• Title/Summary/Keyword: 방사화계산

Search Result 148, Processing Time 0.029 seconds

Construction of a Standard Dataset for Liver Tumors for Testing the Performance and Safety of Artificial Intelligence-Based Clinical Decision Support Systems (인공지능 기반 임상의학 결정 지원 시스템 의료기기의 성능 및 안전성 검증을 위한 간 종양 표준 데이터셋 구축)

  • Seung-seob Kim;Dong Ho Lee;Min Woo Lee;So Yeon Kim;Jaeseung Shin;Jin‑Young Choi;Byoung Wook Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1196-1206
    • /
    • 2021
  • Purpose To construct a standard dataset of contrast-enhanced CT images of liver tumors to test the performance and safety of artificial intelligence (AI)-based algorithms for clinical decision support systems (CDSSs). Materials and Methods A consensus group of medical experts in gastrointestinal radiology from four national tertiary institutions discussed the conditions to be included in a standard dataset. Seventy-five cases of hepatocellular carcinoma, 75 cases of metastasis, and 30-50 cases of benign lesions were retrieved from each institution, and the final dataset consisted of 300 cases of hepatocellular carcinoma, 300 cases of metastasis, and 183 cases of benign lesions. Only pathologically confirmed cases of hepatocellular carcinomas and metastases were enrolled. The medical experts retrieved the medical records of the patients and manually labeled the CT images. The CT images were saved as Digital Imaging and Communications in Medicine (DICOM) files. Results The medical experts in gastrointestinal radiology constructed the standard dataset of contrast-enhanced CT images for 783 cases of liver tumors. The performance and safety of the AI algorithm can be evaluated by calculating the sensitivity and specificity for detecting and characterizing the lesions. Conclusion The constructed standard dataset can be utilized for evaluating the machine-learning-based AI algorithm for CDSS.

Release Characteristics of Fission Gases with Spent Fuel Burn-up during the Voloxidation and OREOX Processes (사용후핵연료의 연소도 변화에 따른 산화 및 OREOX 공정에서 핵분열기체 방출 특성)

  • Park, Geun-Il;Cho, Kwang-Hun;Lee, Jung-Won;Park, Jang-Jin;Yang, Myung-Seung;Song, Kee-Chan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.39-52
    • /
    • 2007
  • Quantitative analysis on release behavior of the $^{85}Kr\;and\;^{14}C$ fission gases from the spent fuel material during the voloxidation and OREOX process has been performed. This thermal treatment step in a remote fabrication process to fabricate the dry-processed fuel from spent fuel has been used to obtain a fine powder The fractional release percent of fission gases from spent fuel materials with burn-up ranges from 27,000 MWd/tU to 65,000 MWd/tU have been evaluated by comparing the measured data with these initial inventories calculated by ORIGEN code. The release characteristics of $^{85}Kr\;and\;^{14}C$ fission gases during the voloxidation process at $500^{\circ}C$ seem to be closely linked to the degree of conversion efficiency of $UO_2\;to\;U_3O_8$ powder, and it is thus interpreted that the release from grain-boundary would be dominated during this step. The high release fraction of the fission gas from an oxidized powder during the OREOX process would be due to increase both in the gas diffusion at a temperature of $500^{\circ}C$ in a reduction step and in U atom mobility by the reduction. Therefore, it is believed that the fission gases release inventories in the OREOX step come from the inter-grain and inter-grain on $UO_2$ matrix. It is shown that the release fraction of $^{85}Kr\;and\;^{14}C$ fission gases during the voloxidation step would be increased as fuel burn-up increases, ranging from 6 to 12%, and a residual fission gas would completely be removed during the OREOX step. It seems that more effective treatment conditions for a removal of volatile fission gas are of powder formation by the oxidation in advance than the reduction of spent fuel at the higher temperature.

