• Title/Summary/Keyword: 방사선학적 평가

Search Result 772, Processing Time 0.02 seconds

Evaluation of Stability using Monte Carlo Simulation in 2 People Isolation Treatment Room of Radiation Iodine (몬테카를로 모의 모사를 이용한 방사성옥소 2인 치료병실의 안전성 평가)

  • Jang, Dong-Gun;Ko, Sung-Jin;Kim, Chang-Soo;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.385-390
    • /
    • 2016
  • Radioactive iodine treatment that uses the 2 people isolation room is to cause unnecessary radiation exposure between patients. This research is to be tested safety of 2 people Isolation treatment room and dose-rate through conservative perspective except physiology characteristic and biology information on the assumption that patient have iodine without excretion in 2 people isolation treatment room. This research shows that 364 keV gamma rays emitted by the radioiodine was to determine that the air layer about 30 cm or lead shield 3 mm a half-layer. In addition, In addition, patients in the distance, and lead shielding, length of hospital stay (48 hours) for external radiation exposure that is received from the other patients, two of treatment as appears to be lower than the legal isolation standard dose less than 5 mSv isolation room effective analyzed that manageable.

The Quality and Thermoluminescence Properties of Dried Pollack during Storage Following Irradiation (방사선 조사와 저장기간에 따른 북어의 품질 및 thermoluminescence 특성)

  • Noh, Jung-Eun;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.5
    • /
    • pp.711-716
    • /
    • 2004
  • Gamma irradiation was applied to dried pollack to improve its microbiological quality and evaluate quality stability of irradiated samples. Thermoluminescence (TL) properties of minerals separated from irradiated samples were measured for possible use in identifying irradiation treatment. Dried pollack was packaged in commercial unit (PVC film, 0.06 mm thickness) and stored at $15{\pm}1^{\circ}C$ for 6 months. Samples showed over $10^4\;CFU/g$ in total aerobic bacteria or yeasts&molds, which increased during storage, reaching $10^6-10^7\;CFU/g$ at 3rd month of storage. Irradiation at 3 kGy was effective for improving hygienic quality for 6 months, keeping microbial population under 20 CFU/g. Gamma irradiation at 3 kGy or less did not significantly influence physicochemical quality attributes, such as browning, TBA value, volatile basic nitrogen, trimethylamine, and sensory properties, whereas storage time remarkably induced quality changes of dried pollack. TL analysis was proved suitable for identifying irradiated from non-irradiated samples over 6 months of storage.

Radiographic Evaluation of Limb Bone Development in Miniature Porcine (미니돼지의 팔다리 뼈 성장에 대한 방사선학적 평가)

  • Chang, Jin-Hwa;Jung, Joo-Hyun;Choi, Min-Cheol
    • Journal of Life Science
    • /
    • v.17 no.10
    • /
    • pp.1315-1320
    • /
    • 2007
  • Epiphyseal development in the long bones was studied radiographically in minipigs. Radiographs of the proximal and distal epiphyses of humerus, radius, ulna, femur and tibia were obtained at 4, 8, 12, 20, 40, 48, 96 and 144 weeks of age in total 58 minipigs. The assessment of maturity process was made in accordance with the criteria proposed by Owada and Sutow. The secondary ossification centers developed rapidly from 4 weeks of age to 40 weeks of age, and gradually thereafter until 96 weeks of age. The earliest epiphyseal fusion was apparent in the proximal radius, proximal and distal femur at 96 weeks of age. The complete fusion of the epiphyseal line in the long bones was evident on 144 weeks of age and was observed in most long bones such as the proximal humerus, the proximal and distal ulna and the distal radius, and the proximal tibia in minipigs.

Study on Development of Acute Index Through Peripheral Blood Test in Total Body Irradiation Patients (방사선 전신조사 환자의 말초혈액 검사를 통한 급성장애 지표개발에 관한 연구)

  • Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.91-103
    • /
    • 2001
  • In those patients who underwent radiation therapy with 10 MV X-ray for bone marrow transfer, compared the effect of high dose irradiation on peripheral blood were investigated in randomly selecting 18 patients. thus, changes in the levels of peripheral blood (WBC, Seg. neutrophil, Lymphocyte, RBC, Hemoglobin, Hematocrit ratio, GOT, GPT) were observed for 25 days after irradiation with the peripheral blood levels before irradiation in these patients and in 32 controls. Among changes in peripheral blood, the level of WBC was $8.63\%$ after radiation therapy with as much decrease as $0.22{\times}103{\pm}0.19{\times}103/mm^3$ compared with $2.51{\times}103{\pm}1.29{\times}103/mm^3$ before radiation therapy, and was only $6.35\%$ of $7.17{\times}103/mm^3{\pm}1.46{\times}103/mm^3$ in the controls, showing statistical significance (P<0.01, r2=0.9151). In the morphologic test of WBC, the level of Seg. neutrophil was decreased as much as to $20.53\%$ with $14.17{\pm}21.60\%$ compared with $69.00{\pm}25.60\%$ before irradiation, and decreased down to $24.39\%$ compared with $58.09{\pm}7.62\%$ in the controls (P<0.05, r2=0.6316). The number of lymphocyte increased as much as 3.94 folds at $79.91{\pm}27.30\%$ compared with $20.29{\pm}21.15\%$ before irradiation and was 2.39 times higher than $33.46{\pm}6.79\%$ in the controls (P<0.05, r2=0.7337). Although the change in the number of RBC was little with $3.18{\times}106{\pm}0.41{\times}106/mm^3$ before irradiation and $4.66{\times}106{\pm}0.43{\times}106/mm^3$ in the controls, no statistical significance was present (P>0.05). In addition, The number of hemoglobin was low compared with before irradiation and with the controls, but none showed statistical significance (P>0.05). Similarly, although the hematocrit ratio was low compared with before irradiation and with the controls, no statistical significance was present (P>0.05). In the values of the histologic examinations GOT and GPT, there is statistical significance between those from with before irradiation and with the controls (P<0.05). Thus, among peripheral blood, the number of WBC decreased drastically for a certain period after total body irradiation with high dose radiation, and the levels of Seg. neutriphil and lymphocyte decreased significantly after irradiation in the lymphocyte morphologic test. The results of the present study suggest that the possibility of developing the first to determine initially those patients who might develop radiation acute impairment using the usual peripheral blood test of patients to be exposed to high dose irradiation.

  • PDF

Postural Aberrations in Female Patients With Chronic Low Back Pain (만성요통 여성 환자들에서 발생되는 자세의 변화)

  • Oh, Duck-Won
    • Physical Therapy Korea
    • /
    • v.7 no.4
    • /
    • pp.1-7
    • /
    • 2000
  • 이 연구의 목적은 만성요통 여성 환자들에서 나타나는 자세 이상을 평가하고 방사선적 변수들과 임상적인 변수들과의 상관성을 알아보는 것이다. 이 연구의 대상자는 만성요통 여성 환자 38명과 대조군 32명이었다. 변수의 측정은 모든 대상자들이 이완된 자세로 기립한 상태에서 방사선 검사를 실시한 후 경추전만각, 흉추후만각, 요추전만각, 그리고 요추경사각을 측정하였다. 대상자들의 연령과 통증기간은 의무기록지를 참고하였다. 자료분석은 요통군과 대조군의 방사선적 변수들 간의 유의한 차이가 있는지를 알아보기 위해 독립된 t-검정을 시행하였고, 방사선적 변수들과 임상적 변수들과의 상관성을 알아보기 위해 피어슨 상관분석을 시행하였다. 연구결과 만성요통 환자군과 대조군사이의 경추전만각(p<.05), 요추전만각(p<.001), 그리고 천추경사각(p<.01)에서 통계학적으로 유의한 차이가 보였다. 통증기간은 요추전만각과 통계적학으로 유의한 상관관계가 있었으며(p<.05), 경추전만각은 흉추후만각과 통계학적으로 유의한 상관관계가 있었다(p<.05). 또한 흉추후만각, 요추전만각, 그리고 천추경사각은 각각 상호간에 상관관계가 있었다(p<.05). 만성요통은 요추만곡의 변화를 초래하여 흉추부 및 경추부의 자세이상을 유발할 수 있다. 그러므로 요통으로 인하여 올 수 있는 신체 전반적인 자세이상을 미리 예측하고 이를 교정하여야만 장기적으로 올 수 있는 합병증들을 예방할 수 있을 것이다.

  • PDF

Effect of Irradiation on the Quality Characteristics of Lyophilized Kimchi Powder (전자선 조사 동결건조 김치분말의 품질 특성)

  • Hong, S.P.;Kim, E.M.;Yang, J.N.;Ahn, D.U.
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.6
    • /
    • pp.614-618
    • /
    • 2007
  • The effect of irradiation on the quality characteristics of lyophilized kimchi powder was investigated in order to develop a commercial kimchi seasoning. Fresh and fermented kimchi powders were irradiated at 0, 1.5, 5, 10 and 30 kGy using a Linear Accelerator. By increasing the irradiation dose level, $a^*$ (redness) and $b^*$ (yellowness) values of the kimchi powders were decreased, while $L^*$ (lightness) value remained relatively unchanged as compared to the control. As the main volatile compounds, butanal, 2-butanone and acetic acid were produced in both of the kimchi powders at 30 kGy and dipropyl disulfide was detected only in the fermented kimchi. The viable counts of aerobic bacteria, yeasts, molds, and lactic acid bacteria in the kimchi powder were significantly reduced by all irradiation doses. However, aerobic and lactic acid bacteria were still observed in both of the kimchi powders at 30 kGy. No significant off-odors or off-tastes were produced in either of the kimchi powders by irradiation, while pungency decreased after irradiation. These results suggest that irradiated kimchi powder could be used as a kimchi seasoning.

