• Title/Summary/Keyword: 방열판

Search Result 169, Processing Time 0.025 seconds

Experimental and Numerical Studies on the Failure of Curtain Wall Double Glazed for Radiation Effect (커튼월 이중 유리 외장재 파단에 대한 실험 및 수치해석 연구)

  • Nam, Jiwoo;Ryou, Hong-Sun;Kim, Dong-Joon;Kim, Sung-Won;Nam, Jun-Seok;Cho, Seongwook
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.40-44
    • /
    • 2015
  • National and international standards for curtain wall glass are focused on wind pressure and insulation performance, but disasters such as fires and earthquakes are not considered. Failure of curtain wall glass during a fire in a skyscraper increases the loss of lives and property due to the spread of fire. Therefore, the fire resistance of curtain wall glass should be investigated, and technology to prevent glass failure should be developed to prevent fire damage due to spreading fire. It is important to predict the starting point of cracks and the cause of glass failure to prevent it effectively using the limited water in a skyscraper. In this study, double glazed glass was exposed to a radiator in an experiment performed to analyze the thermal characteristics. The results show that glass that was not directly exposed to high temperature and pressure was broken. To identify this failure case, numerical analysis was performed. Three glass specimens were installed in an ISO 9705 room and exposed to radiation using a radiator, and a thermocouple was used to measure the temperature on the surface of the glass. Widely used double glazed glass was analyzed for weakness to fire.

Development of Epoxy/Boron Nitride Composites for High Heat Dissipation of Metal Copper Clad Laminate (MCCL) (Metal Copper Clad Laminate (MCCL)의 고방열 특성을 위한 Epoxy/BN 복합체 개발)

  • Choi, Ho-Kyoung;Choi, Jae-Hyun;Choi, Bong-Goo;Yoon, Do-Young;Choi, Joong-So
    • Korean Chemical Engineering Research
    • /
    • v.58 no.1
    • /
    • pp.64-68
    • /
    • 2020
  • In this study, metal copper clad laminate can be prepared using epoxy composite filled with thermally conductive fillers. In order to improve the thermal conductivity of epoxy composites, it is important factor to form conductive networks through appropriate packing of conductive fillers in epoxy composite matrix and to decrease the amount of thermally resistant junctions involving a epoxy composite matrix layer between adjacent filler units. This is because epoxy has a thermal conductivity of only 0.2-0.3W, so in order to maintain high thermal conductivity, thermally conductive fillers are connected to each other, so that the gap between particles can be reduced to reduce thermal resistance. The purpose of this study is to find way to achieve highly thermally conductive in the epoxy composite matrix filled with Al2O3 and Boron Nitride(BN) filler by filler loading and uniform dispersion. As a results, the use of Al2O3/BN hybrid filler in epoxy matrix was found to be effective in increasing thermal conductivity of epoxy composite matrix due to the enhanced connectivity offered by more continuous thermally conductive pathways and uniform dispersion without interfacial voids in epoxy composite matrix. In addition, surface treatmented s-BN improves the filler dispersion and adhesion between the filler and the epoxy matrix, which can significantly decrease the interfacial thermal resistance and increase the thermal conductivity of epoxy composite matrix.

Full-Wave Analysis, Design and Fabrication of Duplexer by Mode Matching Method for Ka-Band Transponder (모드정합법에 의한 Ka-밴드 위성중계기용 듀플렉서의 Full-Wave 분석 및 설계${\cdot}$제작에 관한 연구)

  • Lee, Yong-Min;Ra, Keuk-Hwan
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.8
    • /
    • pp.36-44
    • /
    • 1999
  • This paper presents the design and fabrication of the duplexer for a Ka-band satellite transponder which is analyzed transmission characteristics by calculating the generalized scattering matrix using mode matching method. It is composed of 2 bandpass filters, coupled with H-plane T-junction having symmetrical inductive iris and E-plane metal insert structures. Compared with the size and weight of the Rx and Tx filter loaded with a transponders respectively, those of the duplexer can be effectively reduced. In a high power transmission, the variation of the filter characteristics is minimized by the scheme that irises are extended to the exterior of H-plane of the waveguide. This scheme needs no extra heat sinks for dissipating high power. The duplexer is designed to improve the simplification, durability and reliability by eliminating tuning screws, which have been used to compensate for the characteristics of fabricated filters. The bandpass filters of the duplexer show the insertion loss of less than 1.2 dB and the return loss in excess of 15 dB. The isolations of more than 65 dB have been achieved between Rx and Tx filter.

