• 제목/요약/키워드: 방청성능

검색결과 41건 처리시간 0.022초

기능성 방청혼화제 혼입율 변화에 따른 모르타르의 방청성능 평가 (Evaluation of anti-rust properties of mortar with functionality anti-rust agent)

  • 김상섭;이명호;윤원근;장덕배;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.104-105
    • /
    • 2014
  • In this study, fundamental properties of mortar with the variation of dosage of anti-rust agent has been tested to evaluate the effect of the anti-rust agent. Dosage of anti-rust agent was fixed as 0,3,6,9%, respectively. The variation of the flow, compressive strength and diffusion speed of chloride ion has been tested to evaluate the effect of the anti-rust agent. Results showed that flow has been smally increased. For the compressive strength, compressive strength increased with the increase of dosage of agent. For the diffusion speed of chloride, the speed decreased with the increase of dosage of the anti-rust agent. For the overall consideration, it could be identified that when the dosage of anti-rust agent was fixed as 3-6%, the mortar showed the optimum performances.

  • PDF

매시브한 해양구조물 적용을 위한 고로슬래그 혼입 콘크리트의 방청성능 평가에 관한 연구 (A Study on the Estimation of Corrosion Protection Performance of Concrete Containing Ground Granulated Blast-Furnace Slag for Massive Coastal Structures)

  • 유재강;김동석;박상준;원철;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술.기술논문발표회
    • /
    • pp.87-91
    • /
    • 2002
  • This paper investigates the corrosion inhibition and the reduction of hydration heat properties of Ground Granulated Blast-Furnace Slag (GGBFS) added concrete. Since the massive civil structure is vulnerable to the thermal crack by hydration. adiabatic temperature rising tests were performed for water-binder ratios from 43.2% to 47.3%, while replacing 15% to 50% of cement with GGBFS of equal weight. Then, the corrosion protection performance was evaluated using cylindrical specimens embedded with steel reinforcement according to the combination of 3 W/B ratios and 2 levels of chloride ion quantity. The corrosion area of the embedded steel ban was determined using the high pressure steam curing method specified in KS F 2561. The test results showed that the replacement of GGBFS was effective in reducing the hydration heat. The corrosion area of the embedded steel ban decreased as the replacement of GGBFS increased. However, the corrosion area of the steel bar was proportional to the autoclave cycle and the chloride ion quantity. Among the tested specimens, compressive strength, reduction of hydration heat, and corrosion inhibition performance were excellent when 50% of cement was replaced with GGBFS of equal weight.

  • PDF

운모상에 인산아연이 도포된 방청안료의 제조 및 성능평가 (Preparation and Performance Evaluation of Zinc Phosphate-Coated Mica Anticorrrosive Pigment)

  • 이유진;박성수;홍성수;이승호;김대성;이근대
    • 청정기술
    • /
    • 제19권3호
    • /
    • pp.257-263
    • /
    • 2013
  • 인산아연이 도포된 운모 안료(ZP/mica)를 인산, 질산아연 그리고 운모를 출발물질로 하여 제조한 후, 방청안료로 사용하였다. 주사전자현미경 및 X-선 회절분석기 등을 이용하여 제조된 안료의 형상과 결정구조를 관찰하였다. 제조된 안료와 에폭시수지를 배합하여 도막을 형성시킨 다음 전기화학적 임피던스법을 이용하여 안료의 방청성을 평가하였다. $70^{\circ}C$에서 합성된 ZP/mica 안료의 방청성이 $20^{\circ}C$에서 제조된 안료보다는 우수하다는 것을 알 수 있었다. $70^{\circ}C$에서 합성된 ZP/mica 안료표면에는 $Zn_3(PO_4)_2{\cdot}2H_2O$ 이외에도 ZnO가 동시에 생성되어 있음을 볼 수 있었다. 합성된 ZP/mica 안료의 우수한 방청성은 운모표면의 아연화합물에 의한 전기화학적 방청기구와 판상구조의 운모에 의한 장벽 방청기구의 상승작용에 기인한 것으로 생각된다.

