• Title/Summary/Keyword: 방사선 치료실

Search Result 79, Processing Time 0.025 seconds

Effect of Microwave Hyperthermia on Radiotherapy of Human Malignant Tumors -An Analysis of Clinical Response of 42 Patients- (극초단파를 이용한 국소온열 치료 효과 -표재성 종양 42예의 분석-)

  • Yoon Sei Chul;Oho Yoon Kyung;Gil Hak Jun;Chung Su Mi;Shinn Kyung Sub;Bahk Yong Whee
    • Radiation Oncology Journal
    • /
    • v.5 no.1
    • /
    • pp.31-36
    • /
    • 1987
  • Radiobiological and clinical evidences indicate that hyperthermia combined with ionizing radiation produces a significant improvement in therapeutic effect of cancer. In general, malignant cells are more sensitive to heat than normal cells in the heat range of $41\~45^{\circ}C$. We report the experiences obtained from 42 patients with advanced malignant neoplasms managed with 2,450MHz microwave-induced local hyperthermia and ionizing radiation at the Department of Radiology, Kangnam St. Mary's Hospital, Catholic University Medical College. A clinical analysis of 42 thermoirradiated patients showed result of 11(26\%),\;15(36\%),\;11(26\%)\;and\;5(12\%)$ patients with complete response (CR), partial response (PR), minor response (MR) and no response (NR), respectively. Histologically there were $17(40.2\%)$ squamous cell carcinomas, $12(28.6\%)$ adenocarcinomas and $6(14.3\%)$ miscellaneous cancers. Eleven patients with CR consisted of five squamous cell carcinomas, five adenocarcinomas, and one chloroma. Among 15 patients with PR were five squamous cell carcinomas, five adenocarcinomas, three unknown primary tumors, and one poorly differentiated, and miscellaneous tumor each.

  • PDF

Preliminary Results of Stereotactic Radiosurgery Using Stereotactic Body Frame (정위 체부 고정틀을 이용한 체부 방사선수술의 예비적 결과)

  • Ahn Seung Do;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoo;Nho Young Ju;Shin Kyung Hwan;Kim Kyoung Ju;Chung Won Kyun;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.251-256
    • /
    • 2000
  • Purpose : To evaluate efficacy and complication of stereotactic radiosurgery using stereotactic body frame. Methods and Materials :From December 1997 to June 1999, 11 patients with primary and metastatic tumors were treated with stereotactic radiosurgery using stereotactic body frame(Precision TherapyTu). Three patients were treated with primary hepatoma and seven with metastatic tumor from liver, lung, breast, trachea and one with arteriovenous malformation on neck. We used vacuum pillow for immobilization and made skin marker on sternum and tibia area with chest marker and leg marker. Diaphragm control was used for reducing movement by respiration. CT-simulation and treatment planning were peformed. Set-up error was checked by CT-Simulator before each treatment. Dose were calculated on the 80$\~$90$\%$ isodose of isocenter dose and given consecutive 3 fractions for total dose of 30 Gy (10 Gy/fraction). Results :Median follow-up was 12 months. One patient (9$\%$) showed complete response and four Patients (36$\%$) showed partial response and others showed stable disease. Planning target volumes (PTV) ranged from 3 to 111 cc (mean 18.4 n). Set-up error was within 5 mm in all directions (X, Y, Z axis). There was no complication in all patients. Conclusion :In Primary and metastatic tumors, stereotactic body frame is very safe, accurate and effective treatment modality.

  • PDF

The Effect of External Radiation Therapy for Intracrania1 Arteriovenous Malformation - Conventional Radiation Therapy vs Stereotactic Radiosurgery - (뇌동정맥성 기형의 외부방사선 치료 효과)

  • Kim In Ah;Jang Hong Suk;You Mi Ryung;Yoon Sei Chul;Kim Moon Chan;Shinn Kyung Sub;Bahk Yong Whee
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.53-58
    • /
    • 1991
  • From February 1987 through July 1990, the seventeen cases of inoperable intracranial arteriovenous malformation (AVM) were treated using 6 MV linear accelerator at the Division of Therapautic Radiology, Kang Nam 51. Mary's Hospital. Of seventeen cases, fourteen were male and three were female. Ages ranged from 10 to 51 years (median age of 25 years). The main symtoms were headache, epilepsy and hemiparesis in decreasing order of frequency. The middle cerebral artery is the most common origin of the feeding vessel $(41.2\%)$. Four were treated by conventionally fractionated radiation therapy (CRT, thirteen were treated by stereotactic radiosurgery (RS). duration or follow-up in CRT and RS group were 4 to 43 months (median 33 months) and 3 to 12 months (median 13 months), respectively. When the response was assessed by radiologic follow-up study, two of four CRT group showed minimal response. Of thirteen cases of RS group, two $(15.4\%)$ showed complete response, five $(38\%)$ partial response, two $(15.4\%)$ minimal response and four $(30.7\%)$ no response by the same assessment. There was no statistical significance in terms of follow-up period (p=0.22), size of lesion (p=0.82) and treated dose (p=0.05). Further accumulation of experience is recommended with proper case selection and sufficient follow-up period.

