• Title/Summary/Keyword: 방사선치료 기법

Search Result 199, Processing Time 0.028 seconds

Total Hip Replacement in a Jindo Dog with Dorsal Acetabular Rim Deficiency: a Case Report (등쪽 관골절구 결손을 가진 진도견의 인공 대퇴 관절 전치환술)

  • Heo, Su-Young;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.31 no.2
    • /
    • pp.121-124
    • /
    • 2014
  • A 7-year-old, intact female Jindo dog was presented for assessment of weight-bearing lameness of the right hindlimb. On physical examination, crepitus and pain was noted in the right coxofemoral joint upon extension. Radiographs revealed a craniodorsal luxation of the right coxofemoral joint and degenerative joint disease (DJD) of both coxofemoral joints. Total hip replacement (THR) was performed for the right coxofemoral joint. Intraoperatively, dorsal acetabular rim (DAR) deficiency was noted, which can be related to a high risk for acetabular cup implant dislocation. Deficiency of the dorsal acetabular rim realigned with the acetabular cup using universal locking plate (ULP) and polymethylmethacrylate (PMMA) bone cement. After surgery, the patient had an uneventful course and a successful outcome. The ROM and thigh girth were dramatically improved. There were no complications associated with prosthesis implants. Hip luxation with dorsal acetabular rim deficiency in a dog was successfully repaired with THR and dorsal acetabular rim augmentation using ULP and PMMA bone cement. This technique should be considered when conventional THR is precluded by dorsal acetabular rim deficiency.

A CEPHALOMETRIC EVALAUATION OF ANTERIOR OPENBITE MALOCCLUSIONS TREATED BY MULTILOOP EDGEWISE ARCHWIRE TECHNIQUE (Multiloop edgewise Archwire 기법으로 치료된 전치 개교 증례의 두부방사선사진 계측학적 평가)

  • Moon, Seong-Cheol;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.23 no.4 s.43
    • /
    • pp.565-606
    • /
    • 1993
  • The purpose of this study was to evaluate the change of before and after treatment of anterior openbite malocclusions treated by Multiloop Edgewise Archwire technique. The openbite sample consisted of 4 male and 12 female adults, treated with nonextraction or third molar extraction. The normal sample consisted of 58 subjects, which have pleasing facial profile and normal occlusion and no experience of orthodontic or prosthodontic treatment. The 58 subjects of normal sample were subdivided by cephalemetric vertical relationship of face. The 40 subjects, cephalometric vertical relationship of face was in normal range, classified as Normal Sample group 1. The 18 subjects, increased cephalometric vertical relationship of face, classified as Normal Sample group 2. The computerized cephalometric analysis was accomplished with 50 reference points for 22 skeletal measurements, 46 dentoalveolar measurements, 8 soft tissue measurements. Statistical analysis of the data was carried out with paired t-test, Student's t-test, and DUNCAN test using SAS(PC version), The results were as follows : 1. There were no statistically significant differences in skeletal measurement between before and after treatment. The major changes were in dentoalveolar region. 2. After treatment, the long axis of maxillary and mandibular posterior teeth were distally tipped-back, and uprighted to bisected occlusal plane. The interincisal angle was increased. 3. There were no statistically significant increase in the upper posterior dental height and statistically significant decrease in the lower posterior dental height. The upper anterior dental height was increased, but there was no statistically significant increase in the absolute upper anterior dental hight. The lower anterior dental height was increased. 4. After treatment, the maxillary occlusal plane to palatal plane angle and the mandibular occlusal plane to mandibular plane angle were statistically significant increased. Then, there were no statistically significant difference between after treatment group and normal sample group 2. 5. After treatment, the percentage of upper lip length to upper anterior dental height was decreased. Then, There were no statistically significant difference between after treatment group and normal sample group 2.

  • PDF

A study on the tumor induced microvasculature using hyperspectral imaging system (초분광 이미징 시스템을 이용한 암 혈관 분석에 대한 연구)

  • Choe, Se-woon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.622-624
    • /
    • 2015
  • Tumor hypoxia caused by the unique characteristics of solid tumor sites such as lowered vascular density, irregular vasculature, longitudinal oxygen gradient, and unbalanced oxygen consumption has decreased therapeutic efficacy in several clinical trials such as radiation, chemotherapy, and surgery. Hence, tumor oxygenation studies at microvascular levels are important to provide better understanding of the complexity of microvasculature oxygen transport and exchange with tissue. However, polarographic microelectodes, was employed to measure $pO_2$ at the microvasculature level, but it is difficult to perform and does not provide significant spatial and temporal information of oxygen delivery. In this research, we introduce the hyperspectral imaging system able to provide a wide range of vascular characteristics by spatial maps on hemoglobin saturation information for better understanding of the relationship between blood oxygen delivery, hypervascularity, aberrant angiogenesis at microvasculature levels during tumor growth.

