• Title/Summary/Keyword: 방전현상

Search Result 372, Processing Time 0.027 seconds

A Study on the Design of Prediction Model for Safety Evaluation of Partial Discharge (부분 방전의 안전도 평가를 위한 예측 모델 설계)

  • Lee, Su-Il;Ko, Dae-Sik
    • Journal of Platform Technology
    • /
    • v.8 no.3
    • /
    • pp.10-21
    • /
    • 2020
  • Partial discharge occurs a lot in high-voltage power equipment such as switchgear, transformers, and switch gears. Partial discharge shortens the life of the insulator and causes insulation breakdown, resulting in large-scale damage such as a power outage. There are several types of partial discharge that occur inside the product and the surface. In this paper, we design a predictive model that can predict the pattern and probability of occurrence of partial discharge. In order to analyze the designed model, learning data for each type of partial discharge was collected through the UHF sensor by using a simulator that generates partial discharge. The predictive model designed in this paper was designed based on CNN during deep learning, and the model was verified through learning. To learn about the designed model, 5000 training data were created, and the form of training data was used as input data for the model by pre-processing the 3D raw data input from the UHF sensor as 2D data. As a result of the experiment, it was found that the accuracy of the model designed through learning has an accuracy of 0.9972. It was found that the accuracy of the proposed model was higher in the case of learning by making the data into a two-dimensional image and learning it in the form of a grayscale image.

  • PDF

Detection of PD Location in Transformer Using the Multiband Electromagnetic Method (다중대역 전자파 측정법에 의한 변압기 부분방전의 위치탐지)

  • Yi, Sang-Hwa;Sun, Jong-Ho;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.85-87
    • /
    • 2005
  • 변압기의 진단을 위한 부분방전 측정방법 중 전자파를 이용한 방법은 실시간 측정이 가능하고 감도가 좋으며 외부노이즈에 강한 장점이 있어 매우 유망하다. 이러한 상황에서 단순한 부분방전의 측정뿐 아니라 나아가 변압기 내부의 부분방전 위치를 탐지 할 수 있다면, 변압기의 신속한 유지보수에 기여할 수 있을 것이다. 하지만 도체로 이루어진 변압기 외함 및 내부 구조물에 의한 공진 현상과, 결함에 따라 다른 스펙트럼의 부분방전 신호로 인하여 단일대역의 전자파 센서로는 위치탐지의 신뢰성이 떨어진다. 이에 본 논문에서는 위치 탐지용 다중대역 센서를 개발하였으며, 변압기 내부의 구조물 유무 및 부분방전 위치에 따른 신호를 분석하였다.

  • PDF

Pattern recognition of GIS partial discharges using neural network (신경망을 이용한 GIS 부분방전의 패턴인식)

  • Kang, Yoon-Sik;Lee, Chang-Joon;Kang, Won-Jong;Lee, Hee-Cheol;Park, Jong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1812-1814
    • /
    • 2003
  • $SF_6$ 가스로 절연된 GIS(Gas Insulation Switchgears)는 매우 신뢰성이 높은 것으로 평가되어왔다. 그러나 GIS 내부에서 발생하는 결함에 대하여 완전하게 배제시키지 못하고 있으며, 이러한 부분방전 활동에 의한 대부분의 결함들이 GIS의 사고를 이끈다고 알려져 있다[1]. 따라서, GIS 내부에서 발생하는 부분방전 현상의 위치와 측정은 1940년대 초반부터 관심을 가져왔으며, 현재에는 부분방전 형태의 패턴이 사용된 부분방전 검출회로 및 신호의 전파와는 무관하다는 것을 알아낸 시점에 이르렀다. 이에 따라, 본 논문에서는 $SF_6$ 가스가 봉입된 GIS 내부에서 발생하는 부분방전 형태의 패턴인식을 위한 방법으로 NN(Neural Network)의 알고리즘 중 BP(Back-Propagation) 알고리즘을 이용하였다.

  • PDF

RE(Radiated Emission) Characteristics of Partial Discharge on Stator Winding for Rotating Machines (회전기 고정자 권선의 부분발전 방사특성)

  • Kang, Dong-Sik;Hwang, Don-Ha;Lee, Ki-Chang;Lee, Jae-Bok;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2115-2117
    • /
    • 2005
  • 회전기기인 고압 전동기 및 발전기의 고정자권선에서 나타나는 운전중 부분방전 진단을 위한 방법의 하나로 비접촉식 센서를 이용한 부분방전 측정에 관한 연구가 최근 들어 활발히 진행되고 있다. 그러나 이들 권선에서 나타나는 부분방전의 방사특성에 대하여 정확한 측정이 국내에서 체계적으로 검토된 실적이 없는 실정이다. 본 논문에서는 회전기 고정자권선의 부분방전 현상을 측정하는데 이용될 비접촉식 부분방전 진단센서를 개발함에 있어서 필요한 측정 주파수대역을 선정하는데 이용하고자, 여러 종류의 고정자 권선을 대상으로 전압을 인가하여 발생되는 부분방전의 펄스의 방사특성 및 잡음특성을 실험실적으로 측정하여 고찰하였다.

