Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus (X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향)

  • Lee, Hoo-Min;Yoon, Joon;Kim, Hyun-Ju
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.187-193
    • /
    • 2014
  • The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.

Quality Control and Image Quality Comparison according to Ultrasonic Equipment (초음파 장비에 따른 정도관리와 화질 비교)

  • Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.935-942
    • /
    • 2022
  • In doing interventional treatment under the guidance of ultrasonography, the medical team detects the legion site with ultrasonic equipment at first, and insert angio needle. In this situation, if the position of legion and the depth of inserted needle on the ultrasonographic screen are different from real position and depth, the needle is likely to damage a major blood vessel or tissue. Accordingly, we had wondered how much such differences between screen image and reality, and so decided to examine them. Using five ultrasonographic equipments manufactured from different companies in different years, this study tried to compare the lengths of the needle on the screen images and real lengths of it, and find out the factors affecting skewness of them. This study used hog meat chunk to mimic human flesh, and sausages as the target of needle. It compared penetrating depths of the needle as the images on the five equipments using single sample t test in the SPSS 22 statistical program. It was found that all the errors were statistically significant(<.05). So, this study decided that it was wrong to evaluate performances of the equipments by the makers and ages of them. It is necessary to do periodic quality controls of equipments and improve the skillfulness of sonographers to reduce error rates between real treatment areas and the images of them.

Shielding Effectiveness of Magnetite Heavy Concrete on Cobalt-60 Gamma-rays

  • Lim, Yong-Kyu
    • Nuclear Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.65-75
    • /
    • 1971
  • The gamma-ray shielding effects of magnetite concretes have been measured using a broad beam Co-60 gamma-ray source. Mathematical formulae for a trans-mission ratio-to-shield thickness relation were derived from the attenuation curve obtained experimentally and are I (x) = I (ο) exp(-$\mu$X) exp(1.03$\times$10$^{-1}$ X-3.38$\times$10$^{-3}$ X$^2$+5.29$\times$10$^{-5}$ X$^3$) when X< 20 cm, I (x) =I (ο) exp(-$\mu$X) exp(4.66$\times$10$^{-2}$ X+2.12$\times$10$^{-1}$ ) when X>20 cm. Here I (x) is radiation intensity after passing through a thickness X of absorber, I(o) is the initial radiation intensity, $\mu$ is the linear attenuation coefficient of magnetite concrete and is given by (0.0532$\rho$+ 0.0083)$^{4)}$ $cm^{-1}$ / in accordance with an earlier study, and X is the thickness of absorber. In addition, a model shield which is a rectangular magnetite concrete box with walls of 8cm thickness walls and internal demensions of 40$\times$40$\times$40 cm was constructed and its shielding effect has been measured. The emergent radiation flux appears to be greater with this configuration than with a slab shield of equal thickness.

  • PDF

Preparation of Anion-exchange Membrane for Selective Separation of Urea and Ion (요소(Urea) 및 이온의 선택적 분리를 위한 음이온교환막의 제조)

  • Kim, Byoung-Sik;Kim, Min;Heo, Kwang-Beom;Hong, Joo-Hee;Na, Won-Jae;Kim, Jae-Hun
    • Applied Chemistry for Engineering
    • /
    • v.17 no.3
    • /
    • pp.303-309
    • /
    • 2006
  • In this study, functional anion-exchange membranes have been prepared and characterized to improve the permeation fluxes of the anion and urea for peritoneum dialysis. They were prepared by UV and radiation graft polymerization methods. The separation-membrane prepared by UV graft polymerization showed the highest grafting degree when HEMA and VBTAC were mixed by 1:2 ratio. However, the grafting degree decreased slightly at compositions above the 1:2 ratio because of the disruption of UV penetration caused by build-up of homopolymer. In the case of photo-initiator, the grafting degree increased up to 0.2 wt%, above which it decreased to a small extent. For the two membranes prepared by radiation graft polymerization, the VBTAC/HEMA membrane showed 96% grafting degree for 6 h reaction time and the GMA membrane showed over 100% grafting degree for 2 h reaction time. Anion-exchange membranes were prepared with 113% grafting degree and with DEA and TEA exchange groups. The DEA membrane showed the conversion degree of 70% in 4 h reaction time while the TEA membrane showed 30% in 2 h reaction time. The prepared anion-exchange membranes were permeable to only anions and urea, but not cations.

