• Title/Summary/Keyword: 방사선학적 관점

Search Result 23, Processing Time 0.025 seconds

Radiological Perspectives for Diagnosis of Vasospastic Angina with Coronary Angiography (이형성 협심증 진단 조영 검사의 방사선학적 관점)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.589-595
    • /
    • 2023
  • If complete coronary artery occlusion occurs due to severer coronary spasm, malignant arrhythmias can lead to death. Therefore, early screening for coronary artery spasm angina is essential. Among the test methods, the drug injection test through coronary angiography is generally performed. Therefore, the purpose of this study was to evaluate the advantages of ergonovine drug test for vasospasitc angina examination during coronary angiography, such as the relationship between the procedure time, contrast medium usage, and radiation exposure effects of coronary angiography. Follow-up data of 142 patients who underwent coronary angiography and variant angina examination from september 2021 to february 2023 were used. As a result of analyzing contrast usage dose and dose area product and air kerma dose and number of imaging series and procedure time, variant angina examination was statistically significantly higher than coronary angiography. (p<0.001) In conclusion, variant angina examination other than coronary artery angiography are radiologically negative. Therefore, we think it is better to avoid excessive inspection. Nevertheless, in the case of the provocation test, the longer the examination time, the higher the fluoroscopy time and the amount of contrast medium used, so it is better to conduct the test as quickly as possible or shorten it.

저선량 방사선 영향과 발현암의 인과성 문제

  • Lee, Jae-Gi
    • Radioisotope journal
    • /
    • v.15 no.3
    • /
    • pp.78-92
    • /
    • 2000
  • 낮은 선량의 방사선피폭으로 인한 건강 위해의 여부에 대하여 과학적 현황을 고찰하였다. 선량과 영향 사이에 문턱 없는 선형비례 모델(LN-T모델)에 대해 역학적, 수학적, 방사선생물학적 측면의 긍정적 논리와 호메시스, 적응반응, 통계적 관점의 비판적 논거를 대비하여 평가하였다. 방사선 피폭이력자에게 발현한 확률적 영향 특히 백혈병을 포함한 암에 대해 그 질환의 방사선 인과성 판단에 대한 애로와 접근 방향을 논의하였다. 객관적인 평가 지표의 하나로 기인확률(PC)을 적용하되 근로자에 대한 제도적 배려 등 고려할 사항을 논의하였다.

  • PDF

Paper Operration room nurses Experience in Using Radiation Suegery: Phenomenological Research (수술실 간호사의 방사선 노출 경험: 현상학적 연구)

  • Yun, Jae-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.426-438
    • /
    • 2020
  • This study aimed to identify the components of the nurses' exposure experiences and clarify the semantic structure of nurses by analyzing the participants' experiences of exposure to radiation. The participants in this study were nine nurses who worked for at least six months in the operating room of a City General Hospital. The data were collected using in-depth interviews and analyzed using the phenomenological method by Giorgi's (2004). As a result, six components were derived: "worrying about the disease by repeated radiation exposures", "exhausting physically and mentally," "trying to protect themselves against radiation exposure", "feeling of internal confusion and conflict", "demanding improvement of work environment", and "accepting and adapting to reality". In conclusion, nurses participating in radiation exposure surgery are concerned about the possibility of disease, experience physical and mental fatigue, and then consider changing their occupation. On the other hand, they try to accept and adapt to reality by considering the possibility of a job change or trying to protect themselves from the harsh environment. To develop a radiologically safe environment, systematic and effective resolutions must be secured at the organizational level.

Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR (표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가)

  • Kim, Sang-Tae;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2010
  • In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and digital radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Department of Radiology our hospital, a flat-panel DR equipment (Digital diagnost, Philips) and two CR systems (ADC Compact plus digitizer, AGFA) are employed. Eight standard radiographic examinations (Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.

