• Title/Summary/Keyword: 방사선

Search Result 16,248, Processing Time 0.042 seconds

Clinical Manifestations of Pulmonary Infection Due to Rapidly Growing Nontuberculous Mycobacteria (신속발육 비결핵항산균에 의한 폐감염의 임상상)

  • Kim, Eun Kyung;Shim, Tae Sun;Lim, Chae-Man;Lee, Sang Do;Koh, Younsuck;Kim, Woo Sung;Kim, Won Dong;Kim, Dong Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.3
    • /
    • pp.283-294
    • /
    • 2003
  • Introduction : Rapidly growing nontuberculous mycobacteria (RGM) can produce numerous types of manifestations including a pulmonary infection. Managing a pulmonary infection due to RGM is unusually difficult to treat because the organism is invariably resistant to traditional antituberculous drugs and has a varying susceptibility to other antibiotics. The experiences of treatments for a RGM pulmonary infection with various antibiotics are also limited. This study evaluated the clinical manifestations, treatment, and the therapeutic outcomes of a RGM pulmonary infection. Subjects and method : Fifty-four cases with RGM from respiratory specimens were identified between November of 1996 and September of 2002 in the Asan medical center. The medical records and radiographic findings in 20 patients who fulfilled the diagnostic criteria of nontuberculous mycobacteria (NTM) pulmonary disease by ATS guidelines. The clinical, laboratory, and radiological parameters between subgroups. Results : Of the 20 patients, 15 were female. The mean age was 57.7 yrs (${\pm}7.5$), and all of the patients had a history of pulmonary tuberculosis. Most (90%) had an underlying lung disease. The majority of the isolates (80%) were M. abscessus. Chest radiography showed bilateral involvement in 80% of the patients. Bronchiectasis and multiple nodules were the main findings. Cavitation was present in 35% of the patients. Even though 70 % of the patients received antituberculous drugs prior to the correct diagnosis, all of the patients eventually received antibiotics. A mean of 3.5 antibiotics were given for an average of 439 days(${\pm}168$). After completing treatment, nine patients showed improvement after a mean 591(${\pm}311$) days of treatment, whereas the antibiotic treatment was unsuccessful in 2 patients. Conclusion : Many patients with a RGM pulmonary infection show an atypical pattern of radiological findings (bronchiectasis and multiple centrilobular nodules). It is very important to differentiate between M. tuberculosis and NTM and to identify the causative organisms among the NTM because a misdiagnosis can lead to an inappropriate and prolonged treatment. Combined antibiotic treatment yielded promising results, and is recommended for treating patients with a RGM pulmonary infection.

Clinical Characteristics of Tuberculosis in North Korean Refugees (북한이탈주민에서의 결핵의 임상적 고찰)

  • Choi, Chang-Min;Jeong, Woo-Kyoung;Kang, Cheol-In;Kim, Doh-Hyung;Kim, Young-Keun;Heo, Sang-Taek;Kim, Hee-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.3
    • /
    • pp.285-289
    • /
    • 2006
  • Background : North Korea's economic and public health problems began in the early 1990s as a result of the gradual loss of economic support from its communist allies, combined with an inordinate number of natural disasters. The decline in public health has increased the incidence of tuberculosis in North Koreans and refugees. This study investigated tuberculosis situation in North Korean refugees in order to prepare for the future impact of tuberculosis control in Korea. Material and Methods : From 2001 to 2005, tuberculosis patients among North Korean refugees who were diagnosed before or after arriving in South Korea, based on the official records of OO hospital, were enrolled in this study. The demographic and clinical data of the cases were evaluated retrospectively. Results : A total of 42 TB cases were reviewed during the study period. Of these, 37 (88.1%) cases were pulmonary TB. based on the cases identified among the number of North Korean refugees' arriving each year, the annual incidence of pulmonary TB were 900 per 100,000 in 2004, 700 in 2003, The number of smear-positive patients was 20 (47.6%) and the number of culture-positive patients was 18 (42.9%). Of the M. tuberculosis isolates, 2 cases were found to be susceptible to all anti-TB drugs available, 4 were resistant to isoniazid, and 3 were multi-drug resistant. Conclusion : The prevalence of pulmonary TB in North Korean Refugees is high. In addition, North Korean refugees suffer from more severe tuberculosis in bacteriological and radiological aspects.

