• Title/Summary/Keyword: 방재 안전성

Search Result 716, Processing Time 0.025 seconds

A study on design and performance test of fire door with high endurance performance in submarine tunnel (고내구성능을 갖는 해저터널 방화문 설계방안 및 성능시험 연구)

  • Park, Sang-Heon;Hwang, Ju-Hwan;Choi, Young-Hwan;An, Sung-Joo;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.331-346
    • /
    • 2018
  • In the tunnel of domestic high - speed railway, the main fire - fighting facility, fire - extinguishing passageway, is installed. However, due to the high pressure of the high - speed train, frequent breakage and maintenance are caused by strong shock and long - term vibration. In order to solve these problems, it is necessary to improve the fire door, but in Korea, it is installed by submitting a certificate by simple KS F 2296 performance test. At present, it is developed as a simple test certification by producing a real scale fireproof door without the theoretical examination in advance, so that a high cost for improvement is occurring in Korea. Therefore, through this study, structural analysis study which can preliminary structure review was carried out in order to design the refuge connection passage fire door and to improve the performance improvement. In order to secure the reliability of the result value, the official authentication test (KS F 2296) were compared.

Experimental study on the suppression of fire fighting by using Compressed Air Foam system (압축공기포(Compressed Air Foam) 소화시스템을 이용한 구난역 열차 화재 진압에 관한 실험적 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong;Kim, Yang-Kyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.423-432
    • /
    • 2018
  • Since the Daegu subway fire accident, people's perception of safety has increased, and all materials inside the train have been changed to incombustible materials. However, there is still a lack of development of fire extinguishing systems. Train components are mostly made of steel plates, and therefore it is very difficult to extinguish the train fire by using general fire extinguishing equipment. In this regard, this paper investigated rapid and easy methods of extinguishing the train fire by using compressed air foam systems through full-scale fire tests. To extinguish the fire of train at rescue station, window breakers were used to quickly destroy the train windows, and the compressed air foam system was inserted inside the train. As a result, the train windows were destroyed in 5 seconds, and the 11.88-MW fire was put out in 30 seconds by the compressed air foam discharged from the compressed air foam system inserted inside the train. For the future work, there is a need for further experimental studies to prevent the spread of fire and protect tunnel structures with the use of compressed air foam systems.

A study on use of quantitative risk analysis on life safety performance for the effect of fixed fire fighting system at road tunnel fires (정량적 위험성 평가를 활용한 도로터널 화재시 물분무 소화설비의 피난 안전 효과 연구)

  • Park, Kyung-Hwan;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.1-22
    • /
    • 2012
  • This paper tried to verify whether the fixed fire fighting system (FFFS) that is installed in road tunnel improves evacuation performance or not. Verification was performed according to the Disaster Prevention Facilities Installation and Management Guide at Road Tunnel. Twenty seven different fire scenarios were set up for the verification and the cases that FFFS was installed were compared with the cases that FFFS was not installed. The result of the comparison showed that the average equivalent death was reduced in 26 cases out of 27 cases when water spray extinguishing system was installed. It was confirmed that the risk when was not installed was unacceptable in Hong Kong and the Netherlands. On the other hand, it was confirmed that the risk was reduced to as low as reasonably practicable (ALARP) when was installed. The cumulative frequency of average death in case with FFFS was compared against the frequency of death without FFFS: death of one or more is about 50 times less; 10 or more is about 100 times less; and the death of more than 100 is four times less. It was verified that FFFS makes improved conditions to escape from the fires in road tunnel.

An Analysis of Flood Damage Influence by Urban Spatial Factors (도시공간적 요인에 의한 침수피해의 영향 분석)

  • Park, Kiyong;Oh, Hoo;Jeon, Won-Sik;Lee, Eui Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.238-250
    • /
    • 2020
  • This study investigated the long-term measures to minimize flood damage in the event of flooding in urban areas. The relationship between urban spatial factors and the impact of flood damage was analyzed, focusing on non-structural measures. The urban spatial factors were categorized into three parts: open space, disaster prevention facilities, and urbanization sectors. Multiple regression analysis was used to investigate how urban spatial factors influence flood damage. As a result of the analysis, the crucial factors, such as the reduced green areas and parks included in the open space sectors, resulted in an increased flood damage potential. The posterior factors, such as the population density and GRDP included in the urbanization sector concurrently led to an increase in the flood damage potential. Therefore, to better adapt to climate change, it is necessary to establish urban spatial plans strategically, such as green areas and parks. Meanwhile, the population density and GRDP are also the main factors causing flood damage. Therefore, when used appropriately in terms of resilience, it will serve as adaptations and recovery.