Probabilities of Pulmonary and Cardiac Complications and Radiographic Parameters in Breast Cancer Radiotherapy (유방암의 방사선치료에서 방사선학적 지표에 따른 폐 및 심장의 부작용 확률)

  • Noh, O-Kyu;Park, Sung-Ho;Ahn, Seung-Do;Choi, Eun-Kyung;Lee, Sang-Wook;Song, Si-Yeol;Yoon, Sang-Min;Kim, Jong-Hoon
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.23-31
    • /
    • 2010
  • Purpose: To evaluate the relationship between the normal tissue complication probability (NTCP) of 3-dimensional (3-D) radiotherapy and the radiographic parameters of 2-dimensional (2-D) radiotherapy such as central lung distance (CLD) and maximal heart distance (MHD). Materials and Methods: We analyzed 110 patients who were treated with postoperative radiotherapy for breast cancer. A two-field tangential technique, a three-field technique, and the reverse hockey stick method were used. The radiation dose administered to whole breast or the chest wall was 50.4 Gy, whereas a 45 Gy was administered to the supraclavicular field. The NTCPs of the heart and lung were calculated by the modified Lyman model and the relative seriality model. Results: For all patients, the NTCPs of radiation-induced pneumonitis and cardiac mortality were 0.5% and 0.7%, respectively. The NTCP of radiation-induced pneumonitis was higher in patients treated with the reverse hockey stick method than in those treated by other two techniques (0.0%, 0.0%, 3.1%, p<0.001). The NTCP of radiation-induced pneumonitis increased with CLD. The NTCP of cardiac mortality increased with MHD ($R^2=0.808$). Conclusion: We found a close correlation between the NTCP of 3-D radiotherapy and 2-D radiographic parameters. Our results are useful to reanalyze the previous 2-D based clinical reports about breast radiation therapy complications as a viewpoint of NTCP.

CLEIDOCRANIAL DYSPLASIA : A PRELIMINARY REPORT (쇄골 두개골 이골증)

  • Kim, Il-Kyu;Ha, Soo-Yong;Lee, Seong-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.1
    • /
    • pp.69-76
    • /
    • 1991
  • A 9-year old boy suffering from cleidocranial dysplasia associated with impacted 4 supernumerary teeth and unerupted all permanent teeth is presented with his mother. The pedigree showed autosomal dominant pattern of inheritance, and the raiographic features of them were very similar in clavicle, skull, vertebrae, peivis and extremities. Although almost of the skeleton was involved with this syndrome, they did not recognize any other problem but except dental problem. In mother, who was wearing removable partial dentures leaving 24 impacted teeth in her jaws, the radiographic abnormalities like cystic lesion were not detected. And in the son, who showed impacted 4 supernumerary and all permanent teeth, we have attempted surgical extraction of the supernumerary teeth and periodic surgical opening of the alveolar bone covering the permanent dentition to induce the eruption of permanent teeth at the proper position, Orthodontic treatment has also been combined to correct class III malocclusion state.

  • PDF

Twenty Four Cases of Idiopathic Bronchiolitis Obliterans Organizing Pneumonia, Reported in Korea and a Review of Literatures (국내 보고된 특발성 폐쇄성세기관지염 기질화폐렴 24예와 문헌 고찰)