  • PDF

The Effect of Radiation Therapy on Oligodendrogliomas (회돌기교종의 방사선치료 효과)

  • Yoon Sei Chul;Kim Sung Whan;Chung Soo Mi;Gil Hok Jun;Shinn Kyung Sub;Bahk Yong Whee;Kang Joon Ki;Song Jin Un
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.47-52
    • /
    • 1991
  • From April,1983 through April,1989, we have treated histologically proven 21 patients with oligodendroglioma using 6 MV linear accelerator at the Division of Radiation Therapy, Kangnam 51. Mary's Hospital Catholic University Medical College. These are 8% of the irradiated 246 primary brain tumors during the same period. To investigate influencing factors on the survival of irradiated U patients with oligodendroglioma, we analyzed the cerebral location of the involvements, initial symptoms, CT findings and survival rates, retrospectively. One case was lost to follow up and excluded from survival data. Of the 28 patients, thirteen were male and 8 female. Ages ranged from 5 to 68 years with a median age of 38 years. Radiation doses varied from 3900 cGy to 0480 cGy and were given for 5 to 8 weeks. All but one were supratentorial. The involvement of the frontal and parietal lobes were 10 (48%) patients in each and temporal lobe in 8 (38.1%). Histological diagnosis was made by stereotactic biopsy in 3 and postoperatively in 18. The type of surgery was divided into partial, subtotal and total resection in 7,9 and 2 cases respectively. In 6 cases, chemotherapy was also tried during or after radiation therapy. Major presenting symptoms were headache, cerebral motor, nausea & vomiting and epilepsy in 18,12, 7 and 5 respectively in decreasing order. In CT analysis, low density (02%), cystic mass (33%), calcifiestion (66%) and positive contrast enhancement (42.8%) were observed as the highest frequency. Mean survival duration after radiation therapy was 38 months (K-M methods). We could not achieve statistically significant factors influencing on the survival rate after radiation therapy for oligodendrogliomas by one or two tail test.

  • PDF

Clinical Application of the Dual Energy Photon Beam Using 6 MV and 10 MV X-ray (6MV 및 10 MV X-ray의 이중에너지를 생성하는 방사선 발생장치의 임상적 이용)

  • Lee, Myung-Za;Han, Hye-Gyeong
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.93-99
    • /
    • 1988
  • Some modern accerelators provide a dual energy for photon beam treatment. The main advantages of dual energy in the treatment of rectosigmoid or rectal cancer are as fellows. 1. Dose in the critical organ such as small intestine, bladder and genital organ are reduced. 2. Presacral and perineal area is fully covered. Dose distribution analysis such as calculation of dose in a target volume, isocenter, $D_{nax}$ and dose spectrum in any region of interest are possible. Examples of plan are given and results are discussed.

  • PDF

The establishment of Digital Image Capture System(DICS) using conventional simulator (Conventional simulator를 이용한 Digital image capture system(DICS)의 구축)

  • Oh Taesung;Park Jongil;Byun Youngsik;Shin HyunKyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.25-32
    • /
    • 2004
  • Purpose : The simulator is used to determine patient field and ensure the treatment field, which encompasses the required anatomy during patient normal movement such as during breathing. The latest simulator provide real time display of still, flouroscopic and digitalized image, but conventional simulator is not yet. The purpose of this study is to introduce digital image capture system(DICS) using conventional simulator and clinical case using digital captured still and flouroscopic image. Methods and materials : We connect the video signal cable to the video terminal in the back up of simulator monitor, and connect the video jack to the A/D converter. After connection between the converter jack and computer, We can acquire still image and record flouroscopic image with operating image capture program. The data created with this system can be used in patient treatment, and modified for verification by using image processing software. (j.e. photoshop, paintshop) Result : DICS was able to establish easy and economical procedure. DCIS image was helpful for simulation. DICS imaging was powerful tool in the evaluation of the department specific patient positioning. Conclusion : Because the commercialized simulator based of digital capture is very expensive, it is not easily to establish DICS simulator in the most hospital. DICS using conventional simulator enable to utilize the practical use of image equal to high cost digitalized simulator and to research many clinical cases in case of using other software program.

