• 제목/요약/키워드: 방어시스템

Search Result 696, Processing Time 0.023 seconds

Expressional Analysis of Superoxide Dismutase in Olive Flounder (Paralichthys olivaceus) against Viral Hemorrhagic Septicemia Virus Infection (Viral hemorrhagic septicemia virus (VHSV) 감염에 대한 넙치 superoxide dismutase(Of-SOD)의 발현분석)

  • Lee, Young Mee;Kim, Jung-Eun;Noh, Jae Koo;Kim, Hyun Chul;Park, Choul-Ji;Park, Jong-Won;Kim, Kyung-Kil;Lee, Jeong-Ho
    • Journal of Life Science
    • /
    • v.24 no.12
    • /
    • pp.1371-1377
    • /
    • 2014
  • Superoxide dismutase is a family of important antioxidant metalloenzymes and catalyzes the dismutation of toxic superoxide anions into dioxygen and hydrogen peroxide. A recent study identified the partial superoxide dismutase (SOD) gene in olive flounder (Paralichthys olivaceus). The same study reported that it strongly induced benzo[a]pyrene and that it was an indicator of aquatic oxidative stress responses. However, its transcriptional response against viral infection has not been investigated. In the present study, the spatial and temporal expression profiles were analyzed to investigate the function of Of-SOD in the antiviral response. The Of-SOD transcripts were ubiquitously detected at various levels in diverse tissues in a real-time PCR. The expression of Of-SOD was significantly higher in the muscles, liver, and brain but extremely low in the stomach and spleen. Following a VHSV challenge, the expression of Of-SOD increased within 3 h in the kidneys and decreased to the original level 2 days postchallenge. In muscle, liver, and brain, Of-SOD mRNA was similarly up-regulated at 3-6 h postchallenge and then decreased to the basal level. Although the expression pattern and induction time differed slightly depending on the tissue, the transcript of Of-SOD consistently increased in the acute infection response, but the expression was low in the chronic response. The expression of Of-SOD was induced after the VHSV infection, and Of-SOD was probably involved in the immune response against the viral challenge. These results suggest that SOD may play important roles in the immune defense system of P. olivaceus and perhaps contribute to the protective effects against oxidative stress in olive flounder.

A Survey on Radiation Exposure of Patient in Mammography (유방 X선촬영 시 피폭선량에 대한 조사 연구)

  • Kim, Hyung-Chul;Cho, Pyung-Gon;Kim, Sung-Soo;Choi, Jong-Hak;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.55-60
    • /
    • 2004
  • The purpose of this study was to examine both patient exposure dose during mammography and the utility status of mammograpy equipments. The data of this study were collected through questionnaire survey for 278 medical facilities registered at Korean Hospital Association and finally 161 medical facilities's data were analyzed. According to data analysis, medical facilities of 14.9% used the average glandular dose of less than 0.5 mGy, $0.51{\sim}1.0\;mGy$ 8.6%, $1.01{\sim}1.5\;mGy$ 14.9%, $1.51{\sim}2.0\;mGy$ 11.1%, $2.01{\sim}2.5\;mGy$ 9.8%, $2.51{\sim}3.0\;mGy$ 33.3%, and 7.4% more than 3.01 mGy. It was found that medical facilities of 92.6% used less than 3 mGy, showing that this figure is similar to the limit value of 3 mGy recommended by Korea Food & Drug Administration(KFDA). Recently, international organizations such as ICRP associated with radiation protection suggests that less than 3 mGy of average mammary gland dose be used during mammography in case of using Mo target+Mo filter, film/screen system and craniocaudal projection with the breast pressed to 4.2 cm. The standard dose is being strictly observed and that of the limits is going down to 2 mGy or 1.5 mGy. The major results of this study indicate that interests and a counterplan to reduce patient dose during mammography should be considered. Based on this study, the authors of this study will continue to measure exposure dose to set a new standard for patient exposure dose during mammography.

  • PDF

A Study on the Dose Assessment Methodology Using the Probabilistic Characteristics of TL Element Response (확률분포 특성을 이용한 열형광선량계의 선량평가방법에 관한 연구)