  • Chang, Jung-Hyun;Park, Sa-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.709-717
    • /
    • 1999
  • Background & Method : Bronchiolitis obliterans organizing pneumonia(BOOP) is a specific clinicopathologic condition characterized by chronic inflammatory interstitial infiltrates. Cryptogenic form of BOOP presents subacute clinical course of flu-like illness, such as cough, fever, dyspnea with exertion and other constitutional symptoms. Pathologically it shows the presence of granulation tissue filling the lumen of terminal and respiratory bronchioles, extending into distal airspaces. Recently, we reviewed 24 cases of idiopathic type of BOOP, 5 cases of our hospital and another 19 cases on Korean literatures, and compared with reviewed data from foreign literatures. Results : Mean age was 54 years old and there was female preponderance in domestic reports. Their common presenting symptoms were dyspnea and cough, and mean duration of illness was 41 days. On chest examination, inspiratory crackle was a common finding. The laboratory findings were nonspecific except hypoxemia. Lung function studies revealed restrictive defect or combined obstructive and restrictive pattern in most patients. Bilateral patchy and nonsegmental alveolar opacities constituted characterized radiographic finding, highlighted on high resolution computed tomogram. It showed a favorable prognosis with an excellent responsiveness to corticosteroid therapy. The clinical features and laboratory findings were similar between domestic and foreign cases except female preponderance in Korean cases. Conclusion : If the clinical course is atypical or pregressive under proper treatment, clinicians should reevaluate clinical features and radiographic findings under the consideration of BOOP. Tissue confirmation would be recommended for the definitive diagnosis of BOOP.

  • PDF

Evaluation of Stability using Monte Carlo Simulation in 2 People Isolation Treatment Room of Radiation Iodine (몬테카를로 모의 모사를 이용한 방사성옥소 2인 치료병실의 안전성 평가)

  • Jang, Dong-Gun;Ko, Sung-Jin;Kim, Chang-Soo;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.385-390
    • /
    • 2016
  • Radioactive iodine treatment that uses the 2 people isolation room is to cause unnecessary radiation exposure between patients. This research is to be tested safety of 2 people Isolation treatment room and dose-rate through conservative perspective except physiology characteristic and biology information on the assumption that patient have iodine without excretion in 2 people isolation treatment room. This research shows that 364 keV gamma rays emitted by the radioiodine was to determine that the air layer about 30 cm or lead shield 3 mm a half-layer. In addition, In addition, patients in the distance, and lead shielding, length of hospital stay (48 hours) for external radiation exposure that is received from the other patients, two of treatment as appears to be lower than the legal isolation standard dose less than 5 mSv isolation room effective analyzed that manageable.

Interstitial Radium Implantation and Cobalt-60 Irradiation of the Tongue Cancer (IbidI) (설암의 조직간내 라디움치료에 관하여)

  • 안경성;박주방;윤용규
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.16.1-16
    • /
    • 1972
  • In 1971 there were 5 cases of the tongue cancer in stage I & II treated concomitantly with interstitial radium implantation and Cobalt-60 irradiation at the Yonsei University Hospital Cancer Center. This is the interim report of the course of the primary site of those treated cases.

  • PDF

The Necessity of Resetting the Filter Criteria for the Minimization of Dose Creep in Digital Imaging Systems (디지털 영상 시스템에서 선량 크리프 최소화를 위한 부가 필터 두께 권고 기준의 재설정에 대한 연구)

  • Kim, Kyo Tae;Kim, Kum Bae;Kang, Sang Sik;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.757-763
    • /
    • 2019
  • Recently, Following the recent development of flat panel detector with wide dynamic ranges, increasing numbers of healthcare providers have begun to use digital radiography. As a result, filter thickness standards should be reestablished, as current clinical practice requires the use of thicknesses recommended by the National Council on Radiation Protection and Measurements, which are based on information, acquired using conventional analog systems. Here we investigated the possibility of minimizing dose creep and optimizing patient dose using Al filters in digital radiography. The use of thicker Al filters resulted in a maximum 19.3% reduction in the entrance skin exposure dose when medical images with similar sharpness values were compared. However, resolution, which is a critical factor in imaging, had a significant change of 1.01 lp/mm. This change in resolution is thought to be due to the increased amount of scattered rays generated from the object due to the X-ray beam hardening effect. The increase in the number of scattered rays was verified using the scattering degradation factor. However, the FPD, which has recently been developed and is widely used in various areas, has greater response to radiation than analog devices and has a wide dynamic range. Therefore, the FPD is expected to maintain an appropriate level of resolution corresponding to the increase in the scattered-ray content ratio, which depends on filter thickness. Use of the FPD is also expected to minimize dose creep by reducing the exposure dose.