• Title/Summary/Keyword: 방사선 피폭관리

Search Result 238, Processing Time 0.03 seconds

Comparison of the Measured Radiation Dose-rate by the Ionization Chamber and GM(Geiger-Müller) Counter After Radioactive Iodine Therapy in Differentiated Thyroid Cancer Patients (분화성 갑상선암환자의 방사성 요오드 치료시 전리함과 Geiger-Muller계수관에서 방사선량률 측정값 비교)

  • Park, Kwang-hun;Kim, Kgu-hwan
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.565-570
    • /
    • 2016
  • Radioactive iodine($^{131}I$) treatment reduces recurrence and increases survival in patients with differentiated thyroid cancer. However, it is important in terms of radiation safety management to measure the radiation dose rate generated from the patient because the radiation emitted from the patient may cause the exposure. Research methods, it measured radiation dose-rate according to the elapsed time from 1 m from the upper abdomen of the patient by intake of radioactive iodine. Directly comparing the changes over time, high dose rate sensitivity and efficiency is statistically significant, and higher chamber than GM counter(p<0.05). Low dose rate sensitivity and efficiency in the chamber had lower levels than gm counter, but not statistically significant(p>0.05). In this study confirmed the characteristics of calibrated ionization chamber and GM counter according to the radiation intensity during high-dose radioactive iodine therapy by measuring the accurate and rapid radiation dose rate to the patient explains, discharged patients will be reduced to worry about radiation hazard of family and others person.

Testing and Analysis of Tube Voltage and Tube Current in The Radiation Generator for Mammography (유방촬영용 방사선발생장치의 관전압과 관전류 시험 분석)

  • Jung, Hong-Ryang;Hong, Dong-Hee;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant, manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration "about the safety of diagnostic radiation generator rule" specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

A Study on Regulations Through Analysis of the Status of Radiation Workers and Related Workers and Satisfaction Survey in the Radiology Department (방사선작업종사자 및 방사선관계종사자의 현황 분석과 교내 실습 만족도 조사를 통한 방사선(학)과의 규제에 대한 고찰)

  • Jung, Hyunseo;Lee, Yong-Ki;Ahn, Sung-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.327-334
    • /
    • 2022
  • In this study, the purpose of this study was to conduct a basic study on the effectiveness and feasibility of the regulation of the Nuclear Safety Act for the department of radiology by examining the questionnaire on the satisfaction of on-campus practice while attending the department of radiology and the current status of radiation workers and radiation related workers. As for the satisfaction of the workers who were designated as frequent visitors while attending the department of radiology and did not handle and operate the radiation generator during on-campus training, 34.62% of the workers answered 'not satisfied'. On the other hand, 50% of workers who were designated as radiation workers while attending school or who were enrolled in school before the regulation of the nuclear safety act and handled and operated radiation generators were 'satisfied' at 50%. In addition, the annual exposure dose of radiation workers in educational institutions was found to be less than 0.05 mSv. If you look at the trends of radiation workers and radiation workers, it can be seen that students who graduate from the Department of Radiology find the most employment in the field dealing with diagnostic radiation generators registered as radiation workers among medical institutions. Therefore, by easing the regulations of the current Nuclear Safety Act or by amending the medical act and the rules on the safety management of diagnostic radiation generating devices, etc. It is presumed that something is necessary.

A Study on the Dose Assessment Methodology Using the Probabilistic Characteristics of TL Element Response (확률분포 특성을 이용한 열형광선량계의 선량평가방법에 관한 연구)