  • PDF

Prebreakdown corona processes of point-to-plane gap in $SF_6$gas ($SF_6$ 가스중에서 침-평판간극의 전구코로나 과정)

  • 이복희;백용현
    • Electrical & Electronic Materials
    • /
    • v.5 no.1
    • /
    • pp.99-110
    • /
    • 1992
  • 본 논문은 고정된 바늘모양의 공기물에 의하여 형성된 불평등전계중에서 뇌임펄스전압에 대한 SF$_{6}$가스의 절연특성과 전구방전진전에 관한 것이다. 하전입자의 이동에 의하여 외부회로에 흐르는 전도전류의 측정방법에 대하여 기술하고 0.05~0.3[MPa]의 압력범위에서 섬락전압-압력특성을 측정하였으며 분류기와 광전자증배관을 사용하여 전구방전의 순시적 진전과정을 관측하였다. 전구방전은 돌기물의 선단에서 발생한 초기스트리머에 의하여 발단되며 정극성의 경우 섬락전압은 국부고전계에 매우 민감하며 리이더메카니즘으로 진전됨이 확인되었다. 전구방전현상의 극성의존성은 공간전하의 영향이 지배적이었다. 더불어 본 연구에서 제안된 전구전류의 측정기법은 불평등전계중에서의 전자사태전류, 코로나방전과 공극내에서의 부분방전의 측정에 매우 유용하게 적용될 것이다.

  • PDF

A Theoretical Analysis of Voltage and Current in Low Pressure Mercury-Argon Mixture Gas Discharge with Frequency Variation (저압 수은-아르곤 혼합기체 방전의 주파수에 따른 전압, 전류 변화의 이론적 해석)

  • Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.23-27
    • /
    • 2005
  • A fluorescent lamp which uses low pressure mercury-argon gas discharge shows the maximum current and minimum lamp voltage near 1(kHz) source frequency at constant power. For explain these phenomena theoretically, in this paper a atomic level discharge model was made and particle density and electron temperature variation were calculated using numerical method.

오로라의 신비

  • 안병호
    • Proceedings of the International Union of Geodesy And Geophysics Korea Journal of Geophysical Research Conference
    • /
    • 2003.05a
    • /
    • pp.13-13
    • /
    • 2003
  • 오로라는 태양풍과 지구자기장의 상호작용에 의해 지구의 상층대기에서 일어나는 대규모의 방전현상이다. 방전을 일으키는 전자들은 상층대기의 원자나 분자들과 충돌하여 이들을 들뜨게 하거나 이온화시킨다. 이렇게 들뜬 분자나 원자는 가시광선, 자외선 및 적외선영역의 빛을 방출한다. 오로라의 운동은 빛을 방출하는 상층대기의 운동에 의해서가 아니라 이를 야기하는 하강전자의 충격지점이 변하기 때문이다. 이것은 마치 극지방 상층대기가 TV의 브라운관과 같은 구실을 하고 오로라는 브라운관 안쪽의 형광막에 전자가 부딪쳐 빛을 내는 것과 유사한 현상이다. 따라서 오로라의 운동으로부터 지구주변의 전기장과 자기장의 변화를 알아낼 수 있다. 오로라는 화려한 빛을 발산할 뿐만 아니라 오로라타원체를 따라 강력한 전류가 발생되므로 상층대기 및 지상에 그 효과가 감지된다. 이로 인하여 지상 및 우주공간에 설치된 인류의 최첨단기기의 성능과 수명에 영향을 미쳐 사회.경제적으로 다양한 손실을 야기한다.

  • PDF

A Study on Constant Current Boosted Squarewave Driving Electronic Ballasts for High Pressure Mercury Are Iamp (정전류 쵸핑을 이용한 구형파 구동형 고압 수은 방전등용 전자안정기 설계에 관한 연구)

  • 정화진;지철근
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.1
    • /
    • pp.23-29
    • /
    • 1995
  • There are many articles about the HID lamps about it's characteristics and simulation methods for lamp design or ballast design. For the electronic ballasts of HID lamps, There are some problems caused by acoustic-resonance which destabilizes the arc of HID lamps. So, some studies suggest the methods to avoid it. For example, the methods suggested are high frequence driving over 100[kHz], and mixed frequence driving which alternates high frequence and low frequence, and squarewave driving etc. This study suggests the electronic ballast of HID lamps that solves the problems of acoustic-resonance, and can control the luminance by constant current boostes chopper of which frequence is 30[kHz] and by the squarewave driving of which frequence is 55.5[Hz.] As follows, we have the good electronic ballast for HID lamps which has the characteristics of a light weight, and a function of luminance control and a high quality luminosity and which saves electrical energy.

  • PDF

Discharge and Ozone Generation Characteristics by Permittivity of Dielectric Material installed in Water Surface Discharge (수표면 방전에 투입된 유전체의 유전율에 따른 방전 및 오존발생특성)

  • 박승록;김진규;김형표
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.56-63
    • /
    • 2003
  • A silent type ozone generator using water surface has been studied and improved its ozone generation characteristics by installing dielectric heads in the just under the surface of the wale- At this time, different permittivitis of dielectric beads were used to change the discharge condition of water surface. The current-voltage characteristics and characteristics of ozone generation quantity of the test system were investigated and discharge photos of glass beads were observed The height of Taylor cone may be the cause of the discharge bridge to decrease the ozone generation on the discharge spacing. In this study, the hight of Taylor cone could be controlled greatly by installing dielectric beads just under the water surface. Therefore a higher ozone generation also could be obtained. As the permittivity of dielectric material increased. discharge starting voltage was advanced and maximum 110 ppmy of ozone was generated by using the ferroelectric ball.