• Title/Summary/Keyword: 방사선 촬영법

Search Result 261, Processing Time 0.024 seconds

A Study on Projection for Apophyseal Joints Diagnosis in X-ray Thoracic Bone Oblique Projection (X-ray 등뼈의 사위 촬영에서 돌기사이관절의 진단을 위한 촬영법 연구)

  • Jun-Heang Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.351-357
    • /
    • 2023
  • This Study Rreceived Subjective Evaluation ROC Evaluation from five projection. of projection. at a University Hospital to Obtain and Diagnose Sharp images of apophyseal joints and Vertral arch of Thoracic vertebrae from thoracic X-ray projection. In the Subjective evaluation, the highest Score was obtained by raising the phantom from Supine to LAO by 70° and scoring 20 points at 5° with the X-ray Tube facing the head. In addition, he scored the highest score of 19 points at 8° with the Prone Phantom standing 60° with RAO and the X-ray Tube facing the head. For Objective Evaluation, the Signal-to-noise ratio, was calculated. ROI was set at 1,564 mm2 to obtain the image signal average value (Mean value) and the Standard deviation (SD value). Objective Evaluation The signal-to-noise ratio, was the highest at 5° toward the head in the LPO 70° position of the phantom in the lying position of the Thoracic spine projection, and the Thoracic Spine was the highest at 8° toward the head of the RAO posture of 5,645.

A Study of Radiographic Methods to X-ray Study of Patients with Spinal Scoliosis and Vertebrae Bone Fracture of Lumbar Spine (척주측만증과 허리뼈 골절 수술 환자의 엑스선 촬영법 연구)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.425-431
    • /
    • 2019
  • The Study In order to obtain images of overlap of the two iron cores in the spinal cord simple x-ray scan after surgery of patients with ulcer lateral sclerosis and a fractured backbone, the researcher conducted a subjective evaluation on five radiographers of the university hospital's imaging department for more than 10 years. The results of the experiment showed that the lateral shot of lateral scoliosis of the spinal cord was taken with the middle face of the IR plane, and then the X-ray tube angle was taken vertically with the vertical spinal column fan-tom position, resulting in two overlapping images and high scores in the subjective evaluation. In addition, lateral shots of the lumbar dislocation fractured lumbar vertebrae were taken with the forehead aligned with the center of the IR plane and then with the X-ray angle perpendicular to the fourth waistline and the angle of the spinal cord perpendicular to the fourth waistline, the image of the two iron cores could be obtained from the radiographer.

The Effect of Splinting with Concomitant Root Planing;Clinical and Digital Subtraction Radiographic Study (치근활택술과 스프린트 병행처치의 효과에 관한 연구;디지털 공제 촬영술을 이용한 임상적 연구)

  • Lee, Ji-Young;Kye, Seung-Bum;Kim, Won-Kyoung;Lee, Yong-Moo;Ku, Young;Ryu, In-Chul;Chung, Chong-Pyoung;Choi, Sang-Mook;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.1
    • /
    • pp.207-227
    • /
    • 2001
  • 스프린트는 치주처지료에서 부가적 처치법으로 널리 사용되고 있으며, 한편, 디지털 공제 활영술은 기존방사선촬영술의 한계점을 극복하기 위해 기발된 새로운 방법이다. 이번 연구에서는 치근활택술 단독시행시와 스피린트 병행 처치시의 효과를 임상적, 방사선학적으로 비교하였다. 중정도의 성인성 치주염을 가진 20명의 환자를 대상으로 하되 10명은 치근활택술 단독으로, 나머지 10명은 스프린트 병행처치로 처치하였다. 임상적, 방사선학적인 평가는 처치전, 처치후 6개월에 행하고, 임상적 평가의 경우 3개월에 추가로 실시하였다. 이번 연구에서 사용된 임상 지수로는 치태지수, 치은지수, 치은퇴축, 치주낭깊이, 임상부착수준, 임상부착증가, 탐침시출혈, 치아동요도 등이며, 방사선학적 평가는 기존 방사선촬영술에 의한 방법과 디지털 공제촬영수렝 의한 방법으로 행하였다. 디지털 공제 촬영술에 의한 평가시, 영상은 Digora 프로그램에 의해 획득하고 Emago 프로그램으로 처리 하여 다음과 같은 결론을 얻었다. 1. 처치후 3개월에 치태지수, 치은지수, 치은퇴축, 치주낭깊이, 임상적부착수준, 탐침시 출혈 등의 임상지수들이 변했으며, 특히 이러한 변화는 치주낭깊이, 치은퇴축, 탐침시출혈에서 유의성이 있었다. ( p<0.05 ) 그러나 두군간 차이는 인정되지 않았다. ( p>0.05 ) 2. 처치후 6개월에도 치태지수, 치은지수, 치은퇴축, 치주낭깊이, 임상적부착수준, 탐침시출혈, 치아동요도 등의 임상지수들이 변했으며, 특히 이러한 변화는 치주낭깊이, 치은퇴축, 탐침시출혈, 치태지수, 치아동요도에서 유의성이 있었다. ( p<0.05 ) 그러나 두 군간 차이는 인정되지 않았다. ( p>0.05 ) 3. 켄달 상관분석시, 임상적 평가와 기존 방사선 촬영술에 의한 평가사이의 관련성을 낮았으며 거의 0에 가까운 수치를 보였으며 (r=0.110, p=0.639 ) 임상적 평가와 디지털 공제 방사선 촬영술에 의한 평가사이에서 약간 높은 관련성을 보였다. ( r=0.257, p=0.315 ) 즉 치주치료후의 골변화는 디지털 공제 방사선 촬영술에 의한 평가시 기존 방사선 사진보다 임상적 부착증가와 더욱 긴밀한 관련성을 보여준다. 이상의 결과로 볼 때, 스프린팅 처치는 치주 치료에 있어 치근활택술에 부가적 표과를 제공하지 못한다.