  • PDF

Multi-tracer Imaging of a Compton Camera (다중 추적자 영상을 위한 컴프턴 카메라)

  • Kim, Soo Mee
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.18-27
    • /
    • 2015
  • Since a Compton camera has high detection sensitivity due to electronic collimation and a good energy resolution, it is a potential imaging system for nuclear medicine. In this study, we investigated the feasibility of a Compton camera for multi-tracer imaging and proposed a rotating Compton camera to satisfy Orlov's condition for 3D imaging. Two software phantoms of 140 and 511 keV radiation sources were used for Monte-Carlo simulation and then the simulation data were reconstructed by listmode ordered subset expectation maximization to evaluate the capability of multi-tracer imaging in a Compton camera. And the Compton camera rotating around the object was proposed and tested with different rotation angle steps for improving the limited coverage of the fixed conventional Compton camera over the field-of-view in terms of histogram of angles in spherical coordinates. The simulation data showed the separate 140 and 511 keV images from simultaneous multi-tracer detection in both 2D and 3D imaging and the number of valid projection lines on the conical surfaces was inversely proportional to the decrease of rotation angle. Considering computation load and proper number of projection lines on the conical surface, the rotation angle of 30 degree was sufficient for 3D imaging of the Compton camera in terms of 26 min of computation time and 5 million of detected event number and the increased detection time can be solved with multiple Compton camera system. The Compton camera proposed in this study can be effective system for multi-tracer imaging and is a potential system for development of various disease diagnosis and therapy approaches.

The Effect of Crystallization by Heat Treatment on Electromagnetic Interference Shielding Efficiency of Carbon Fibers (열처리 온도에 의한 구조 결정성이 탄소섬유의 전자파 차폐 성능에 미치는 영향)

  • Kim, Jong Gu;Chung, Choul Ho;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.22 no.2
    • /
    • pp.138-143
    • /
    • 2011
  • To investigate the electromagnetic interference shielding efficiency (EMI SE) property based on heat treatment effects of carbon fibers in various temperatures, the polyacrilonitrle-based carbon fibers were prepared by electrospinning method and treated at 1073, 1323, 1873 and 2573 K. The surface morphology of carbon fibers was investigated by using FE-SEM and the carbon crystallization was studied by Raman spectroscopy based on effects of reaction temperatures. The electrical conductivity was obtained by measuring the surface resistance with four probe method on carbon crystallization. The permittivity, permeability and EMI SE were investigated by using S-parameter in the range of 800~4500 MHz. In case of carbon fibers treated at 2573 K, the improved carbon crystallization was confirmed by Raman spectrum and the enhanced electrical conductivity showing 54.7 S/cm was also observed. The permittivity was dramatically improved by factor of 4 based on effect of high reaction temperature. Eventually, the highly improved EMI SE value was obtained showing around 41.7 dB.

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

Rear Vehicle Detection Method in Harsh Environment Using Improved Image Information (개선된 영상 정보를 이용한 가혹한 환경에서의 후방 차량 감지 방법)

  • Jeong, Jin-Seong;Kim, Hyun-Tae;Jang, Young-Min;Cho, Sang-Bok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.1
    • /
    • pp.96-110
    • /
    • 2017
  • Most of vehicle detection studies using the existing general lens or wide-angle lens have a blind spot in the rear detection situation, the image is vulnerable to noise and a variety of external environments. In this paper, we propose a method that is detection in harsh external environment with noise, blind spots, etc. First, using a fish-eye lens will help minimize blind spots compared to the wide-angle lens. When angle of the lens is growing because nonlinear radial distortion also increase, calibration was used after initializing and optimizing the distortion constant in order to ensure accuracy. In addition, the original image was analyzed along with calibration to remove fog and calibrate brightness and thereby enable detection even when visibility is obstructed due to light and dark adaptations from foggy situations or sudden changes in illumination. Fog removal generally takes a considerably significant amount of time to calculate. Thus in order to reduce the calculation time, remove the fog used the major fog removal algorithm Dark Channel Prior. While Gamma Correction was used to calibrate brightness, a brightness and contrast evaluation was conducted on the image in order to determine the Gamma Value needed for correction. The evaluation used only a part instead of the entirety of the image in order to reduce the time allotted to calculation. When the brightness and contrast values were calculated, those values were used to decided Gamma value and to correct the entire image. The brightness correction and fog removal were processed in parallel, and the images were registered as a single image to minimize the calculation time needed for all the processes. Then the feature extraction method HOG was used to detect the vehicle in the corrected image. As a result, it took 0.064 seconds per frame to detect the vehicle using image correction as proposed herein, which showed a 7.5% improvement in detection rate compared to the existing vehicle detection method.