Electro-electrodialysis Using the Radiation-treated Cation Exchange Membrane by Accelerated Electron Radiation to Concentrate HI from HIx Solution (전자선 가속기에 의해 방사선 처리한 양이온교환막을 이용한 전해-전기투석에 의한 HIx용액으로부터 HI의 농축)

  • Hwang, Gab-Jin;Kim, Jeong-Keun;Lee, Sang-Ho;Choi, Ho-Sang
    • Membrane Journal
    • /
    • v.17 no.4
    • /
    • pp.338-344
    • /
    • 2007
  • Electro-electrodialysis of hydriodic acid with HI molality of ca. 9.5 $mol/kg-H_2O$ was examined in the presence of iodine using a commercial cation exchange membrane, CMB, as a separator. For the increase of the selectivity of proton permeation, the membrane was radiation-treated by accelerated electron radiation. The membrane properties (area resistance, ion exchange capacity, water content) of the radiation-treated membranes were measured. The area resistance in 2 $mol/dm^3$ KCl solution, ion exchange capacity and water content of the radiation-treated membranes at each dose rate dad almost the same value as that of the non-treated membrane (original of CMB membrane). Electro-electrodialysis of hydriodic acid with HI molality of ca. 9.5 $mol/kg-H_2O$ was examined at $75^{\circ}C$ with 9.6 $A/dm^2$. The radiation-treated cation exchange membrane by accelerated electron radiation had higher selectivity of the proton permeation by cross-linking structure of polymer than that of the non-treated membrane.

High Energy Photon Dosimetry by ESR Spectroscopy in Radiotherapy (ESR Spectroscopy에 의한 치료용 고에너지 광자선의 선량측정)

  • Chu, Sung-Sil
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.31-42
    • /
    • 1990
  • The finding of long lived free radicals produced by ionizing radiation in organic crystals and the quantification of this effect by electron spin resonance(ESR) spactroscopy has proven excellent dosimetric applicability. The tissue equivalent alanine dosimeter also appear appropriate for radiation therapy level dosimetry. The dose measurement was performed in a Rando phantom using high energy photons as produced by high energy medical linear accelerator and cobalt-60 teletherapy unit. The absorbed dose range of the ESR/alanine dosimetry system could be extended down to 0.1 Gy. The response of the alanine dosimeters was determined for photons at different therapeutic dose levels from less than 0.1 Gy to 100 Gy and the depth dose measurements were carried out for photon energies of 1.25MeV, 6 and 10 MV with alanine dosimeters in Rando phantom. Comparisons between ESR/alanine in a Rando phantom and ion chamber in a water phantom were made performing depth dose measurements to examine the agreement of both methods under field conditions.

  • PDF

Performance Evaluation of Domestic Prototype Dose Area Product Meter SFT-1 (국산 프로토타입 면적선량계 SFT-1의 성능평가)

  • Lee, Ho-Sun;Han, Seong-Gyu;Roh, Young-Hoon;Lim, Hyun-Jong;Kim, Jung-Min;Kim, Jong-Uk;Chae, Hyun-Sik;Yoon, Yong-Su
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.435-441
    • /
    • 2016
  • The importance of radiation dose display of medical X-ray equipment was emphasized, while third edition of IEC(International Electrotechnical Commission) 60601 started to apply. The existing medical X-ray equipment selected a method for attaching the DAP(Dose Area Product) meter when the dose display. However, because the DAP meter was dependent on all of the income, And it did not yet produced in Korea. So, we received the support of Seoul R&BD Program(Grants No. C1152055) to produce DAP meter prototype of the Domestically technology. In this study, the performance of this prototype was evaluated by comparing the German company's product Evaluation item was an electronic capture performance, radiation dose dependence, radiation quality dependence, energy transmittance, repeatability, light transmittance of 6 entries. And IEC 60580 was based on this evaluation. Evaluation results were electronic capture performance intrinsic error 9.5%, radiation dose dependence limits of variation 1%, repeatability coefficient of variation 2%, energy transmittance 91% each assessment was passed. However radiation quality dependence limits of variation 29%, light transmittance 55% was less than acceptance criteria.

