함께 외부 콘크리트 탱크가 액밀성 및 기밀성을 동시에 가지는 것으로 별도의 방류둑이 불필요함을 규정하고 있다. 프랑스 및 일본의 방류둑 일체형 LNG 저장탱크에 대한 위험성 평가 결과를 검토한 결과 멤브레인 저장탱크와 완정방호식 저장탱크는 안전성 차원에서 거의 동일한 것으로 나타났다. 따라서 국내에서 개발한 지상식 멤브레인 LNG 저장탱크 설계모델에 대한 안전성 제고 및 안전성 평가 등을 통해 객관적인 안전성 근거가 확보된다면 동 탱크의 경우에도 완전방호식 LNG 저장탱크와 같이 외부콘크리트 저장탱크의 방류둑 기능인정이 가능할 것으로 판단된다.

  • PDF

BIM기반 Algorithm을 활용한 APR1400 설계기준 통합관리 체계 구축 (Establishment of Integrated Design Bases Management System of APR1400 Using BIM based Algorithm)

  • 신재섭;최재필
    • 한국건설관리학회논문집
    • /
    • 제20권5호
    • /
    • pp.52-60
    • /
    • 2019
  • APR1400은 1992년 12월부터 2001년 12월까지 약 10여년에 걸쳐 국가선도 기술개발과제를 통해 개발된 1,400MWe급 차세대 원자력발전소 노형으로, 건설을 위해서 약 6만 5천 장의 도면이 생산된다. 또한 수많은 도면 간 일치성 유지를 설계기준(Design Bases)에 따라 가장 높은 수준의 설계기준도면(Design Bases Drawing)를 작성하여 후속설계에 가이드라인 역할로 활용하고 있다. 하지만 설계기준도면이 문서기반으로 생산 관리되고 있고, 다양한 분야에서 파편적으로 운영되어 설계기준정보를 정확하게 인지하고 후속설계에 정확하게 반영하는데 어려움이 있었다. 따라서 본 연구는 문서기반의 설계기준도면의 한계를 인식하고, BIM 기반의 설계기준 통합관리 체계를 도입하여, 설계기준 정보를 체계적이고 정확하게 후속설계에 반영 할 수 있는 체계를 구축하였다. 특히 DBIL(설계기준정보층)개념을 도입하여 5가지 설계기준(물리적방호, 화재방호, 내부비산물방호, 내부침수방호, 방사선방호)을 적용하여 DBIL생성 및 속성을 분석하였다. 최종 결과물인 DBIL set와 Datasheet에는 실(Room), DBIL, 설계기준 속성, 빌딩 데이터(벽 바닥 슬라브, 문 창문, 수직 수평관통부)를 통합 추출하여 후속설계 자동화 및 설계검증에 활용할 수 있도록 하였다. 더 나아가 APR1400 DBIL에 적용되는 5가지 설계기준의 속성을 분석하여 후속호기 및 차세대 노형과의 비교를 통한 경제성 분석 등에 폭 넓게 활용할 수 있을 것이라 예상한다.

Door Fan Test 운영개선에 관한 연구 (A Study on the Operation Improvement of Door Fan Test)

  • 공일천;김학경;최두찬;김인태
    • 한국재난정보학회:학술대회논문집
    • /
    • 한국재난정보학회 2016년 정기학술대회
    • /
    • pp.275-277
    • /
    • 2016
  • 본 논문에서는 Door Fan Test 수행 사례를 중심으로 사전 준비에 필요한 사항에 대해 분석하였다. 분석 결과 관통부 주위 개구부, 벽체 틈새 개구부 등 방화구역의 누설부위를 통해 약제가 누출되는 문제가 있었다. 원인으로는 전기배선 공사로 인해 내화충전된 부분을 제거하고 공사 후 다시 충전하지 않는 경우, 벽과 천장사이의 틈을 내화 실란트 등으로 마감을 하지 않은 경우가 대부분이었다. 이와 같이 누설부위가 많은 경우 테스트의 결과 불합격이 나오게 되며, 이러한 문제점을 개선하기 위해 사전현장조사를 통해 방호구역의 누설부위를 조사하고 보완조치를 진행한 후 테스트를 수행하는 절차가 필요하였다. 한편, 테스트 운영에 관한 사항으로는 해당 실(room)을 위한 충분한 유량 미확보, 장애물로 인한 와류형성, 차압측정구의 설치문제 등이 있었다. 이를 개선하기 위해서 공기를 유입하는 실은 외부로부터 충분한 공기유입이 있어야하며, 팬 앞의 장애물을 제거하거나 팬의 설치 위치를 조정하는 것이 필요하며, 공기의 유동이 가장 적은 곳에 측정구를 설치하는 등의 조치가 필요하다.

  • PDF

경찰특공대 요원의 방사선손상 감소를 위한 셀레늄과 아르기닌 혼합물의 방호효과 연구 (A Study on the Radioprotection Effect of Selenium and Arginine Mixtures for Reducing Radiation Damage to Police SOU)

  • 정근우;김해숙;박재형;주성현;최제경;천세임;민병인
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.119-125
    • /
    • 2024
  • 본 연구의 목적은 방사능 테러 상황에서 경찰특공대 대테러요원의 방사선 손상을 최소화할 수 있는 방사선 방호제 개발을 위하여 셀레늄과 아르기닌 혼합물의 방사선 방호효과를 규명하는 것이다. 본 연구에서는 72 마리의 수컷 SD rat을 일반군(NC Group), 셀레늄과 아르기닌 혼합물 투여군(SeAr Group), 방사선 노출군(IR Group), 셀레늄과 아르기닌 혼합물 투여 후 방사선 노출군(SeAr+IR Group)의 4개 군으로 분류하였다. 방사선은 7 Gy 엑스선을 전신에 노출하였고, 셀레늄과 아르기닌은 각각 1일 1회 3 mg/kg, 150 mg/kg이 흡수되도록 혼합하여 14일간 경구 투여였다. 방사선 노출 후 1일, 7일, 21일차에 혈액학적 분석과 조직학적 분석을 수행하였다. 혈액학적 분석에서는 IR Group에 비하여 SeAr+IR Group에서 방사선 노출 후 1일차에 림프구(p<0.05)에서, 7일차에 혈소판(p<0.01)에서, 21일차에 적혈구(p<0.01)에서 유의한 방사선 방호가 나타났다. 조직학적 분석에는 IR Group에 비하여 SeAr+IR Group에서 방사선 노출 7일차에 소장에서 소장움 세포의 경계가 적게 무너지고 소장움의 길이가 비교적 회복된 것이 관찰되었고, 21일차에 전립선에서 세포수와 세포벽의 두께가 더 양호한 것으로 관찰되었다. 따라서 셀레늄과 아르기닌 혼합물은 방사선 노출에 따른 혈액 및 조직에 대한 방사선 방호효과가 있는 것으로 판단되며 경찰특공대 대테러요원의 방사선 손상 감소를 위한 방사선 방호제 연구에 유용하게 활용될 것으로 기대된다.