• Title/Summary/Keyword: 방음시설

Search Result 44, Processing Time 0.024 seconds

Design of Soundproof Facilities for the Test Track (경부고속철도 시험선구간의 방음시설 설계현황)

  • ;;;J.P. Clairbois;D. Gardin
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.361-368
    • /
    • 1998
  • This paper sums up the study of the soundproof facilities to be placed on the test track section within the Seoul-Pusan H.S.T project. The objective of this study is to determine optimum design of soundproof including height, length, location, sound absorbing materials for test track(chonan-taejon). This paper shows the model to design the shape and materials of noise barrier for high speed trains(TGV, ICE, etc). Noise prediction is to be conducted by MITHRA. Various parameters affecting the noise propagation outdoors are surveyed and discussed in relation to H.S.T. noise.

  • PDF

Deterioration Evaluation Method of Noise Barriers for Managements of Highway (고속도로 방음벽 유지관리를 위한 방음벽 노후도 평가 방안)

  • Kim, Sangtae;Shin, Ilhyoung;Kim, Kyoungsu;Kim, Daae;Kim, Heungrae;Im, Jahae;Lee, Jajun
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.4
    • /
    • pp.387-399
    • /
    • 2019
  • This research aimed to prepare the classification of the damage types and the damage rating system of noise barriers for expressway noise barriers and to develop deterioration evaluation method of noise barriers by reflecting them. The noise barrier consists of soundproof panels, foundations and posts and the soundproof panels with 10 different types of materials are used in a single or mixed form.In this paper, damage of soundproof panel shows a single or composite damage, and thus a evaluation model of deterioration has been developed for noise barriers that can reflect the characteristic of noise barriers. Materials used mainly for soundproof walls were divided into material types for metal, plastic, timber, transparent and concrete. And damage types for noise barrier were classified into corrosion, discoloration, deformation, spalling and dislocation and damage types were subdivided according to the noise barrier's components and materials. Damage rating was divided into good, minor, normal and severe for each major part of noise barrier to assess damage rating of soundproof panel, foundation and post. The deterioration degree of noise barrier was evaluated comprehensively by using the deterioration evaluation method of whole noise barrier using weighted average. Deterioration evaluation method that can be systematically assessed has been developed for noise barrier using single or mixed soundproof panel and noise barrier with single or complex damage types. Through such an evaluation system, it is deemed that the deterioration status of noise barrier installed can be systematically understood and utilized for efficient maintenance planning and implementation for repair and improvement of noise barriers.

A way of reducing blind spot of civil defence later in urban area (도심지역의 민방위경보 사각지역 해소 방안 고찰)

  • Lee, Yong-Tae;Paek, Myung-Sun;Lee, Yong-Hoon;Kim, Kwang Yong;Lee, Seoung Hyung;Kim, Tae Shin;Kwan, Dae Bok;Choi, Seoung Jong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.06a
    • /
    • pp.307-309
    • /
    • 2013
  • 국내에서는 1975년부터 민방위 기본법을 재정하여 민방위 경보 서비스를 실시하고 있으며 인구 5천이상의 도심지역의 민방위 경보를 위해 중앙과 시도를 중심으로 구축된 민방위 경보시스템이 운영되고 있다. 그러나 기존 재난경보시설과의 연동이 부족함으로써 특히 도심지역에서는 건물로 인한 민방위 경보 사각지대가 발생하면서 민방위경보 수신의 한계를 갖게 되었다. 이에 본 본 논문에서는 도시 소음차단 방음시설이 잘된 도심지역의 대형빌딩이나 아파트 내부 등 옥내에서의 민방위경보 사각지대를 해소하는 방안을 중심으로 도심지역의 민방위경보 수신 커버리지를 확대하는 방안에 대해 고찰한다.

  • PDF

K 문화센터 턴키설계사례

  • 김덕수;연창근
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.8
    • /
    • pp.32-39
    • /
    • 2002
  • K 문화센터는 공연 및 전시를 위한 고품격 문화 시설로서 주요 시설인 공연장은 규모 및 용도에 따라 오페라 극장, 콘서트홀, 실험극장으로 구분되어 있다. 공연장은 타 공간에 비해 높은 정숙도와 쾌적한 내부 환경, 피난 계획 등을 필요로 하기 때문에, 이를 만족하기 위해서는 실의 특성에 적합한 공조 설비, 방음.방진 및 방재 설비 등이 뒷받침되어야 한다. 따라서 본 설계사례에서는 최고 수준의 공연장 계획에 적합하도록 각 분야별로 적용된 시율레 이션 기법 및 신공법과 함께 주요 기계설비 계획에 대해 소개하고자 한다.

  • PDF

Reducing Effect of Traffic Noise Soundproof Facilities (방음시설의 소음저감효과에 관한 연구)

  • Jeon, Gi-Seong;Park, Young-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • In order to propose the design and installation information of vegetation belt, field investigation were carried out in the noise pollution control facilities of highway and the streets of a city for two years(1998~1999), and field tests were performed to analyze the noise attenuation effect of them. The noise pollution control facilities were generally classified into three types (noise barrier and vegetation belt type, mounding and vegetation belt type, vegetation belt type only). Most soundproof facilities were proved the noise reduction effects. But according to width, height, structure, auditory distance and planting forms of them, difference of noise reduction effects were investigated. The soundproof facility was suitable the mounding and vegetation belt type in the consideration of road environment, and the installation standard of vegetation was estimated that the width of vegetation was at least 20m and the length of that was 2 times in the distance from noise source.