Multiple Linear Analysis for Generating Parametric Images of Irreversible Radiotracer (비가역 방사성추적자 파라메터 영상을 위한 다중선형분석법)

  • Kim, Su-Jin;Lee, Jae-Sung;Lee, Won-Woo;Kim, Yu-Kyeong;Jang, Sung-June;Son, Kyu-Ri;Kim, Hyo-Cheol;Chung, Jin-Wook;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.317-325
    • /
    • 2007
  • Purpose: Biological parameters can be quantified using dynamic PET data with compartment modeling and Nonlinear Least Square (NLS) estimation. However, the generation of parametric images using the NLS is not appropriate because of the initial value problem and excessive computation time. In irreversible model, Patlak graphical analysis (PGA) has been commonly used as an alternative to the NLS method. In PGA, however, the start time ($t^*$, time where linear phase starts) has to be determined. In this study, we suggest a new Multiple Linear Analysis for irreversible radiotracer (MLAIR) to estimate fluoride bone influx rate (Ki). Methods: $[^{18}F]Fluoride$ dynamic PET scans was acquired for 60 min in three normal mini-pigs. The plasma input curve was derived using blood sampling from the femoral artery. Tissue time-activity curves were measured by drawing region of interests (ROls) on the femur head, vertebra, and muscle. Parametric images of Ki were generated using MLAIR and PGA methods. Result: In ROI analysis, estimated Ki values using MLAIR and PGA method was slightly higher than those of NLS, but the results of MLAIR and PGA were equivalent. Patlak slopes (Ki) were changed with different $t^*$ in low uptake region. Compared with PGA, the quality of parametric image was considerably improved using new method. Conclusion: The results showed that the MLAIR was efficient and robust method for the generation of Ki parametric image from $[^{18}F]Fluoride$ PET. It will be also a good alternative to PGA for the radiotracers with irreversible three compartment model.

Brain Regions Associated With Anhedonia in Healthy Adults : a PET Correlation Study (정상 성인에서 양전자방출단층촬영을 통해 관찰한 무쾌감증 관련 뇌 영역)

  • Jung, Young-Chul;Seok, Jeong-Ho;Chun, Ji-Won;Park, Hae-Jeong;Lee, Jong-Doo;Kim, Jae-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.438-444
    • /
    • 2005
  • Purpose: Anhedonia has been proposed to be the result of a basic neurophysiologic dysfunction and a vulnerability marker that precede and contribute to the liability of developing schizophrenia. We hypothesized that anhedonia, as a construct reflecting the decreased capacity to experience pleasure, should be associated with decreased positive hedonic affect trait. This study examined the relationship between anhedonia and positive hedonic affect trait and searched for the brain legions which correlate with anhedonia in normal subjects. Materials and Methods: Using $^{18}F$-FDG PET scan, we investigated the brain activity of twenty one subjects during resting state. Questionnaires were administrated after the scan in order to assess the self-rated individual differences in physical/social anhedonia and positive/negative affect traits. Results: Negative correlation between physical anhedonia score and positive affect trait score was significant (Pearson coefficient =-0.440, p<0.05). The subjects physical and social anhedonia scores showed positive correlation with metabolic rates in the cerebellum and negative correlation with metabolic rates in the inferior temporal gyrus and middie frontal gyrus. In addition, the positive affect trait score positively correlated with various areas, most prominent with the inferior temporal gyrus. Conclusion: These results suggest that neural substrates, such as the inferior temporal gyrus and prefrontal-cerebellar circuit, which dysfunction has been proposed to be involved with the cognitive deficits of schizophrenia, may also play a significant role in the liability of affective deficits like anhedonia.

