• Title/Summary/Keyword: 방사선 투과촬영

Search Result 85, Processing Time 0.024 seconds

Preliminary Study (1) for Development of Computed Radiography (CR) Image Analysis according to X-ray Non-destructive Test by Wood Species (Computed Radiograhpy (CR)를 통한 목재 수종별 X선 투과 이미지 해석을 위한 기초연구 (1))

  • Song, Jung Il;Kim, Han Seul
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.220-231
    • /
    • 2021
  • The use of digital copies of film-based analog images and the introduction of digital radiographic imaging systems using image plates gradually replace the non-destructive radiationirradiation method of Cultural Heritage. The quality of images obtained from this technique is affected by conditions such as tube voltage, tube current, and exposure time, type of image acquisition medium, distance of the artifacts from the image acquisition medium, and thickness of artifacts. In this study, we evaluated the grayscale image obtained using GE's Computed Radiograhpy (CR) imaging system, the transmission characteristics of the X-ray source for each tree type (pine, chestnut, sawtooth oak, ginkgo) used in wooden Cultural Heritage, and the signal-to-noise ratio (SNR) and contrast. The GE's CR imaging were analyzed using the Duplex wire image quality indicator, line-pair gauges.

Evaluation of Radiolucent Considering the Compression Paddle Materials in Mammography (유방촬영장치의 압박대 재질을 고려한 투과선량 평가)

  • Hong, Dong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.307-312
    • /
    • 2015
  • Mammography improves image quality that is on the increase day by day and get a picture with the pressure it is essential to reduce the dose. However, because due to the thickness of the cuff itself may increase the dose scattering lines is necessary study on the cuff material. Material that is currently being used in clinical Polycarbonate is a plastic and family. If you try to reduce the exposure of patients than itgie need to consider for the better material in this study to compare against a radiolucent line for amorphous plastic material of the plastic. results radiolucent and half layer, transmitting dose Pixel values HIPS, GPPS, ABS, Tritan, PC, PMMA showed high results in the net.

Deep Learning-based Automated Detection of Radio-Opaque Markers in X-Ray Images (딥러닝 기반 방사선 비투과성 표지자 자동 검출 기법)

  • Song, Youngmin;Lee, Byoung-Dai
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2017.06a
    • /
    • pp.40-43
    • /
    • 2017
  • 본 논문은 딥러닝을 이용하여 대장통과시간(Colon Transit Time, CTT) 검사를 위한 단순복부 X-Ray 영상에서 방사선 비투과성 표지자(Radio-opaque Marker)를 자동으로 검출하는 기법을 제시한다. 대장통과시간 검사는 대장의 운동질환을 평가하는데 있어 가장 기본적인 방법으로 특히 만성 변비증 환자의 병태생리에 따른 유형 분류와 치료 계획을 설정하는데 큰 도움을 주고 있으며, 내과적 또는 외과적 치료 후 평가에도 유용한 검사이다. 대장통과시간 검사는 방사선 비투과성 표지자가 내재되어 있는 캡슐을 복용한 뒤 주기적으로 단순복부 X-Ray 촬영을 통해 구간별로 남아있는 표지자의 수를 세고, 이를 통해 구역별 통과시간을 측정한다. 이 과정에서 판독의가 직접 표지자의 위치 및 개수를 세기 때문에 많은 시간이 필요하게 된다. 따라선 본 논문에서는 이러한 단점을 보완하기 위해 딥러닝 기법을 사용하여 X-Ray 영상 내에서 표지자의 위치를 자동 파악하는 기법을 제시한다.

  • PDF

TRAUMATIC BONE CYST : A CASE REPORT (외상성 골낭의 치험례)

  • Oh, Min-Hyung;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.18-25
    • /
    • 2005
  • Traumatic bone cyst is a nonodontogenic cyst without epithelial-linig which contains fluid in it's cavity, and it is limited by bone walls with no evidence of infection. Traumatic bone cyst is asymptomatic and appears more frequently in the second decade. Gender distribution is approximately equal, although males are affected slightly often than females. Radiographically the lesion shows a well demarcated radiolucent lesion of variable size and the lesion may have scalloped margins. The adjacent teeth to traumatic bone cyst remains vital. Traumatic bone cyst is usually treated by surgical exploration and currettage of the lesion. In the first case of this case report, the patient was refered from the local dental clinic for the radiolucent area under the left mandibular first molar. From the panorama radiograph at the first visit, the radiolucent area of the left mandible showed a well defined scalloped margin and identified as traumatic bone cyst. In the second case, the patient have visited for the chief complaint of swelling and abcess of right maxillary second premolar. In the radiographic check up with panorama radiograph, the radiolucent lesion with well demarcated scalloped margin was found in the right mandible body, and identified as traumatic bone cyst. In the first case, overinstrumentation was done through the mesial root canal to irrigate the lesion. In the second case, not any treatment was done, and watched the progression of the lesion. And in both cases, after two month, the radiolucency and the size of the lesion has decreased to show healing in progress.