  • PDF

A Study of Optimized MRI Parameters for Polymer Gel Dosimetry (중합체 겔 선량측정법을 위한 최적의 자기공명영상 변수에 관한 연구)

  • Cho, Sam-Ju;Chung, Young-Lip;Lee, Sang-Hoon;Huh, Hyun-Do;Choi, Jin-Ho;Park, Sung-Ill;Shim, Su-Jung;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.71-80
    • /
    • 2012
  • In order to verify exact dose distributions in the state-of-the-art radiation techniques, a newly designed three-dimensional dosimeter and technique has been took strongly into consideration. The main purpose of our study is to verify the optimized parameters of polymer gel as a real volumetric dosimeter in terms of the various study of MRI. We prepared a gel dosimeter by combing 8% of gelatin, 8% of MAA, and 10 mM of THPC. We used a Co-60 gamma-ray teletherapy unit and delivered doses of 0, 2, 4, 6, 8, 10, 12, and 14 Gy to each polymer gel with a solid phantom. We used a fast spin-echo pulse to acquire the characterized T2 time of MRI. The signal noise ratio (SNR) of the head & neck coil was a relatively lower sensitivity than the body coil; therefore the dose uncertainty of head & neck coil would be lower than body coil's. But the dose uncertainty and resolution of the head & neck coil were superior to the body coil in this study. The TR time between 1,500 ms and 2,000 ms showed no significant difference in the dose resolution, but TR of 1,500 ms showed less dose uncertainty. For the slice thickness of 2.5 mm, less dose uncertainty of TE times was at 4 Gy, as well, it was the lowest result over 4 Gy at TE of 12 ms. The dose uncertainty was not critical up to 6 Gy, but the best dose resolution was obtained at 20 ms up to 8 Gy. The dose resolution shows the lowest value was over 20 ms and was an excellent result in the number of excitation (NEX) of three. The NEX of two was the highest dose resolution. We concluded that the better result of slice thickness versus NEX was related to the NEX increment and thin slice thickness.

Determination of Dose Correction Factor for Energy and Directional Dependence of the MOSFET Dosimeter in an Anthropomorphic Phantom (인형 모의피폭체내 MOSFET 선량계의 에너지 및 방향 의존도를 고려하기 위한 선량보정인자 결정)

  • Cho, Sung-Koo;Choi, Sang-Hyoun;Na, Seong-Ho;Kim, Chan-Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.2
    • /
    • pp.97-104
    • /
    • 2006
  • In recent years, the MOSFET dosimeter has been widely used in various medical applications such as dose verification in radiation therapeutic and diagnostic applications. The MOSFET dosimeter is, however, mainly made of silicon and shows some energy dependence for low energy Photons. Therefore, the MOSFET dosimeter tends to overestimate the dose for low energy scattered photons in a phantom. This study determines the correction factors to compensate these dependences of the MOSFET dosimeter in ATOM phantom. For this, we first constructed a computational model of the ATOM phantom based on the 3D CT image data of the phantom. The voxel phantom was then implemented in a Monte Carlo simulation code and used to calculate the energy spectrum of the photon field at each of the MOSFET dosimeter locations in the phantom. Finally, the correction factors were calculated based on the energy spectrum of the photon field at the dosimeter locations and the pre-determined energy and directional dependence of the MOSFET dosimeter. Our result for $^{60}Co$ and $^{137}Cs$ photon fields shows that the correction factors are distributed within the range of 0.89 and 0.97 considering all the MOSFET dosimeter locations in the phantom.