  • Cho, Dae-Hyung;Oh, Jang-Jin;Han, Seung-Jae;Na, Seong-Ho;Hwang, Won-Guk;Lee, Won-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.123-138
    • /
    • 1998
  • Characteristics of element responses of Panasonic UD802 personnel dosimeters in the X, ${\beta}$, ${\gamma}$, ${\gamma}/X$, ${\gamma}/{\beta}$ and ${\gamma}$/neutron mixed fields were assessed. A dose-response algorithm has been developed to decide the high probability of a radiation type and energy by using the distribution in all six ratios of the multi-element TLD. To calculate the 4-element response factors and ratios between the elements of the Panasonic TLDs in the X, $\beta$, and $\gamma$ radiation fields, Panasonic’s UD802 TLDs were irradiated with KINS’s reference irradiation facility. In the photon radiation field, this study confirms that element-3 (E3) and element-4 (E4) of the Panasonic TLDs show energy dependent both in low- and intermediate-energy range, while element-1 (E1) and element-2 (E2) show little energy dependency in the entire whole range. The algorithm, which was developed in this study, was applied to the Panasonic personnel dosimetry system with UD716AGL reader and UD802 TLDs. Performance tests of the algorithm developed was conducted according to the standards and criteria recommended in the ANSI N13.11. The sum of biases and standard deviations was less than 0.232. The values of biases and standard deviations are distributed within a triangle of a lateral value of 0.3 in the ordinate and abscissa, With the above algorithm, Panasonic TLDs satisfactorily perform optimum dose assessment even under an abnormal response of the TLD elements to the energy imparted. This algorithm can be applied to a more rigorous dose assessment by distinguishing an unexpected dose from the planned dose for the most practical purposes, and is useful in conducting an effective personnel dose control program.

  • PDF

The BIDAS Program : Bioassay Data Analysis Software for Evaluating Radionuclide Intake and Dose (BIDAS프로그램 : 방사성 핵종의 섭취량과 선량 평가용 생물학적분석 자료 해석 소프트웨어 프로그램)

  • Tae-Yong Lee;Jong-Kyung Kim;Jong-Il Lee;Si-Young Chang
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.113-124
    • /
    • 2004
  • A computer software program, called BIDAS (BIoassay Data Analysis Software) is developed to interpret the bioassay measurement data in terms of intakes and the committed effective dose using the human respiratory tract model (HRTM), gastrointestinal tract (GI-tract) model and biokinetic models currently recommended by the International Commission on Radiological Protection (ICRP) to describe the behavior of the radioactive materials within the body. The program consists of three modules; first, a database module to manage the bioassay data, second, another databasee module to store the predicted bioassay quantities of each radionuclide and finally, a computational module to estimate the intake and committed effective dose calculated with the bioassay quantity measurement values from either an acute or chronic exposure of the radionuclies within the body. This paper describes the features of the program as well as the quality assurance check results of the BIDAS software program.

  • PDF

Evaluation of Area Dose Product and Image Density according to the Variable Tube Current (관전류 변화에 따른 면적선량과 영상 농도 평가)

  • Yun, YoungWoo;Je, Jaeyong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.645-650
    • /
    • 2018
  • This research aims at measuring images density of according to DAP(dose area product), and suggesting the need to quality control of exposure dose. When tube voltage was fixed as 80 kVp and tube current was set as 1, 25, 50, 80, and 100 mAs, with the increase of DAP from 25 mAs to 50 mAs, the dose also rose 1.88 times as much as before, and with the increase from 50 mAs to 100 mAs, it got 2.05 time higher than before. However, the images density obtained as film grew as much as 48% with the increase from 25 mAs to 50 mAs, and 29% with the increase from 50 mAs to 100 mAs. In addition, it has been found out that the higher the DR images density got from 25 mAs to 50 mAs, the bigger it became by 12%, and that it got bigger by 30% with the increase from 50 mAs to 100 mAs. In other words, the differences in the image density by the increase of the dose with the digital imaging equipment in a proper condition was proved to be less than in the film images. Based on the results of this research, medical institutions using a digital imaging equipment are expected to be able to reduce exposure dose of each region of interest than now through the quality control of radiation dose.

A Study on the Environmental Condition and Safety in Dental Radiographic Room (치과 방사선 촬영실의 촬영실태와 방사선 안전관리 실태에 관한 조사 연구)