Development of U-Service Priority Model Based on Customer and Provider's View (수요·공급자를 통합한 u-서비스 우선순위 평가모형 개발)

  • Jang, Jae-Ho;Um, Jung-Sup
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.2
    • /
    • pp.132-147
    • /
    • 2008
  • So far ubiquitous service (u-service) priority has seldom been empirically examined based on the customer's view. It is usual to prioritize the relative importance of u-service variables by the supplier's intuition and a few specialist's experienced knowledge. Such approaches have the disadvantage that they provide only limited empirical information on the field practices in relation to u-service since customer demand of u-service is poorly defined despite abundant interest in this problem. Therefore, the aim of this research was to develop u-service priority model in the context of multi-criteria framework integrating customer and supplier's view, using high technology acceptance theory as major controlling factors. An important question was how to measure or represent criteria that is important to u-service and should be included in a priority model. The selection criteria for the model variables were derived from high technology acceptance theory and AHP approach through the analysis of frequency count, elimination of overlapping factors and brainstorming with specialists. Daegu showed top-rankings in transportation-aid service, guidance service for the eyesight disabled and u-telematics service. In contrast, disaster prevention service and industrial specialized town service ranked highly in the typical supplier's approach were not a dominant determining factor in the u-service priority. The model identified the fact that typical high priority service in terms of supplier's view did not necessarily accompany the important predictor for the u-service priority.

  • PDF

A Study on the Signal Progression System for the Disaster Prevention of Traffic Facilities - A case study of Dong Moon Ro in Kwangju City - (교통시설 재해방지를 위한 신호체계 연동화에 관한 연구 - 광주시 동문로를 중심으로 -)

  • Hwang, Eui Jin;Ryu, Ji Hyeob;Lim, Ik Hyun
    • Journal of Korean Society of societal Security
    • /
    • v.1 no.3
    • /
    • pp.59-67
    • /
    • 2008
  • The most influential facility causing traffic disaster on the urban road is intersection. Accordingly, this study elected a region for case study from seabang three-way junction, partial section of Dongmoon Ro in Kwang-Ju city, to the intersection of Mudeung Library Entrance. It is believed that the signal progression is very effective on the basis of short interval of intersection and massive traffic volume. The signal progression was simulated by using TRANSYT-7F model. The following is summary of the simulation: According to the change of cycle length, P.I. delay and fuel consumption showed the tendency of being increased in case that cycle length becomes long or short, centering around the best cycle length. In the event of progressing the cycle length, the average speed per vehicle is increased by 11.39Km per hour and P.I value is improved by 40.65% so that it resulted in 42.86% improvement in the total travel time. Moreover, the fuel consumption in line with the progression practice produced fuel saving of 31.04%.

  • PDF

A Study on Fire Facilities of Urbane Buildings (도시건축물의 소방시설에 관한 연구(I))

