• Title/Summary/Keyword: 방사선학적 평가

Search Result 772, Processing Time 0.029 seconds

Evaluation of Image Quality for Radiographic Positioning using IEC Radiation Quality in the Digital Radiography System (디지털방사선시스템에서 IEC표준을 이용한 방사선 영상 품질의 평가)

  • An, Hyeon;Kim, Changsoo;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.289-299
    • /
    • 2015
  • The purpose of this study is to evaluate and compare the quality of digital X-ray imaging system. The image quality evaluation was conducted By using Modulation transfer function indicating the quantitative resolution of the image and the noise power spectrum showing the noise characteristics. Using a IEC61267 radiation quality was applied to the geometry to be used in clinical and geometry presented in IEC62220-1 and Additional filter, grid, the clinical dose and the MTF value of edge phantom was measured. Result of the MTF corresponding to each item(Grid, Filter, SID, kVp, mAs), the clinical condition 100cm, 180cm, measurements of the spatial frequency of the MTF IEC62220-1Geometry 150cm became similarly apparent, rather spatial frequency was also the case high in clinical conditions 100cm. NPS results, as the dose(mAs) is increased, NPS showed that reduced. The image quality evaluation using IEC61267 the Radiation quality, Image quality of the video using the clinical conditions Geometry than image quality evaluation using IEC62220-1Geometry was better. It shows that MTF and NPC in IEC and clinical condition were not significantly different. In order to apply the evaluation method of image quality applied with clinical conditions rather than the future method, to be presented evaluation of IEC standard, based on the results of the image characterization studies in this paper, the methods that shows good quality of spatial resolution and decrease NPS value as the least dose, used suitable parameters for whether or not using added filter, grid, change SID and clinical quality(kVp), dose(mAs) etc should be found. then It is believed to be able to properly maintain the actual quality of the image of the digital radiographic imaging system in clinical.

Evaluation of Prosthetic Reconstruction in Lower Extremity (하지 골 종양에서 종양 대치물을 이용한 사지 구제술의 평가)

  • Lee, Sang-Hoon;Oh, Joo-Han;Yoo, Kwang-Hyun;Suh, Sung-Wook;Koo, Ki-Hyoung;Kim, Han-Soo;Lim, Soo-Taek
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.8 no.1
    • /
    • pp.1-11
    • /
    • 2002
  • Purpose : We evaluated the radiological and functional results of prosthetic reconstruction for locally aggressive benign and malignant tumor in the lower extremity. Materials and Methods : Eighty eight patients were followed up for an average 76 months(22~174). We examined the survival rate of prosthesis, and evaluated the final result by MSTS functional score and ISOLS radiological implants evaluation system. They were statistically analyzed according to the age(<20 year vs. ${\geq}$20 year), fixation methods, amount of bony resection, chemotherapy, local recurrence, and presence of metastasis. Results : The 5 year prosthetic survival rates were 100% in the proximal femur, 83.3% in the distal femur, 81.9% in the proximal tibia. Mean total functional scores were 73.3%, 72%, 68.7%, respectively. In distal femur, the non-chemotherapeutic group was superior in the prosthetic survival rate. Recurrence or metastasis affected the functions in the distal femur and proximal tibia. In the radiological evaluation of the distal femur, older patients over 20 years of age and with cement fixation were superior in bone remodeling(p<0.05). Postoperative infection and radiological loosening were the main causes of the prosthetic failure. Conclusion : The prosthetic reconstruction in the lower extremity led to good clinical and radiological results. Amount of bony resection, chemotherapy, recurrence and metastasis seemed to influence the prosthetic survival, and long-term follow-up will be necessary to investigate more significant prognostic factors.

  • PDF

Radiologic Outcome of Beta-Tricalcium Phosphate as a Bone Substitute in Orthopaedic Surgery (정형외과 수술에서 골대체제로써 Beta-Tricalcium Phosphate 사용에 대한 방사선학적 결과)

  • Park, Hyungseok;Moon, Jeong Eun;Cho, Yong Jin
    • The Korean Journal of Health Service Management
    • /
    • v.13 no.4
    • /
    • pp.133-144
    • /
    • 2019
  • Objectives: To analyze the radiologic results of patients treated with bone defects treated with beta-tricalcium phostphate (β-TCP) in orthopedic surgery. Methods: Medical records of 49 patients, consisting of 24 (49.0%) men and 25 (51.0%) women were retrospectively reviewed. Graft incorporation was evaluated based on Irwin's radiologic staging. Results: The explanatory power of the total regression equation in Irwin's stage at 3 months postoperatively according to three explanatory variables, namely graft tightness, age at diagnosis, and lesion volume, was 65.6%; the explanatory power of Irwin's stage at 6 months postoperatively according to two variables, namely lesion volume and graft tightness, was 32.9%; and the explanatory power of Irwin's stage at 9 months postoperatively for two variables, namely longitudinal lesion length and graft tightness in the total regression, was 30.8%. Conclusions: Graft tightness, lesion volume, age at diagnosis, and longitudinal lesion length are the common factors affecting graft incorporation.