A Rat Pylorus Stricture Model to Create Stent-induced Granulation Tissue Formation (백서 날문부에서 스텐트 유도 조직 과증식 형성을 위한 전임상 모델에 관한 연구)

  • Kim, Min-Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.559-565
    • /
    • 2022
  • In this study, we intend to develop a granulation tissue formation model. As a pilot experiment, a contrast agent was injected into the pylorus in 3 rats, the normal pylorus lumen size was confirmed, and a stent was placed. Stent migration was confirmed in to the duodenum within 1 week. In this experiment, stent was sutured and fixed to induce granulation tissue formation after gastrostomy under a fluoroscopic guidance. Twenty rats were divided into Healthy Group / Gastrostomy Group. After anesthesia of the Gastrostomy Group, an abdominal incision was performed, and gastrostomy was performed under a fluoroscopic guidance, and a stent was placed into the pylorus. In order to prevent stent migration due to peristalsis, suture between the pylorus and the proximal end of the stent was performed. Postoperative behavior and weight changes were monitored daily. Four weeks after surgery, gastrointestinal fluoroscopy imaging was performed and rats were sacrifices. To evaluate the degree of granulation formation, the stent was sectioned transversely. Gastrostomy group was statistically significantly higher than Healthy Group in granulation area ratio (all p<.001). In conclusion, it is considered that the level of tissue overgrowth formation for preclinical evaluation of the pylorus stricture model through gastrostomy is appropriate as a research evaluation tool.

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF

The Effect of Recombinant Human Epidermal Growth Factor on Cisplatin and Radiotherapy Induced Oral Mucositis in Mice (마우스에서 Cisplatin과 방사선조사로 유발된 구내염에 대한 재조합 표피성장인자의 효과)

  • Na, Jae-Boem;Kim, Hye-Jung;Chai, Gyu-Young;Lee, Sang-Wook;Lee, Kang-Kyoo;Chang, Ki-Churl;Choi, Byung-Ock;Jang, Hong-Seok;Jeong, Bea-Keon;Kang, Ki-Mun
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.242-248
    • /
    • 2007
  • Purpose: To study the effect of recombinant human epidermal growth factor (rhEGF) on oral mucositis induced by cisplatin and radiotherapy in a mouse model. Materials and Methods: Twenty-four ICR mice were divided into three groups-the normal control group, the no rhEGF group (treatment with cisplatin and radiation) and the rhEGF group (treatment with cisplatin, radiation and rhEGF). A model of mucositis induced by cisplatin and radiotherapy was established by injecting mice with cisplatin (10 mg/kg) on day 1 and with radiation exposure (5 Gy/day) to the head and neck on days $1{\sim}5$. rhEGF was administered subcutaneously on days -1 to 0 (1 mg/kg/day) and on days 3 to 5 (1 mg/kg/day). Evaluation included body weight, oral intake, and histology. Results: For the comparison of the change of body weight between the rhEGF group and the no rhEGF group, a statistically significant difference was observed in the rhEGF group for the 5 days after day 3 of. the experiment. The rhEGF group and no rhEGF group had reduced food intake until day 5 of the experiment, and then the mice demonstrated increased food intake after day 13 of the of experiment. When the histological examination was conducted on day 7 after treatment with cisplatin and radiation, the rhEGF group showed a focal cellular reaction in the epidermal layer of the mucosa, while the no rhEGF group did not show inflammation of the oral mucosa. Conclusion: These findings suggest that rhEGF has a potential to reduce the oral mucositis burden in mice after treatment with cisplatin and radiation. The optimal dose, number and timing of the administration of rhEGF require further investigation.

DETECTION OF PROXIMAL CARIES USING LASER FLUORESCENCE (레이저 형광법을 이용한 인접면 우식증 탐지효과)

  • Mo, Kyung-Hee;Yoon, Jung-Hoon;Kim, Su-Gwan;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.323-330
    • /
    • 2004
  • The purpose of this study was to evaluate the diagnostic validity of early proximal caries lesions using laser fluorescence and whether the detection could be enhanced using a fluorescent dye. Direct visual examination and bitewing radiograph were used for comparison. The subjects of this study were 30 children of $3{\sim}9$ years old. Laser fluorescence and dye-enhanced laser fluorescence(mixed wavelength of 488 and 514 nm) were used and viewed through glasses(excluding wavelength<520 nm). For dye-enhanced laser fluorescence a 0.075% sodium fluorescein dye was applied before examination. Proximal caries lesion of each subject was assessed using visual examination, bitewing radiograph, laser fluorescence, and dye-enhanced laser fluorescence. The results in the three detection methods were compared to the assessment of bitewing radiograph. The results from the present study can be summarized as follows: 1. There was highly correlation(r=0.725-0.911) between the bitewing radiograph and all three detection methods(p<0.05) 2. The reproducibility(kappa value) of the visual examination, laser fluorescence and dye-enhanced laser fluorescence comparing with bitewing radiograph of proximal caries was 0.451, 0.683, 0.772, respectively. There was highest correlation between dye-enhanced laser fluorescence and bitewing radiograph for detection of proximal caries. The results from this study indicated that the dye-enhanced laser fluorescence considered to be accurate and reliable method in detecting proximal caries.

  • PDF