  • PDF

Optical Design of a Multilayer LED Array Light Source and Illumination Optics for a Large-Screen LC Projection Display System (대화면 액정 화상 투영기용 다층 배열 엘이디 광원 및 조명광학계 설계)

  • Kim, Hyun Hee;Han, Dong Jin;Kim, Jin Seung
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.4
    • /
    • pp.226-232
    • /
    • 2015
  • A double-layer LED array together with an illumination optical system is proposed as a possible light source for LC projection display systems for large screens, up to $8m{\times}6m$ (400 inches diagonal). The heat dissipation problem of the LED array is solved by arranging the LEDs in double layers, and thermal analysis shows its effectiveness. The light from the LEDs in the back layer can be transmitted through the front layer without significant loss by arranging the LEDs in non-overlapping positions in the two layers and inserting suitable microlenses between the two layers and holes in the first layer. Together with the double-layer LEDs, an illumination optical system is designed to illuminate liquid crystal panels with good uniformity and appropriate matching with the projection optics.

A Study on the Heat Storage System for Chemical Heat Pump Using Inorganic Hydrates (III) -Numerical Analysis of Heat Transfer in Ca(OH)2 Dehydration Packed Bed- (화학열펌프에 있어서의 무기수화물계 축열시스템에 관한 연구(III) -Ca(OH)2 탈수반응층의 전열해석-)

  • Park, Young-Hae;Lee, Young-Sei;Kim, Jong-Shlk
    • Applied Chemistry for Engineering
    • /
    • v.7 no.6
    • /
    • pp.1181-1191
    • /
    • 1996
  • To develope chemical heat pump, which is operated by heat of high temperature using available energy sources such as solar heat and many kinds of waste thermal energy we have studied theoretically the enhancement effects of inserted fins on the rate of heat transfer and reaction in cylinderical $Ca(OH)_2$ packed bed reactor. The results obtained by numerical analysis about profiles of temperature, completion time of reaction and exothermic heat amount released from the reactor read as the inserted copper fins in reator reduce the completion time of dehydration reaction in packed bed by half, and the rate of thermochemical reaction depends on the temperature and concentration, and it is also governed by the boundary conditions and the rate of heat transfer in the particle packed bed.

  • PDF

Thermal-Fluid Analysis with Flow Loss Coefficient on the Inlet and Exhaust Duct of Wheel-Loader (휠로더 흡배기구의 유동손실계수를 적용한 열유동해석)

  • Jeong, Chan-Hyeok;Lee, Jae-Seok
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.97-104
    • /
    • 2017
  • In this study, we verify the accurate numerical analysis and simplify the perforated plate of inlet and exhaust duct using porous media for the cost reduction and the efficiency improvement of thermal-fluid analysis to evaluate cooling performance of wheel-loader. The flow loss coefficient of the perforated plate is defined by the experiment result. To define analytically the flow loss coefficient of the perforated plate, we calculate the pressure drop of unit-cell and compare to experiment result. Finally, we compare the heat balance test and the simplified simulation result on the inlet and exhaust duct of wheel-loader. After this study, we verify the applicability of the simplified analysis method on the inlet and exhaust duct of wheel-loader. And, foundation which can carry out effectively the evaluation and improvement for cooling performance of wheel-loader is prepared.

Analysis of the Impact of Cooling Methods in High-Performance Processors (고성능 프로세서에서의 냉각 기법의 효율성 분석)