방청시멘트 도막철근의 내부식 성능 및 부착강도 성능연구 (Corrosion and Bond Strength Characteristics of Anti-Corrosive Cement Coated Reinforcements)

  • 오병환;이종렬;조윤구
    • 콘크리트학회지
    • /
    • 제11권2호
    • /
    • pp.251-259
    • /
    • 1999
  • 최근 다양한 침해환경에 건설되는 구조물이 증가함에 따라 철근 및 강재의 부식위험성이 높아지면서, 철근 콘크리트 구조물의 내구성 저하문제가 큰 관심으로 떠오르고 있다. 특히 해양 환경하에 건설된 철근 콘크리트 구조물의 경우 구조물 외부로부터 침투되는 염분의 영향으로 인한 철근부식이 발생 및 진행되어 콘크리트 구조물에 균열, 박리 등의 손상을 받게된다. 그러므로 해양콘크리트 구조물은 염해에 대해 내구성 및 신뢰성 확보가 중요시되고 있다. 따라서, 본 연구에서는 철근의 부착강도를 크게 감소시키지 않게 하는 방법으로서 시멘트 계통의 방청시멘트를 철근에 도막한 후 내부식성능과 부착강도특성을 실험적으로 연구하였다. 본 연구결과, 방청시멘트 도막철근은 소요의 내부식성능을 갖고 있으면서도 부착강도특성도 일반철근과 유사하였으며, 앞으로 실구조물의 내구성증진을 위해 효율적으로 사용될 수 있는 토대가 될 것으로 사료된다.

EIS를 이용한 염화물 및 방청제가 첨가된 콘크리트에 매립된 철근의 방식성능 평가에 관한 실험적 연구 (A Experimental Study on the Evaluation of Anti-corrosion Performance of rebar in concrete added chloride and inhibitor using EIS method)

  • 박장현;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.134-135
    • /
    • 2016
  • To evaluate anti-corrosion performance of rebar in concrete according to the amount of chloride and inhibitor, electrochemical impedance spectroscopy(EIS) method was conducted in this study. For the anti-corrosion performance evaluation according to time, Impedance of rebar in concrete was measured before and after 5 cycle of corrosion acceleration. As a results, The impedance of rebar in concrete added chloride decreased than before corrosion acceleration. However impedance of other specimens was maintained or increased than before corrosion acceleration.

  • PDF

재유화형 분말수지와 아질산형 하이드로칼루마이트를 병용한 폴리머 시멘트 모르타르의 방청성 및 내구성 (Corrosion-Inhibition and Durability of Polymer-Modified Mortars Using Redispersible Polymer Powder with Nitrite-Type Hydrocalumite)

  • 김완기;홍선희
    • 한국건축시공학회지
    • /
    • 제12권3호
    • /
    • pp.275-283
    • /
    • 2012
  • 본 연구는 철근 콘크리트 구조물의 장수명화를 위해 고성능 다기능 폴리머 시멘트 복합체의 개발을 목적으로, 우수한 성능을 갖는 VA/E/MMA (Vinyl Acetate/Ethylene/Methyl Methacrylate) 터폴리머 분말수지와 아질산형 하이드로칼루마이트를 병용한 폴리머 시멘트 모르타르의 염화물이온 침투 저항성, 중성화 저항성, 건조수축 및 철근부식 촉진시험을 통하여 그 내구성과 방청성을 검토하는 것이다. 그 결과, 폴리머 결합재비에 관계없이 칼루마이트의 치환에 의해 폴리머 시멘트 모르타르의 내구성이 일부 저하하는 경향을 보였으나, 이는 폴리머 결합재비의 증가에 따라 크게 개선되었다. 방청성의 경우 VA/E/MMA 분말수지 사용으로 시멘트 매트릭스 내 생성된 폴리머 필름에 의한 이온 및 가스투과 저항성 증대와 칼루마이트의 이온교환반응에 따른 염화물 이온 흡착 및 아질산 이온을 방출하는 자기방청기능에 의하여 우수한 방청효과를 보였다. 따라서, 철근콘크리트 구조물의 장수명화를 위해 VA/E/MMA 터폴리머 분말수지와 아질산형 하이드로칼루마이트의 병용에 의해 우수한 방청성과 내구성을 갖는 폴리머 시멘트 복합체의 개발이 가능할 것으로 판단된다.