Gamma-ray-induced skin injury in the mini-pig: Effects of irradiation exposure on cyclooxygenase-2 expression in the skin (감마선조사에 의한 돼지 피부장애에 cyclooxygenase-2의 발현변화)

  • Kim, Joong Sun;Park, Sunhoo;Jang, Won Seok;Lee, Sun Joo;Lee, Seung Sook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.65-72
    • /
    • 2015
  • The basic concepts of radiation-induced skin damage have been established, the biological mechanism has not been studied. In this study, we have examined the effects of gamma rays on skin injury and cyclooxygenase(COX)-2 expression. Gamma irradiation induced clinicopathological changes in a dose- and time-dependent manner in mini-pig skin. The histological changes were consistent with the changes in gross appearance at 12 weeks after irradiation. After three days' irradiation, apoptotic cells in the basal layer were found more frequently in irradiated skin than in normal skin, with the magnitude of the effect being dose-dependent. The thickness of the epidermis transiently increased 3 days after irradiation, and then gradually decreased, although changes in the epithelial thickness of the irradiated field were not observed with irradiation doses over 50 Gy. In the epithelium, there was an initial degenerative phase, during which the rate of basal cell depletion was dependent on the radiation dose (20-70 Gy). One week after irradiation, COX-2 expression was mostly limited to the basal cell layer and was scattered across these cells. High COX-2 expression was detected throughout the full depth of the skin after irradiation. The COX-2 protein is upregulated after irradiation in mini-pig skin. These histological changes associated with radiation exposure dose cause the increased COX-2 expression in a dose-dependent fashion.

Image Measurement on Influence from Application of Compression Band on Intravenous Urography for Urolithiasis Patient (요로결석 환자의 경정맥 요로조영 검사 시 압박 유무에 따른 영상평가)

  • Kim, Hyeong-Gyun;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.261-266
    • /
    • 2015
  • Intravenous urography (IVU) for urolithiasis is a radiologic examination to diagnosis stone in the ureter path using iodine contrast media, which is radioopacity material. The method includes compression on the upper iliac crest. The compression band prevents outlet of the contrast media through the bladder and enables easier movement to upper urinary tract. This usage depends on the policy of a hospital. Therefore, this study aimed to review and compare the characteristic of progress of contrast media either in compression and non-compression. The retrospective image measurement on 60 cases of intravenous pyelography was conducted at a hospital with the identical type and amount of contrast media as well as criteria for testing. Image measurement was limited to 5 minutes clip, which is optimal for progress of contrast media depending on usage of the compression band. Also, anatomical regions were set as following: "RP" is from renal pyramid to renal pelvis, "PL" is from renal pelvis to lumbar three endplate, and "IU" and "IL" for upper and lower parts from both iliac crests. Analysis has been conducted through the statistical method based on Fisher's Exact Test to find if there are differences of distribution with the anatomical regions with compression or no compression. It has been confirmed that there is no statistical significant difference as the video measurement on 30 cases of compression and non-compression group respectively resulted in P value of 0.580 from left and 0.711 from right (both 0.960). Therefore, it has been concluded that application of a compression band on an intravenous pyelography for urolithiasis patient does not meaningfully affect the progress of contrast media.

The Preliminarily Result of Radiologic Disappearance of the Calcific Material on One Time Ultrasonographic Assisted Needling (견관절의 석회화 건염에서 초음파 유도하 1회 주사요법에 의한 방사선학적 조기 소멸 정도에 대한 예비보고)