Position Uncertainty due to Multi-scattering in the Scintillator Array of Dual Collimation Camera (복합 집속 카메라의 섬광체배열에서 다중산란에 의한 위치 불확실성)

  • Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.287-292
    • /
    • 2008
  • Position information of radiation interactions in detection material is essential to reconstruct a radiation source image. With most position sensing techniques, the position information of a single interaction inside the detectors can be precisely obtained. Each interaction position of multi-scattering inside scintillators, however, can not be individually measured and only the average of the scattering positions can be obtained, which causes the uncertainty in the measured interaction position. In this paper, the position uncertainties due to the multi-scattering were calculated by Monte Carlo simulation. The simulation model was a 50 by 50 by 5 mm $LaCl_3$(Ce) scintillator(pixel size is 2 by 2 by 5mm) which was utilized for the dual collimation camera. The dual collimation camera uses the information from both photoelectric effect and Compton scattering, and therefore, position uncertainties for both partial and full energy deposition of radiation interactions are calculated. In the case of partial energy deposition(PED), the standard deviations of positions are less than $1{\sim}2mm$, which means the uncertainty caused by multi-scattering is not significant. Because the effect of the multi-scattering with PED is insignificant, the multi-scattering has little effect on the performance of Compton imaging of dual collimation camera. In the case of full energy deposition(FED), however, the standard deviation of the positions is about twice that of the pixel size of the 1stdetector, except for 122keV incident radiations. Therefore, the standard deviations caused by multi-scatterings should be considered in the design of the coded mask of the dual collimation camera to avoid artifact on the reconstructed image. The position uncertainties of the FEDs are much larger than those of the PEDs for all radiation energies and the ratio of PEDs to FEDs increases when the incident radiation energy increases. The position uncertainties of both PEDs and FEDs are dependent on the incident radiation energy.

  • PDF

A Theoretical Study for Estimation of Oxygen Effect in Radiation Therapy (방사선 조사시 산소가 세포에 미치는 영향의 이론적 분석)

  • Rena J. Lee;HyunSuk Suh
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.157-165
    • /
    • 2000
  • Purpose: For estimation of yields of l)NA damages induced by radiation and enhanced by oxygen, a mathematical model was used and tested. Materials and Methods: Reactions of the products of water radiolysis were modeled as an ordinary time dependant equations. These reactions include formation of radicals, DNA damage, damage repair, restitution, and damage fixation by oxygen and H-radical. Several rate constants were obtained from literature while others were calculated by fitting an experimental data. Sensitivity studies were performed changing the chemical rate constant at a constant oxygen number density and varying the oxygen concentration. The effects of oxygen concentration as well as the damage fixation mechanism by oxygen were investigated. Oxygen enhancement ratio(OER) was calculated to compare the simulated data with experimental data. Results: Sensitivity studies with oxygen showed that DNA survival was a function of both oxygen concentration and the magnitude of chemical rate constants. There were no change in survival fraction as a function of dose while the oxygen concentration change from 0 to 1.0 x 10$^{7}$ . When the oxygen concentration change from 1.0 $\times$ 107 to 1.0 $\times$ 101o, there was significant decrease in cell survival. The OER values obtained from the simulation study were 2.32 at 10% cell survival level and 1.9 at 45% cell survival level. Conclusion: Sensitivity studies with oxygen demonstrated that the experimental data were reproduced with the effects being enhanced for the cases where the oxygen rate constants are largest and the oxygen concentration is increased. OER values obtained from the simulation study showed good agreement for a low level of cell survival. This indicated that the use of the semi-empirical model could predict the effect of oxygen in cell killing.

  • PDF