  • PDF

A COMPARATIVE STUDY ON RADIOPACITY OF CANAL FILLING AND RETROGRADE ROOT-END FILLING MATERIALS (근관 충전재 및 치근단 역충전재의 방사선 불투과성에 관한 비교 연구)

  • Kim, Yong-Sang;Kim, Seo-Kyong;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.107-114
    • /
    • 2008
  • This study was performed to assess the radiopacity of a variety of canal filling and retrograde root-end filling materials according to the specification concerning root canal obturation materials. Ten materials including Gutta-percha pellets, amalgam, Fuji II LC, $Dyract^{(R)}$ AP, Super $EBA^{(R)}$, $IRM^{(R)}$, AH $26^{(R)}$, $Sealapex^{TM}$, Tubli-$Seal^{TM}$, and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film were performed at 60 kVp (0.2, 0.3, 0.4 s), 70 kVp (0.2, 0.3, 0.33 s) to decide appropriate voltage and exposure time. In the second part, ten specimens which are 5 mm in diameter and 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm in thickness, were fabricated from each material studied. The specimens were radiographed simultaneously with an aluminum step wedge under decided condition (60 kVp, 0.2 s). The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions including 0.2 s, 0.3 s, 0.4 s at 60 kVp and 0.2 s, 0.3 s, 0.33 s at 70 kVp, the appropriate voltage and exposure time that meet the requirement of density from 0.5 to 2.0 was 0.2 s at 60 kVp. 2. All of the materials in this study had greater radiopacity than the minimun level recommended by ISO No. 4049 standards. 3. Most of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards except for Fuji II LC and Dyract. It suggests that all experimental canal filling and retrograde root-end filling materials have a sufficient radiopacity that meet the requirement concerning root canal obturation materials except for Fuji II LC and Dyract.

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

ERUPTION DISTURBANCE ASSOCIATED WITH A SMALL ODONTOMA (작은 치아종으로 인한 맹출 장애)

  • Song, Ji-Hyun;Lee, Kwang-Hee;Ra, Ji-Young;Lee, Dong-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.490-497
    • /
    • 2007
  • Odontoma is defined as a benign odontogenic tumor containing enamel, dentin as well as cementum and constitued 22% of all odontogenic tumors. Although the lesions are commonly asymptomatic, they may be discovered routine radiographic examination. Odontomas often cause disturbances in the eruption of teeth such as, impaction or delayed eruption, retention of primary teeth, or abnomalities in the position of the teeth such as tipping or displacement of adjacent teeth. Radiologically, odontomas manifest as a dense radiopaque lesion surrounded by a thin radiotransparent halo. However, in some cases, radiopacity was not quite clear and images of the teeth shadowed very tiny odontomas. And at early development stages of odontoma, calcification remains immature and is difficult to diagnose on radiographs. This suggests that when delayed eruption of the teeth is found, periapical radiographs should be taken to clarify whether any small area of radiopaque material exists. This case report shows tiny odontomas involving an impacted tooth and crowding and we remove the tiny odontoma surgically.

  • PDF

A Study on the Compression paddle of meterials in Mammography (유방촬영장치에서 압박대 재질에 관한 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.187-188
    • /
    • 2015
  • 유방촬영은 날로 증가추세에 있으며 압박을통해 영상을 얻는 것이 화질을 향상시키고 피폭선량을 줄이는데 필수적이다. 그러나 압박대 자체의 두께로 인해 산란선과 피폭선량을 증가시킬 수 있으므로 압박대 재질에 대한 고찰이 필요하다. 현재 임상에서 쓰이고 있는 재질은 폴리카보네이트이며 플라스틱 계열이다. 환자의 피폭선량을 줄이기위해 노력한다면 이보다 더 좋은 재질에 대해 고려해볼 필요가 있기에 본 연구에서는 플라스틱 계열 물질 중 비결정 플라스틱에 대한 방사선투과성에 대해 비교해 보고자 한다.

  • PDF

The Evaluation of Radiation Dose by Compression paddle meterials in Mammography (유방촬영장치에서 압박대 재료에 따른 피폭선량 평가)

  • Hong, Dong-Hee;Jung, Hong-Ryang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.183-184
    • /
    • 2014
  • 유방촬영은 날로 증가추세에 있으며 압박을 통해 영상을 얻는 것이 화질을 향상시키고 피폭선량을 줄이는데 필수적이다. 그러나 압박대 자체의 두께로 인해 산란선과 피폭선량을 증가시킬 수 있으므로 압박대 재질에 대한 고찰이 필요하다. 현재 임상에서 쓰이고 있는 재질은 폴리카보네이트이며 플라스틱 계열이다. 환자의 피폭선량을 줄이기 위해 노력한다면 이보다 더 좋은 재질에 대해 고려해볼 필요가 있기에 본 연구에서는 플라스틱 계열 물질과 탄소계열의 카본의 방사선투과성에 대해 비교해 보고자 한다.