  • PDF

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Evaluation of the Breast plan using the TLD and Mosfet for the skin dose (열형광선량계(TLD)와 MOSFET을 이용한 유방암 방사선치료계획에 대한 피부선량 평가)

  • Kim, seon myeong;Kim, young bum;Bak, sang yun;Lee, sang rok;Jeong, se young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.107-113
    • /
    • 2015
  • Purpose : The measurement of skin dose is very important that treatment of breast cancer. On account of the cold or hot dose as compared with prescription dose, it is necessary to analyse the skin dose occurring during the various plan of the breast cancer treatment. At our hospital, we want to apply various analyses using a diversity of dosimeters to the breast cancer treatment. Subjectss and Methods : In the study, the anthropomorphic phantom is used to find out the dose difference of the skin(draining site), scar and others occurring from the tangential treatment plan of breast cancer. We took computed tomography scan of the anthropomorphic phantom and made plans for the treatment planing using open and wedge, Field-in-Field, Dose fluence. Using these, we made a comparative analysis of the dose date points by using the Eclipse. For the dose comparison, we place the anthropomorphic phantom in the treatment room and compared the measurement results by using the TLD and MOSFET on the dose data points. Results : On the central point of treatment planing basis, the upward and downward skin dose measured by the MOSFET was the highest when the fluence was used. The skin dose of inner and outer was distinguished from the figure(5.7% ~ 10.3%) when the measurements were fulfilled by using TLD and MOSFET. The other side of breast dose was the lowest in the open beam, on the other hand, is highest in the Dose fluence plan. In the different kinds of treatment, the dose deviation of inner and outer was the highest, and so this was the same with the TLD and MOSFET measurement case. The outer deviation was highest in the TLD, and the Inner'was highest in the MOSFET. Conclusion : Skin dose in relation to the treatment plan was the highest in the planing using the fluence technique in general and it was supposed that the high dose had been caused by the movement of the MLC. There's some differences among the all the treatment planning, but the sites such as IM node occurring the lack of dose, scar, drain site are needed pay close attention. Using the treatment planning of dose fluence is good to compensate the lack of dose, but It increases the dose of the selective range rather than the overall dose. Therefore, choosing the radiotherapy technique is desirable in the lights of the age and performance of the patient.

  • PDF

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

Thymus Size and Its Relationship to Perinatal Diseases; Respiratory Distress Syndrome and Intrauterine Growth Retardation (흉선의 크기와 주산기 질환들과의 관계)

  • Chung, Sun Mi;Kim, Woo Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.7
    • /
    • pp.855-861
    • /
    • 2002
  • Purpose : Thymus size can be affected by several factors and perinatal diseases can be estimated by its size. The purpose of this study was to search for a relationship between cardiothymic/thoracic(CT/T) ratio and perinatal diseases such as neonatal respiratory distress syndrome(RDS) and intrauterine growth retardation(IUGR) by measuring the width of the cardiothymic shadow at the level of the carina and dividing it by the width of the thorax at the costophrenic angles. Methods : A clinical study was conducted on newborn infants with RDS(n=51), IUGR(n=27), and premature rupture of membranes(PROM, n=48), who were admitted at NICU of Catholic University of Daegu from June 2000 to Oct. 2001. CT/T ratio was measured within six hrs of age, at 2-3 days of age, and at 5-7 days of age. Results : CT/T ratios of RDS group, IUGR group, and PROM group were $0.46{\pm}0.07$, $0.32{\pm}0.04$. $0.36{\pm}0.06$, respectively. CT/T ratios of RDS group within 6hrs of age, at 2-3 days of age, and at 5-7 days of age were $0.43{\pm}0.07$, $0.34{\pm}0.06$, $0.25{\pm}0.04$, respectively. There were statistically significances among the RDS group, the IUGR group, and the PROM group and in the RDS group at different times. Regression for gestational age among three groups was not statistically significant but correlation for gestational age in the entire groups was statistically significant. CT/T ratio between normal spontaneous vaginal delivery and c-section among three groups was not statistically significant. CT/T ratios with dexamethasone-treated group and untreated group was not statistically significant. Conclusion : We concluded that thymus size differed significantly in the perinatal diseases such as RDS and IUGR, and so can be used as an early diagnostic tool for perinatal diseases.