아연도금강판의 방식을 위한 새로운 방청안료인 이온 교환된 제올라이트의 방청 성능 (Anti-Corrosion Performance of the Novel Pigment, Ion-Exchanged Zeolite for the Protection of Galvanized Steel)

  • 김정택;정호수;유상수;이근대;박종명
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.745-751
    • /
    • 2011
  • 내부식성이 강화된 새로운 방청안료를 개발하기 위한 연구의 일환으로, 본 연구에서는 높은 내부식성을 제공하는 아연 및 세륨 이온 교환된 제올라이트를 도입하였다. 그리고 이온교환 제올라이트를 이용하여 프라이머 도료 제조 및 도장을 수행한 후, 그것의 방식성능을 측정하였다. 도장을 위한 금속 기재는 아연도금(galvanized, GI) 강판이었고, 도장된 강판의 방식성능은 electrochemical impedance spectroscopy(EIS)와 scanning vibrating electrode technique(SVET)으로 측정되었다. EIS 및 절단면의 내부식성을 확인하기 위한 SVET 측정으로부터 세륨이온 교환된 제올라이트가 가장 높은 효율을 제시하였고, 아연 및 세륨 이온 교환된 제올라이트의 경우 GI 강판에 대하여 cathodic 부식 방지제로 기여함을 확인할 수 있었다.

유기계 방청제를 혼입한 표면피복재의 유해이온 침투저항에 관한 실험적 연구 (An Experimental Study on the Resistance to Penetration of Harmful Ions in Surface Coatings Material Containing Organic Corrosion inhibitor)

  • 류화성;신상헌;이한승
    • 한국건축시공학회지
    • /
    • 제17권2호
    • /
    • pp.157-166
    • /
    • 2017
  • 일반적으로 크리트 구조물의 열화를 발생하는 가장 중요한 원인은 탄산화와 염소이온이다. 대체적으로 많은 콘크리트 구조물에서 탄산화와 염소이온으로 인하여 철근이 부식되며 이에 대한 많은 연구가 이루어지고 있다. 특히, 최근에는 보수용으로서 콘크리트 보호용 표면피복재에 방청제를 함침시켜, 염화물을 포함하고 있는 콘크리트 내 철근의 부식을 억제하는 공법도 개발되어지고 있다. 이에, 본 연구에서는 기존 보수재료 보다 부식 억제가 우수하고 열화원인인 $CO_2$$Cl^-$를 고정하는 유기계방청제를 혼입한 표면피복재의 특성 평가를 위해 촉진탄산화 및 시차 열 중량분석(TG-DTA), CASS시험를 실시하여 특성을 실험적으로 평가하였다. 실험 결과, TG-DTA 분석과 촉진탄산화를 통하여 유기계방청제 혼입으로 시멘트 콘크리트에 $CO_2$가 아민유도체와 직접적으로 반응하여 탈 양성자화 되면서 산성상태의 물질을 생성하여 안정화된 상태, 즉 $CO_2$가 고정화되어 탄산화 억제효과가 있음을 확인 하였다. 또한, CASS실험에서도, $Cl^-$ 고정 특성이 있는 유기계 방청제가 혼입된 표면피복재를 도포한 시험체의 경우, 28일째까지도 적청 발생이 관찰되지 않았으며 염화물에 의한 철근 부식을 방지하는데 우수한 성능으로 가지고 있음을 확인하였다.

철근 콘크리트 구조물용 표면 처리형 철근 부식억제제의 개발에 관한 연구 (A Study on the Development of Corrosion Inhibitor Treating Surface for Reinforcement Concrete Structures)

  • 김도겸;고경택;류금성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.239-247
    • /
    • 2004
  • 콘크리트는 내구성이 우수하고 경제적이기 때문에 강재와 더불어 건설재료로서 가장 많이 사용되어 왔다. 그러나 최근 들어 여러 연구결과와 현장점검 결과에 의하면 노출환경과 사용재료에 따라 내구성이 저하되어 실제 구조물에 심각한 문제를 일으키는 것으로 조사되고 있다. 우리나라는 삼면이 바다로 이루어져 있어 염해 피해 가능지역이 많을 뿐만 아니라 도시집중화에 따른 배기가스에 의한 중성화 현상이 심하게 발생하고 있다. 즉 염해와 중성화에 의한 철근부식이 발생할 가능성이 어느 나라 못지 않게 높다고 말할 수 있다. 본 연구에서는 먼저 철근부식을 억제 또는 방지 가능한 물질에 대해 철근부식시험을 실시하여 방청효과를 검토하여, 그 결과를 바탕으로 콘크리트로의 침투성능 및 방청성능을 고려하여 도포형 철근부식억제제를 개발하였다.