Construction of voxel head phantom and application to BNCT dose calculation (Voxel 머리팬텀 제작 및 붕소중성자포획요법 선량계산에의 응용)

  • Lee, Choon-Sik;Lee, Choon-Ik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.93-99
    • /
    • 2001
  • Voxel head phantom for overcoming the limitation of mathematical phantom in depleting anatomical details was constructed and example dose calculation for BNCT was performed. The repeated structure algorithm of the general purpose Monte Carlo code, MCNP4B was applied for yokel Monte Carlo calculation. Simple binary yokel phantom and combinatorial geometry phantom composed of two materials were constructed for validating the voxel Monte Carlo calculation system. The tomographic images of VHP man provided by NLM(National Library of Medicine) were segmented and indexed to construct yokel head phantom. Comparison of doses for broad parallel gamma and neutron beams in AP and PA directions showed decrease of brain dose due to the attenuation of neutron in eye balls in case of yokel head phantom. The spherical tumor volume with diameter, 5cm was defined in the center of brain for BNCT dose calculation in which accurate 3 dimensional dose calculation is essential. As a result of BNCT dose calculation for downward neutron beam of 10keV and 40keV, the tumor dose is about doubled when boron concentration ratio between the tumor to the normal tissue is $30{\mu}g/g$ to $3{\mu}g/g$. This study established the voxel Monte Carlo calculation system and suggested the feasibility of precise dose calculation in therapeutic radiology.

  • PDF

Methodological Issues in Socio-Economic Assessment of the Hydrogen Economy Development (수소경제로 이행을 위한 사회경제적 영향평가 방법론)

  • Kim, Ho-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.586-591
    • /
    • 2005
  • 우리나라는 에너지의 안정적 공급과 에너지이용 과정에서 발생하는 환경적, 안보적 외부성을 최소화하는 에너지수급 구조를 마련하기 위해 2003년 12월 '제2차 신재생에너지 기술개발 및 이용보급 기본계획(2003-2012)'을 발표하였다. 이 계획에서는 2011년까지 전체 TPES의 $5\%$를 신재생에너지로 공급하는 것을 정책목표로 수립하고 수소, 태양광 그리고 풍력기술을 중점적으로 추진하기로 하였다. 특히 수소부문에서는 주택 및 건물용, 발전용, 수송용 연료전지의 개발을 중심으로 개발하여 세계 기술시장의 $20\%$를 확보한다는 계획을 발표하였다. 이러한 기술 잠재력을 기반으로 우리 정부도 미국이나 일본과 같이 수소경제로의 전환을 준비하고 있으며 2020년대 이후 우리나라의 에너지부문은 새로운 국면에 접어들 것으로 전망된다. 에너지나 환경기술의 효과적 인 개발을 위해서는 이들 기술의 직접적인 비용측면에 대한 분석 즉 경제성 평가와 새로운 기술변화로 인한 중장기적인 사회경제적 영향평가가 선행되어야 한다. 이러한 평가는 대상 기술의 사회경제적 파급효과가 광범위할수록 더욱 복잡한 분석이 요구된다. 본 연구의 주제인 수소에너지기술은 지금까지 이용되던 것과는 전혀 새로운 에너지캐리어(carrier)를 개발하는 것으로 에너지부문 및 여타 다른 산업부문이 공유하고 있는 에너지 관련 인프라의 전면적인 조정이 요구되며 에너지 이용과 관련된 사회경제적 측면의 급속한 변화를 수반한다. 본 연구는 수소경제로의 이행에 대한 사회경제적 영향평가의 방법론적 요소들과 기법을 제시한다."중등도 독성"으로 나타났다 이상의 결과는 전기도금을 이용하여 교정용 선재의 직경을 증가시키는 방법이 임상에 적용되기 위해서는 세포독성을 줄이기 위한 추가의 연구가 필요함을 시사하였다.의하게 가장 낮은 정지. 운동 마찰력을 보였고 브라켓-호선 각도가 증가함에 따라 유의하게 정지, 운동 마찰력도 증가하였다 (P<0.001)%$ 낮추지만(p value=0.260) 평균 $D_{max}$는 거의동일 하여($0.3\%$ 감소, p value=0.867), 전통적인 방법보다 우수성이 크게는 없는 것으로 평가되었다. 그러나 환자의 체곡선이 보상체와 잘 일치하는 경우에는 DII가 $18\%$까지 감소하였다. 결론 : Multistatic field 방법은 모든 환자에 대하여 선량분포의 균일성을 전반적으로 향상시키는 효과적인 방법으로 평가되는 반면 공용보상체의 사용은 보상체의 크기가 환자의 체 윤곽과 잘 일치하는 경우만 효과적으로, 적용의 범위에는 한계가 있는 방법으로 평가되었다.비교하여 계통에 따르는 차이가 있음을 알 수 있었다. 그러므로 가임기 여성의 방사선 진단 및 치료시 Rugh의 10일 법칙을 적용하여 착상전기 방사선 조사로 인한 부작용들을 적극적으로 예방하는 것이 매우 중요하다고 생각한다.equirements of the prematured infants during the early weeks of life. 모든 치근단 수준에서 비표준화 medium 크기 master cone 사용군이 ISO 표준화 규격의 master cone 사용군에 비해