Usefulness of the Pleural Fluid Adenosine Deaminase with Lymphocyte/Neutrophil Ratio in the Diagnosis of Tuberculous Pleurisy for a Region of Intermediate Prevalence of Tuberculosis (중등도 결핵 유병률 지역에서 결핵성흉막염 진단에 있어 흉수 아데노신 탈아미노효소와 림프구/호중구 비의 유용성)

  • Kim, Chang Hwan;Mo, Eun Kyung;Park, Sung Hoon;Hwang, Yong Il;Jang, Seung Hun;Park, Yong Bum;Kim, Cheol Hong;Kim, Dong-Gyu;Lee, Myung Goo;Hyun, In Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.6
    • /
    • pp.437-443
    • /
    • 2009
  • Background: The aim of this study was to consider the significance of pleural fluid adenosine deaminase (ADA) activity combined with lymphocyte/neutrophil (L/N) ratio in the diagnosis of tuberculous pleurisy (TBpl) in a region of intermediate prevalence of tuberculosis (TB). Methods: We collected data from 388 patients with exudative pleural effusions. The final diagnoses were compared to the results from our diagnostic method using pleural fluid ADA and L/N ratio. Results: 108 patients had a final diagnosis of TBpl; 102 cases had high levels of ADA ($\geq$40 IU/L). When we considered ADA $\geq$40 IU/L as a diagnostic criterion, the sensitivity was 94.4%, specificity 87.5%, and posttest posttest probability 74.5%. However, when we considered ADA $\geq$40 IU/L combined with the L/N ratio $\geq$0.75 as a diagnostic criterion, the specificity and post-test probability were rose to 97.5% and 93%, respectively. The other causes of high ADA and L/N ratios were lymphoma and metastatic carcinoma, but mass-like lesions were found on the chest radiographs or CT scans. Conclusion: To evaluate the causes of exudative pleural effusions in a region of intermediate prevalence of tuberculosis, we recommend measuring the pleural fluid ADA and L/N ratio first. If the result is high and malignancies are not suspected, it may be diagnostic of TBpl.

A Case of Pulmonary Paragonimiasis with Recurrent Pleural Effusion and Cured by Four Cycles of Chemotherapy (세 차례 재발하여 4회 약물 요법으로 치료한 폐흡충증 1예)

  • Cho, Gye Jung;Lim, Jung Hwan;Chae, Dong Ryeol;Chi, Su Young;Ban, Hee Jung;Yoon, Byeong Kab;Kwon, Yong Soo;Oh, In Jae;Kim, Kyu Sik;Kim, Yu Il;Lim, Sung Chul;Kim, Young Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.6
    • /
    • pp.451-456
    • /
    • 2009
  • Paragonimiasis is a parasitic infection that occurs following the ingestion of infectious Paragonimus metacercariae, which occurs as a result of eating raw or undercooked freshwater crabs or crayfish. Pulmonary paragonimiasis is the most common clinical manifestation of this infection. Human paragonimiasis occurs sporadically. We experienced a case of pulmonary paragonimiasis in a 35-year-old woman with left lower chest pain. The patient had hypereosinophilia and a pleural effusion. The diagnosis was confirmed by positive ELISA (Enzyme-linked immunosorbent assay) that detected Paragonimiasis westermani antibody in the serum. We treated the patient with praziquantel for two days at a daily dosage of 75 mg/kg. Left pleuritic pain and pleural effusion improved after treatment. However, similar symptoms and pleural effusion developed recurrently for the first 3 courses of treatment with praziquantel. Upon the fourth round of treatment, the patient made a full recovery.

Clinical Features of Patients with Lung Cancer and Upper Aerodigestive Tract Cancer (폐암과 상부소화호흡기암이 동반된 환자의 경우 임상적 특징)

  • Lee, Chang Youl;Chung, Jae Hee;Chang, Yoon Soo;Kim, Se Kyu;Kim, Hyung Jung;Chang, Joon;Kim, Sung Kyu;Ahn, Chul Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.4
    • /
    • pp.284-289
    • /
    • 2007
  • Background: To define the clinical features of patients with lung and upper aerodigestive tract cancer through a review of the histopathology, clinical features and follow-up results. Methods: Patients with lung and upper aerodigestive tract cancer who were diagnosed in Young dong Severance Hospital from 1992 to 2005, were retrospectively reviewed. The clinical data, radiologic findings, pathologic findings, treatment modalities were evaluated. Result: There was a total of 20 patients with aerodigestive tract cancer who were diagnosed with lung cancer over a 13 years period. The mean age was $58.45{\pm}15.09$ years and 19 cases were male. There were 14 smokers with an average pack year of 46 years. Twelve patients had aerodigestive tract cancer and later developed lung cancer, and 5 lung cancer patients were later diagnosed with aerodigestive tract cancer. Conclusion: These results suggest that cancers of the aerodigestive tract and lung can arise as either dependent or independent events and most aerodigestive tract cancer patients who developed lung cancer are not treated properly. Therefore, regular low dose chest CT with close suspicion is needed to properly manage upper aerodigestive tract cancer patients.

