• Title/Summary/Keyword: 방수분포

Search Result 27, Processing Time 0.024 seconds

Application of a Distributed Model for Evaluating the Effect of Sacheonman Spillway on the Flood Reduction in the Downstream of Namgang Dam (사천만 방수로가 남강댐 하류의 홍수량 저감에 미치는 영향 평가를 위한 분포형 모형의 적용)

  • Choi, Cheon Kyu;Choi, Yun Seok;Kim, Kyung Tak
    • Journal of Wetlands Research
    • /
    • v.14 no.3
    • /
    • pp.399-411
    • /
    • 2012
  • Namgang Dam is located in the upstream of Nam river. Namgang Dam controls flood for the downstream of Namgang Dam using the Namgang spillway and the Sacheonman spillway with planned discharge. However, it had not been evaluated adequately that the effect of the discharge through Sacheonman spillway on the flood reduction of the downstream of Namgang Dam. This study performs runoff simulation considering the discharge from Namgang Dam and Sacheonman spillway. And modeling results are evaluated for the flood reduction effect of Sacheonman spillway on the downstream of Namgang Dam. This study uses a distributed model, GRM(Grid based Rainfall-runoff Model) for runoff analysis. As a result, Sacheonman spillway is assigned more discharge than Namgang Dam, and Sacheonman spillway greatly affects flood reduction in the downstream of Namgang Dam.

Experimental study on the spray density distribution of water spray system in road tunnel (터널 물분무소화설비의 살수밀도분포에 대한 실험연구)

  • So, Soo-Hyun;Park, Kyung-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • Spray density of the water spray system which is installed in long road tunnels and hazardous vehicle tunnels is applied without proper performance assessment process. In this study, the requirements of Spray Density Guidelines at the standard pressure is investigated through spray test set up the nozzle of a water spray system in a simulated road tunnel. The results showed that all the nozzles used in the test area did not meet the requirements of the Guidelines. The absence of performance test codes and inspection process on the nozzle at real scale in tunnels may have caused this practice. Therefore, it is suggested that the performance test regulations of the nozzle on the water spray system is established in order to properly assess the system performance.

Analysis of Tide and Tidal Current in Namhae Coastal Waters (남해 주변해역의 조석과 조류분포 해석)

  • Kim, Cha Kyum
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.425-428
    • /
    • 2019
  • 본 연구에서는 남해 주변해역의 조석과 조류의 구조특성을 해석하기 위해 현장관측결과와 수치실험결과를 이용하였다. 남해 주변해역의 해수유동은 2003년~2008년 사이 노량수로, 대방수로, 여수수로, 창선수로, 강진만, 앵강만에서 ADCP 및 RCM 9 유속계를 사용하여 각 정점에서 1개월 정도 연속측류를 하였다. 노량수로와 대방수로에서는 ADCP를 사용하여 표층에서 저층까지 3m 간격으로 측류하였고, 여수수로, 창선수로, 강진만과 앵강만에서는 RCM-9 유속계를 사용하여 표층에서 연속 측류하였다. 노량수로 상층에서 동-서 방향의 최대 유속은 약 165~175 cm/sec, 대방수로에서는 창 낙조류 최대유속은 약 200~270 cm/sec, 여수수로에서는 약 85~96 cm/sec 정도 나타났다. 강진만의 표층에서 최대유속의 크기는 창 낙조류 비슷하게 35~46 cm/sec, 앵강만 입구 부근에서 낙 창조류 최대유속은 20~22 cm/sec으로 발생하였다. 또한, 조류수치모형실험을 수행하여 남해 주변해역의 조류분포 특성을 전반적으로 해석하였다.

  • PDF

Directional Water Spray Characteristics of Sprinkler Heads (스프링클러 헤드의 방향성 살수 특성 비교 연구)

  • Park Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.35-41
    • /
    • 2004
  • The water spray characteristics of the sprinkler heads is a very important factor affecting the fire suppression performance, and it is largely dependent on the shape of the head nozzle. This study investigated shape factors and spray distribution performances for the sprinkler heads of four domestic companies with big market shares. The experimental results revealed that all flow constants exceeded the required regulation limits, however showed big differences between head types although they have the same design limit. They were however relatively consistent regardless of the pressure increases. The spray distribution of some head samples showed severe directional eccentricity, which suggests more study for the improvement.

A Study about Introductory Plan of Automatic Wet Pipe Sprinkler System to Hydraulically Designed System (습식 스프링클러설비의 수리계산방식 도입방안에 관한 연구)

  • Park, Bong-Rae;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.69-77
    • /
    • 2007
  • Our country automatic wet pipe sprinkler system of hydraulically designed system has not deviated from the pipe regulation process, therefore we face limitations when using an independent method to hydraulically designed system. Therefore. after reviewing a developed country's methods using the drainage-density concept, we found it necessary for our country to introduce the drainage-density concept. Currently, under the National Fire Safety Codes(NFSC), this does not solve the problem and the limitation of hydraulically designed system because different problems arise depending on where the head was installed. To make improvements, first, such as the developed country, overcome the difference by introducing the drainage-density concept to determine the amount of drainage. Second, by using diverse head caliber and decreasing the limits on the amounts of distribution, we can expect a leveling off of the drainage density. Third, using the increase of hydraulically designed system through the application of the rule to hydraulically designed system, finally, development to performance based fire protection design.