  • Yoo, Jae-Chul;Shon, Min-Soo;Koh, Kyoung-Hwan;Lim, Tae-Kang;Lee, Yeong-Seok
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose: The purpose of this study is to report the preliminarily result of the radiologic disappearance of the calcific material, regardless of the size, type or location, on one-time ultrasonographic (US) assisted needling for calcific tendinitis of the shoulder. Materials and Methods: From March to August 2011, 46 patients (47 shoulders) with symptomatic calcific tendinitis were treated by one-time US assisted needling. Initially, a diagnostic US was performed with patient to determine the locations, numbers and sizes of calcific deposits. After 1% lidocaine local anesthesia, the calcific material was punctured with an 18-gauge needle under US monitoring. If no calcific material was aspirated after 2 or 3 additional attempts, the deposits was performed multiple puncture to achieve decompression. And then all patients were performed subacromial corticosteroid injection. All patients were followed up 4 weeks after procedure. To assess the radiologic disappearance after one-time US assisted needling, simple radiographs of the treated shoulder were performed and size, dense, and morphology of the calcific deposits were compared with those in baseline radiographs. For clinical evaluations, visual analogue scale for pain and function (PVAS and FVAS), and American Shoulder and Elbow Surgeons (ASES) score were assessed. Results: There were 11 male and 35 female patients with the mean age of 53.8 years (28-71). The morphology of the calcific deposits were 31 type A and 16 type B by French Arthroscopic Society classification and mean size was $2.9{\pm}6.7$ mm before the procedure. At 4 weeks after the index procedure, the radiographic unchanged group was included in 10 cases and changed group was 37 cases. No intergroup difference for the clinical results after the procedure was evident, but group FAS classification before the procedure was significantly different (p=0.011). Conclusion: At 4 weeks after one-time US assisted needling for calcific tendinitis of the shoulder, the radiographic size- or dense-changed cases were showed in 79%, regardless of the size, type or location of the calcific material. But the radiographic nearly or complete disappearance were showed in only 21%.

  • PDF

Operative Treatment of Displaced Proximal Humerus Fractures with the Angular Stable Locking Compression Plate (각안정 잠김 압박 금속판을 이용한 전위된 근위 상완골 골절에 대한 수술적 치료)

  • Kim, Dong-Wook;Kim, Chong-Kwan;Jung, Sung-Won;Kim, Hyeon-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: We examined the clinical and radiological outcomes for displaced proximal humerus fractures that were treated with a PHILOS angular stable plate. Materials and Method: Forty four patients who underwent surgery between March 2007 and February 2010 were included in this study. All the cases were followed up for an average of 12 months. All the patients were examined and interviewed using the Visual Analog Scale (VAS) score, the Constant score and standardized X-rays to check the neck-shaft angle (NSA) and the presence of medial support. Results: The average Visual Analog Scale score was 2.8 points and the average Constant score was 70.5 points. The average neck shaft angle was $122.5^{\circ}$ and this was statistically significant between the good result group and the poor result group. There were 36 cases of the presence of medial support and 8 cases of the absence of medial support and the difference was statistically significant. Complications such as fixation failure happened in 12 cases. Conclusion: PHILOS angular stable plate fixation as an operative treatment for displaced proximal humerus fractures is a good and reliable treatment option.

GEOMETRIC CORRECTION OF RADIOGRAPHIC IMAGES USING GENERAL PURPOSE IMAGE PROCESSING PROGRAM (일반 영상처리 프로그램을 이용한 방사선사진의 기하학적 보정에 관한 연구)

  • Cheong Ji-Seong;Kim Eun-Kyung;Lee Sang-Hoon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.371-379
    • /
    • 1994
  • 본 연구는 비규격화시켜 촬영한 두장의 방사선 사진을 일반 영상처리 프로그램으로 기하학적 보정을 하여 디지탈 공제 촬영술을 시행한 결과를 개인별로 제작된 필름유지장치를 이용하여 규격화 시켜 촬영한 두장의 방사선사진을 디지탈 공제 촬영술을 시행한 결과와 비교하여 일반 영상처리 프로그램의 임상적 유용성을 평가해보고자 시행하였다. 19명의 자원자를 대상으로 하여, 각 환자에서 4매의 하악구치부 치근단 사진을 촬영하였다. 그중 2매는 XCP 필름 유지장치만으로 평행촬영법으로 촬영하였고, 나머지 2매는 교합제에 인상재를 부가하여 개인별로 제작된 XCP필름 유지장치를 이용하여 표준화시켜 역시 평행촬영법으로 촬영하였다. 기하학적 보정은 "Adobe Photoshop"과 "NIH Image" 프로그램으로 시행하였다. 특히 "Adobe Photoshop"의 임의영상회전 기능과 "IH Image"의 공제시술시 중첩된 사진을 투명하게 보여주는 기능, 병진기능을 활용하였다. 두 사진의 유사성을 측정하기 위해 공제된 사진의 계조도의 표준편차를 구하였다. 표준화군의 평균 표준편차가 기하학적 보정군의 평균 표준편차보다 약간 낮았으나, 통계적으로 유의성이 있는 차이를 보이지는 않았다. 위의 결과로 미루어보아, 하악구치부 에서 XCP필름 유지장치로 평행촬영한 비표준화방사선사진을 "Adobe Photoshop"과 "NIH Image" 프로그램을 이용하여 기하학적 보정을 할 수 있으리라 사료된다.

  • PDF