• Title/Summary/Keyword: 방사선학적 평가

Search Result 772, Processing Time 0.03 seconds

Volumetric Estimation of the Prostate Gland using Computed Tomography in Normal Beagle Dogs (정상 비글견에서 컴퓨터단층촬영술을 이용한 전립선의 부피 평가)

  • Choi, Ji-Young;Choi, Soo-Young;Lee, Ki-Ja;Jeong, Woo-Chang;Han, Woo-Sok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.31 no.3
    • /
    • pp.175-179
    • /
    • 2014
  • The purpose of this study was to determine and compare prostate size using ultrasound and computed tomography (CT). The prostate gland was evaluated in eight normal Beagle dogs. Length, depth, and width of the prostate gland were measured by ultrasound and volume of the prostate was obtained from the two ellipsoid formula (US1, US2). Height, length, width, area, and volume of the prostate gland were measured by CT. Ratios of prostatic height, length, and width to the sixth lumbar vertebral body length were calculated. There was no significant difference between the US1 and US2 method, and between US2 and CT method, respectively. The prostatic volume calculated by US1 method was significantly lower than those with CT (p=0.029). The Upper limits of ratios of prostate length, height, and width to the length of the sixth lumbar vertebra were 1.3, 1.1, and 1.7, respectively. Among these prostate dimensions, prostate length and height could be a useful index in estimating prostate size regardless of body weight.

Comparison of Doses According to Change of Bladder Volume in Treatment of Prostate Cancer (전립선암 치료 시 방광의 용적 변화에 따른 선량의 비교 평가)

  • Kwon, Kyung-Tae;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.415-421
    • /
    • 2017
  • In the case of radiation therapy for prostate cancer, a balloon infused with a certain amount of air through the anus is used to reduce rectal dose. Because of the reason, radiation therapy for prostate cancer has acquired CBCT for daily image induction. In order to maintain the anatomical structure most similar to the first CT taken before treatment, it is pretreated, but it can not be said to be perfectly consistent. In two actual treatment regimens, the volume of the bladder was measured as 45.82 cc and 63.43 cc, and the equivalent diameter was 4.4 cm and 4.9 cm. As a result of this study, the mean volume of the bladder was estimated to be 56.2 cc, 105.6 cc by 20 CBCT. The mean dose of CBCT was 1.74% and the mean Bladder mean dose was 96.67%. In case B, PTV mean dose was 4.31%, Bladder mean Dose was estimated to be 97.35%. The changes in the volume of the bladder resulted in changes in the dose of PTV and bladder. The correlation coefficient of bladder dose according to the change of bladder volume showed linearity of mean dose $R^2=-0.94$. The correlation coefficient of the PTV dose according to the volume change of the bladder showed linearity of mean dose $R^2=0.04$. It was found that the dose change of PTV was larger than that of bladder according to the change of bladder volume.

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).

특수목적식품 제조용 프레스햄의 위생화를 위한 제조공정 단계별 감마선 조사기술 적용 : 미생물학적 평가

  • Byeon, Ui-Baek;Lee, Ju-Un;Kim, Jae-Hun;O, Sang-Hui;Seo, Ji-Hyeon;Kim, Jang-Ho;Byeon, Myeong-U
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2005.05a
    • /
    • pp.282-284
    • /
    • 2005
  • 본 연구는 특수목적식품을 개발하기 위한 대표적인 비가열 살균처리 기술인 방사선 살균기술을 이용하여 저장 중 프레스햄의 미생물학적 품질을 평가하고자 하였다. 그 결과 감마선비조사구의 경우 제조공정 단계에 관계없이 $30^{\circ}C$ 저장 4일 째에 모두 미생물 생육이 활발해져 장기저장에 부적합한 것으로 나타났으나, 감마선을 조사할 경우 훈연후 및 살균전 시료의 경우 5 kGy, 살균후 시료의 경우 3 kGy의 감마선 조사로 $30^{\circ}C$ 저장 4일 까지 미생물의 생육이 검출되지 않았다. 따라서, 감마선 조사기술은 프레스햄의 살균방법으로 이용이 가능하며, 특히 장기저장을 목적으로 하는 우주식, 환자식, 전투식량 등의 특수목적식품의 개발에 그 이용이 가능하다 할 수 있다.

