• Title/Summary/Keyword: 방사선시험

Search Result 436, Processing Time 0.022 seconds

Irradiation Test of Bar Code Label (바코드 라벨의 방사선 조사시험)

  • 배상민;이강무;손종식;홍권표;고병령
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.544-548
    • /
    • 2003
  • The Irradiation test of bar code label tagged on radioactive waste container was done to determine the effect of radiation. Low and medium radioactive waste is that below total activity of 4,000 Bq/g according to the Korean nuclear law. The irradiation amount to radiate bar code label tagged on radioactive waste container was calculated by MCNP-4b computer code. The nuclide such as Co-60 and Cs-137 was assumed to contribute 50% of total activity. Real irradiation amount for bar code label was finally calculated by the dimensions of the container and the bar code label. The Identification of post and the physical deflection of irradiated bar code label was tested by the bar code reader. The coated bar code label was suitable to use on low and medium radioactive waste container.

  • PDF

ASIC Implementation of Nuclear Radiation Detector Using Semiconductor Sensor (반도체 센서를 이용 방사선 검출기의 ASIC 구현)

  • Yi, Un-Kun;Baek, Kwang-Ryul;Sohn, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2353-2355
    • /
    • 2004
  • 본 논문에서는 고정도의 방사선 측정이 가능한 능동형 전자선량계를 제작하기 위해 필수적으로 요구되는 반도체 방사선 검출기를 ASIC으로 구현하였다. 이는 전자선량계의 소형화와 저소비전력을 실현할 수 있도록 전치증폭기와 성형증폭기를 일체화한 것으로 방사선과 방사선 검출 소자인 상용 핀 포토다이오드의 상호작용으로 생성된 수 [nA]의 전류펄스를 측정할 수 있다. MOSIS 공정을 통하여 ASIC으로 구현된 방사선검출기는 $10{\mu}Ci$${\gamma}$-선 Ba-133, Cs-137 및 Co-60의 세 핵종에 대하여 방사선 조사시험을 수행하여 구현된 방사선 검출기의 유용성을 입증하였다.

  • PDF

협회소식

  • Korea Radioisotope Association
    • 동위원소뉴스
    • /
    • no.4 s.28
    • /
    • pp.2-3
    • /
    • 1999
  • PDF

The Performance Test of Teledyne PB-3 Personnel Dosimetry System by Intercomparison Study (국제상호비교검증을 통한 Teledyne PB-3 개인선량계시스템의 성능시험)

  • Lee, Sang-Yoon;Lee, Hyung-Sub;Kim, Jung-Lyul;Yoon, Suk-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.2
    • /
    • pp.133-145
    • /
    • 1994
  • Recently, the Ministry of Science and Technology issued a Ministerial Ordinance (No 1992-15) about the technical criteria on personnel radiation dosimetry. In today's climate, it is important to demonstrate and document that the processor's systems and services to others meet national standards of quality. The purpose of this study is to verify the performance of the Teledyne PB-3 personnel dosimetry system that is generally used in Korea Atomic Energy Research Institute(KAERI) by intercomparison with Oak Ridge National Laboratory. The KAERI has been participated in this personnel dosimetry intercomparison study(PDIS) program since 1991 and it could be possible to test and calibrate personnel monitoring system. This report presents a summary and analysis of by about 50 dose equivalent measurements reported for PDIS-16 through 18 (1991 -1993) with emphasis on neutron dose equivalent sensitivity, accuracy and precision. Relationships of the PDIS results to occupational neutron monitoring and methods to improve personnel dosimetry performance are also discussed.

  • PDF