  • 김소수
    • Fire Science and Engineering
    • /
    • v.6 no.2
    • /
    • pp.15-24
    • /
    • 1992
  • 우리나라는 1960년대의 경제개발계획에 따른 공업화 시축의 추진으로 산업의 발달과 경제성장은 인구를 도시로 집중시키면서 도시건축물은 대형화, 고층화, 과밀화 현상을 가져왔다. 한편, 국민생활의 향상과 산업활동의 다양화로 화재발생의 주요원인이 되는 전기, 가스, 유류등의 사용량이 해마다 늘어나고 있어 화재의 위험을 가중시키고 있다. 최근 10연간('81~'90) 전국에서 발생한 화재사고는 9만 5,154건이 발생하여 인명피해 1만1,117명, 재산피해 1,859억 2,200만원의 많은 손실을 가져 왔으며, 이 중에는 서울에서 발생한 화재가 3만6,089건으로 전체의 37.9%을 차지하고 있다. 화재가 발생할 경우 대형 참사를 방지하고 귀중한 인명피해는 물론 경제적 손실을 최저로 줄일 수 있는 소방시설을 도시건축물에 설치하여 이에 대비하는 것이 무엇보다 귀중한 일이다. 이는 화재예방 또는 발생 초기에 이를 감지, 통보하고 피난하며 소화활동에 이르는 모든 방재 및 소화를 위한 소방시설의 유용성을 최대로 발휘할 수 있기 때문이다. 본 논문에서는 서울특별시를 중심으로 도시건축물에 설치된 소방시설의 유지 관리 실태와 화재시 소방시설의 이용실태를 분석하여 문제점을 도출하고 이에 대한 개선방향을 제시하므로서 예방소방행정의 발전을 기하고저 하였으며, 그 내용을 요약하면 다음과 같다. 제1장에서는 서론부분으로서 연구의 목적과 범위및 접근 방법을 서술하였고, 제2장에서는 도시소방행정의 특성 및 소방환경의 변화로 먼저 소방행정의 의의와 도시소방행정의 유형으로 예방소방과 진압소방 그리고 구급.구조업무등을 살피고. 도시소방환경변화에 따른 화재발생추세를 살펴 보았다. 제3장에서는 도시건축물에 설치하는 소방시설의 설치.유지 및 이용실태를 검사.분석하였다. '90년도 서울시내 소방서에서 실시한 소방대상물에 대한 소방검사와 방화관리자에 대한 설문조사를 실시하여 소방시설의 유지관리실태를 통계.분석한 결과, 소방시설이 양호한 소방대상물은 전체의 75.9%이며, 불량소방대상물은 24.1%로 나타났다. 그리고 화재가 발생한 소방검사대상물에 대한 화재현장 조사결과 화재시 소방시설을 사용한 소방대상물은 전체의 72.1%를 차지하고 있다. 제4장에서 는 소방시설의 문제점으로 \circled1 소방설비부실공사, \circled2 소방시설 유지관리능력부족, \circled3 소방검사제도 불합리등이며, 이에 대한 개선방향으로 \circled1 소방설비 시공자의 지도. 감독강화, \circled2 자체시설관리능력향상, \circled3 예방소방행정제도의 개선을 제시하였다. 제5장은 결론으로, 우리나라가 최근 경제성장과 산업의 발달로 도시건축물의 화재발생 위험이 가중되면서 이에 대한 소방안전대비책이 요구된다. 이에는 도시건축물에 방화시설과 소방시설을 완비하고, 그리고 자격있고 유능한 방화관리자 선임하여 자체 소방계획을 수립하여 시설점검, 정비와 유지관리를 철저히 한다면 어떠한 화재도 예방 또는 초기에 진압할 수 있고, 또한 입주검자에 대한 소방교육 및 훈련을 지속적으로 수행하여 나간다면 여하한 도시건축물의 소방안전도 그 목적을 달성하리라고 생각한다.

  • PDF

A study on the standard of effective fire facilities for the Atrium (아트리움 공간의 효과적인 방화설비 기준연구)

  • Choi, Don-Mook;Kim, Jae-Woon;Min, Se-Hong
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.6 no.1
    • /
    • pp.49-66
    • /
    • 2005
  • The purpose of this study is to present reference data to be considered in designing fur the fire safety of atrium buildings. This study deals with the characteristics of atrium buildings in the fire safety aspect, analysis of fire examples and foreign fire codes of atrium space. And con-crete factors to be consigning fur the fire facilities of atrium buildings are presented. Recently many atrium spaces have been built in Korea. They provide new experience of space with resident and pedestrians. However, because of the lack of knowledge in design principle and disaster prevention, large loss of lives is expected in an emergency situation. cion. Therefore safety ensuring from the case is urgently needed. The following is the summary on the standard of effective fire facilities for the atrium. 1. The smoke control. inside atrium must use the machine ventilation in the atrium. 2. It is desirable to divide the section between atrium and nearby living room by anti-smoke screen in order to prevent damage by smoke when fire break out. 3. It is desirable to instill an excellent fire detector like infrared light detector as a replacement of old one. 4. It is desirable to transfer from closed operating sprinkler to fire-cycle sprinkler equipment or ablative sprinkler when the height is lower than 20m.