  • PDF

Development of Human-Head-Mimicking Phantom for Brain Treatment Using Focused Ultrasound (집속 초음파 뇌 질환 치료를 위한 두부 유사 팬텀의 개발)

  • Min, Jeonghwa;Kim, Juyoung;Noh, Sicheol;Choi, Heungho
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.433-439
    • /
    • 2013
  • In this study, human head-mimicking phantom was developed for brain disease treatment study using focused ultrasound. Acoustic parameters of skin, skull and brain were investigated through literature investigation and adequate substitutes according to each tissue were suggested. In the case of skin phantom, construction ratio of glycerol-based TMM phantom was controlled to mimic real skin. The suitability of skull substitutes was evaluated through measurement of acoustic parameters. In the case of brain phantom, transparent egg white phantom was used to observe thermal properties of focused ultrasound. Combined human-head-mimicking phantom using each substitutes was fabricated for development of brain disease treatment protocol. Denaturation of brain phantom according to ultrasonic condition was observed for validation.

Functional Evaluation after Arthroscopic Reconstruction in Isolated and Combined Injury of Posterior Cruciate Ligament (후방십자인대의 단독 및 동반 손상에서 관절경적 재건술 후 기능적 평가)

  • Lee Kwang-Won;Lee Seung-Hun;Park Jae-Guk;Kim Ha-Yong;Kim Byung-Sung;Choy Won-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.115-120
    • /
    • 2002
  • Purpose : To compare the functional evaluation with the posterior translation after arthroscopic PCL reconstruction in isolated and combined PCL-deficient knees. Materials and Methods : We retrospectively evaluated 45 patients with PCL-deficient knees who were treated by arthroscopic PCL reconstruction using Achilles tendon allograft from June 1994 to June 2000. The differences of posterior translation were measured with posterior stress lateral radiographs and KT-2000 arthrometer. The functional results were evaluated using the Lysholm knee score and IKDC evaluation form. Results : Preoperative mean side to side differences of the posterior translation were 11.83 mm in isolated PCL-deficient knees and 12.7 mm in combined PCL-deficient knees respectively. At the last follow-up in isolated and combined PCL-deficient knees, the mean radiographic side to side differences of the posterior translation were 6.38 mm and 6.7 mm, the average corrected 20 Ib posterior displacements using KT-2000 arthrometer were 3.5 mm and 4.1 mm, the mean Lysholm score were 87.4 and 81.2, the grade A and B of IKDC evaluation form were 16 cases $(88.9\%)$ and 23 cases $(85.2\%)$, respectively. Conclusion : The functional results had no relationship with the degree of posterior translation after arthroscopic PCL reconstruction. Tendency of posterior translation may be influenced by associated injury of the knee.

  • PDF

A STUDY ON CEPHALOMETRIC EVALUATION OF MIXED DENTITION CHILDREN WITH NORMAL OCCLUSION (Ricketts 분석법에 의한 혼합치열기 정상교합 아동의 두부방사선계측학적 평가에 대한 연구)

  • Lee, Sang-Min;Jung, Tae-Ryun;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.248-261
    • /
    • 1999
  • In order to define a current set of Korean children norm with mixed dentition, following study was done. The subjects were 102 healthy dentition contestants(48boys, 54girls). Standardized lateral head roentgenograms were taken, and Ricketts analysis was done. Results were as follows: 1. Length of anterior cranial base, posterior facial height, corpus length were longer in male than in female(p<0.05), and Porion was located posteriorly in male than in female(p<0.01). 2. Through facial depth, Pogonion of male was more forwardly positioned(p<0.05), mandible was significantly steeper in female, and maxillary anterior teeth were significantly tipped forward in male(p<0.05). 3. Variables such as length of anterior cranial base, upper molar position(p<0.01) and corpus length(p<0.05) were significantly changed by age. 4. Maxillary height, facial depth, mandibular plane angle, convexity were changed by age, but not significantly(p>0.05).