  • PDF

A comparison of periapical radiographs and their digital images for the detection of dental caries (인접면 치아우식증의 진단의 치근단 X선사진과 디지털영상의 비교)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.31-35
    • /
    • 1994
  • 전남대학교 치과진료처에 내원한 환자의 구내방사선사진중 1단계 (Cl: 30개 병소)또는 2단계(C2: 213.8병소)의 인접면 치아우식을 가진 방사선사진 168장을 연구대상으로 하였다. 이들 방사선사진은 코닥사의 Ektaspeed(E group) 필름을 사용하여 평행촬영법으로 촬영하였다. 168장의 방사선사진에 대하여 1단계 및 2단계 치아우식증을 4명의 구강악안면방사선학을 전공한 치과의사들이 같이 판독하여 그 결과를 기록하였다. 또한 168장의 방사선사진을 필름-비디오 변환장치를 이용하여 디지털 영상으로 전환하였다. 이때 486 DX PC에 PCVision과 frame grabber를 이용하였다. 각각의 구내방사선사 진영상은 17"크기의 1280×768픽셀의 해상도를 갖는 모니터상에서 256단계 흑화도를 갖는 700×480픽셀로 제시되었다. 모니터상에서의 치아우식 판독 결과를 구내방사선사진 판독 결과와 비교하였다. 그 결과 sensitivity는 0.98이었다. 1단계 치아우식은 0.87, 2단계 치아우식 은 1.00의 sensitivity를 나타내었다.

  • PDF

The Study of Grashey Method Viewing the Glenohumeral(shoulder) Joint (어깨관절의 접시오목을 나타내는 Grashey법에 대한 연구)

  • Lee, Jaeseob;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.331-335
    • /
    • 2015
  • Consideration of Glenohumeral joint's image with the Changed Body angle of the Glenohumeral joint's Oblique Position in Erect Position. Glenohumeral joint's of Grashey method is a shoulder oblique method available to view the shoulder joint. Grashey method projects AP view of the Glenohumeral joint's so that the Humerus head's subluxation or joint degeneration can be easily visualized. However in this view, the patients, erect position, have to keep their body obliquely. Oblique position is will be needed to get the good quality Glenohumeral joint's view. Therefore, we thought of examining a method which shows the Glenohumeral joint's well by angling the patient one side upward in erect position. For this study, total 20 subject with no history of neurological or psychiatric illness, were recruited for examinations. They consisted of 13 mails and 7 femails, Statistic group analysis was performed with ANOVA test. Score of the evaluation of the expects were $30^{\circ}$ at $0.40{\pm}0.499$, $35^{\circ}$ at $1.34{\pm}0.657$, $40^{\circ}$ at $1.84{\pm}0.573$, $45^{\circ}$ at $0.76{\pm}0.649$, and they were significant(P<0.05). The degree of $40^{\circ}$ views were shown to yield good quality shoulder oblique images.