  • PDF

Site Mitigation Plan for Noise Sources from Construction Sites by Developing Movable Noise Barriers (건설공사장 이동식 방음시설물의 음향특성)

  • Lee, Sung Chan;Chung, Jin Yun;Im, Jung Bin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.58-64
    • /
    • 2015
  • There are a lot of different types of noise from construction site and it depends on construction stage, equipment type and number of operating equipments. The problem is that the almost noise from construction site is high level and some kinds of noise levels are over 100 dB. In addition, if construction site is located in downtown, there are a few options to reduce noise level. Therefore several site mitigation plans were developed to reduce different types of construction noises such as breaker work, gang form and asphalt saw. They were applied in site and evaluated noise reduction performance. The test result of site insertion loss was between 4~8 dB depends on the equipment and type of work.

Noise Prediction and Design of Soundproof Facilities for the High Speed Train (고속열차(TGV) 주행시 연변에서의 소음예측 및 방음시설설계)

  • ;J. P. Clairbois
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1106-1115
    • /
    • 1999
  • This paper sums up the study of the soundproof facilities (noise barriers) to be placed on the test track section within the Seoul-Pusan H.S.T. project. The objective of this study is to determine optimum design of soundproof including height, length, location, sound absorbing materials for test track(chonan-taejon). This paper shows the model to design the shape and materials of noise barrier for high speed trains(TGV, ICE, ect). The design of soundproof facilities is to be conducted by MITHRA for the prediction of noise impact of the TGV and for optimising noise barriers in order to reduce the noise generated by high speed trains. A number of computer simulations are carried out in order to determine the specification of noise barrier on test track.

  • PDF

A study on the improvement for installation guide of soundproofing facilities in construction site (공사장 방음시설 설치기준 개선방안에 관한 연구)

  • Park, Young-Min;Kim, Kyoung-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.4
    • /
    • pp.361-367
    • /
    • 2013
  • Noise and vibration occurs during construction intermittently, but with the most arise complaints. There is a need to efficiently manage the construction noise and vibration problems because in case a residential facility that requires calmness around the construction site adversely affects the living conditions of nearby residents. The ministry of environment has mandating the installation of soundproofing facilities for the management of construction noise. In order to enforce a particular construction, the mandatory install with soundproofing facilities before the start of construction, and after construction. However, Installation guide of soundproofing facilities for construction sites were not considered affected areas by noise and there is no provision of performance evaluation for soundproofing facilities. In this study, investigated the status and problems of the installation guide for soundproofing facilities in construction sites, we propose an efficient installation guide of soundproofing facilities for the reduction construction noise.

Improvement Plan of Fire-Related Laws of Disaster Prevention Facilities of Road Tunnels (도로터널 방재시설의 소방관계법령 개선방안)

  • Seo, Hyo-Seon;Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.124-131
    • /
    • 2019
  • When a fire occurs in a road tunnel, it is likely to develop into a major disaster because of its sealed structural characteristics. Because of this, a range of disaster prevention facilities should be installed, and they should show their appropriate functions in fire prevention and response. In addition, the installation of essential disaster prevention facilities is missing due to the lack of considering an extension of continuous tunnels and soundproof tunnels. For these reasons, it was judged that an amendment to the law would be necessary. Therefore, this paper reviewed the changes in domestic laws related to the disaster prevention facilities of road tunnels, and the results of the study on the parts that need to be revised in the fire-related laws through a comparative analysis between laws are as follows. First, consecutive tunnels should consider the sum of the extensions of the individual tunnels and ensure that the soundproof tunnels are included in the category of tunnels in the law. In this way, the necessary disaster prevention facilities should be installed. Second, it is necessary to secure a legal justification for installing disaster prevention facilities in tunnels. Therefore, it is essential that water mist fire extinguishing system facilities, emergency broadcasting facilities, and leading lights, which are excluded from installation in tunnels, are specified in the Fire-related laws. Third, to specify in the law that air respirators must be provided in the tunnel is necessary from the viewpoint of the field response. Accordingly, it will make a great contribution to the fire-fighting activities and the life-saving efforts by fire-fighters.

Prediction of Reduction of Traffic(Railroad) Noise using Soundproof Tunnel in a high-rise apartment building (고층 주거지역에서 터널형 철도 방음 시설의 소음 저감 예측)

  • 김준엽;나희승;엄기영;조준호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.843-848
    • /
    • 2001
  • Railroad noise is one of the main causes of environmental impact. Whenever a new railroad line is planned or a housing project near an existing railroad is proposed, an estimate of the relevant noise levels is usually required. For this, it is necessary to quantify those parameters that affect the railroad noise. This paper deals with an estimation of railroad noise using soundproof tunnel in a high-rise apartment building

  • PDF