A Study on the Variation of Transmission Factors, Output Factors and Percent Depth Doses by Wedge Filters for 4~10 MV X-Ray Beams (4~10 MV X-선의 쐐기 (wedge) 필터의 투과율과 출력계수, 선축상 선량분포의 변화에 관한 연구)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1997
  • Because a wedged beam consists of attenuated primary photons and scattered radiations from wedge, the spectrum of the wedged beam does not coincide with that of an open beam with same geometry. The aims of current report are to get exact information about whether effects of 15-60$^{\circ}$ wedge for 4 -10 MV photon beams should be considered for dose calculation or not, and to suggest a reference condition for measurement of wedge transmission factor. Percent depth dose of both open and wedged fields with angles of 15, 30, 45, 60$^{\circ}$ for beams of 4 MV(Clinac 4/100, Varian), two 6 MV(Clinac 6/100 and Clinac 2100C, Varian), 10 MV(Clinac 2100C, Varian) X-rays were measured to 30cm deep in water using ionization chambers. Hardening factors of photon beams were calculated with measured PDDs. Both field size factors and transmission factors of wedge filters were measured at d$_{max}$ in water. Beam hardening factors of wedged fields of 4 and 6 MV X-ray were larger than 1 for all wedge angles, field sizes and depths deeper than d$_{max}$ Beam hardening factors for wedge angles 15, 30, 45, 60$^{\circ}$ for 10$\times$10cm were respectively 1.010, 1.014, 1.023 and 1.034 for 4MV X-ray, 1.005, 1.008, 1.019, and 1.024 for 6MV X-ray of Clinac 6/100, 1.011, 1.021, 1.032, 1.036 for 6MV X-ray of Clinac 2100C, and 1.008, 1.012, 1.012 and 1.012 for 10MV X-ray. Beam hardening factors of 10MV X-ray were 1 within 1.2% difference for all wedge angles, depths and field sizes. It was made clear that for 6MV X-rays, the beam hardening factor depends on treatment machine. The relationship of the factor and depth was linear. Field size factor at d$_{max}$ was independent of wedge angle except for the field of 15$\times$15cm. and maximum difference of the field size factors for the field size was 1.4% for 4MV X-ray. When the wedge factor is determined, dependence of the factor on field size is negligible at d$_{max}$ but should be considered at deeper depth. Calculating dose distribution or MU, the beam hardening factor should be applied for 4~6MV X-ray beams, but might not be considered for 10MV beam. When wedge transmission factor was determined at d$_{max}$ or in air, field size factors for open field are also applicable to wedged fields, but otherwise, field size factor for each wedge or wedge factor depending on field size should be applied.

  • PDF

Development of Manual Multi-Leaf Collimator for Proton Therapy in National Cancer Center (국립암센터의 양성자 치료를 위한 수동형 다엽 콜리메이터 개발)

  • Lee, Nuri;Kim, Tae Yoon;Kang, Dong Yun;Choi, Jae Hyock;Jeong, Jong Hwi;Shin, Dongho;Lim, Young Kyung;Park, Jeonghoon;Kim, Tae Hyun;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • Multi-leaf collimator (MLC) systems are frequently used to deliver photon-based radiation, and allow conformal shaping of treatment beams. Many proton beam centers currently make use of aperture and snout systems, which involve use of a snout to shape and focus the proton beam, a brass aperture to modify field shape, and an acrylic compensator to modulate depth. However, it needs a lot of time and cost of preparing treatment, therefore, we developed the manual MLC for solving this problem. This study was carried out with the intent of designing an MLC system as an alternative to an aperture block system. Radio-activation and dose due to primary proton beam leakage and the presence of secondary neutrons were taken into account during these iterations. Analytical calculations were used to study the effects of leaf material on activation. We have fabricated tray model for adoption with a wobbling snout ($30{\times}40cm^2$) system which used uniform scanning beam. We designed the manual MLC and tray and can reduce the cost and time for treatment. After leakage test of new tray, we upgrade the tray with brass and made the safety tool. First, we have tested the radio-activation with usually brass and new brass for new manual MLC. It shows similar behavior and decay trend. In addition, we have measured the leakage test of a gantry with new tray and MLC tray, while we exposed the high energy with full modulation process on film dosimetry. The radiation leakage is less than 1%. From these results, we have developed the design of the tray and upgrade for safety. Through the radio-activation behavior, we figure out the proton beam leakage level of safety, where there detects the secondary particle, including neutron. After developing new design of the tray, it will be able to reduce the time and cost of proton treatment. Finally, we have applied in clinic test with original brass aperture and manual MLC and calculated the gamma index, 99.74% between them.