Comparison of Image Quality and Dose between Intra-Venous and Intra-Arterial Liver Dynamic CT using MDCT (MDCT를 이용한 역동적 간 컴퓨터단층촬영 검사에서 정맥과 동맥 주입법에 따른 영상의 화질 및 선량 비교)

  • Ji-Young, Kim;Ye-Jin, Cho;Hui-Hyeon, Im;Ju-Hyung, Lee;Yeong-Cheol, Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.123-129
    • /
    • 2023
  • The purpose of this study was to analyze differences in imaging quality and dose difference between intra-venous (IV) and intra-arterial (IA) liver dynamic computed tomography (CT). Herein, retrospective, blinded analysis was conducted to analyze signal-to-noise and contrast-to-noise ratios in cases of patients who underwent IV or IA liver dynamic CT for transarterial chemoembolization (TACE), an interventional procedure for hepatocellular carcinoma. The dose length product (DLP) value stored in Picture Archive and Communication System (PACS) was used to calculate the effective dose and thereby compare differences in the dose between the two methods. The mean liver and spleen signal to noise ratio (SNR) was greater in IV-liver dynamic CT than in IA-liver dynamic CT; however, contrast to noise ratio (CNR) was higher in IA-liver dynamic CT than in IV-liver dynamic CT. However, there were no differences in DLP and effective dose between the two methods. In conclusion, our findings showed that IA-liver dynamic CT showed a similar effective dose and superior CNR compared with IV-liver dynamic CT. Further studies must analyze 3D angiography CT of the hepatic artery to clearly distinguish the feeding artery, which is the essential step in interventional procedures for hepatocellular carcinoma.

The Evaluation of Usefulness New Assistant Device to Observe Posterior Cruciate Ligament Rupture and Patellofemoral Joint Injury in Emergency Patient (응급환자에서 후방십자인대 손상 및 슬대퇴 관절을 관찰하기 위한 보조기구 제작 및 유용성 평가)

  • Seo, Sun-Youl;Han, Man-Seok;Jeon, Min-Chul;Yu, Se-Jong;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.93-96
    • /
    • 2010
  • This study evaluates usefulness of the developed assistant device by taking projection of patellofemoral joint in emergency patients who were doubt posterior cruciate ligament injury in knee joint. The subjects of experiment were patients who visited Eul-Ji University Hospital due to knee injury from January 2006 to December 2006. Seventeen patients, who took the Knee post stress view, Knee merchant view, Knee Seo's view to use assistant device and Knee MRI. To make assistant device of $170{\times}50{\times}70\;cm$, we evaluated its usefulness by measuring posterior dislocation of tibia. Seo's view is more accurate to make judgment of posterior cruciate ligament injury than original knee post stress view. Interval difference of posterior dislocation of original knee post stress view is $6.17{\pm}3.04$ and Seo's view is $8.74{\pm}4.47$. The results show injury of patellofemoral joint, vertical fracture of patella and posterior cruciate ligament injury by taking a projection using Seo's view. Therefore, it is useful to take projection earlier than talometer and MRI in emergency patients who were doubt posterior cruciate ligament injury in knee joint.

Material Decomposition through Weighted Image Subtraction in Dual-energy Spectral Mammography with an Energy-resolved Photon-counting Detector using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 광자계수검출기 기반 이중에너지 스펙트럼 유방촬영에서 가중 영상 감산법을 통한 물질분리)

  • Eom, Jisoo;Kang, Sooncheol;Lee, Seungwan
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.443-451
    • /
    • 2017
  • Mammography is commonly used for screening early breast cancer. However, mammographic images, which depend on the physical properties of breast components, are limited to provide information about whether a lesion is malignant or benign. Although a dual-energy subtraction technique decomposes a certain material from a mixture, it increases radiation dose and degrades the accuracy of material decomposition. In this study, we simulated a breast phantom using attenuation characteristics, and we proposed a technique to enable the accurate material decomposition by applying weighting factors for the dual-energy mammography based on a photon-counting detector using a Monte Carlo simulation tool. We also evaluated the contrast and noise of simulated breast images for validating the proposed technique. As a result, the contrast for a malignant tumor in the dual-energy weighted subtraction technique was 0.98 and 1.06 times similar than those in the general mammography and dual-energy subtraction techniques, respectively. However the contrast between malignant and benign tumors dramatically increased 13.54 times due to the low contrast of a benign tumor. Therefore, the proposed technique can increase the material decomposition accuracy for malignant tumor and improve the diagnostic accuracy of mammography.