  • PDF

A Study on the Simulation and the Measurement of 6 MeV electron Beam (6 MeV 전자선의 측정과 모의계산에 대한 연구)

  • Lee Sung Ah;Lee Jeong Ok;Moon Sun Rock;Won Jong Jin;Kang Jeong Ku;Kim Seung Kon
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.285-289
    • /
    • 1995
  • Purpose : We compared the calcualted percent depth dose curves of 6 MeV electron beam to that of measured to evaluate the usefulness of Monte-carlo simulation method in radiation physics. Materials and Methods : The radiation dose values of 6 MeV electron beam using EGS4 code with one million histories in water were compared values that were measured from the depth dose curve of electron beam irradiated by medical accelerator ML6M. The central axis dose values were calculated according to the changing field size. such as $5{\times}5,\;10{\times}10,\;15{\times}15,\;20{\times}20cm^2$. Results : The value calculated showed a very similar shape to depth dose curve. The calculated and measured value of $D_max$ at $10{\times}10cm^2$ cone is 15mm and 14mm respectively. The calculated value of the surface radiation dose rate is $65.52\%$ and measured one is $76.94\%$. The surface radiation dose rate has varied from $64.43\%$ to $66.99\%$. The calculated values of $D_max$ are in the range between 15mm and 18mm. The calculated value was fitted well with measured value around the $D_max$ area, excluding build up range and below the $90\%$ depth dose area. Conclusion : This result suggested that the calculation of dose value can be replace the direct measurement of the dose for radiation therapy. Also, EGS4 may be a very convenient program to assess the effect of radiation dose using by personal computers.

  • PDF

Susceptibility-Weighted Imaging as a Distinctive Imaging Technique for Providing Complementary Information for Precise Diagnosis of Neurologic Disorder (신경계 질환에 관한 정확한 진단을 위해 다양한 보완 정보를 제공하는 독특한 영상 기법으로서의 자기화율 강조 영상)

  • Byeong-Uk Jeon;In Kyu Yu;Tae Kun Kim;Ha Youn Kim;Seungbae Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.99-115
    • /
    • 2021
  • Various sequences have been developed for MRI to aid in the radiologic diagnosis. Among the various MR sequences, susceptibility-weighted imaging (SWI) is a high-spatial-resolution, three-dimensional gradient-echo MR sequence, which is very sensitive in detecting deoxyhemoglobin, ferritin, hemosiderin, and bone minerals through local magnetic field distortion. In this regard, SWI has been used for the diagnosis and treatment of various neurologic disorders, and the improved image quality has enabled to acquire more useful information for radiologists. Here, we explain the principle of various signals on SWI arising in neurological disorders and provide a retrospective review of many cases of clinically or pathologically proven disease or components with distinctive imaging features of various neurological diseases. Additionally, we outline a short and condensed overview of principles of SWI in relation to neurological disorders and describe various cases with characteristic imaging features on SWI. There are many different types diseases involving the brain parenchyma, and they have distinct SWI features. SWI is an effective imaging tool that provides complementary information for the diagnosis of various diseases.

AUTOTRANSPLANTATION OF TOOTH WITH IMMATURE ROOT FORMATION (치근단 미완성 치아의 자가치아이식)

  • Jung, Ji-Sook;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.1
    • /
    • pp.66-72
    • /
    • 2012
  • Autogenous tooth transplantation can be defined as the surgical movement of a tooth from one position in the mouth to another in the same individual. The most common reasons for tooth transplantation include replacement of a missing first molar, transplantation of impacted canines to their normal positions in the arch, and transplantation of premolars in areas of missing teeth, especially in the anterior area of the mouth. The key to successful tooth transplantation is proper selection of graft with adequate root development as well as the design of surgical operation. Root development stage with half to three-quarter-developed roots increase the success rate of autotransplantation. We report the cases of successful autotransplantation which resulted in ideal healing of periodontal ligament, gingiva and alveolar bone. All transplanted teeth presented immature root formation at the moment of the procedure. After surgical procedure, we can observe good healing pattern without endodontic problem.