  • PDF

Evaluation of mesiodistal tooth axis using a CBCT-generated panoramic view (CBCT-재구성 파노라마영상의 근원심 치축에 관한 연구)

  • Song, In-Tae;Cho, Jin-Hyoung;Chae, Jong-Moon;Chang, Na-Young
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.255-267
    • /
    • 2011
  • Objective: The purpose of this study was to confirm the reliability of a cone beam computed tomography (CBCT)-generated panoramic view based on a CBCT 3D image and to find the most helpful 2D panoramic image compared with CBCT 3D image when examining the mesiodistal tooth axis. Methods: A test model was constructed according to cephalometric norms. The test model was repeatedly repositioned for CBCT and panoramic radiographic imaging. Panoramic radiographs were acquired at each of the following 3 occlusal plane positions: $-5^{\circ}$, $0^{\circ}$, and $+5^{\circ}$. Measurements of mesiodistal tooth axis in CBCT 3D image, CBCT-generated panoramic view, and panoramic radiographs were compared. Results: Compared with the CBCT-generated panoramic view, CBCT 3D image showed significant difference in the mesiodistal tooth axis in the premolars and no significant difference in the mesiodistal tooth axis in the incisors and canines. Mesiodistal tooth axis on the CBCT-generated panoramic view was significantly different from that on panoramic radiographs. Conclusions: CBCT-generated panoramic view can be a useful tool for evaluating mesiodistal tooth axis.

Evaluation of the Surgical Treatment for Chronic Acromioclavicular Joint Injury; Weaver and Dunn Method Versus Acromial Bone Block Transfer (오구견봉인대만을 이용한 술식과 견봉골편을 포함한 오구견봉인대를 이용한 변형 Weaver and Dunn 술식에서의 만성 견봉쇄골관절 손상 치료결과 추시)

  • Park, Jin-Young;Kang, Seung-Wan;Lhee, Sang-Hoon;Seo, Jung-Bae;Lee, Seung-Jun
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.209-216
    • /
    • 2010
  • Purpose: The purpose of our study was to compare treatment results of two different surgical techniques for chronic acromioclavicular joint dislocations. Materials and Methods: Fifty consecutive patients diagnosed as chronic acromioclavicular joint dislocations between January 1997 and June 2009 were included in the study. Patients were randomized into two different groups. Patients in the first group (n=20) were treated using a modified Weaver and Dunn method using a simple coracoacromial ligament transfer method. Patients in the other group (n=30) were treated with acromial bone-block transfer containing coracoacromial ligament. Mean follow-up times for the two groups were 13.1 and 14.9 months, respectively. Results: At 1 year postoperatively, mean coracoclavicular distance, the VAS score and the ASES score for the Weaver-Dunn method group; for the bone block transfer method group were 3.8 mm (-3 to 6 mm), 3.5 (1.0 to 7.0) and 91.1 (81.66 to 95); 3 mm (-2 to 6 mm), 4.2 (1.0 to 7.5) and 79.6 (31.66 to 95). There were no significant differences in radiologic (p=0.377) and functional (p=0.093) results between the two groups. Failures in the former and latter group were, respectively, two and one. Conclusion: The bone block transfer method shows a tendency to maintain coracoclavicular distance and appeared to yield similar results as the modified Weaver Dunn method.

Coracoclavicular Ligament Augmentation Using Tight-Rope® for Acute Acromioclavicular Joint Dislocation - Preliminary Report - (Tight-Rope®을 이용한 급성 견봉 쇄골 관절 탈구의 치료 - 예비 보고 -)

  • Kweon, Seok Hyun;Choi, Sang Su;Lee, Seong In;Kim, Jeong Woo;Kim, Kwang Mee
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.115-122
    • /
    • 2013
  • Purpose: The purpose of this study is to analyze the results of acute acromioclavicular joint dislocation treatment with coracoclavicular ligament augmentation using Tight-Rope$^{(R)}$ (Arthrex). Materials and Methods: From October 2009 to March 2011, 30 patients with acute acromioclavicular joint dislocation underwent coracoclavicular ligament augmentation using Tight-Rope$^{(R)}$ and were followed up for at least 12 months after surgery. The radiologic results were qualified according to serial plain radiographs, and the clinical results according to University of California - Los Angeles (UCLA) Shoulder Scale, Constant score, and VAS pain score. Results: Using the UCLA scoring system, excellent results were observed in 22 cases (73%), good results in five cases (17%), fair results in two cases (7%), and a poor result in one case (3%). The average Constant score was $92.5{\pm}7.5$. According to radiologic results, anatomical reduction was achieved in 26 cases, and two cases showed a moderate loss of reduction, and two cases showed complete re-dislocation. Clinical results for patients with re-dislocation were unsatisfactory and reoperation was required. Conclusion: Coracoclavicular ligament augmentation using Tight-Rope$^{(R)}$ is a good option providing reliable functional results in patients with acute acromioclavicular joint dislocation.