Influence of Dam Water Discharge on the Oceanography and Fishery (해황과 어황에 미치는 댐 방수의 방향)

  • Chang Sun-duck
    • 한국해양학회지
    • /
    • v.1
    • /
    • pp.49-55
    • /
    • 1971
  • After the heavy precipitation from April 1969 to September 1970, more than 1.359 10$\^$6/㎥ of fresh water was discharged through diversion channel of the Namgang Dam. The sands and muds in the northern Sachon Bay were moved and swept away by the strong southsard flow which was observed to be speedier than five knots. The shellfish culture facility as well as the oysters and bivalves were buried. In Sachon Bay, a southward surface ebb current of approximately one knot stratifies above the northward flow of approximately 0.5 knot, which seems to be similar to the salt wedge estuary. The stratified current is responsible for the breaking of the gill nets and other fishing gears. The salinity of sea water in Chinju Bay decreased remarkably and the abnormal low salinity water lower than 5 was distributed in Sachon Bay. The low salinity water front was observed in eastern Chinju Bay and the Samchonpo Channel, where the salinity was increased from 4.6 to approximately 30 within half a tidal cycle. These caused the oysters and bivalves die, and drove anchovies and octopus out to the sea and prevented them from approaching the bay. The decrease of salinity causes the decrease of density and osmotic pressure of sea water. Turbid water would prevent the sunlight from penetrate into deep layer.

  • PDF

Hydraulic Experiment on the Underwater Outflow Structure for Reducing Bubble in the Drain Waterway of Thermal Power Plants (화력발전소 방수로에서의 거품저감을 위한 수중방류구조에 대한 수리모형실험)

  • Oh, Sang-Ho;Oh, Young-Min;Kang, Keum-Seok;Kim, Ji-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.539-543
    • /
    • 2008
  • 이 연구에서는 보령화력발전소 방수로 수중방류구조에 대한 수리모형실험을 수행하여 수중방류구조 내 흐름 양상을 고찰하고, 수평 유공판의 거품저감 효과를 검토하였다. 수중방류구조 내 유속은 설계시 거품의 부상 및 외해 유출 방지를 위해 고려한 목표값 1 m/s 이내에 분포하였다. 또한, 2차 낙하 위치에 수평 유공판을 설치함에 따라 거품 발생량이 크게 감소함을 확인하였다. 그러나, 수평 유공판 설치에 따라서 평균유속은 거의 변화가 없었으며, 다만 외해 조위가 운전정지수위에 해당할 경우에는 수평 유공판 아래에서 연직방향 흐름의 세기가 감소하였다.

  • PDF

Waterproofing Material Evaluation Method based on Stress Dispersion Analysis due to Displacement in Railway Bridges (철도교량에 거동발생 시 응력분포 분석에 따른 적정 방수재료 선정을 위한 평가 방법)

  • Oh, Kyu-Hwan;An, Ki-Won;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.59-60
    • /
    • 2021
  • To measure the effect of the stress-strain dispersion across the installed waterproofing layer on the concrete surface, a strain gauge was attached to the gap between the waterproofing layer and the concrete structure at specified points of upper, center and bottom of the load-displacement simulation specimen, and the peak stress-strain at the displacement interface were measured and compared with stress-strain at other areas to analyze each material types' stress-strain dispersion ratio properties. Based on the results of the testing, it was shown that materials with high load-displacement resistance performance accordingly had high stress-strain dispersion ratio results, and the materials from highest performance to lowest performance were; CAS, SAS, PUC and CSC.

  • PDF

A Research on Suggestion of Performance Grade for each Assessment Items of Self-Adhesive Waterproofing Sheet (자착식형 방수 시트의 평가 항목별 성능등급 제안에 관한 연구)

  • Park, Wan-Goo;An, Ki-Won;Heo, Neung-Hoe;Kim, Yun-Ho;Park, Jin-Samg;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.23-25
    • /
    • 2012
  • Because Self-Adhesive Waterproofing sheet has good constructability, it has been widely used. Also Self-Adhesive Waterproofing sheet is researched based on variety of materials and various of forms. However, producers have recognized about only pass KS quality standard. So, Self-Adhesive waterproofing sheet has been limited about improvement of performance. Therefore, in this research, proposed guideline of Self-Adhesive Waterproofing sheet for disinterested performance grade using probability theory and quality management theory.

  • PDF

Analysis of Water Penetration through Pores in Spray-applied Waterproofing Membrane Using X-ray CT Images (X-ray CT를 이용한 분무식 방수 멤브레인의 공극 내 물 침투 분석)

  • Choi, Soon-Wook;Kang, Tae-Ho;Chang, Soo-Ho;Lee, Chulho;Choi, Myung-Sik;Kim, Kwang Yeom
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.211-219
    • /
    • 2017
  • The spray-applied waterproofing membrane is installed on shotcrete or concrete surface to make impermeable layer with 3-5 mm thick for the purpose of waterproofing. This study aims to determine the internal structure of a spray-applied waterproofing membrane including pores by using X-ray CT technique. Before obtaining X-ray images of the membrane specimens, a waterproof performance test was performed on the membrane specimens with a water pressure of 500 kPa for 28 days. Results show that the movement of moisture is made through micropores. This is based on the fact that the large pores inside the membrane are not saturated and the degrees of saturation of the micropores are high. X-ray image is effective for determining the pore size distribution and whether the membrane with pores contains the water However, it is necessary to pay attention to the determination of water content, since water content may vary depending on the threshold value of X-ray image analysis applied to calculate the water content.