• Title/Summary/Keyword: 방사선시험

Search Result 436, Processing Time 0.024 seconds

협회소식

  • Korea Radioisotope Association
    • 동위원소뉴스
    • /
    • no.10 s.34
    • /
    • pp.2-3
    • /
    • 1999
  • PDF

A study on Phantom image of Mammography in some area (일부지역 유방촬영술의 팬톰영상에 관한 연구)

  • Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.301-306
    • /
    • 2005
  • Purpose : The goal of this study was to survey the quality control of mammographic phantom images in some area. Methods : Between May and June, 2005, I have got a total of 47 mammographic phantom images collected from 49 hospitals and were analized about phantom score of fibrous, speck, tumor with enlargement scope. By critic level of experimental mammographic phantom case images, classified through the pass case that fibrous score 4, speck score 3, tumor score 3 over. Result : It passed 33case (70.3%), failed 14 case (29.7%) about 47 case. Passing case images showed tube voltage $23{\sim}30\;kVp$, tube current $20{\sim}60\;mAs$, photographic density $0.48{\sim}1.77$ Conclusion : It passed case about 70.3% of mammographic phantom image in some area. Optimum range of tube voltage, tube current, photographic density have to use to get fine quality of mammographic images.

  • PDF

A Study on Dry and Wet Wipe Test for Radioisotope Leakage Checking (방사성동위원소 누설 점검을 위한 건식 및 습식 문지름 시험법 연구)

  • Park, SangMin;Yoo, SeungHee;Choi, KyuSeok;Lee, HwaHyung;Hong, Sayong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.305-312
    • /
    • 2018
  • A dry and wet wipe test for radioisotope leakage checking was conducted by fixing the radioisotope $^{14}C$ to the glass surface and used for observing the transfer factor and surface shape of the test paper through wipe test. The dry wipe test showed that transfer factor in the tissue paper was twice as high as in the paper filter, and the wet wipe test showed that transfer factor in the paper filter paper was three times higher than the tissue paper. Although paper filters are general choice for leakage checking, it has been shown that tissue paper can be an alternative in the dry wipe test.

양성자 가속기를 이용한 우주용 전자 부품의 방사선 인증 시험

  • 선종호;김성준;민경욱;정성근;최원호
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.04a
    • /
    • pp.47-47
    • /
    • 2004
  • 사이클로트론 가속기를 이용한 양성자 우주환경의 모사시험이 수행되었다. 모사시험에 사용된 사이클로트론은 양성자를 약 106-108protons/$\textrm{cm}^2$/s의 선속에서 200MeV까지 가속할 수 있다. 가속된 양성자는 우주에서 사용될 전자 소자에 입사되었으며, 양성자 조사에 의한 소자의 누적 반응과 순간 반응이 모두 관찰되었다. 주된 순간 반응은 저장된 데이터의 변화였으나, 간헐적인 기능 정지 현상도 관찰되었다. 누적 반응은 소자 내에서 소모되는 전류의 증가로 나타났다. (중략)

  • PDF