Evaluation of the Shielding Effect of Polyvinyl Chloride (PVC) on Low-dose Blending Radiation Energy (폴리 염화 비닐(PVC)의 저선량 융합 방사선에너지에 대한 차폐 효과 평가)

  • Kim, Seon-Chil;Cho, Sung-Hyoun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.129-134
    • /
    • 2019
  • PVC was chosen as a plastic product that can cope with lead, a radiation shielding material that is widely used in medical institutions. In addition to radiation shielding clothing, we want to evaluate whether it can be used as a medical device component and industrial shielding material in low dose areas. Commercial PVC has a density of 3.68 g/㎠ and can be positively expected sufficient shielding effect in certain radiation areas such as material flexibility and economy efficiency, and can be transformed into various forms and used as a lightweight shielding wall. The shielding performance was tested by adjusting the thickness of 5 sheets of 3mm PVC in the range of medical radiation used for clinical examination in medical institutions. Shielding performance against effective energy was evaluated based on tube radiation voltage of medical radiation. The thicker the PVC, the lower the tube voltage and the lower the effective energy, the greater the shielding effect. The shielding effect was 70% at 12mm thickness and 80kVp tube voltage. Therefore, the shielding effect of PVC material has a high dependence of thickness. In the future, continuous research is needed to make thin and light eco-friendly products while improving shielding performance.

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom (팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가)

  • Lim, Jin-Oh;Kim, Tae-Hyung;Jung, Yang-Hwa;Choi, Won-Chan;Shin, Ji-Hoon;Song, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.21-26
    • /
    • 2003
  • To evaluate the newly designed gastroduodenal coil catheter:in-vitro test. The coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3 mm inner diameter and this coil spring was covered with heat-shrinkable polyethylene tube. To measure the length under fluorocopy, 8 radiopaque marks were attached at 5 cm, 10 cm, 11 cm, 12 cm, 13 cm, 14 cm, 15 cm, 20 cm apart from distal end of the catheter and 6, 2, 1 pores were made at 7 cm, 13 cm, 19 cm apart from the distal end. Radio-opacity and the amount of injected contrast was investigated in formerly used 5 Fr. vessel catheter, which is possible in measuring length, and newly designed coil catheter. Film density was tested for radio-opacity with autodensitometer. For measuring the volume of injected salin, the catheter was located in the acryl box(26 cm, 3 cm, 16 cm) that divided into 4 chambers. After injection 50 cc of contrast with autoinjector, the contrast's quantity in each chamber was measured with and without over the guide wire. Radio-opacity was 0.51 in 5 Fr. vessel catheter, 0.31 in newly made catheter. The amount of injected contrast was measured. In case of 5 Fr. vessel catheter, the amount was 99.5% from the distal part, there was no difference between with and without the guide wire. Otherwise, using a coil catheter, the pacentage the ejected saline was 1.17%, 18.8%, 41.8%, 38.2% from the distal part with the guide wire, 19.5%, 32.6%, 27.7%, 20.3% without the guide wire. Compare with formerly established catheter, this new coil catheter is easy to measure the length thanks to easy confirming under fluoroscopy and excellent in injecting contrast. Therefore, newly designed gastrointestinal catheter seems to be useful in gastrointestinal intervention procedure.

  • PDF

Effects of Low Dose Gamma-irradiation on Alleviation of Salt Stress in Rice (Oryza sativa L.) Seedling (저선량 감마선 조사가 벼 유묘의 염 스트레스 경감에 미치는 영향)

  • Baek, Myung-Hwa;Kim, Jin-Hong;Wi, Seung-Gon;Lee, In-Jung;Lee, Kyu-Seong;Kim, Jae-Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.2
    • /
    • pp.153-158
    • /
    • 2005
  • To investigate alleviation effects of salt stress by low dose gamma-irradiation on seedling growth of rice (Oryza shrive L), in plants of two rice cultivars (Ilpumbyeo and Gancheokbyeo), seeds were irradiated with the different doses $(0{\sim}32\;Gy)$ of gamma-ray by irradiator ($^{60}Co$, ca.150 TBq of capacity, AECL). The salt stress caused a remarkable decrease of seedling growth, particularly for dry weight. In addition, relative growth rate was decreased over 50% by the salt stress. However, the salt stress-induced inhibition of growth was alleviated by gamma-irradiation. Especially, the relative growth rate of shoot showed the reduction effect over 30% at 4 Gy-irradiated groups as compared with that of control. Also, electrolyte leakage and relative water content were damaged, respectively 4 times and 30% by the salt stress but the damages were alleviated by the gamma-irradiation. These alleviation effects were observed similarly in both the cultivars tested. These results suggest that the low dose gamma-irradiation may have a better protection or the salt stress.