  • PDF

A Study on the agricultural productivity of ancient reservoir through hydrological analysis - Cheong reservoir located Yeongcheon, southeastern part of Korea (수문학적 분석을 통한 한국 고대수리시설의 농업생산력 연구 - 영천 청제)

  • Jang, Cheol Hee;Kim, Hyeon Jun;Seong, Jeong Yong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.33-33
    • /
    • 2018
  • 농업이 기간산업이었던 고대사회에서 수리시설(水利施設)의 축조는 농업의 성패를 가늠하는 중요한 요소로 정치 경제 사회 전반에 걸쳐 큰 영향을 미치는 국가적인 대규모 사업이었다. 이에 따라 수리시설의 축조 시기와 배경, 축조 기술과 운영, 구조, 몽리(蒙利) 효과 및 보수(補修)와 수축(修築) 등에 대한 연구는 우리의 농경(農耕)문화사를 밝히는데 중요한 관건이 된다. 관개(灌漑) 수리시설의 축조와 정비는 수전(水田) 개발과 밀접한 연관이 있다. 제방(堤防)을 축조함으로써 주변의 수전 개발을 촉진하고, 가뭄과 홍수로부터 안전하게 전답을 유지할 수 있어 수확량을 높이게 된다. 농업생산력의 향상은 대내적 체제 정비는 물론 치열한 국가 간의 경쟁에서 우위를 점하는데 필요한 경제적 배경이 된다. 이처럼 고대수리시설은 개인과 집단 나아가 국가의 생존을 뒷받침하는 근본이었지만, 과연 우리는 그 역사성과 의미에 대해 제대로 평가를 했던 것일까? 또한, 고대수리시설의 관개 및 치수(治水) 능력은 구체적으로 어느 정도였으며 근대에 비하면 어느 정도였을까? 일부 수리시설에 대해 관개면적을 추정한 경우는 있으나, 그 예도 많지 않을뿐더러 시기적인 변천 양상을 제대로 반영하고 있지 못하는 것이 현실이다. 본 연구는 고대로부터 원형을 비교적 잘 간직하고 있는 수리시설 중 경북(慶北) 영천(永川)의 청제(菁堤)를 대상으로 고고학적 역사학적 입장에서 보다는 수문학적(水文學的) 농업수리학적(農業水利學的) 관점에서 저수량(貯水量) 및 관개(灌漑) 면적에 따른 농업생산력을 살펴보았다. 지형 및 GIS (Geographic Information System) 정보를 이용하여 저수지의 규모 및 관개 면적을 추정하였으며 수문학적 해석 모형(模型)인 CAT(Catchment hydrologic cycle Assessment Tool)(김현준 등, 2012)을 이용하여 저수량 및 관개 가능량을 분석하였다. CAT은 공간 단위별로 침투(浸透), 증발(蒸發), 지하수(地下水)흐름 등의 모의(模擬)가 가능하도록 개발된 모형이다. 특히, 농업용 저수지 및 홍수방재용(洪水防災用) 저류(貯留)시설 등의 저류량(貯留量) 및 방류(放流量)에 대한 모의가 가능하다(장철희 등, 2012). 고대수리시설의 저수량 및 관개 면적에 따른 농업생산력을 공학적 수문학적으로 해석하는 연구는 과거물 관리 및 생산력의 실태를 좀 더 자세히 파악할 수 있는 토대가 될 것이며, 역사학적 자료와의 비교 분석을 통해 우리나라 고대수리시설의 역사성 및 우수성을 찾을 수 있을 것으로 판단된다.

  • PDF

Bond Behavior of Epoxy Coated Reinforcement Using Direct Pull-out Test and Beam-End Test (직접인발시험과 보-단부 시험을 이용한 에폭시 도막 철근의 부착특성)

  • Kim, Jee-Sang;Kang, Won Hyeak
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.3
    • /
    • pp.271-278
    • /
    • 2019
  • The corrosion of reinforcements embedded in concrete causes severe deterioration in reinforced concrete structures. As a countermeasure, epoxy coated reinforcements are used to prevent corrosion of reinforcements. When epoxy coated bars are used, the resistance of corrosion is excellent, but epoxy coating on the bars have a disadvantage of reduction in bond capacity comparing to that of normal bars. Therefore, it is necessary to confirm the bond performance of epoxy coated reinforcements through experimental and analytical methods. Bond behaviors of epoxy coated bars for various diameters of 13 and 19mm and thicknesses of cover concrete of 3 types(ratio of cover to bar diameter) are examined. As the diameters of the epoxy coated bars increase, the difference of bond strength between epoxy coated and uncoated bars also increases and damage patterns showed pull out failure. In addition, finite element analysis was performed based on the bond-slip relationship obtained by direct pullout test and compared with the flexural test results. It is considered that flexural member test is more useful than pullout test for simulating the behavior of actual structure.