Evaluation of 3DVH Software for the Patient Dose Analysis in TomoTherapy (토모테라피 환자 치료 선량 분석을 위한 3DVH 프로그램 평가)

  • Song, Ju-Young;Kim, Yong-Hyeob;Jeong, Jae-Uk;Yoon, Mee Sun;Ahn, Sung-Ja;Chung, Woong-Ki;Nam, Taek-Keun
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.201-207
    • /
    • 2015
  • The new function of 3DVH software for dose calculation inside the patient undergoing TomoTherapy treatment by applying the measured data obtained by ArcCHECK was recently released. In this study, the dosimetric accuracy of 3DVH for the TomoTherapy DQA process was evaluated by the comparison of measured dose distribution with the dose calculated using 3DVH. The 2D diode detector array MapCHECK phantom was used for the TomoTherapy planning of virtual patient and for the measurement of the compared dose. The average pass rate of gamma evaluation between the measured dose in the MapCHECK phantom and the recalculated dose in 3DVH was $92.6{\pm}3.5%$, and the error was greater than the average pass rate, $99.0{\pm}1.2%$, in the gamma evaluation results with the dose calculated in TomoTherapy planning system. The error was also greater than that in the gamma evaluation results in the RapidArc analysis, which showed the average pass rate of $99.3{\pm}0.9%$. The evaluated accuracy of 3DVH software for TomoTherapy DQA process in this study seemed to have some uncertainty for the clinical use. It is recommended to perform a proper analysis before using the 3DVH software for dose recalculation of the patient in the TomoTherapy DQA process considering the initial application stage in clinical use.

Assessment on Gastrointestinal Transit Movement of Capsule Endoscopy in Beagle Dogs (비글견에서 캡슐 내시경의 위장관 이동분석 평가)

  • Chang, Hwa-Seok;Yang, Hee-Taek;Kim, Sang-Youn;Woo, Dong-Cheol;Park, Woo-Dae;Yong, Joon-Hwan;Choe, Bo-Young;Kim, Hwi-Yool;Choi, Chi-Bong
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.125-130
    • /
    • 2008
  • The object of this study is to measure the transit time and passage rate of capsule endoscopy (CE) in the gastrointestinal tract in medium sized beagle dogs ($7{\sim}13\;kg$). Animals were divided into four groups: only capsule (group 1, n=10), capsule+water (group 2, n=10), mettoclopramide+capsule (group 3, n=10), metoclopramide +capsule+water (group 4, n=10). The capsule transit times through the stomach and small bowel were evaluated by radiography findings. Gastric transit time (GTT), small intestinal transit time (SITT) and complete passage rate were measured in four groups. GTT's for each group were as follows; $45{\pm}20\;min$ (group 1), $117{\pm}35\;min$ (group 2), $150{\pm}40\;min$ (group 3), and $154{\pm}65\;min$ (group 4), while SITT's were $75{\pm}20\;min$ (group 1), $195{\pm}55\;min$ (group 2), $70{\pm}15\;min$ (group 3), and $76{\pm}15\;min$ (group 4). The complete passage rates were 20% (group 1), 40% (group 2), 20% (group 3), 50% (group 4). In all groups, if CE could pass through the pylorus, it passed all small intestinal tracts within 8 hours (battery life). Administration of water helped CE to pass pylori, except in case of metoclopramide administration. These results indicate that CE could be an useful tool for examining gastrointestinal diseases in the veterinary medicine.

  • PDF

Accuracy Evaluation of Treatment Planning System Using Irregular-surface Water Phantom (요철 표면 팬텀을 이용한 치료계획시스템 선량계산 정확성 평가)

  • Jeong, Dong-Hyeok;Kim, Ki-Hwan;Lee, Kang-Kyoo;Moon, Sun-Rock;Kim, Jhin-Kee;Shin, Kyo-Chul;Oh, Young-Kee;Kim, Jeung-Kee;Cho, Moon-June;Kim, Jun-Sang
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.131-138
    • /
    • 2008
  • We evaluated on the calculation accuracy of treatment planning system (TPS) with phantom having convex and concave surface. The TPS is Eclipse (Varian, USA) using both algorithms AAA and PBC for photon dose calculations. PBC algorithms have three corrections of Batho, modified Batho (M-Batho), and equivalent TAR (E-TAR). The field sizes were $10{\times}10\;cm^2$ and $20{\times}20\;cm^2$, and MLC-shaped fields for these fields. We measured doses at three depths 5, 10 and 15cm in phantom of SSD=90cm in the condition of inserted farmer chamber. For given conditions, we have calculated dose with these algorithms and compared them with measured doses. In AAA the calculated doses (dose/MU) were agreed to measured doses within ${\pm}1%$ in flat and convex surface and were under estimated with -1.9% maximum in concave surface. In PBC the calculated doses were over estimated with +1.7% and +4.1% respectively in flat and convex surface and the differences were from -3.1% to +2.1% in concave surface. In comparison of criteria from AAPM and IAEA reports, and statistical analysis for these results, it is found that the AAA's results are in good agreement with measured values and the M-Batho's results are generally good agreed with measured values among PBC algorithms.

  • PDF