  • Kang, Eun-Ju;Lee, Kyung-Hee;Ju, On-Ju
    • Journal of dental hygiene science
    • /
    • v.5 no.2
    • /
    • pp.83-88
    • /
    • 2005
  • In spite of relatively low level of radiation dose used at dental clinics, long term exposure may be harmful, so radiation workers at dental clinics must be well aware of its danger. This study was radiation safety management by dental hygienists in order to take preventive measures for dental hygienists and suggest ideas to develop radiation safety training programs. For this, we contacted dental hygienists working at the local dental clinics for 4 months from December of 2003 to march of 2004 and obtained the following findings. 1. Regarding the intraoral radiographic method, the average daily photographing frequency of standard films stood at one to five pieces (47.5%), and the average weekly photographing frequency of digital radiation medicine stood at less than one piece (69.8%), and the average weekly photographing frequency of bitewing films stood at less than one piece (67.7%), and and the average weekly photographing frequency of occlusal films stood at less than one piece (95.5%), and the dentistries whose average weekly photographing frequency of pediatric films stood at one to five pieces accounted for 47.1 percent. 2. Regarding the extraoral radiographic method, the average weekly photographing frequency of panorama film stood at one to five pieces (63.7%), and less than one piece (20.9%), the average weekly photographing frequency of cephalometric film stood at less than one piece (72.3%), and one to five pieces (20.1%). 3. Concerning the radiation safety management training program, only 18.7% of total 278 surveyed attended the training progra., Attendance tendency of the training program by general characteristics showed statistically significant difference according to age (p<0.01), working experience (p<0.001), and marital status (p<0.01). 4. When asked about the protective equipments against radiation exposure, 40.6% of them said "modest", and 71.1% appeared equipped with led apron as a protective tool.

  • PDF

A Case Study of Software Architecture Design by Applying the Quality Attribute-Driven Design Method (품질속성 기반 설계방법을 적용한 소프트웨어 아키텍처 설계 사례연구)

  • Suh, Yong-Suk;Hong, Seok-Boong;Kim, Hyeon-Soo
    • The KIPS Transactions:PartD
    • /
    • v.14D no.1 s.111
    • /
    • pp.121-130
    • /
    • 2007
  • in a software development, the design or architecture prior to implementing the software is essential for the success. This paper presents a case that we successfully designed a software architecture of radiation monitoring system (RMS) for HANARO research reactor currently operating in KAERI by applying the quality attribute-driven design method which is modified from the attribute-driven design (ADD) introduced by Bass[1]. The quality attribute-driven design method consists of following procedures: eliciting functionality and quality requirements of system as architecture drivers, selecting tactics to satisfy the drivers, determining architectures based on the tactics, and implementing and validating the architectures. The availability, maintainability, and interchangeability were elicited as duality requirements, hot-standby dual servers and weak-coupled modulization were selected as tactics, and client-server structure and object-oriented data processing structure were determined at architectures for the RMS. The architecture was implemented using Adroit which is a commercial off-the-shelf software tool and was validated based on performing the function-oriented testing. We found that the design method in this paper is an efficient method for a project which has constraints such as low budget and short period of development time. The architecture will be reused for the development of other RMS in KAERI. Further works are necessary to quantitatively evaluate the architecture.

Change of Dose Exposure and Improvement of Image Quality by Additional Filtration in Mammography (유방촬영용장치 부가필터에 따른 선량변화 및 화질개선)

  • Cho, Woo Il;Kim, Young Kuen;Lee, Gil Dong
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.78-90
    • /
    • 2013
  • Recently, the interest on exposure to radiation is rising. The radiation exposure of mammography is higher in absorbed dose than of X-ray, therefore unnecessary exposure needs to be reduced, and higher image quality is needed. Generally, ray quality of the radiation imaging is an important factor that determines image quality and the amount of ray exposure, and they are affected by tube voltage and added filter. The X-ray energy that is exposed from mammography device is generally a continuous spectrum, which includes low energy that has minute influence on the image quality, and high energy that hinders contrast on image. Currently, molybdenum (Mo) and rhodium (Rh) are the most used added filters for mammography device, and they are used differently according to the energy region of X-ray. This study aims to find out the degree of reduction in exposure dose according to the thickness of aluminum (Al), and to study the changes in image quality and dose when the added filter plates that are made with niobium (Nb) or zirconium (Zr) are used, other than molybdenum (Mo) and rhodium (Rh), the two most used added filters that have similar atomic number and K-absorption regions as Nb and Zr. In this study, single-added filters of molybdenum (Mo), niobium (Nb), and zirconium (Zr) are used, and in some cases, Aluminum (Al) is combined with the single filters. In this case, image quality is considered to be improved depending on the type of added filters, and by using Aluminum (Al) filter together with the others, unnecessary X-ray of low energy would be absorbed, therefore the dose is expected to decrease without any influence when the concentration level becomes identical.

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.