  • Choi, Hong-Jun;Ahn, Jin-Woo;Kim, Cheol-Hong
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2010.06b
    • /
    • pp.313-317
    • /
    • 2010
  • 최근에는 반도체 공정 기술의 발달로 인하여 프로세서의 성능은 급속도록 발전하였다. 하지만 프로세서에서 소모되는 전력이 급속도록 증가하고, 이에 따라 발생된 높은 온도는 프로세서 신뢰성에 부정적인 영향을 미치고 있다. 그러므로 최근의 프로세서 설계 시 전력, 온도등도 성능과 함께 중요한 고려사항이다. 프로세서의 신뢰성에 치명적인 영향을 미치는 고온현상을 해결하기 위해서 여러 가지 연구가 이루어지고 있다. 대표적으로 방열 판, 냉각 팬 등을 이용한 기계적인 기법과 동적 온도 관리 기법, 연산 이관 기법등을 적용한 구조적인 기법이 활발하게 연구되고 있다. 이러한 기법들의 적용으로 프로세서의 온도를 효과적으로 제어할 수 있게 되었으나 기계적인 냉각 기법은 냉각 효율성이 높지 않다는 단점이 존재하고, 구조적 설계 기법을 통한 냉각기법은 온도를 제어하기 위해 프로세서의 성능을 저하시키는 치명적인 단점이 존재하기 때문에 두 기법 모두 더 많은 연구가 필요하다. 최근의 프로세서 온도 제어 연구의 초점은 부가적인 장치를 통해 프로세서 내에서 발생 된 온도를 제어하는 기계적인 냉각 기법에서 프로세서 내에서 발생하는 온도를 효과적으로 제어하여 프로세서의 신뢰성과 냉각 비용을 절감할 수 있는 구조적 설계 기법으로 이동하고 있다. 본 논문에서는 연구의 초점이 이동하는 원인에 대해 분석하고자 고성능 프로세서에서의 기계적 냉각 기법의 냉각 효율성을 분석하고자 한다. 실험 결과, 온도를 제어하는 데 있어서 매우 높은 비용($1^{\circ}C$ 감소 당 최대 3.58W, 평균 3.36W)이 소모되는 것으로 나타났다. 향후에는 구조적인 설계 기법의 냉각 효율성을 분석하는 실험을 진행하고자 한다.

  • PDF

Characteristics of a planar Bi-Sb multijunction thermal converter with Pt-heater (백금 히터가 내장된 평면형 Bi-Sb 다중접합 열전변환기의 특성)

  • Lee, H.C.;Kim, J.S.;Ham, S.H.;Lee, J.H.;Lee, J.H.;Park, S.I.;Kwon, S.W.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.154-162
    • /
    • 1998
  • A planar Bi-Sb multijunction thermal converter with high thermal sensitivity and small ac-dc transfer error has been fabricated by preparing the bifilar thin film Pt-heater and the hot junctions of thin film Bi-Sb thermopile on the $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$-diaphragm, which functions as a thermal isolation layer, and the cold junctions on the dielectric membrane supported with the Si-substrate, which acts as a heat sink, and its ac-dc transfer characteristics were investigated with the fast reversed dc method. The respective thermal sensitivities of the converter with single bifilar heater were about 10.1 mV/mW and 14.8 mV/mW in the air and vacuum, and those of the converter with dual bifilar heater were about 5.1 mV/mW and 7.6 mV/mW, and about 5.3 mV/mW and 7.8 mV/mW in the air and vacuum for the inputs of inside and outside heaters, indicating that the thermal sensitivities in the vacuum, where there is rarely thermal loss caused by gas, are higher than those in the air. The ac-dc voltage and current transfer difference ranges of the converter with single bifilar heater were about ${\pm}1.80\;ppm$ and ${\pm}0.58\;ppm$, and those of the converter with dual bifilar heater were about ${\pm}0.63\;ppm$ and ${\pm}0.25\;ppm$, and about ${\pm}0.53\;ppm$ and ${\pm}0.27\;ppm$, respectively, for the inputs of inside and outside heaters, in the frequency range below 10 kHz and in the air.

  • PDF

Design of Optical System for LED Lamp using MR16 (MR16용 LED 램프 조명설계)

  • Kim, Jun-Hyun;Moon, Byung-Kwon;Ryu, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4725-4732
    • /
    • 2012
  • This paper studies MR16 that can strengthen the strength and make up for the weakness of MR16 by replacing halogen light source using multifaceted Reflector(MR16) with LED light source. To achieve this, developed MR16 for LED applying optical system that four aspheric lens is one sheet. Optical system is designed by optics software and lighting performance of the designed data is predicted lighting simulation program. Also, heatsink's heat radiation analysis program to predict the thermal performance. Finally, optical prototype system based on simulation analysis data is manufactured and the results comparing performance of the developed system and the designed data are follows: Radiation angle was around $50^{\circ}{\sim}60^{\circ}$ in results of simulation analysis and the test of the prototype system. Also, temperature measurement result indicates that the thermal equilibrium is realized after one minute and thirty seconds and heat is generated up $60^{\circ}C$ in all of simulation analysis and the test of the prototype system. Finally, simulation analysis result on light disturbance curve of MR16 is similar to that of performance of the prototype system.