• Title/Summary/Keyword: 방사선피폭

Search Result 1,257, Processing Time 0.039 seconds

Reducing Radiation Exposure Dose on Operator by Using Lateral Protection in Neuro-Intervention (뇌혈관 중재적시술에 있어 측방향 차폐체를 이용한 시술자 피폭 선량 저감화 방법 연구)

  • Kim, Jongdeok;Ahn, ByeoungJu;Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • The bi-plane cerebrovascular angiography radiation is done the radiation exposure at the forward and lateral direction as opposed to the one of the source. So, the exposure dose of radiation workers increases further. Therefore, the medical diagnostic radiation workers as well as patients is interested to ways to reduce the dose. The exposure dose of cerebral angiography and interventional radiology must be considered the primary radiation of X-ray tube directly, scattered primary radiation between lateral tube and lateral detector and relatively small secondary scatter radiation in the walls of room. The aim of study is that the exposure dose of primary and scatter radiation reduce as much as possible to install protection device of lateral protection than common shielding of table and ceiling. As a result, the dose of fluoroscopy was reduced approximately 3.64 times the gonads, thyroid approximately 3.13 times, 4.42 times around eyes. And the dose of DSA was reduced approximately 4.98 times the gonads, thyroid approximately 3.00 times, 1.67 times around eyes. Consequently, medical practitioners can be helpful for radiation dose-exposure for the lateral protection of bi-plane cerebrovascular angiography more than the common shield method in cerebrovascular angiography and interventional radiological procedures.

Patient exposure doses from medical x-ray examinations in Korea (진단방사선검사에서 환자피폭선량에 관한 연구)

  • Kim, You-Hyun;Choi, Jong-Hak;Kim, Sung-Soo;Oh, Yuw-Han;Lee, Chan-Hyeup;Cho, Pyong-Kon;Kang, Dae-Hyun;Lee, Young-Bae;Kim, Hyung-Chul;Kim, Chel-Min
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.241-248
    • /
    • 2005
  • X-ray examinations represent the largest man-made source of radiation exposure for the population. The need for standardization of radiation exposures has been suggested and the guidance levels for various radiographic and radioisotope examinations has been proposed by the International Atomic Energy Aency(IAEA) as a safety standard. In many countries, the situation of medical radiographic exposures in each country should be researched before the appropriate guidance level is established. In this study, measurements of entrance surface dose, dose-area product(DAP), computed tomograghic dose index(CTDI) and mean glandular dose(MGD) were carried out in patients who underwent routine x-ray examinations, fluoroscopy, computed tomograghy and mamography in Korea. These measured quantities were compared with the results from the calculation method in previous study. And we suggested diagnostic reference levels in medical imaging in Korea.

  • PDF

A Study on the Radiation Exposure Dose of Clinical Trainees in the Department of Radiology: A Case Study at C University Hospital (방사선(학)과 임상실습생의 수시출입자 피폭선량에 대한 고찰: C 대학병원 사례 연구)

  • Joo-Ah Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.249-255
    • /
    • 2023
  • In this study, radiation exposure doses were measured in the course of clinical practice of radiation workers, radiological technologists in the radiation-related worker group, and preliminary-radiological technologists who were classified as frequent visitors. Radiological technologists who worked in the radiation area of C University Hospital in Incheon for a year from January 2021 and 121 students who completed clinical practice at the same medical institution from July 1 to August 31 were the subjects of the study. The nominal risk factor based on ICRP 103 was used to evaluate the probability of side effects due to the exposure dose to the lungs, which are organs at risk of damage due to radiation exposure dose. During the clinical practice period, radiology students, who were classified as frequent visitors, had a surface dose of 0.98 ± 0.14 mSv and a deep dose of 0.93 ± 0.14 mSv. In other words, 6.7 per 1,000,000 for shallow dose and 6.4 per 1,000,000 for deep dose were found to have side effects due to exposure to the lungs. This is a value in terms of exposure dose in one year. Considering that the radiation (science) education course is 3 or 4 years, systematic management and attention to prospective radiation workers who are going to clinical practice are required, and the stochastic effect of radiation In relation to this, it is considered that it will be used as basic data for radiation safety management.

Evaluation on the Radiation Exposure of Radiation Workers in Proton Therapy (양성자 치료 시 방사선 작업 종사자에게 미치는 방사선 피폭에 대한 평가)

  • Lee, Seung-Hyun;Jang, Yo-Jong;Kim, Tae-Yoon;Jeong, Do-Hyung;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Purpose: Unlike the existing linear accelerator with photon, proton therapy produces a number of second radiation due to the kinds of nuclide including neutron that is produced from the interaction with matter, and more attention must be paid on the exposure level of radiation workers for this reason. Therefore, thermoluminescence dosimeter (TLD) that is being widely used to measure radiation was utilized to analyze the exposure level of the radiation workers and propose a basic data about the radiation exposure level during the proton therapy. Materials and Methods: The subjects were radiation workers who worked at the proton therapy center of National Cancer Center and TLD Badge was used to compare the measured data of exposure level. In order to check the dispersion of exposure dose on body parts from the second radiation coming out surrounding the beam line of proton, TLD (width and length: 3 mm each) was attached to on the body spots (lateral canthi, neck, nipples, umbilicus, back, wrists) and retained them for 8 working hours, and the average data was obtained after measuring them for 80 hours. Moreover, in order to look into the dispersion of spatial exposure in the treatment room, TLD was attached on the snout, PPS (Patient Positioning System), Pendant, block closet, DIPS (Digital Image Positioning System), Console, doors and measured its exposure dose level during the working hours per day. Results: As a result of measuring exposure level of TLD Badge of radiation workers, quarterly average was 0.174 mSv, yearly average was 0.543 mSv, and after measuring the exposure level of body spots, it showed that the highest exposed body spot was neck and the lowest exposed body spot was back (the middle point of a line connecting both scapula superior angles). Investigation into the spatial exposure according to the workers' movement revealed that the exposure level was highest near the snout and as the distance becomes distant, it went lower. Conclusion: Even a small amount of exposure will eventually increase cumulative dose and exposure dose on a specific body part can bring health risks if one works in a same location for a long period. Therefore, radiation workers must thoroughly manage exposure dose and try their best to minimize it according to ALARA (As Low As Reasonably Achievable) as the International Commission on Radiological Protection (ICRP) recommends.