  • Cho, Dae-Hyung;Oh, Jang-Jin;Han, Seung-Jae;Na, Seong-Ho;Hwang, Won-Guk;Lee, Won-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.123-138
    • /
    • 1998
  • Characteristics of element responses of Panasonic UD802 personnel dosimeters in the X, ${\beta}$, ${\gamma}$, ${\gamma}/X$, ${\gamma}/{\beta}$ and ${\gamma}$/neutron mixed fields were assessed. A dose-response algorithm has been developed to decide the high probability of a radiation type and energy by using the distribution in all six ratios of the multi-element TLD. To calculate the 4-element response factors and ratios between the elements of the Panasonic TLDs in the X, $\beta$, and $\gamma$ radiation fields, Panasonic’s UD802 TLDs were irradiated with KINS’s reference irradiation facility. In the photon radiation field, this study confirms that element-3 (E3) and element-4 (E4) of the Panasonic TLDs show energy dependent both in low- and intermediate-energy range, while element-1 (E1) and element-2 (E2) show little energy dependency in the entire whole range. The algorithm, which was developed in this study, was applied to the Panasonic personnel dosimetry system with UD716AGL reader and UD802 TLDs. Performance tests of the algorithm developed was conducted according to the standards and criteria recommended in the ANSI N13.11. The sum of biases and standard deviations was less than 0.232. The values of biases and standard deviations are distributed within a triangle of a lateral value of 0.3 in the ordinate and abscissa, With the above algorithm, Panasonic TLDs satisfactorily perform optimum dose assessment even under an abnormal response of the TLD elements to the energy imparted. This algorithm can be applied to a more rigorous dose assessment by distinguishing an unexpected dose from the planned dose for the most practical purposes, and is useful in conducting an effective personnel dose control program.

  • PDF

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

Bladder Volume Variations in Patients Receiving Conformal Radiotherapy to Prostate (전립선암 환자의 방사선 치료 시 방광 체적 변화)

  • Lee, Re-Na;Lee, Ji-Hye;Lee, Kyung-Ja;Ji, Young-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.61-65
    • /
    • 2008
  • Objective: To reduce urinary side effects in prostate cancer patients receiving radiation, patients were asked to drink certain amount of water to maintain bladder volume constant and the bladder volumes were measured weekly using ultrasound scanner. Materials and Methods: Twenty-six patients with prostate cancer who received radiation between December 2002 and August 2007 were enrolled in this study. Thirteen patients were enrolled in experimental group. These patients were asked to drink 450 cc of water, one hour prior to simulation, CT scan, and treatment. The other thirteen patients were given no information about bladder filing. Bladder, prostate, and rectum were contoured on CT and volumes were calculated. 3D conformal treatment planning was performed and effective volumes of bladder were calculated when a prescription dose of 70.2 Gy was delivered. For the patients in experimental group, bladder volumes were measured weekly using ultrasound scanner for 6-8 weeks and the bladder volume variations were analyzed. Results: Average bladder volumes and standard deviations obtained at CT scanning were $283.5{\pm}114.0\;cc$ (40%) and $181.2{\pm}120.1\;cc$ (66%) in experimental and control groups, respectively. Although it was not statistically significant, there was correlation between the bladder volumes measured from CT and ultrasound. The volumes measured using ultrasound scanner were 62% lower than the volumes using CT images on average. There was significant variations in volumes measured weekly for 6-8 weeks. It ranged between 33 - 75 %. Conclusion: Our results showed that it is possible to obtain larger bladder volume if they are asked to drink certain amount of water prior to CT scan. However, patients were unable to maintain constant bladder volumes over the 6-8 weeks of treatment period although they were asked to drink constant amount of water.

A Study of Masterplot of Disaster Narrative between Korea, the US and Japan (한·미·일 재난 서사의 마스터플롯 비교 연구)

  • Park, In-Seong
    • Journal of Popular Narrative
    • /
    • v.26 no.2
    • /
    • pp.39-85
    • /
    • 2020
  • This paper examines the aspects of disaster narrative, which makes the most of the concept of 'masterplot' as a narrative simulation to solve problems. By analyzing and comparing the remnants of 'masterplots' operating in the disaster narratives of Korea, the United States, and Japan, the differences between each country and social community problem recognition and resolution will be discussed. Disaster narrative is the most suitable genre for applying the 'masterplot' toward community problem solving in today's global risk society, and the problem-solving method has cognitive differences for each community. First, in the case of American disaster narratives, civilian experts' response to natural disasters tracks the changes of heroes in today's 'Marvel Comic Universe' (MCU). Compared to the past, the close relationship between heroism and nationalism has been reduced, but the state remains functional even if it is bolstered by the heroes' voluntary cooperation and reflection ability. On the other hand, in Korea's disaster narratives, the disappearance of the country and paralysis of the function are foregrounded. In order to fill the void, a new family narrative occurs, consisting of a righteous army or people abandoned by the state. Korea's disaster narratives are sensitive to changes after the disaster, and the nation's recovery never returns to normal after the disaster. Finally, Japan's disaster narratives are defensive and neurotic. A fully state-led bureaucratic system depicts an obsessive nationalism that seeks to control all disasters, or even counteracts anti-heroic individuals who reject voluntary sacrifices and even abandon disaster conditions This paper was able to diagnose the impact and value of a 'masterplot' today by comparing a series of 'masterplots' and their variations and uses. In a time when the understanding and utilization of 'masterplots' are becoming more and more important in today's world where Over-the top(OTT) services are being provided worldwide, this paper attempt could be a fragmentary model for the distribution and sharing of global stories.