  • PDF

Research on the Hematological Changes in Accordance with Radiation Dose and Radiation Exposure period of the Medical Radiation Workers (의료 방사선 종사자의 피폭기간 및 피폭선량과 혈액성분 변화에 대한 조사)

  • Cho, Jihwan;Jin, Seongjin;Park, Cheolwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.495-502
    • /
    • 2016
  • In this study, we analyzed the effects of radiation exposure, as compared to the hematological parameters change of medical radiation workers and the public. The mean value of all hematological parameters were in the normal range. Eosin mean value of the radiation workers($2.52{\pm}1.79%$) showed that a significantly lower than the control group($2.92{\pm}1.39%$). In the comparison of the results depending on the occupation period, it showed high value that the mean of the radiation workers group WBC, platelet, Lymph, Mono, Baso. Over 20 years of radiation workers WBC, Mono showed low values and less than 10 years of radiation workers mean value of Baso showed low values, there was no statistical significance. In the comparison of the results depending on the 4 years cumulative radiation dose, Over 5.0 mSv of Radiation works RBC($4.61{\pm}0.53$ vs $4.91{\pm}0.38$), Hct($41.51{\pm}4.07$ vs $43.97{\pm}3.40$), Eosin($1.74{\pm}1.14$ vs $2.92{\pm}1.39$) showed low value, it was statistical significance. 0.5~1.0 mSv radiation exposure workers Hb ($13.93{\pm}1.75$) showed a significantly lower value than that of the control group ($14.90{\pm}1.29$).

Radiation Exposure Dose on Persons Engaged in Radiation-related industries (방사선관계종사자의 피폭선량에 대한 연구)

  • Choi, Gui-Nam;Jeon, Ju-Seob;Kim, Yong-Wan
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.27-37
    • /
    • 2012
  • From Jan 2002 to June 2011, we evaluated 4419 cases of radiation dose of 323 radiation related individuals consist of physician, nurses, technician and others in local C national university hospital. On annual analysis, year 2003 ranked the highest and 2007 the lowest dose. Dose was relatively higher in male than female. Dose was highest in 30s on age basis analysis. Dose was high in order of physician, nurse, and technician. Average radiation dose was high in order of cardiovascular center, radiologic intervention ceter, radiologist individuals, and fluoroscopic contrast study room. Those doses did not excess the standard dose recommended by ICRP (20mSv/year). However unlike average dose, there are wide variations of dose in individuals. Therefore radiation related workers should do one's best in personal radiation exposure dose management for achievement of minimum dose of radiation.

Analysis of Radiation Dose for Lens, Thyroid Gland, Breast, and Gonad on Upper Gastrointestinal Series (위장조영검사에서 수정체, 갑상선, 유방, 생식선에 대한 피폭선량 분석)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.889-894
    • /
    • 2019
  • Upper gastrointestinal series is an examination that uses X-rays. It is important to defend against exposure to radiation during upper gastrointestinal examination because the organs, such as thyroid gland, lens, breasts, and gonads, with relatively high biological sensitivity to radiation are distributed on the examination area. We have made a whole body phantom that can change the depth of organs. radiation dose of eye, thyroid gland, breast and gonads were measured by the same procedure as the actual upper gastrointestinal examination. When performed only fluoroscopy the mean dose reduction of lens, thyroid gland, breast and gonads was 62.2%. The mean dose reduction of lens, thyroid gland, breast and gonads was 59.0% when both fluoroscopy and spot shoot were performed. Therefore, when performed upper gastrointestinal examination it was confirmed that shielding of the lens, thyroid gland, breast and gonads was effective in decreasing the exposure dose. The manufactured human phantom can be used in measuring radiation dose for deep organ because it can adjust the height corresponding to the organs located in the human body.

Analysis of Radiation Protection, Awareness and Attitude of Radiological Technologist in Mammography Room (유방촬영실에 근무하는 방사선사의 방사선 방어, 인식 및 태도에 관한 분석)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.557-565
    • /
    • 2017
  • This study was conducted to investigate the radiation protection, awareness, and attitude of radiological technologists in the mammography room due to the low energy use of breast imaging. Data collection was performed by 222 independent radiological technologists in the breast and breast clinic of six hospitals except Jeju Island. The independent sample t-test and oneway variance analysis were performed. As a result, it was found that the lower the number of men(p<0.05), the age of 30s(p<0.05), the marriage(p<0.05), the work experience of more than 10 years(p<0.05), the working hours of 8 hours(p<0.01), the less the impact of radiation(p<0.01), the more important it was to radiation defense. appear. This is thought to be influenced by the work specificity and work environment of the mammography room, and it will be used as a basic data to raise awareness and act on the exposure through analysis with other factors.